arXiv ScienceSearch

arXiv subjects

T. Higuchi

Publications and source records attributed to T. Higuchi.

At least 19 recordsLinked to original sources

A New High-Intensity Source for Ultracold Neutrons

The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration has completed a new superthermal source for ultracold neutrons (UCNs) at TRIUMF. It uses neutrons from a spallation target driven by TRIUMF's %520-MeV main cyclotron. Heavy water and liquid deuterium serve as neutron moderators, and inelastic scattering inside superfluid $^4$He at around \qty{1.1}{\kelvin} slows the neutrons down to become ultracold. During commissioning runs with the completed source, including the deuterium moderator, up to $1.47(2)\times 10^7$ UCNs were detected in the experimental area after irradiating the target and accumulating UCNs in the source for \qty{60}{\second}. Up to \qty{6.75(3)e5} UCN/s were detected during continuous operation, more than at any other source in the world.

physics.ins-det

Development for the Belle II vertex detector upgrade with depleted monolithic active pixel sensors

The vertex detector upgrade project for the Belle II experiment, based on CMOS depleted monolithic active pixel sensor technology, is planned to be carried out in conjunction with the major modification of the interaction region of the SuperKEKB collider during Long Shutdown 2 from 2032 to 2034. The MAPS sensor, named OBELIX currently under development, is derived from the successor to TJ-Monopix2, with modifications implemented to ensure compatibility with the Belle II trigger system. The new vertex detector consists of two layers of four self-supported consecutive OBELIX sensors, and three layers of discrete OBELIX sensors mounted on mechanical support structures with readout flex circuits attached to the sensors. The detector is arranged cylindrically around the beam pipe at radii ranging from 14 mm to 140 mm. The minimization of the material budget is required in order to enhance physics performance. We present an overview of the project and its latest developments, with particular emphasis on the development of low-material-budget flex circuits employing aluminum conductors.

physics.ins-det

Direct-V2X Support with 5G Network-based Communications: Performance, Challenges and Solutions

This study analyzes the feasibility of supporting critical V2X services using 5G network-based Vehicle-to-Network-to-Vehicle (V2N2V) communications. The study evaluates the end-to-end latency of 5G V2N2V communications under different network deployments in single and multi-operator scenarios. The study shows that critical V2X services can be supported using 5G V2N2V communications over MEC-based network deployments. However, this requires the use of local peering points and shared data centers or MEC federation to address challenges arising from asymmetric network deployments. This opens the possibility for V2N2V communications to complement direct Vehicle-to-Vehicle (V2V) connections for increased reliability or to offload traffic under sidelink network congestion.

cs.NI

Application of exhaustive simulation flow for advanced performance prediction of monolithic active pixel sensors

Monolithic active pixel sensor (MAPS) developments have pushed the detection performance in various directions, especially relative to timing where nanosecond-level precision is now considered. This evolution calls for a simultaneous upgrade of the simulation tools. We have developed a simulation flow that covers steps from the signal creation in the sensitive volume to the output of the pixel digital logic that performs the time-of-arrival and time-over-threshold (ToA/ToT) measurements. This approach adds several new features to the traditional use the of the TCAD - Allpix Squared duo, among which : the integration of the pixel wells from the layout in order to precisely describe the pixel key characteristics such as leakage and punch-through currents and the coupling of Monte Carlo simulations (Allpix Squared) with high precision electrical simulations (SPICE). The first (Allpix Squared) for the precise description of the current induced at the collection electrode and the second (SPICE) to guarantee high precision simulation of the front-end electronics using realistic signal events. Irradiation is also modeled, both from the charge propagation side (charge trapping) and from the front-end response side (high input signal discharge). We have applied this methodology to the MAPS developed in the context of the Belle II vertex detector upgrade. In this contribution, we detail the key features of the exhaustive simulation flow, present the outcome of the comparison with the TJ-Monopix2 measurements and discuss the interest of the methodology for the development of modern MAPS.

