arXiv ScienceSearch

arXiv subjects

T. Neep

Publications and source records attributed to T. Neep.

At least 19 recordsLinked to original sources

Optical effects in Gaseous Electron Multipliers (GEMs)

Optical time projection chambers (OTPCs) are well suited for applications that require the highest spatial resolution for particle track reconstruction. The MIGDAL experiment uses a glass GEM-based OTPC and observes a systematic excess in both the intensity and width of particle tracks in its optical readout, when compared with charge readout simulations. One hypothesis is that scintillation light produced inside a GEM hole during the avalanche propagates through the GEM substrate and exits neighboring holes. We present lab measurements testing this hypothesized optical broadening effect in three types of GEM substrates: glass, ceramic, and FR4. Our observations quantify this optical broadening and demonstrate it to be strongest in glass GEMs. Additionally, we use Geant4 simulations to both reproduce our observations and quantify optical broadening effects in realistic charge avalanches. Applying our glass GEM effects to simulated particle tracks yields increases of track intensity and widths by up to around 26% and 31%, respectively. This may explain the larger than expected intensity and track widths observed in the MIGDAL OTPC and is expected to be an observed effect in all GEM-based OTPCs.

physics.ins-det

Overlap-aware segmentation for topological reconstruction of obscured objects

The separation of overlapping objects presents a significant challenge in scientific imaging. While deep learning segmentation-regression algorithms can predict pixel-wise intensities, they typically treat all regions equally rather than prioritizing overlap regions where attribution is most ambiguous. Recent advances in instance segmentation show that weighting regions of pixel overlap in training can improve segmentation boundary predictions in regions of overlap, but this idea has not yet been extended to segmentation regression. We address this with Overlap-Aware Segmentation of ImageS (OASIS): a new segmentation-regression framework with a weighted loss function designed to prioritize regions of object-overlap during training, enabling extraction of pixel intensities and topological features from heavily obscured objects. We demonstrate OASIS in the context of the MIGDAL experiment, which aims to directly image the Migdal effect--a rare process where electron emission is induced by nuclear scattering--in a low-pressure optical time projection chamber. This setting poses an extreme test case, as the target for reconstruction is a faint electron recoil track which is often heavily-buried within the order(s)-of-magnitude brighter nuclear recoil track. Compared to unweighted segmentation regression, we demonstrate OASIS's novel overlap region-targeted loss function weight to be the single most important training weight for improving intensity and topological reconstructions of the low-energy electron tracks that tend to be most dominated by pixel overlap. Averaging over eight training campaigns, we further show the addition of overlap-targeted weights to improve median intensity reconstruction errors from -41.1% to -13.3% for these low-energy electrons. These performance gains demonstrate OASIS as a generalizable methodology for recovering obscured signals in overlap-dominated regions.

hep-ex

Accelerating Garfield++ with CUDA

Garfield++ is extensively used within the gaseous detector community for comprehensive detector simulations, supporting the full experimental life cycle from design to operation and calibration. The emergence of micro-pattern gaseous detectors has necessitated computationally intensive microscopic avalanche simulations. The acceleration of one of Garfield++'s most demanding algorithms, AvalancheMicroscopic, by porting it to graphics processing units using NVIDIA's CUDA framework is described. The modifications are integrated into the Garfield++ codebase and are accessible to end users with only minor adjustments to their existing code. Benchmark results demonstrate substantial speed-up, especially for high-gain avalanches involving thousands of electrons, thereby enabling more efficient and detailed detector simulations.

physics.ins-det

The ionization yield in a methane-filled spherical proportional counter

Spherical proportional counters (SPCs) are gaseous particle detectors sensitive to single ionization electrons in their target media, with large detector volumes and low background rates. The $\mbox{NEWS-G}$ collaboration employs this technology to search for low-mass dark matter, having previously performed searches with detectors at the Laboratoire Souterrain de Modane (LSM), including a recent campaign with a 135 cm diameter SPC filled with methane. While in situ calibrations of the detector response were carried out at the LSM, measurements of the mean ionization yield and fluctuations of methane gas in SPCs were performed using a 30 cm diameter detector. The results of multiple measurements taken at different operating voltages are presented. A UV laser system was used to measure the mean gas gain of the SPC, along with $\mathrm{^{37}Ar}$ and aluminum-fluorescence calibration sources. These measurements will inform the energy response model of future operating detectors.

