arXiv ScienceSearch

arXiv subjects

Tianshun Miao

Publications and source records attributed to Tianshun Miao.

4 recordsLinked to original sources

Edge-Tilting Field Dynamics: Rapid Mixing at the Uniqueness Threshold and Optimal Mixing for Swendsen-Wang Dynamics

We prove two results on the mixing times of Markov chains for two-spin systems. First, we show that the Glauber dynamics mixes in polynomial time for the Gibbs distributions of antiferromagnetic two-spin systems at the critical threshold of the uniqueness phase transition of the Gibbs measure on infinite regular trees. This completes the computational phase transition picture for antiferromagnetic two-spin systems, which includes near-linear-time optimal mixing in the uniqueness regime [Chen--Liu--Vigoda, STOC '21; Chen--Feng--Yin--Zhang, FOCS '22], NP-hardness of approximate sampling in the non-uniqueness regime [Sly--Sun, FOCS '12], and polynomial-time mixing at criticality (this work). Second, we prove an optimal $O(\log n)$ mixing time bound as well as an optimal $\Omega(1)$ spectral gap for the Swendsen--Wang dynamics for the ferromagnetic Ising model with an external field on bounded-degree graphs. To the best of our knowledge, these are the first sharp bounds on the mixing rate of this classical global Markov chain beyond mean-field or strong spatial mixing (SSM) regimes, and resolve a conjecture of [Feng--Guo--Wang, IANDC '23]. A key ingredient in both proofs is a new family of localization schemes that extends the field dynamics of [Chen--Feng--Yin--Zhang, FOCS '21] by tilting general edge (or hyperedge) weights rather than vertex fields. This framework, which subsumes the classical Swendsen--Wang dynamics as a special case, extends the localization framework of [Chen--Eldan, FOCS '22] beyond stochastic and field localizations, and enables controlled tilting of interaction strengths while preserving external fields.

cs.DS

Faster Mixing of the Jerrum-Sinclair Chain

We show that the Jerrum-Sinclair Markov chain on matchings mixes in time $\widetilde{O}(\Delta^2 m)$ on any graph with $n$ vertices, $m$ edges, and maximum degree $\Delta$, for any constant edge weight $\lambda>0$. For general graphs with arbitrary, potentially unbounded $\Delta$, this provides the first improvement over the classic $\widetilde{O}(n^2 m)$ mixing time bound of Jerrum and Sinclair (1989) and Sinclair (1992). To achieve this, we develop a general framework for analyzing mixing times, combining ideas from the classic canonical path method with the "local-to-global" approaches recently developed in high-dimensional expanders, introducing key innovations to both techniques.

cs.DS

Noise-aware Dynamic Image Denoising and Positron Range Correction for Rubidium-82 Cardiac PET Imaging via Self-supervision

Rb-82 is a radioactive isotope widely used for cardiac PET imaging. Despite numerous benefits of 82-Rb, there are several factors that limits its image quality and quantitative accuracy. First, the short half-life of 82-Rb results in noisy dynamic frames. Low signal-to-noise ratio would result in inaccurate and biased image quantification. Noisy dynamic frames also lead to highly noisy parametric images. The noise levels also vary substantially in different dynamic frames due to radiotracer decay and short half-life. Existing denoising methods are not applicable for this task due to the lack of paired training inputs/labels and inability to generalize across varying noise levels. Second, 82-Rb emits high-energy positrons. Compared with other tracers such as 18-F, 82-Rb travels a longer distance before annihilation, which negatively affect image spatial resolution. Here, the goal of this study is to propose a self-supervised method for simultaneous (1) noise-aware dynamic image denoising and (2) positron range correction for 82-Rb cardiac PET imaging. Tested on a series of PET scans from a cohort of normal volunteers, the proposed method produced images with superior visual quality. To demonstrate the improvement in image quantification, we compared image-derived input functions (IDIFs) with arterial input functions (AIFs) from continuous arterial blood samples. The IDIF derived from the proposed method led to lower AUC differences, decreasing from 11.09% to 7.58% on average, compared to the original dynamic frames. The proposed method also improved the quantification of myocardium blood flow (MBF), as validated against 15-O-water scans, with mean MBF differences decreased from 0.43 to 0.09, compared to the original dynamic frames. We also conducted a generalizability experiment on 37 patient scans obtained from a different country using a different scanner.

eess.IV

Fast-MC-PET: A Novel Deep Learning-aided Motion Correction and Reconstruction Framework for Accelerated PET

Patient motion during PET is inevitable. Its long acquisition time not only increases the motion and the associated artifacts but also the patient's discomfort, thus PET acceleration is desirable. However, accelerating PET acquisition will result in reconstructed images with low SNR, and the image quality will still be degraded by motion-induced artifacts. Most of the previous PET motion correction methods are motion type specific that require motion modeling, thus may fail when multiple types of motion present together. Also, those methods are customized for standard long acquisition and could not be directly applied to accelerated PET. To this end, modeling-free universal motion correction reconstruction for accelerated PET is still highly under-explored. In this work, we propose a novel deep learning-aided motion correction and reconstruction framework for accelerated PET, called Fast-MC-PET. Our framework consists of a universal motion correction (UMC) and a short-to-long acquisition reconstruction (SL-Reon) module. The UMC enables modeling-free motion correction by estimating quasi-continuous motion from ultra-short frame reconstructions and using this information for motion-compensated reconstruction. Then, the SL-Recon converts the accelerated UMC image with low counts to a high-quality image with high counts for our final reconstruction output. Our experimental results on human studies show that our Fast-MC-PET can enable 7-fold acceleration and use only 2 minutes acquisition to generate high-quality reconstruction images that outperform/match previous motion correction reconstruction methods using standard 15 minutes long acquisition data.

eess.IV