physics.ins-det

Initial Performance of the TUCAN Magnetically Shielded Room

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has commissioned a large magnetically shielded room to be used for measuring the neutron electric dipole moment (nEDM) to a precision of $10^{-27}~e\mathrm{cm}$. The room is composed of five layers of MuMetal and one layer of copper and sits within the $\lesssim 370~\mu\mathrm{T}$ ambient field produced by the TRIUMF cyclotron. Within this environment, the quasi-static shielding factor was measured to be $3.25(2) \times 10^4$ at $0.01~\mathrm{Hz}$ with an external peak-to-peak perturbation of $2~\mu\mathrm{T}$. Without the large ambient cyclotron field, the shielding factor improves to $3.75(4)\times 10^4$ at the same perturbation amplitude and frequency. After idealization in the cyclotron field, the residual field at the room center was $B = 1.8(2)~\mathrm{nT}$ and the vertical first-order gradient across the central 1~m$^3$ ($dB_{\mathrm{z}}/dz$) was $-279(64)~\mathrm{pT/m}$. With additional improvement to the idealization, and with active compensation, we expect the room to be adequate for a $10^{-27}~e\mathrm{cm}$ nEDM search.

physics.ins-det

Ultracold Neutron Guide-Coating Facility at U.Winnipeg

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm$^3$, corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm$^3$, corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

physics.ins-det

Radiation damage study of Belle II silicon strip sensors with 90 MeV electron irradiation

The silicon strip sensors of the Belle II silicon vertex detector were irradiated with 90 MeV electron beams up to an equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. We measure changes in sensor properties induced by radiation damage in the semiconductor bulk. Electrons around this energy are a major source of beam-induced background during Belle II operation. We discuss observed changes in full depletion voltage, sensor leakage current, noise, and charge collection. The sensor bulk type inverts at an equivalent 1-MeV-neutron fluence of $6.0\times 10^{12}~{\rm n}_{\rm eq}/{\rm cm^2}$. The leakage current increases proportionally to the radiation dose. We determine a damage constant of $3.9 \times 10^{-17}$ A/cm at 17 C$^\circ$ immediately after irradiation, which drops significantly to approximately 40% of the initial value in 200 hours, then stabilizes to approximately 30% of the initial value in 1000 hours. We measure sensor noise and signal charge for a sensor irradiated with the equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. Noise increases by approximately 44% after irradiation, while signal charge does not change significantly when a sufficiently high bias voltage is applied.

physics.ins-det

Initial results of the TRIUMF ultracold advanced neutron source

We report the first results on ultracold neutron production from a new spallation-driven superfluid $^4$He (He-II) source at TRIUMF, which is being prepared for a new, precise measurement of the neutron electric dipole moment. A total of $(9.3 \pm 0.8)\times 10^{5}$ ultracold neutrons were observed at a proton beam current of \SI{37}{\uA}, when the target was irradiated for a period of \SI{60}{\s}. The results are in fair agreement with expectations based on a detailed simulation of neutron transport and ultracold neutron source cryogenics. There is some indication that the new source might not be as limited by the conduction of heat through the He-II as originally expected. The results indicate that the source is likely to make its ultimate production goals, once the liquid deuterium cold moderator system is completed, with the expectation that $5.7\times 10^7$~UCNs would be detected in the same experiment with full liquid levels. This would, for example, correspond to delivery of $1.4\times 10^6$~UCNs delivered to each of two nEDM measurement cells, and a statistical uncertainty of $1\times 10^{-27}~e$cm on the neutron EDM in 280 days of running.

nucl-ex

Neutron EDM Experiment with an Advanced Ultracold Neutron Source at TRIUMF

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has been developing a high-intensity ultracold neutron (UCN) source aimed at searching for the neutron electric dipole moment (EDM) with a sensitivity goal of $10^{-27}\ e{\rm cm}$. This article reports on recent progress in commissioning of the UCN source and in the development of the neutron EDM spectrometer. In its final configuration, the accelerator-driven super-thermal UCN source will enable a neutron EDM experiment with two orders of magnitude improved statistics compared to the current best experiment. Substantial progress in 2024 allowed the collaboration to operate the complete source system, with the exception of the liquid deuterium cold moderator, resulting in the first production of UCNs. The status of the EDM spectrometer is also presented, with emphasis on UCN handling components and magnetic subsystems relevant to field control, shielding, and magnetometry.

