arXiv Science⌕ Search

arXiv subjects

Tassilo Wald

Publications and source records attributed to Tassilo Wald.

At least 19 recordsLinked to original sources

Dataset Collections: Challenges of Large-Scale Data Aggregation in 3D Medical Image Datasets

The development of deep learning-based medical AI depends on high-quality annotated data. Yet, dataset creation remains constrained by the need for expert radiologist annotations, limiting curated datasets to relatively small cohorts. To overcome this limitation, recent efforts increasingly aggregate disparate public datasets into large-scale dataset collections. However, combining datasets at scale often obscures data provenance, introducing substantial risks of reuse propagation, unintended leakage, bias amplification and distorted data distributions. In this work, we study these problems on a massive collection of 565k 3D radiological images across 1034 public datasets and provide practical resources to address them. Firstly, we formalize dataset collections as a distinct paradigm in medical image analysis and characterize their structural challenges, including reuse propagation, duplication, and provenance fragmentation. Secondly, we perform a large-scale empirical study of duplication on this collection and demonstrate extensive exact and near-duplicate reuse across public datasets via perceptual hashing and manual tracing, identifying a lower bound of 118k duplicate pairs. We make the perceptual hashes publicly accessible for comparison through our website, providing researchers with a standardized reference for identifying potential overlaps and shared provenance. Thirdly, since hashing alone cannot detect all duplicates, we introduce MAP (Metadata for Aggregation and Provenance), a lightweight, portable metadata profile for documenting provenance, known overlaps, and deduplication decisions in dataset collections. Our contributions help dataset collections shift from coarse aggregations to reliable and provenance-aware data scaling mechanisms in medical image analysis. A web tool supporting our work is available at https://mic-dct.dkfz.de/.

eess.IV↗

Feature Space Guidance for Breast Cancer Classification in DCE-MRI

Dynamic contrast enhanced breast MRI (DCE-MRI) is a powerful clinical tool for breast cancer detection, providing high resolution anatomical detail together with rich temporal contrast information. However, high dimensional 4D inputs, small lesions, and heterogeneous acquisition protocols across clinical sites hinder robust automated classification of healthy, benign, and malignant cases. To address these challenges, we propose a framework that dynamically analyzes latent representations to adapt to protocol-specific characteristics. Spatial variability is mitigated by reducing confounding background uptake and compensating for misalignment caused by deformable soft tissue. Additionally, relationships in the latent space across phases are leveraged to select the most informative temporal features, improving robustness to protocol-specific temporal variability. Finally, task specific discriminative features are promoted through large scale supervised lesion segmentation pretraining, which substantially enhances downstream finetuning. Evaluated under leave-one-center-out validation on the ODELIA dataset and the held-out AMBL cohort, the proposed framework substantially outperforms finetuned radiology foundation models and prior methods, improving mean AUROC by nearly 8 points and balanced accuracy by 4 points over the strongest baseline. Additionally, our method achieved first place in the MICCAI ODELIA Breast MRI Challenge 2025, further demonstrating its effectiveness for robust breast cancer classification. We publicly release our codebase under https://github.com/MIC-DKFZ/CURIAtor.

cs.CV↗

nnFoundation: 3D Foundation Models for Radiology

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

cs.CV↗

Comprehensive language-image pre-training for 3D medical image understanding

In the 3D medical image domain, vision-language pre-training is used to create vision-language encoders (VLEs) that can support radiologists by retrieving patients with similar abnormalities, predicting likelihoods of abnormality, or, with downstream adaptation, generating radiological reports. While the methodology holds promise, three challenges limit the capabilities of current 3D VLEs: data scarcity due to privacy concerns, high computational costs resulting from the volumetric nature of the images, and a domain shift between the long reports used for training and the short prompts used during inference for, e.g., zero-shot classification. As a consequence, natural-image VLE recipes do not directly transfer to 3D medical imaging. In this paper, we overcome these challenges by injecting additional supervision via a report generation objective and combining vision-language with vision-only pre-training, allowing us to leverage both image-only and paired image-text 3D datasets. Further, we propose a novel loss that addresses the domain shift between long reports and short textual prompts. Through these additional objectives, paired with best practices of the 3D medical imaging domain, we develop the Comprehensive Language-Image Pre-training (COLIPRI) encoder family. Our COLIPRI encoders achieve state-of-the-art performance in report generation, semantic segmentation, classification probing, and zero-shot classification. The model weights and inference code are freely available at https://huggingface.co/microsoft/colipri.

