$K^{*}(892)^0$ production and the time between freeze-outs in $^{40}$Ar+$^{45}$Sc collisions by NA61/SHINE at the CERN SPS

The analysis of the production of strange $K^{*}(892)^0$ resonances allows us to better understand the temporal evolution of high-energy nucleus--nucleus collisions. In particular, the ratio of $K^{*}(892)^0$ to charged kaon yields is used to determine the time interval between chemical and kinetic freeze-outs. In this paper, the first measurements of $K^{*}(892)^0$ production in central $^{40}$Ar+$^{45}$Sc collisions at the CERN Super Proton Synchrotron are reported. They were performed by NA61/SHINE at collision center-of-mass energies per nucleon pair $\sqrt{s_\mathrm{NN}}$ = 8.8, 11.9, 16.8 GeV. The obtained $\langle K^{*}(892)^0 \rangle/\langle K^{+} \rangle $ and $\langle K^{*}(892)^0 \rangle/\langle K^{-} \rangle$ mean multiplicity ratios are compared with corresponding results in $p$+$p$ collisions, allowing for an estimate of the time interval between chemical and thermal freeze-outs in the $^{40}$Ar+$^{45}$Sc system. These are the first such results reported for $^{40}$Ar+$^{45}$Sc collisions.

nucl-ex

The design of the data acquisition system for SPD experiment

The Spin Physics Detector (SPD) experiment at the NICA collider in JINR aims to investigate the spin structure of nucleons and spin-related phenomena. The combination of the number of background processes, the event rate and conditions for event selection makes the use of a classical trigger system impractical, requiring a triggerless data acquisition (DAQ) system. The DAQ system is designed to ensure precise time synchronization, efficient data collection, and high-throughput processing. Its architecture combines commercially available FPGA-based modules and high-speed optical interfaces with custom-developed components based on widely accessible technologies. This approach provides scalability from 180,000 at the initial stage of the experiment to more than 600,000 detector channels in the final configuration and supports data rates up to 20 GB/s or more. The modular system design ensures adaptability for future upgrades while maintaining high efficiency and reliability. Such an approach makes the DAQ system suitable for other high-rate nuclear physics experiments.

physics.ins-det

Mu2e calorimeter readout system

The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the shaping amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.

physics.ins-det

The Mu2e calorimeter: quality assurance of production crystals and SiPMs

The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.

physics.ins-det

Quality Assurance on Un-Doped CsI Crystals for the Mu2e Experiment

The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.

physics.ins-det

The Mu2e Calorimeter Final Technical Design Report

Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.

physics.ins-det

Design and status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.

physics.ins-det

Design, status and perspective of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $\mu \to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $\mu$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R$\&$D results.

physics.ins-det

The Mu2e undoped CsI crystal calorimeter

The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.

physics.ins-det

Quality Assurance on a custom SiPMs array for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the coherent $\mu \to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.

physics.ins-det

Measurement of the energy and time resolution of a undoped CsI + MPPC array for the Mu2e experiment

This paper describes the measurements of energy and time response and resolution of a 3 x 3 array made of undoped CsI crystals coupled to large area Hamamatsu Multi Pixel Photon Counters. The measurements have been performed using the electron beam of the Beam Test Facility in Frascati (Rome, Italy) in the energy range 80-120 MeV. The measured energy resolution, estimated with the FWHM, at 100 MeV is 16.4%. This resolution is dominated by the energy leakage due to the small dimensions of the prototype. The time is reconstructed by fitting the leading edge of the digitized signals and applying a digital constant fraction discrimination technique. A time resolution of about 110 ps at 100 MeV is achieved.

physics.ins-det

The calorimeter of the Mu2e experiment at Fermilab

The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10-4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.

physics.ins-det

Design and status of the Mu2e electromagnetic calorimeter

The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

physics.ins-det

Design, status and test of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of a aluminum nucleus. The dynamic of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with about 700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. These crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.

physics.ins-det

Optimization of light yield by injection of the optical filler into the co extruded hole of plastic scintillation bar with WLS fiber in it

Results of the measurements with cosmic muons for the light yield of 2-meter long extruded scintillation bar (strip) as a function of distance for different options for light collection technique are presented. Scintillation strip cross section geometry was a triangle made on polystyrene plastic scintillator with dopants of 2% PTP and 0.03% POPOP, extruded with 2.6 mm diameter hole and produced at ISMA (Kharkov, Ukraine). It was shown that the insertion of the optical transparent resin (BC 600 or CKTN MED(E)) by special technique into the co-extruded hole with 1.0 mm or 1.2 mm wave-length shifter (WLS) fiber Kuraray Y11 (200) MC in it significantly improves light collection by factor of 1.6...1.9 against of the 'dry' case.

physics.ins-det

Measurement of time resolution of the Mu2e LYSO calorimeter prototype

In this paper we present the time resolution measurements of the Lutetium-Yttrium Oxyorthosilicate (LYSO) calorimeter prototype for the Mu2e experiment. The measurements have been performed using the $e^-$ beam of the Beam Test Facility (BTF) in Frascati, Italy in the energy range from 100 to 400 MeV. The calorimeter prototype consisted of twenty five 30x30x130 mm$^3$, LYSO crystals read out by 10x10 mm$^2$ Hamamatsu Avalanche Photodiodes (APDs). The energy dependence of the measured time resolution can be parametrized as $\sigma_{t}(E)=a/\sqrt{E/\mathrm{GeV}} \oplus b$, with the stochastic and constant terms $a=(51\pm1)$ ps and $b=(10\pm4)$ ps, respectively. This corresponds to the time resolution of ($162\pm4$) ps at 100 MeV.

physics.ins-det

Production of $^{6}_{\Lambda}$H and $^{7}_{\Lambda}$H with the (K$^{-}_{stop}$,$\pi^+$) reaction

The production of neutron rich $\Lambda$-hypernuclei via the ($K^-_stop$,$\pi^+$) reaction has been studied using data collected with the FINUDA spectrometer at the DA$\Phi$NE $\phi$-factory (LNF). The analysis of the inclusive $\pi^+$ momentum spectra is presented and an upper limit for the production of $^6_\Lambda$H and $^7_\Lambda$H from $^6$Li and $^7$Li, is assessed for the first time.

nucl-ex