physics.ins-det

Search for Light Dark Matter with NEWS-G at the Laboratoire Souterrain de Modane Using a Methane Target

The NEWS-G direct detection experiment uses spherical proportional counters to search for light dark matter candidates. New results from a 10 day physics run with a $135\,\mathrm{cm}$ in diameter spherical proportional counter at the Laboratoire Souterrain de Modane are reported. The target consists of $114\,\mathrm{g}$ of methane, providing sensitivity to dark matter spin-dependent coupling to protons. New constraints are presented in the mass range $0.17$ to $1.2\,\mathrm{GeV/c^2}$, with a 90% confidence level cross-section upper limit of $30.9\,\mathrm{pb}$ for a mass of $0.76\,\mathrm{GeV/c^2}$.

hep-ex

Transforming a rare event search into a not-so-rare event search in real-time with deep learning-based object detection

Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal effect, using high-resolution image data from a state-of-the-art scientific CMOS camera in the MIGDAL experiment. The Migdal effect in nuclear scattering, crucial for sub-GeV dark matter searches, has yet to be experimentally confirmed, making its detection a primary goal of the MIGDAL experiment. Our pipeline employs the YOLOv8 object detection algorithm and is trained on real data to enhance the detection efficiency of nuclear and electronic recoils, particularly those exhibiting overlapping tracks that are indicative of the Migdal effect. When deployed online on the MIGDAL readout PC, we demonstrate our pipeline to process and perform the rare event search on 2D image data faster than the peak 120 frame per second acquisition rate of the CMOS camera. Applying these same steps offline, we demonstrate that we can reduce a sample of 20 million camera frames to around 1000 frames while maintaining nearly all signal that YOLOv8 is able to detect, thereby transforming a rare search into a much more manageable search. Our studies highlight the potential of pipelines similar to ours significantly improving the detection capabilities of experiments requiring rapid and precise object identification in high-throughput data environments.

hep-ex

First operation of an ACHINOS-equipped Spherical Proportional Counter with individual anode read-out

The multi-anode sensor ACHINOS revolutionised the capabilities of the spherical proportional counter by enabling large-size, high-pressure, operation and TPC-like reconstruction capabilities through individual anode read-out. First measurements with an individually read out ACHINOS are performed, which enables improved calibration and response homogenisation. Experimental results demonstrating the improvement in energy resolution brought by the individual anode calibration are presented. These are complemented by detailed simulation studies on the effect of sensor design and manufacturing imperfections, and how they may be corrected both in hardware and analysis.

physics.ins-det

Performance of a spherical high pressure gas TPC for neutrino magnetic moment measurement

The measurement of neutrino magnetic moment larger than $10^{-19}\mu_B$ would be a clear signature of physics beyond the standard model other than the existence of massive Dirac neutrinos. The use of a spherical proportional counter detector filled with gas at 40 bar located near a nuclear reactor would be a simple way to perform such a measurement exploiting the developments made on such a technology for the search of dark matter and neutrinoless double beta decay. Different targets can be used just by replacing the gas: xenon, CF$_4$ and argon were compared and the sensitivity in one year of data taking could reach the level of $4.3 \times 10^{-12} \mu_B$, $6.5 \times 10^{-12} \mu_B$, and $8.5 \times 10^{-12} \mu_B$, respectively.

hep-ex

Exploring light dark matter with the DarkSPHERE spherical proportional counter electroformed underground at the Boulby Underground Laboratory