cs.CV↗

Resolution Meets Reduction: Efficient Visual Context for 3D Radiology Report Generation

Vision-language models offer a promising path toward automating radiology report generation, but applying them to full 3D CT volumes poses substantial computational challenges. Modern foundation vision encoders (VEs) can produce tens of thousands of vision tokens per scan, making the visual sequence passed to the large language model (LLM) a primary computational bottleneck. Vision-to-language projectors can compress this sequence to reduce computation, but may discard clinically relevant detail; conversely, effective compression can accommodate higher-resolution inputs while keeping the downstream token count fixed. How this vision-token budget should be allocated across input field of view, spatial resolution, and vision-to-language projection therefore remains an open design question. We systematically evaluate four heterogeneous VEs (CNN- and ViT-based), five token-reducing projectors at up to 64x compression alongside a non-reducing MLP projector baseline, and five instruction-tuned LLMs (1.7B--4B) on two large-scale CT report datasets (CT-RATE and Merlin). At matched LLM token budgets, anatomy-guided region of interest cropping is the most consistent strategy, improving clinical macro F1 in 19 of 20 settings by +3.7 points on average for the 3D ViT Primus encoder and +1.1 for the slice-based 2D ViT Curia encoder. Increasing input resolution further is strongly projector-dependent: the PerceiverResampler, paired with higher-resolution Curia features, yields the strongest configuration in the resolution study on both datasets. Our best configurations achieve state-of-the-art clinical macro F1 on the test sets, reaching 49.5 on CT-RATE and 49.0 on Merlin. Code and models will be published upon publication.

cs.CV↗

Primus: Enforcing Attention Usage for 3D Medical Image Segmentation

Transformers have achieved remarkable success across multiple fields, yet their impact on 3D medical image segmentation remains limited with convolutional networks still dominating major benchmarks. In this work, (A) we analyze current Transformer-based segmentation models and identify critical shortcomings, particularly their over-reliance on convolutional blocks. Further, we demonstrate that in some architectures, performance is unaffected by the absence of the Transformer, thereby demonstrating their limited effectiveness. To address these challenges, we move away from hybrid architectures and (B) introduce Transformer-centric segmentation architectures, termed Primus and PrimusV2. Primus leverages high-resolution tokens, combined with advances in positional embeddings and block design, to maximally leverage its Transformer blocks, while PrimusV2 expands on this through an iterative patch embedding. Through these adaptations, Primus surpasses current Transformer-based methods and competes with a default nnU-Net while PrimusV2 exceeds it and is on par with the state-of-the-art CNNs such as ResEnc-L and MedNeXt architectures across nine public datasets. In doing so, we introduce the first competitive Transformer-centric model, making Transformers state-of-the-art in 3D medical image segmentation. The code is available here: https://github.com/MIC-DKFZ/nnUNet/blob/master/documentation/primus.md.

cs.CV↗

MedNeXt-v2: Scaling 3D ConvNeXts for Large-Scale Supervised Representation Learning in Medical Image Segmentation

Large-scale supervised pretraining is rapidly reshaping 3D medical image segmentation. However, existing efforts focus primarily on increasing dataset size and overlook the question of whether the backbone network is an effective representation learner at scale. In this work, we address this gap by revisiting ConvNeXt-based architectures for volumetric segmentation and introducing MedNeXt-v2, a compound-scaled 3D ConvNeXt that leverages improved micro-architecture and data scaling to deliver state-of-the-art performance. First, we show that routinely used backbones in large-scale pretraining pipelines are often suboptimal. Subsequently, we use comprehensive backbone benchmarking prior to scaling and demonstrate that stronger from scratch performance reliably predicts stronger downstream performance after pretraining. Guided by these findings, we incorporate a 3D Global Response Normalization module and use depth, width, and context scaling to improve our architecture for effective representation learning. We pretrain MedNeXt-v2 on 18k CT volumes and demonstrate state-of-the-art performance when fine-tuning across six challenging CT and MR benchmarks (144 structures), showing consistent gains over seven publicly released pretrained models. Beyond improvements, our benchmarking of these models also reveals that stronger backbones yield better results on similar data, representation scaling disproportionately benefits pathological segmentation, and that modality-specific pretraining offers negligible benefit once full finetuning is applied. In conclusion, our results establish MedNeXt-v2 as a strong backbone for large-scale supervised representation learning in 3D Medical Image Segmentation. Our code and pretrained models are made available with the official nnUNet repository at: https://www.github.com/MIC-DKFZ/nnUNet

