A New High-Intensity Source for Ultracold Neutrons

The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration has completed a new superthermal source for ultracold neutrons (UCNs) at TRIUMF. It uses neutrons from a spallation target driven by TRIUMF's %520-MeV main cyclotron. Heavy water and liquid deuterium serve as neutron moderators, and inelastic scattering inside superfluid $^4$He at around \qty{1.1}{\kelvin} slows the neutrons down to become ultracold. During commissioning runs with the completed source, including the deuterium moderator, up to $1.47(2)\times 10^7$ UCNs were detected in the experimental area after irradiating the target and accumulating UCNs in the source for \qty{60}{\second}. Up to \qty{6.75(3)e5} UCN/s were detected during continuous operation, more than at any other source in the world.

physics.ins-det

Initial Performance of the TUCAN Magnetically Shielded Room

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has commissioned a large magnetically shielded room to be used for measuring the neutron electric dipole moment (nEDM) to a precision of $10^{-27}~e\mathrm{cm}$. The room is composed of five layers of MuMetal and one layer of copper and sits within the $\lesssim 370~\mu\mathrm{T}$ ambient field produced by the TRIUMF cyclotron. Within this environment, the quasi-static shielding factor was measured to be $3.25(2) \times 10^4$ at $0.01~\mathrm{Hz}$ with an external peak-to-peak perturbation of $2~\mu\mathrm{T}$. Without the large ambient cyclotron field, the shielding factor improves to $3.75(4)\times 10^4$ at the same perturbation amplitude and frequency. After idealization in the cyclotron field, the residual field at the room center was $B = 1.8(2)~\mathrm{nT}$ and the vertical first-order gradient across the central 1~m$^3$ ($dB_{\mathrm{z}}/dz$) was $-279(64)~\mathrm{pT/m}$. With additional improvement to the idealization, and with active compensation, we expect the room to be adequate for a $10^{-27}~e\mathrm{cm}$ nEDM search.

physics.ins-det

Ultracold Neutron Guide-Coating Facility at U.Winnipeg

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm$^3$, corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm$^3$, corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

physics.ins-det

Initial results of the TRIUMF ultracold advanced neutron source

We report the first results on ultracold neutron production from a new spallation-driven superfluid $^4$He (He-II) source at TRIUMF, which is being prepared for a new, precise measurement of the neutron electric dipole moment. A total of $(9.3 \pm 0.8)\times 10^{5}$ ultracold neutrons were observed at a proton beam current of \SI{37}{\uA}, when the target was irradiated for a period of \SI{60}{\s}. The results are in fair agreement with expectations based on a detailed simulation of neutron transport and ultracold neutron source cryogenics. There is some indication that the new source might not be as limited by the conduction of heat through the He-II as originally expected. The results indicate that the source is likely to make its ultimate production goals, once the liquid deuterium cold moderator system is completed, with the expectation that $5.7\times 10^7$~UCNs would be detected in the same experiment with full liquid levels. This would, for example, correspond to delivery of $1.4\times 10^6$~UCNs delivered to each of two nEDM measurement cells, and a statistical uncertainty of $1\times 10^{-27}~e$cm on the neutron EDM in 280 days of running.

nucl-ex