arXiv ScienceSearch

arXiv subjects

Sven Herrmann

Publications and source records attributed to Sven Herrmann.

At least 19 recordsLinked to original sources

VERITAS 2.3.1: Optimisation and Characterisation of the Enhanced Readout ASIC for the NewAthena Wide Field Imager

VERITAS 2.3.1 is the next iteration of the VErsatile Readout based on Integrated Trapezoidal Analogue Shapers (VERITAS) integrated circuit (IC) architecture for high-speed, low-noise readout of DEPleted Field Effect Transistor (DEPFET) detectors in the Wide Field Imager (WFI) on ESA's NewAthena X-ray satellite. Building on VERITAS 2.3, which demonstrated a short processing time of 2.5 us per readout and a system noise target of about 3 e- ENC RMS, the VERITAS 2.3.1 revision has been improved with additional features and targeted optimisations of existing analogue and digital blocks, alongside refined layout routing to reduce parasitic effects, to improve transient behavior, cross talk, manufacturability, and reliability while preserving the proven VERITAS architecture. The functionality and performance of VERITAS 2.3.1 was characterised in two steps. First by using a dedicated application specific integrated circuit (ASIC) only test setup. Second, a full scale module test setup is used, with integrated DEPFET sensors and readout electronics, under vacuum and at mission like temperatures. This paper presents the design updates and implementation details of the VERITAS 2.3.1, compares its measured performance to that of VERITAS 2.3, and discusses the impact of the added features, block-level optimisations, and routing improvements on overall system performance.

astro-ph.IM

Fast, low noise, megapixel detector and readout systems for future X-ray astronomy missions

Next-generation strategic X-ray astronomy missions will require the simultaneous achievement of high angular resolution, large effective collecting area, and wide-field imaging with large-format focal plane detectors. Realizing the associated science objectives--ranging from precision measurements of bright point sources to the detection and characterization of faint diffuse emission-places stringent and, in some cases, competing requirements on detector performance. In particular, high frame rates are necessary to mitigate photon pile-up in observations of bright sources and to reduce contamination from particle-induced background in measurements of low surface brightness structures. At the same time, these instruments must preserve excellent soft X-ray response, which places tight constraints on read noise and on the fidelity of event characterization. State-of-the-art X-ray charge-coupled devices (CCDs) approach many of the key performance metrics required for these missions, but readout speed remains a primary limitation. Addressing this gap requires readout architectures that scale to high channel count, sustain high pixel throughput, and preserve the low-noise characteristics needed for soft X-ray sensitivity.

astro-ph.IM

High-speed, low-noise, multi-megapixel CCDs for next generation X-ray observatories

Next generation X-ray observatories require fast, low-noise, low-power, multi-megapixel imaging spectrometers. To meet these demands, the X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in partnership with the MIT Kavli Institute and MIT Lincoln Laboratory (MIT-LL), is developing multi-channel X-ray charge-coupled devices (CCDs) and fast readout architectures. We report the energy resolution and noise performance achieved with a full-scale (1440x1440-pixel), 16-channel, front-illuminated MIT-LL CCD detector developed for the Advanced X-ray Imaging Satellite (AXIS) concept, the CCID-100, read out using two Multi-Channel Readout Chip (MCRC) V1 application-specific integrated circuit (ASIC) chips in the new Stanford CCID-100 test setup. We describe an automated method for bias optimization on each CCD channel, and integrated debugging features of the front-end ASIC and readout system. The demonstrated performance confirms that these systems can meet the speed and noise requirements of future strategic X-ray missions.

astro-ph.IM

Advancing X-Ray Camera Front-End Electronics Architecture through the AXIS-TAP Technology Platform