eess.IV↗

The Missing Piece: A Case for Pre-Training in 3D Medical Object Detection

Large-scale pre-training holds the promise to advance 3D medical object detection, a crucial component of accurate computer-aided diagnosis. Yet, it remains underexplored compared to segmentation, where pre-training has already demonstrated significant benefits. Existing pre-training approaches for 3D object detection rely on 2D medical data or natural image pre-training, failing to fully leverage 3D volumetric information. In this work, we present the first systematic study of how existing pre-training methods can be integrated into state-of-the-art detection architectures, covering both CNNs and Transformers. Our results show that pre-training consistently improves detection performance across various tasks and datasets. Notably, reconstruction-based self-supervised pre-training outperforms supervised pre-training, while contrastive pre-training provides no clear benefit for 3D medical object detection. Our code is publicly available at: https://github.com/MIC-DKFZ/nnDetection-finetuning.

eess.IV↗

An OpenMind for 3D medical vision self-supervised learning

The field of self-supervised learning (SSL) for 3D medical images lacks consistency and standardization. While many methods have been developed, it is impossible to identify the current state-of-the-art, due to i) varying and small pretraining datasets, ii) varying architectures, and iii) being evaluated on differing downstream datasets. In this paper, we bring clarity to this field and lay the foundation for further method advancements through three key contributions: We a) publish the largest publicly available pre-training dataset comprising 114k 3D brain MRI volumes, enabling all practitioners to pre-train on a large-scale dataset. We b) benchmark existing 3D self-supervised learning methods on this dataset for a state-of-the-art CNN and Transformer architecture, clarifying the state of 3D SSL pre-training. Among many findings, we show that pre-trained methods can exceed a strong from-scratch nnU-Net ResEnc-L baseline. Lastly, we c) publish the code of our pre-training and fine-tuning frameworks and provide the pre-trained models created during the benchmarking process to facilitate rapid adoption and reproduction.

cs.CV↗

Large Scale Supervised Pretraining For Traumatic Brain Injury Segmentation

The segmentation of lesions in Moderate to Severe Traumatic Brain Injury (msTBI) presents a significant challenge in neuroimaging due to the diverse characteristics of these lesions, which vary in size, shape, and distribution across brain regions and tissue types. This heterogeneity complicates traditional image processing techniques, resulting in critical errors in tasks such as image registration and brain parcellation. To address these challenges, the AIMS-TBI Segmentation Challenge 2024 aims to advance innovative segmentation algorithms specifically designed for T1-weighted MRI data, the most widely utilized imaging modality in clinical practice. Our proposed solution leverages a large-scale multi-dataset supervised pretraining approach inspired by the MultiTalent method. We train a Resenc L network on a comprehensive collection of datasets covering various anatomical and pathological structures, which equips the model with a robust understanding of brain anatomy and pathology. Following this, the model is fine-tuned on msTBI-specific data to optimize its performance for the unique characteristics of T1-weighted MRI scans and outperforms the baseline without pretraining up to 2 Dice points.

cs.CV↗

Revisiting MAE pre-training for 3D medical image segmentation

Self-Supervised Learning (SSL) presents an exciting opportunity to unlock the potential of vast, untapped clinical datasets, for various downstream applications that suffer from the scarcity of labeled data. While SSL has revolutionized fields like natural language processing and computer vision, its adoption in 3D medical image computing has been limited by three key pitfalls: Small pre-training dataset sizes, architectures inadequate for 3D medical image analysis, and insufficient evaluation practices. In this paper, we address these issues by i) leveraging a large-scale dataset of 39k 3D brain MRI volumes and ii) using a Residual Encoder U-Net architecture within the state-of-the-art nnU-Net framework. iii) A robust development framework, incorporating 5 development and 8 testing brain MRI segmentation datasets, allowed performance-driven design decisions to optimize the simple concept of Masked Auto Encoders (MAEs) for 3D CNNs. The resulting model not only surpasses previous SSL methods but also outperforms the strong nnU-Net baseline by an average of approximately 3 Dice points setting a new state-of-the-art. Our code and models are made available here.