physics.ins-det

Cryogenic systems for the TUCAN EDM experiment

The TUCAN (TRIUMF UltraCold Advanced Neutron) Collaboration is completing a new ultracold neutron (UCN) source. The UCN source will deliver UCNs to a neutron electric dipole moment (EDM) experiment. The EDM experiment is projected to be capable of an uncertainty of $1\times 10^{-27}~e$cm, competitive with other planned projects, and a factor of ten more precise than the present world's best. The TUCAN source is based on a UCN production volume of superfluid helium (He-II), held at 1~K, and coupled to a proton-driven spallation target. The production rate in the source is expected to be in excess of $10^7$~UCN/s; since UCN losses can be small in superfluid helium, this should allow us to build up a large number of UCNs. The spallation-driven superfluid helium technology is the principal aspect making the TUCAN project unique. The superfluid production volume was recently cooled, for the first time, and successfully filled with superfluid helium. The design principles of the UCN source are described, along with some of the challenging cryogenic milestones that were recently passed.

physics.ins-det

Operational experience and performance of the Silicon Vertex Detector after the first long shutdown of Belle II

In 2024, the Belle II experiment resumed data taking after the Long Shutdown 1, which was required to install a two-layer pixel detector and upgrade accelerator components. We describe the challenges of this shutdown and the operational experience thereafter. With new data, the silicon-strip vertex detector (SVD) confirmed the high hit efficiency, the large signal-to-noise ratio, and the excellent cluster position resolution. In the coming years, the SuperKEKB peak luminosity is expected to increase to its target value, resulting in a larger SVD occupancy caused by beam background. Considerable efforts have been made to improve SVD reconstruction software by exploiting the excellent SVD hit-time resolution to determine the collision time and reject off-time particle hits. A novel procedure to group SVD hits event-by-event, based on their time, has been developed using the grouping information during reconstruction, significantly reducing the fake rate while preserving the tracking efficiency. The front-end chip (APV25) is operated in the multi-peak mode, which reads six samples. A 3/6-mixed acquisition mode, based on the timing precision of the trigger, reduces background occupancy, trigger dead-time, and data size. Studies of the radiation damage show that the SVD performance will not seriously degrade during the lifetime of the detector, despite moderate radiation-induced increases in sensor current and strip noise.

physics.ins-det

Development of a bipolar 50 V output digital-to-analog converter system for ion-shuttling operations

The quantum charge-coupled device (QCCD) is one of the notable architectures to achieve large-scale trapped-ion quantum computers. To realize QCCD architecture, ions must be transported quickly while minimizing motional excitation. High-voltage sources are necessary to achieve such high-quality ion transport through a high secular frequency. In this study, we report the development of a field programmable gate array (FPGA)-based digital-to-analog converter (DAC) system with an output voltage range of +/-50 V and demonstrate its effectiveness in ion transport operations. The device provides 16-channel analog output, maximum update rate of 16 mega updates per second (MUPS), slew rate of 20 V/us, and bandwidth of > 200 kHz. By optimizing the voltage sets with quadratic programming, we experimentally confirmed that this DAC system can achieve more than twice the secular frequency attainable when its output range is restricted to +/-10 V, which is consistent with the fact that scaling all electrode voltages by a factor of 5 will scale the secular frequency by the square root of 5. Since the output range of many commercially available DACs is commonly limited to +/-10 V, this increase is effective for ion shuttling operations, such as transport, split and merge. The developed DAC system has potential to increase the speed of ion transport thereby reducing processing times in QCCD-based quantum computers.

quant-ph

The Belle II Detector Upgrades Framework Conceptual Design Report

We describe the planned near-term and potential longer-term upgrades of the Belle II detector at the SuperKEKB electron-positron collider operating at the KEK laboratory in Tsukuba, Japan. These upgrades will allow increasingly sensitive searches for possible new physics beyond the Standard Model in flavor, tau, electroweak and dark sector physics that are both complementary to and competitive with the LHC and other experiments.

