arXiv ScienceSearch

arXiv subjects

Tomoya Kitamura

Publications and source records attributed to Tomoya Kitamura.

4 recordsLinked to original sources

An Environment-Adaptive Position/Force Control Based on Physical Property Estimation

The current methods to generate robot actions for automation in significantly different environments have limitations. This paper proposes a new method that matches the impedance of two prerecorded action data with the current environmental impedance to generate highly adaptable actions. This method recalculates the command values for the position and force based on the current impedance to improve reproducibility in different environments. Experiments conducted under conditions of extreme action impedance, such as position and force control, confirmed the superiority of the proposed method over existing motion reproduction system. The advantages of this method include the use of only two sets of motion data, significantly reducing the burden of data acquisition compared with machine-learning based methods, and eliminating concerns about stability by using existing stable control systems. This study contributes to improving the environmental adaptability of robots while simplifying the action generation method.

cs.RO

Heat transport in nonlinear lattices free from the Umklapp process

We construct one-dimensional nonlinear lattices having the special property such that the Umklapp process vanishes and only the normal processes are included in the potential functions. These lattices have long-range quartic nonlinear and nearest neighbor harmonic interactions with/without harmonic on-site potential. We study heat transport in two cases of the lattices with and without harmonic on-site potential by non-equilibrium molecular dynamics simulation. It is shown that the ballistic heat transport occurs in both cases, i.e., the scaling law $κ\propto N$ holds between the thermal conductivity $κ$ and the lattice size $N$. This result directly validates Peierls's hypothesis that only the Umklapp processes can cause the thermal resistance while the normal one do not.

nlin.CD

Estimation of Relationship between Stimulation Current and Force Exerted during Isometric Contraction

In this study, we developed a method to estimate the relationship between stimulation current and volatility during isometric contraction. In functional electrical stimulation (FES), joints are driven by applying voltage to muscles. This technology has been used for a long time in the field of rehabilitation, and recently application oriented research has been reported. However, estimation of the relationship between stimulus value and exercise capacity has not been discussed to a great extent. Therefore, in this study, a human muscle model was estimated using the transfer function estimation method with fast Fourier transform. It was found that the relationship between stimulation current and force exerted could be expressed by a first-order lag system. In verification of the force estimate, the ability of the proposed model to estimate the exerted force under steady state response was found to be good.

cs.HC

Bilateral Control of Two Finger Joints Using Functional Electrical Stimulation

Bilateral control, a remote-control technique, is used to work at a distance. However, many existing bilateral control systems have two common problems: 1) it is difficult to create a system like a human hand, that has multiple degrees of freedom and 2) if the mechanism becomes too complicated, operators feel restrained and experience discomfort. Because, for these reasons, the bilateral control of fingers has not been accomplished to date, we aimed to overcome this by applying functional electrical stimulation~(FES). In our experiments, through an adhesive electrode pad, electrical stimulation was delivered to the muscles that flex and expand the metacarpophalangeal joints of the thumb and middle finger. Position-symmetrical bilateral control was implemented so that the deviation of the master's and slave's positions relative to each other was zero degrees. A sliding mode controller was used as a position controller. We found it possible to control multiple degrees of freedom; however, we found areas where the number of tracking errors was large. We speculated that the middle finger did not bend, because the arm rotates as the thumb was abduction, therefore the position of the motor point of the middle finger deviates from the position of the pad.

physics.bio-ph