cs.CV↗

RadioActive: 3D Radiological Interactive Segmentation Benchmark

Effortless and precise segmentation with minimal clinician effort could greatly streamline clinical workflows. Recent interactive segmentation models, inspired by METAs Segment Anything, have made significant progress but face critical limitations in 3D radiology. These include impractical human interaction requirements such as slice-by-slice operations for 2D models on 3D data and a lack of iterative refinement. Prior studies have been hindered by inadequate evaluation protocols, resulting in unreliable performance assessments and inconsistent findings across studies. The RadioActive benchmark addresses these challenges by providing a rigorous and reproducible evaluation framework for interactive segmentation methods in clinically relevant scenarios. It features diverse datasets, a wide range of target structures, and the most impactful 2D and 3D interactive segmentation methods, all within a flexible and extensible codebase. We also introduce advanced prompting techniques that reduce interaction steps, enabling fair comparisons between 2D and 3D models. Surprisingly, SAM2 outperforms all specialized medical 2D and 3D models in a setting requiring only a few interactions to generate prompts for a 3D volume. This challenges prevailing assumptions and demonstrates that general-purpose models surpass specialized medical approaches. By open-sourcing RadioActive, we invite researchers to integrate their models and prompting techniques, ensuring continuous and transparent evaluation of 3D medical interactive models.

cs.CV↗

ReSi: A Comprehensive Benchmark for Representational Similarity Measures

Measuring the similarity of different representations of neural architectures is a fundamental task and an open research challenge for the machine learning community. This paper presents the first comprehensive benchmark for evaluating representational similarity measures based on well-defined groundings of similarity. The representational similarity (ReSi) benchmark consists of (i) six carefully designed tests for similarity measures, (ii) 24 similarity measures, (iii) 14 neural network architectures, and (iv) seven datasets, spanning over the graph, language, and vision domains. The benchmark opens up several important avenues of research on representational similarity that enable novel explorations and applications of neural architectures. We demonstrate the utility of the ReSi benchmark by conducting experiments on various neural network architectures, real world datasets and similarity measures. All components of the benchmark are publicly available and thereby facilitate systematic reproduction and production of research results. The benchmark is extensible, future research can build on and further expand it. We believe that the ReSi benchmark can serve as a sound platform catalyzing future research that aims to systematically evaluate existing and explore novel ways of comparing representations of neural architectures.

cs.LG↗

nnInteractive: Redefining 3D Promptable Segmentation

Accurate and efficient 3D segmentation is essential for both clinical and research applications. While foundation models like SAM have revolutionized interactive segmentation, their 2D design and domain shift limitations make them ill-suited for 3D medical images. Current adaptations address some of these challenges but remain limited, either lacking volumetric awareness, offering restricted interactivity, or supporting only a small set of structures and modalities. Usability also remains a challenge, as current tools are rarely integrated into established imaging platforms and often rely on cumbersome web-based interfaces with restricted functionality. We introduce nnInteractive, the first comprehensive 3D interactive open-set segmentation method. It supports diverse prompts-including points, scribbles, boxes, and a novel lasso prompt-while leveraging intuitive 2D interactions to generate full 3D segmentations. Trained on 120+ diverse volumetric 3D datasets (CT, MRI, PET, 3D Microscopy, etc.), nnInteractive sets a new state-of-the-art in accuracy, adaptability, and usability. Crucially, it is the first method integrated into widely used image viewers (e.g., Napari, MITK), ensuring broad accessibility for real-world clinical and research applications. Extensive benchmarking demonstrates that nnInteractive far surpasses existing methods, setting a new standard for AI-driven interactive 3D segmentation. nnInteractive is publicly available: https://github.com/MIC-DKFZ/napari-nninteractive (Napari plugin), https://www.mitk.org/MITK-nnInteractive (MITK integration), https://github.com/MIC-DKFZ/nnInteractive (Python backend).

cs.CV↗

LesionLocator: Zero-Shot Universal Tumor Segmentation and Tracking in 3D Whole-Body Imaging

