arXiv ScienceSearch

arXiv subjects

Tzyy-Ping Jung

Publications and source records attributed to Tzyy-Ping Jung.

2 recordsLinked to original sources

Drift Calibration in Geometric Eye Tracking Systems

Geometric eye trackers can provide the spatial accuracy required for gaze-based interaction and multimodal studies, but their measurements remain sensitive to residual session-specific calibration error. Research on correcting this error is difficult to compare because methods are typically evaluated with different devices, target layouts, and error definitions. We present a calibration-focused dataset containing 163 trials from 12 participants, with separate 18-point fitting and 32-point test grids, and use it to evaluate global, local, and composite correction functions under a common spatial-extrapolation protocol. We further introduce a lightweight neural refiner that combines ranked predictions from complementary calibrators. On this controlled dataset, post-vendor correction reduces the mean angular error from $1.53^\circ$ to $1.03^\circ$ with the strongest classical composite and to $0.96^\circ$ with the refiner. In a closed-loop gaze task, lower residual error is associated with higher performance across four online correction conditions. These results provide a reproducible data-quality benchmark for using gaze as a behavioral signal in interactive modeling.

cs.CV

Leveraging a Foundation Model for the EEG-Based Diagnosis of Alzheimer's Disease

Biological heterogeneity in Alzheimer's Disease (AD) poses a critical diagnostic challenge, particularly for traditional linear methods that fail to capture non-linear neural dynamics. To address this, we propose a diagnostic framework utilizing the Large Brain Model (LaBraM), pretrained on over 2,500 hours of EEG data. By integrating these high-dimensional latent embeddings with a non-linear Random Forest classifier, our approach effectively isolates robust disease markers. Under a rigorous subject-independent 5-fold cross-validation protocol, the method achieves an ROC-AUC of 89.36% +/- 3.49%, PR AUC of 81.45% +/- 4.43%, and Balanced Accuracy of 82.44% +/- 4.34% in distinguishing dementia patients from healthy controls. Notably, this performance uses only 8-second EEG segments, surpassing traditional spectral baselines, including band-power and parameterized oscillatory features (FOOOF). Post-hoc occlusion analysis confirms the model captures clinically validated biomarkers, specifically occipital-frontal Alpha and Theta rhythm degradation. Additional neurophysiological alignment analysis demonstrated that higher LaBraM-predicted dementia probability significantly correlated with worse cognitive performance, greater clinical severity, increased theta and alpha relative power, and higher aperiodic exponent. These findings demonstrate that deep latent representations extract clinically relevant signatures from noisy signals, enabling precise, rapid, and data-efficient diagnosis.

cs.LG