We present the conceptual design and the physics potential of DarkSPHERE, a proposed 3 m in diameter spherical proportional counter electroformed underground at the Boulby Underground Laboratory. This effort builds on the R&D performed and experience acquired by the NEWS-G Collaboration. DarkSPHERE is primarily designed to search for nuclear recoils from light dark matter in the 0.05--10 GeV mass range. Electroforming the spherical shell and the implementation of a shield based on pure water ensures a background level below 0.01 dru. These, combined with the proposed helium-isobutane gas mixture, will provide sensitivity to the spin-independent nucleon cross-section of $2\times 10^{-41} (2\times 10^{-43})$ cm$^2$ for a dark matter mass of $0.1 (1)$ GeV. The use of a hydrogen-rich gas mixture with a natural abundance of $^{13}$C provides sensitivity to spin-dependent nucleon cross-sections more than two orders of magnitude below existing constraints for dark matter lighter than 1 GeV. The characteristics of the detector also make it suitable for searches of other dark matter signatures, including scattering of MeV-scale dark matter with electrons, and super-heavy dark matter with masses around the Planck scale that leave extended ionisation tracks in the detector.

hep-ex

ACHINOS: A Multi-Anode Read-Out for Position Reconstruction and Tracking with Spherical Proportional Counters

The spherical proportional counter is a versatile gaseous detector with physics applications ranging from rare event searches to fast neutron spectroscopy. In its simplest form, the detector operates with a single channel read-out, and uses pulse-shape information to reconstruct the interaction radius, which is used for background discrimination and target volume definition. Recent developments in the read-out instrumentation have enabled the use of a multi-anode read-out structure, ACHINOS. The multiple anodes provide information about the interaction position which, coupled with the radial information, can be used to reconstruct an ionisation track. This ability has implications for several applications of the detector, for example, background discrimination in rare event searches.

physics.ins-det

Purification Efficiency and Radon Emanation of Gas Purifiers used with Pure and Binary Gas Mixtures for Gaseous Dark Matter Detectors

Rare event searches require extreme radiopurity in all detector components. This includes the active medium, which in the case of gaseous detectors, is the operating gas. The gases used typically include noble gas mixtures with molecular quenchers. Purification of these gases is required to achieve the desired detector performance, however, purifiers are known to emanate 222 Rn, which is a potential source of background. Several purifiers are studied for their O 2 and H 2 O purification efficiency and Rn emanation rates, aiming to identify the lowest-Rn options. Furthermore, the absorption of quenchers by the purifiers is assessed when used in a recirculating closed-loop gas system.

physics.ins-det

Fast Neutron Spectroscopy with a High-pressure Nitrogen-filled Large Volume Spherical Proportional Counter

We present a fast neutron spectroscopy system based on a nitrogen-filled, large volume gaseous detector, the Spherical Proportional Counter. The system has been successfully operated up to gas pressure of 1.5 bar. Neutron energy is estimated through measurement of the 14N(n,a)11B and 14N(n,p)14C reaction products. These reactions have comparable cross sections and Q-values with the 3He(n,p)3H reaction making nitrogen a good alternative to 3He use for fast neutron detection. Two detectors were built at the University of Birmingham and are currently used for the measurement of fast and thermal neutrons in the University of Birmingham and the Boulby underground laboratory, respectively.

hep-ex

Neutron spectroscopy: The case of the spherical proportional counter

Neutron spectroscopy is an invaluable tool for many scientific and industrial applications, including underground Dark Matter searches. Neutron-induced backgrounds produced by cosmic ray muons and the cavern radioactivity can mimic the expected Dark Matter signal. However, existing neutron detection methods have several drawbacks and limitations, thus measurements remain elusive. A promising new approach to neutron spectroscopy is the use of a nitrogen-filled spherical proportional counter that exploits the $^{14}$N(n,$\alpha$)$^{11}$B and $^{14}$N(n, p)$^{14}$C reactions. This is a safe, inexpensive, effective and reliable technique. In this work, the latest instrumentation developments are incorporated in a compact detector operated at the University of Birmingham (UoB) with high gain at gas pressure up to 1.8\,bar. We demonstrate spectroscopic measurements of thermalised and fast neutrons respectively from an $^{241}$Am-$^9$Be source and from the MC40 cyclotron facility at UoB. Additionally, the detector response to neutrons is simulated using a framework developed at UoB and compared with the experimental results.

physics.ins-det

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF$_4$. Initially, pure CF$_4$ will be used, and then in mixtures containing other elements employed by leading dark matter search technologies -- including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process -- an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF$_4$ we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D-D (D-T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5$\sigma$ median discovery significance can be achieved in under one day with either generator.

hep-ex

Neutron spectroscopy with a high-pressure nitrogen-filled spherical proportional counter