In this work, we present LesionLocator, a framework for zero-shot longitudinal lesion tracking and segmentation in 3D medical imaging, establishing the first end-to-end model capable of 4D tracking with dense spatial prompts. Our model leverages an extensive dataset of 23,262 annotated medical scans, as well as synthesized longitudinal data across diverse lesion types. The diversity and scale of our dataset significantly enhances model generalizability to real-world medical imaging challenges and addresses key limitations in longitudinal data availability. LesionLocator outperforms all existing promptable models in lesion segmentation by nearly 10 dice points, reaching human-level performance, and achieves state-of-the-art results in lesion tracking, with superior lesion retrieval and segmentation accuracy. LesionLocator not only sets a new benchmark in universal promptable lesion segmentation and automated longitudinal lesion tracking but also provides the first open-access solution of its kind, releasing our synthetic 4D dataset and model to the community, empowering future advancements in medical imaging. Code is available at: www.github.com/MIC-DKFZ/LesionLocator

cs.CV↗

LNQ 2023 challenge: Benchmark of weakly-supervised techniques for mediastinal lymph node quantification

Accurate assessment of lymph node size in 3D CT scans is crucial for cancer staging, therapeutic management, and monitoring treatment response. Existing state-of-the-art segmentation frameworks in medical imaging often rely on fully annotated datasets. However, for lymph node segmentation, these datasets are typically small due to the extensive time and expertise required to annotate the numerous lymph nodes in 3D CT scans. Weakly-supervised learning, which leverages incomplete or noisy annotations, has recently gained interest in the medical imaging community as a potential solution. Despite the variety of weakly-supervised techniques proposed, most have been validated only on private datasets or small publicly available datasets. To address this limitation, the Mediastinal Lymph Node Quantification (LNQ) challenge was organized in conjunction with the 26th International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI 2023). This challenge aimed to advance weakly-supervised segmentation methods by providing a new, partially annotated dataset and a robust evaluation framework. A total of 16 teams from 5 countries submitted predictions to the validation leaderboard, and 6 teams from 3 countries participated in the evaluation phase. The results highlighted both the potential and the current limitations of weakly-supervised approaches. On one hand, weakly-supervised approaches obtained relatively good performance with a median Dice score of $61.0\%$. On the other hand, top-ranked teams, with a median Dice score exceeding $70\%$, boosted their performance by leveraging smaller but fully annotated datasets to combine weak supervision and full supervision. This highlights both the promise of weakly-supervised methods and the ongoing need for high-quality, fully annotated data to achieve higher segmentation performance.

cs.CV↗

Touchstone Benchmark: Are We on the Right Way for Evaluating AI Algorithms for Medical Segmentation?

How can we test AI performance? This question seems trivial, but it isn't. Standard benchmarks often have problems such as in-distribution and small-size test sets, oversimplified metrics, unfair comparisons, and short-term outcome pressure. As a consequence, good performance on standard benchmarks does not guarantee success in real-world scenarios. To address these problems, we present Touchstone, a large-scale collaborative segmentation benchmark of 9 types of abdominal organs. This benchmark is based on 5,195 training CT scans from 76 hospitals around the world and 5,903 testing CT scans from 11 additional hospitals. This diverse test set enhances the statistical significance of benchmark results and rigorously evaluates AI algorithms across various out-of-distribution scenarios. We invited 14 inventors of 19 AI algorithms to train their algorithms, while our team, as a third party, independently evaluated these algorithms on three test sets. In addition, we also evaluated pre-existing AI frameworks--which, differing from algorithms, are more flexible and can support different algorithms--including MONAI from NVIDIA, nnU-Net from DKFZ, and numerous other open-source frameworks. We are committed to expanding this benchmark to encourage more innovation of AI algorithms for the medical domain.

cs.CV↗

A Unified Framework for Foreground and Anonymization Area Segmentation in CT and MRI Data

This study presents an open-source toolkit to address critical challenges in preprocessing data for self-supervised learning (SSL) for 3D medical imaging, focusing on data privacy and computational efficiency. The toolkit comprises two main components: a segmentation network that delineates foreground regions to optimize data sampling and thus reduce training time, and a segmentation network that identifies anonymized regions, preventing erroneous supervision in reconstruction-based SSL methods. Experimental results demonstrate high robustness, with mean Dice scores exceeding 98.5 across all anonymization methods and surpassing 99.5 for foreground segmentation tasks, highlighting the efficacy of the toolkit in supporting SSL applications in 3D medical imaging for both CT and MRI images. The weights and code is available at https://github.com/MIC-DKFZ/Foreground-and-Anonymization-Area-Segmentation.

eess.IV↗