arXiv Science⌕ Search

arXiv subjects

Teng Liu

Publications and source records attributed to Teng Liu.

112 records · Page 7Linked to original sources

Are X-ray Emitting Coronae around Super Massive Black Holes Outflowing?

Hard X-ray emission in radio-quiet active galactic nuclei (AGNs) is believed to be produced via inverse Compton scattering by hot and compact coronae near the super massive black hole. However the origin and physical properties of the coronae, including geometry, kinematics and dynamics, yet remain poorly known. In this work, taking [OIV] 25.89um emission line as an isotropic indicator of AGN's intrinsic luminosity, we compare the intrinsic corona X-ray emission between Seyfert 1 and Compton-thin Seyfert 2 galaxies, which are viewed at different inclinations according to the unification scheme. We compile a sample of 130 Compton-thin Seyfert galaxies with both [OIV] 25.89um line luminosities measured with Spitzer-IRS and X-ray spectra observed by XMM-Newton, Chandra, Suzaku or Swift. Known radio-loud sources are excluded. We fit the X-ray spectra to obtain the absorption-corrected 2-10 keV continuum luminosities. We find that Seyfert 1 galaxies are intrinsically brighter in intrinsic 2-10 keV emission by a factor of 2.8+0.5-0.4 (2.2+0.9-0.3 in Swift-BAT 14-195 keV emission), comparing with Compton-thin Seyfert 2 galaxies. The Seyfert 1 and Compton-thin Seyfert 2 galaxies follow a statistically identical correlation between the absorption-corrected 2-10 keV luminosity and the 14-195 keV luminosity, indicating that our absorption correction to the 2-10 keV flux is sufficient. The difference in X-ray emission between the two populations is thus unlikely due to X-ray absorption, and instead implies an intrinsic anisotropy in the corona X-ray emission. This striking anisotropy of X-ray emission can be explained by a bipolar outflowing corona with a bulk velocity of ~0.3-0.5c. This would provide a natural link between the so-called coronae and weak jets in these systems. Other consequences of outflowing coronae are also discussed.

astro-ph.HE↗

EXSdetect: an end-to-end software for extended source detection in X-ray images: application to Swift-XRT data

Aims. We present a stand-alone software (named EXSdetect) for the detection of extended sources in X-ray images. Our goal is to provide a flexible tool capable of detecting extended sources down to the lowest flux levels attainable within instrumental limitations, while maintaining robust photometry, high completeness, and low contamination, regardless of source morphology. EXSdetect was developed mainly to exploit the ever-increasing wealth of archival X-ray data, but is also ideally suited to explore the scientific capabilities of future X-ray facilities, with a strong focus on investigations of distant groups and clusters of galaxies. Methods. EXSdetect combines a fast Voronoi tessellation code with a friends-of-friends algorithm and an automated deblending procedure. The values of key parameters are matched to fundamental telescope properties such as angular resolution and instrumental background. In addition, the software is designed to permit extensive tests of its performance via simulations of a wide range of observational scenarios. Results. We applied EXSdetect to simulated data fields modeled to realistically represent the Swift X-ray Cluster Survey (SXCS), which is based on archival data obtained by the X-ray telescope onboard the Swift satellite. We achieve more than 90% completeness for extended sources comprising at least 80 photons in the 0.5-2 keV band, a limit that corresponds to 10^-14 erg cm^-2 s^-1 for the deepest SXCS fields. This detection limit is comparable to the one attained by the most sensitive cluster surveys conducted with much larger X-ray telescopes. While evaluating the performance of EXSdetect, we also explored the impact of improved angular resolution and discuss the ideal properties of the next generation of X-ray survey missions.

astro-ph.IM↗

The X-ray Nature of Nucleus in Seyfert 2 Galaxy NGC 7590

We present the result of the Chandra high-resolution observation of the Seyfert~2 galaxy NGC 7590. This object was reported to show no X-ray absorption in the low-spatial resolution ASCA data. The XMM observations show that the X-ray emission of NGC 7590 is dominated by an off-nuclear ultra-luminous X-ray source (ULX) and an extended emission from the host galaxy, and the nucleus is rather weak, likely hosting a Compton-thick AGN. Our recent Chandra observation of NGC 7590 enables to remove the X-ray contamination from the ULX and the extended component effectively. The nuclear source remains undetected at ~4x10^{-15} erg/s/cm^-2 flux level. Although not detected, Chandra data gives a 2--10 keV flux upper limit of ~6.1x10^{-15} erg/s/cm^-2 (at 3 sigma level), a factor of 3 less than the XMM value, strongly supporting the Compton-thick nature of the nucleus. In addition, we detected five off-nuclear X-ray point sources within the galaxy D25 ellipse, all with 2 -- 10 keV luminosity above 2x10^{38} erg/s (assuming the distance of NGC 7590). Particularly, the ULX previously identified by ROSAT data was resolved by Chandra into two distinct X-ray sources. Our analysis highlights the importance of high spatial resolution images in discovering and studying ULXs.

astro-ph.HE↗

The Difference in Narrow Fe KαLine Emission Between Seyfert 1 and Seyfert 2 Galaxies

We compile a sample of 89 Seyfert galaxies with both [OIV] 25.89 um line luminosities observed by Spitzer IRS and X-ray spectra observed by XMM EPIC. Using [OIV] emission as proxy of AGN intrinsic luminosity, we find that although type 2 AGNs have higher line equivalent width, the narrow Fe Kalpha line in Compton-Thin and Compton-Thick Seyfert 2 galaxies are 2.9 +0.8 -0.6 and 5.6 +1.9 -1.4 times weaker in terms of luminosity than Seyfert 1 galaxies respectively. This indicates different correction factors need to be applied for various types of AGNs before the narrow Fe Kalpha line luminosity could serve as intrinsic AGN luminosity indicator. We also find Seyfert 1 galaxies in our sample have on average marginally larger line width and higher line centroid energy, suggesting contamination from highly ionized Fe line or broader line emission from much smaller radius, but this effect is too weak to explain the large difference in narrow Fe Kalpha line luminosity between type 1 and type 2 AGNs. This is the first observational evidence showing the narrow Fe Kalpha line emission in AGNs is anisotropic. The observed difference is consistent with theoretical calculations assuming a smoothly distributed obscuring torus, and could provide independent constraints on the clumpiness of the torus.

astro-ph.HE↗