arXiv ScienceSearch

arXiv subjects

T. Lindner

Publications and source records attributed to T. Lindner.

At least 19 recordsLinked to original sources

A New High-Intensity Source for Ultracold Neutrons

The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration has completed a new superthermal source for ultracold neutrons (UCNs) at TRIUMF. It uses neutrons from a spallation target driven by TRIUMF's %520-MeV main cyclotron. Heavy water and liquid deuterium serve as neutron moderators, and inelastic scattering inside superfluid $^4$He at around \qty{1.1}{\kelvin} slows the neutrons down to become ultracold. During commissioning runs with the completed source, including the deuterium moderator, up to $1.47(2)\times 10^7$ UCNs were detected in the experimental area after irradiating the target and accumulating UCNs in the source for \qty{60}{\second}. Up to \qty{6.75(3)e5} UCN/s were detected during continuous operation, more than at any other source in the world.

physics.ins-det

Initial Performance of the TUCAN Magnetically Shielded Room

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has commissioned a large magnetically shielded room to be used for measuring the neutron electric dipole moment (nEDM) to a precision of $10^{-27}~e\mathrm{cm}$. The room is composed of five layers of MuMetal and one layer of copper and sits within the $\lesssim 370~\mu\mathrm{T}$ ambient field produced by the TRIUMF cyclotron. Within this environment, the quasi-static shielding factor was measured to be $3.25(2) \times 10^4$ at $0.01~\mathrm{Hz}$ with an external peak-to-peak perturbation of $2~\mu\mathrm{T}$. Without the large ambient cyclotron field, the shielding factor improves to $3.75(4)\times 10^4$ at the same perturbation amplitude and frequency. After idealization in the cyclotron field, the residual field at the room center was $B = 1.8(2)~\mathrm{nT}$ and the vertical first-order gradient across the central 1~m$^3$ ($dB_{\mathrm{z}}/dz$) was $-279(64)~\mathrm{pT/m}$. With additional improvement to the idealization, and with active compensation, we expect the room to be adequate for a $10^{-27}~e\mathrm{cm}$ nEDM search.

physics.ins-det

Ultracold Neutron Guide-Coating Facility at U.Winnipeg

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm$^3$, corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm$^3$, corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

physics.ins-det

Initial results of the TRIUMF ultracold advanced neutron source

We report the first results on ultracold neutron production from a new spallation-driven superfluid $^4$He (He-II) source at TRIUMF, which is being prepared for a new, precise measurement of the neutron electric dipole moment. A total of $(9.3 \pm 0.8)\times 10^{5}$ ultracold neutrons were observed at a proton beam current of \SI{37}{\uA}, when the target was irradiated for a period of \SI{60}{\s}. The results are in fair agreement with expectations based on a detailed simulation of neutron transport and ultracold neutron source cryogenics. There is some indication that the new source might not be as limited by the conduction of heat through the He-II as originally expected. The results indicate that the source is likely to make its ultimate production goals, once the liquid deuterium cold moderator system is completed, with the expectation that $5.7\times 10^7$~UCNs would be detected in the same experiment with full liquid levels. This would, for example, correspond to delivery of $1.4\times 10^6$~UCNs delivered to each of two nEDM measurement cells, and a statistical uncertainty of $1\times 10^{-27}~e$cm on the neutron EDM in 280 days of running.

nucl-ex

Neutron EDM Experiment with an Advanced Ultracold Neutron Source at TRIUMF

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has been developing a high-intensity ultracold neutron (UCN) source aimed at searching for the neutron electric dipole moment (EDM) with a sensitivity goal of $10^{-27}\ e{\rm cm}$. This article reports on recent progress in commissioning of the UCN source and in the development of the neutron EDM spectrometer. In its final configuration, the accelerator-driven super-thermal UCN source will enable a neutron EDM experiment with two orders of magnitude improved statistics compared to the current best experiment. Substantial progress in 2024 allowed the collaboration to operate the complete source system, with the exception of the liquid deuterium cold moderator, resulting in the first production of UCNs. The status of the EDM spectrometer is also presented, with emphasis on UCN handling components and magnetic subsystems relevant to field control, shielding, and magnetometry.

physics.ins-det

Cryogenic systems for the TUCAN EDM experiment

The TUCAN (TRIUMF UltraCold Advanced Neutron) Collaboration is completing a new ultracold neutron (UCN) source. The UCN source will deliver UCNs to a neutron electric dipole moment (EDM) experiment. The EDM experiment is projected to be capable of an uncertainty of $1\times 10^{-27}~e$cm, competitive with other planned projects, and a factor of ten more precise than the present world's best. The TUCAN source is based on a UCN production volume of superfluid helium (He-II), held at 1~K, and coupled to a proton-driven spallation target. The production rate in the source is expected to be in excess of $10^7$~UCN/s; since UCN losses can be small in superfluid helium, this should allow us to build up a large number of UCNs. The spallation-driven superfluid helium technology is the principal aspect making the TUCAN project unique. The superfluid production volume was recently cooled, for the first time, and successfully filled with superfluid helium. The design principles of the UCN source are described, along with some of the challenging cryogenic milestones that were recently passed.

physics.ins-det

Assembly, testing, and installation of mPMT photosensor for the Water Cherenkov Test Experiment