The spherical proportional counter is a large volume gaseous detector which finds application in several fields, including direct Dark Matter searches. When the detector is filled with nitrogen it becomes an effective neutron spectrometer thanks to the $^{14}$N(n,$\mathrm{\alpha}$)$^{11}$B and $^{14}$N(n,p)$^{14}$C reactions. Nitrogen, however, is a challenging operating gas for proportional counters and requires a high electric field strength to gas pressure ratio. Benefiting from the latest advances in spherical proportional counter instrumentation and simulation techniques, we report first neutron measurements at operating pressures of up to 1.8 bar. This achievement enhances the prospects of the spherical proportional counter to act as a neutron spectrometer appropriate for challenging environments, including underground laboratories, and industrial and medical settings.

physics.ins-det

Simultaneous scintillation light and charge readout of a pure argon filled Spherical Proportional Counter

The possible use of a Spherical Proportional Counter for the search of neutrinoless double beta decay is investigated in the R2D2 R&D project. Dual charge and scintillation light readout may improve the detector performance. Tests were carried out with pure argon at 1.1 bar using a 6x6 mm2 silicon photomultiplier. Scintillation light was used for the first time to trigger in a spherical proportional counter. The measured drift time is in excellent agreement with the expectations from simulations. Furthermore the light signal emitted during the avalanche development exhibits features that could be exploited for event characterisation.

physics.ins-det

Measurements of the ionization efficiency of protons in methane

The amount of energy released by a nuclear recoil ionizing the atoms of the active volume of detection appears "quenched" compared to an electron of the same kinetic energy. This different behavior in ionization between electrons and nuclei is described by the Ionization Quenching Factor (IQF) and it plays a crucial role in direct dark matter searches. For low kinetic energies (below $50~\mathrm{keV}$), IQF measurements deviate significantly from common models used for theoretical predictions and simulations. We report measurements of the IQF for proton, an appropriate target for searches of Dark Matter candidates with a mass of approximately 1 GeV, with kinetic energies in between $2~\mathrm{keV}$ and $13~\mathrm{keV}$ in $100~\mathrm{mbar}$ of methane. We used the Comimac facility in order to produce the motion of nuclei and electrons of controlled kinetic energy in the active volume, and a NEWS-G SPC to measure the deposited energy. The Comimac electrons are used as reference to calibrate the detector with 7 energy points. A detailed study of systematic effects led to the final results well fitted by $\mathrm{IQF}~(E_K)= E_K^\alpha~/~(\beta + E_K^\alpha)$ with $\alpha=0.70\pm0.08$ and $\beta = 1.32\pm0.17$. In agreement with some previous works in other gas mixtures, we measured less ionization energy than predicted from SRIM simulations, the difference reaching $33\%$ at $2~\mathrm{keV}$

physics.ins-det

Non-Parametric Data-Driven Background Modelling using Conditional Probabilities

Background modelling is one of the main challenges in particle physics data analysis. Commonly employed strategies include the use of simulated events of the background processes, and the fitting of parametric background models to the observed data. However, reliable simulations are not always available or may be extremely costly to produce. As a result, in many cases, uncertainties associated with the accuracy or sample size of the simulation are the limiting factor in the analysis sensitivity. At the same time, parametric models are limited by the a priori unknown functional form and parameter values of the background distribution. These issues become ever more pressing when large datasets become available, as it is already the case at the CERN Large Hadron Collider, and when studying exclusive signatures involving hadronic backgrounds. Two novel and widely applicable non-parametric data-driven background modelling techniques are presented, which address these issues for a broad class of searches and measurements. The first, relying on ancestral sampling, uses data from a relaxed event selection to estimate a graph of conditional probability density functions of the variables used in the analysis, accounting for significant correlations. A background model is then generated by sampling events from this graph, before the full event selection is applied. In the second, a generative adversarial network is trained to estimate the joint probability density function of the variables used in the analysis. The training is performed on a relaxed event selection which excludes the signal region, and the network is conditioned on a blinding variable. Subsequently, the conditional probability density function is interpolated into the signal region to model the background. The application of each method on a benchmark analysis is presented in detail, and the performance is discussed.

hep-ex