arXiv Science⌕ Search

arXiv subjects

W. Gradl

Publications and source records attributed to W. Gradl.

453 records · Page 26Linked to original sources

First observation of the M1 transition $ψ(3686)\to γη_c(2S)$

Using a sample of 106 million ψ(3686) events collected with the BESIII detector at the BEPCII storage ring, we have made the first measurement of the M1 transition between the radially excited charmonium S-wave spin-triplet and the radially excited S-wave spin-singlet states: ψ(3686)\toγη_c(2S). Analyses of the processes ψ(2S)\to γη_c(2S) with η_c(2S)\to \K_S^0 Kπand K^+K^-π^0 gave an η_c(2S) signal with a statistical significance of greater than 10 standard deviations under a wide range of assumptions about the signal and background properties. The data are used to obtain measurements of the η_c(2S) mass (M(η_c(2S))=3637.6\pm 2.9_\mathrm{stat}\pm 1.6_\mathrm{sys} MeV/c^2), width (Γ(η_c(2S))=16.9\pm 6.4_\mathrm{stat}\pm 4.8_\mathrm{sys} MeV), and the product branching fraction (\BR(ψ(3686)\to γη_c(2S))\times \BR(η_c(2S)\to K\bar Kπ) = (1.30\pm 0.20_\mathrm{stat}\pm 0.30_\mathrm{sys})\times 10^{-5}). Combining our result with a BaBar measurement of \BR(η_c(2S)\to K\bar K π), we find the branching fraction of the M1 transition to be \BR(ψ(3686)\toγη_c(2S)) = (6.8\pm 1.1_\mathrm{stat}\pm 4.5_\mathrm{sys})\times 10^{-4}.

hep-ex↗

Two-photon widths of the $χ_{c0, 2}$ states and helicity analysis for $χ_{c2}\arγγ$}

Based on a data sample of 106 M $ψ^{\prime}$ events collected with the BESIII detector, the decays $ψ^{\prime}\arγχ_{c0, 2}$,$χ_{c0, 2}\arγγ$ are studied to determine the two-photon widths of the $χ_{c0, 2}$ states. The two-photon decay branching fractions are determined to be ${\cal B}(χ_{c0}\arγγ) = (2.24\pm 0.19\pm 0.12\pm 0.08)\times 10^{-4}$ and ${\cal B}(χ_{c2}\arγγ) = (3.21\pm 0.18\pm 0.17\pm 0.13)\times 10^{-4}$. From these, the two-photon widths are determined to be $Γ_{γγ}(χ_{c0}) = (2.33\pm0.20\pm0.13\pm0.17)$ keV, $Γ_{γγ}(χ_{c2}) = (0.63\pm0.04\pm0.04\pm0.04)$ keV, and $\cal R$ $=Γ_{γγ}(χ_{c2})/Γ_{γγ}(χ_{c0})=0.271\pm 0.029\pm 0.013\pm 0.027$, where the uncertainties are statistical, systematic, and those from the PDG ${\cal B}(ψ^{\prime}\arγχ_{c0,2})$ and $Γ(χ_{c0,2})$ errors, respectively. The ratio of the two-photon widths for helicity $λ=0$ and helicity $λ=2$ components in the decay $χ_{c2}\arγγ$ is measured for the first time to be $f_{0/2} =Γ^{λ=0}_{γγ}(χ_{c2})/Γ^{λ=2}_{γγ}(χ_{c2}) = 0.00\pm0.02\pm0.02$.

hep-ex↗

Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the Inner Tracking System of HERA-B

The results of five years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about 20 * 20 cm2 each. The detector is based on microstrip gas counters (MSGCs) with diamond like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step. Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar-DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO2 showed no serious aging effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000.

hep-ex↗