The multi-Photomultiplier Tube (mPMT) photosensors will be used in the Water Cherenkov Test Experiment (WCTE) to efficiently detect the photons produced in the whole detector. One of the aims behind the development of WCTE is to test the technology and implement it in future water Cherenkov experiments such as the Hyper-Kamiokande experiment and its Intermediate Water Cherenkov Detector. Each mPMT is built using nineteen 3-inch PMTs arranged on a semi-spherical support matrix. In this paper, we describe the design and manufacture of the mechanical components, the procedures for casting an optical gel between PMTs and acrylic cover, and the overall assembly procedure of the mPMTs. Details of the electronics used in the mPMT modules are not included in this paper and will be presented in a separate publication. We also report on the R&D performed on the selection of the optical gel ratio along with transmittance measurements and the reflectance measurements performed on the aluminium reflector. We also present the optical tests performed on the mPMT module using a 405 nm LED and the resulting increase in the effective photosensitive area by surrounding the PMTs with a reflector. A summary of the production and installation of the mPMTs for the WCTE is also presented in this paper.

physics.ins-det

Position Reconstruction in the DEAP-3600 Dark Matter Search Experiment

In the DEAP-3600 dark matter search experiment, precise reconstruction of the positions of scattering events in liquid argon is key for background rejection and defining a fiducial volume that enhances dark matter candidate events identification. This paper describes three distinct position reconstruction algorithms employed by DEAP-3600, leveraging the spatial and temporal information provided by photomultipliers surrounding a spherical liquid argon vessel. Two of these methods are maximum-likelihood algorithms: the first uses the spatial distribution of detected photoelectrons, while the second incorporates timing information from the detected scintillation light. Additionally, a machine learning approach based on the pattern of photoelectron counts across the photomultipliers is explored.

physics.ins-det

Precision Measurement of the Specific Activity of $^{39}$Ar in Atmospheric Argon with the DEAP-3600 Detector

The specific activity of the beta decay of $^{39}$Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of $^{39}$Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 $\pm$ 0.001 (stat) $\pm$ 0.024 (sys)] Bq/kg$_{\rm atmAr}$ which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.

physics.ins-det

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $\eta$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${\eta=3.5(5)\cdot10^{-4}}$.

nucl-ex

A measurement of proton-carbon forward scattering in a proof-of-principle test of the EMPHATIC spectrometer

The next generation of long-baseline neutrino experiments will be capable of precision measurements of neutrino oscillation parameters, precision neutrino-nucleus scattering, and unprecedented sensitivity to physics beyond the Standard Model. Reduced uncertainties in neutrino fluxes are necessary to achieve high precision and sensitivity in these future precise neutrino measurements. New measurements of hadron-nucleus interaction cross sections are needed to reduce uncertainties of neutrino fluxes. We report measurements of the differential cross-section as a function of scattering angle for proton-carbon interactions with a single charged particle in the final state at beam momenta of 20, 30, and 120 GeV/c. These measurements are the result of a beam test for EMPHATIC, a hadron-scattering and hadron-production experiment. The total, elastic and inelastic cross-sections are also extracted from the data and compared to previous measurements. These results can be used in current and future long-baseline neutrino experiments, and demonstrate the feasibility of future measurements by an upgraded EMPHATIC spectrometer.

physics.ins-det

Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD). We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors. The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.

physics.ins-det

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic

Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.

physics.med-ph

EMPHATIC: A proposed experiment to measure hadron scattering and productioncross sections for improved neutrino flux predictions

Hadron scattering and production uncertainties are a limiting systematic on accelerator and at-mospheric neutrino flux predictions. New hadron measurements are necessary for neutrino fluxpredictions with well-understood and reduced uncertainties. We propose a new compact experimentto measure hadron scattering and production cross sections at beam energies that are inaccessibleto currently operating experiments. These measurements can reduce the current 10% neutrino fluxuncertainties by an approximate factor of two.

hep-ex

A fast-switching magnet serving a spallation-driven ultracold neutron source

A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$\mu$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical operation mode of the TRIUMF cyclotron which delivers nearly continuous beam to multiple users. To enable the creation of the UCN facility, a beam-sharing arrangement with another facility was made. The beam sharing is accomplished by the fast-switching (kicker) magnet which is ramped in 50~$\mu$s to a current of 193~A, held there for approximately 1~ms, then ramped down in the same short period of time. This achieves a 12~mrad deflection which is sufficient to switch the proton beam between the two facilities. The kicker magnet relies on a high-current, low-inductance coil connected to a fast-switching power supply that is based on insulated-gate bipolar transistors (IGBTs). The design and performance of the kicker magnet system and initial beam delivery results are reported.

physics.acc-ph

Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB

DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.

astro-ph.CO

A beamline for fundamental neutron physics at TRIUMF

This article describes the new primary proton beamline 1U at TRIUMF. The purpose of this beamline is to produce ultracold neutrons (UCN) for fundamental-physics experiments. It delivers up to 40 microA of 480 MeV protons from the TRIUMF cyclotron to a tungsten spallation target and uses a fast kicker to share the beam between the Center for Molecular and Materials Science and UCN. The beamline has been successfully commissioned and operated with a beam current up to 10 microA, facilitating first large-scale UCN production in Canada.

physics.ins-det

First ultracold neutrons produced at TRIUMF

We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.