hep-ex

Silicon Vertex Detector of the Belle II Experiment

The silicon vertex detector (SVD) is installed at the heart of the Belle II experiment, taking data at the high-luminosity $B$-Factory SuperKEKB since 2019. The detector has shown a stable and above-99\% hit efficiency, with a large signal-to-noise in all sensors since the beginning of data taking. Cluster position and time resolution have been measured with 2020 and 2022 data and show excellent performance and stability. The effect of radiation damage is visible, but not affecting the performance. As the luminosity increases, higher machine backgrounds are expected and the excellent hit-time information in SVD can be exploited for background rejection. In particular, we have recently developed a novel procedure to select hits by grouping them event-by-event based on their time. This new procedure allows a significant reduction of the fake rate, while preserving the tracking efficiency, and it has therefore replaced the previous cut-based procedure. We have developed a method that uses the SVD hits to estimate the track time (previously unavailable) and the collision time. It has a similar precision to the estimate based on the drift chamber but its execution time is three orders of magnitude smaller, allowing a faster online reconstruction that is crucial in a high luminosity regime. The track time is a powerful information provided to analysis that allows, together with the above-mention grouping selection, to raise the occupancy limit above that expected at nominal luminosity, leaving room for a safety factor. Finally, in June 2022 the data taking of the Belle II experiment was stopped to install a new two-layer DEPFET detector (PXD) and upgrade components of the accelerator. The whole silicon tracker (PXD+SVD) has been extracted from Belle II, the new PXD installed, the detector closed and commissioned. We briefly describe the SVD results of this upgrade.

hep-ex

A 16 Parts per Trillion Comparison of the Antiproton-to-Proton q/m Ratios

The Standard Model (SM) of particle physics is both incredibly successful and glaringly incomplete. Among the questions left open is the striking imbalance of matter and antimatter in the observable universe which inspires experiments to compare the fundamental properties of matter/antimatter conjugates with high precision. Our experiments deal with direct investigations of the fundamental properties of protons and antiprotons, performing spectroscopy in advanced cryogenic Penning-trap systems. For instance, we compared the proton/antiproton magnetic moments with 1.5 ppb fractional precision, which improved upon previous best measurements by a factor of >3000. Here we report on a new comparison of the proton/antiproton charge-to-mass ratios with a fractional uncertainty of 16ppt. Our result is based on the combination of four independent long term studies, recorded in a total time span of 1.5 years. We use different measurement methods and experimental setups incorporating different systematic effects. The final result, $-(q/m)_{\mathrm{p}}/(q/m)_{\bar{\mathrm{p}}}$ = $1.000\,000\,000\,003 (16)$, is consistent with the fundamental charge-parity-time (CPT) reversal invariance, and improves the precision of our previous best measurement by a factor of 4.3. The measurement tests the SM at an energy scale of $1.96\cdot10^{-27}\,$GeV (C$.$L$.$ 0.68), and improves 10 coefficients of the Standard Model Extension (SME). Our cyclotron-clock-study also constrains hypothetical interactions mediating violations of the clock weak equivalence principle (WEP$_\text{cc}$) for antimatter to a level of $|\alpha_{g}-1| < 1.8 \cdot 10^{-7}$, and enables the first differential test of the WEP$_\text{cc}$ using antiprotons \cite{hughes1991constraints}. From this interpretation we constrain the differential WEP$_\text{cc}$-violating coefficient to $|\alpha_{g,D}-1|<0.030$.

physics.atom-ph

A diffuse scattering model of ultracold neutrons on wavy surfaces

Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source at J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than $\pm 6^{\circ}$ was directed into a guide tube with a mean-square roughness of 6.4 nm to 17 nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability $p_{L} = 0.039\pm0.003$ reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10 nm.

physics.ins-det

Measurement of the cluster position resolution of the Belle II Silicon Vertex Detector

The Silicon Vertex Detector (SVD), with its four double-sided silicon strip sensor layers, is one of the two vertex sub-detectors of Belle II operating at SuperKEKB collider (KEK, Japan). Since 2019 and the start of the data taking, the SVD has demonstrated a reliable and highly efficient operation, even running in an environment with harsh beam backgrounds that are induced by the world's highest instantaneous luminosity. In order to provide the best quality track reconstruction with an efficient pattern recognition and track fit, and to correctly propagate the uncertainty on the hit's position to the track parameters, it is crucial to precisely estimate the resolution of the cluster position measurement. Several methods for estimating the position resolution directly from the data will be discussed.

physics.ins-det

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $\eta$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${\eta=3.5(5)\cdot10^{-4}}$.

nucl-ex