Advancing time-domain soft X-ray astronomy demands focal plane readout electronics capable of high-speed digitization with low noise while maintaining spectral fidelity across multiple detector channels. The Advanced X-ray Imaging Satellite (AXIS), a NASA Probe-class mission concept, provided the driving requirements and heritage for developing a generalized high-speed (>=5 fps) camera Front-End Electronics (FEE) architecture applicable to future soft X-ray missions. The FEE architecture defines a modular, dual-box redundant configuration to operate a focal plane of four 16-channel CCDs, with functional partitioning for power distribution, thermal management, mechanism control, and image data acquisition and transmission to the spacecraft. To validate the core signal chain architecture, particularly the analog-to-digital conversion, FPGA-based processing, and Ethernet data transmission, a dedicated technology demonstrator, AXIS-TAP (ADC Testing and Acquisition Platform), has been designed and is currently in fabrication. AXIS-TAP employs commercial equivalents of radiation-tolerant components (FPGA, ADCs, Ethernet PHY) and interfaces directly with the STA Archon benchtop readout system, enabling simultaneous image acquisition from both systems to validate that the flight-like architecture achieves equivalent or superior noise performance. This paper presents the FEE architectural framework, the AXIS-TAP demonstrator design, and the design principles that enable scalability to future soft X-ray missions with similar detector requirements. Performance validation results will be reported upon completion of AXIS-TAP system integration and testing.

astro-ph.IM

Output-Stage Design Optimization for High-Sensitivity SiSeRO CCDs and SiSeRO Active Pixel Sensors

The Single electron Sensitive Read Out (SiSeRO) technology is a new device class designed to support the needs of future X-ray and optical astronomical telescopes that will require fast, low-noise, megapixel spectro-imagers. Developed at MIT Lincoln Laboratory, in collaboration with Stanford University and MIT, the first generation SiSeRO-CCD (charge-coupled device) prototypes achieved a charge/current conversion gain of 700$-$800 pA per electron, an equivalent noise charge (ENC) of around 3.5 electrons root mean square (RMS), and a full width half maximum (FWHM) energy resolution of approximately 130 eV at 5.9 keV at a readout speed of 625 kpix/s. Utilizing Repetitive Non-Destructive Readout (RNDR), these same devices also demonstrated sub-electron noise performance (ENC$<$0.5 electrons RMS) at a readout speed of 10 kpix/s. We present the results of device simulations for next-generation SiSeRO CCD output stages that optimize the sensing transistor and its internal gate geometry to enhance noise and speed performance. Further, the goal is to develop a SiSeRO active pixel sensor (APS) that combines the proven X-ray performance of CCDs with the architectural advantages of an APS. Enabling this requires substantial design updates, for example, incorporating two SiSeRO amplifiers side by side on each pixel and shuffling the charge between them to support RNDR. We discuss our device simulation framework and design parameter optimization in the first-generation SiSeRO devices.

astro-ph.IM

Fast, low-noise CCD systems for future strategic X-ray missions

Future strategic X-ray missions, such as those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and noise capabilities required by such programs, our Stanford team, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing enhanced X-ray charge-coupled devices (CCDs) and readout systems that leverage tailored application-specific integrated circuits (ASICs). Here, we report the energy resolution and noise performance achieved using some of the latest MIT-LL CCDs in conjunction with Stanford-developed Multi-Channel Readout Chip (MCRC) ASICs. Additionally, we present a new sampling method for simultaneous optimization of the output gate (OG), reset gate (RG), and reset drain (RD) biases which, in combination with new integrated fast summing well (SW) and RG clock operation modes, enables the data rates and noise required for future X-ray telescopes. Finally, we present noise power spectral density (PSD) and waveform analysis methods and posit a physical model for characterizing and understanding output stage noise behavior.

astro-ph.IM

The High-Speed FPGA Readout System for the Advanced X-ray Imaging Satellite (AXIS)

The Advanced X-ray Imaging Satellite (AXIS) is a Probe-class mission concept designed to deliver arcsecond spatial resolution, high-sensitivity spectral imaging across the 0.3-10 keV band. The X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing the AXIS X-ray camera, including both the detector and the front-end readout electronics required to meet the mission's demanding performance goals. The telescope's focal plane detector consists of four 1440x1440 pixel charge-coupled devices (CCDs) developed by MIT-LL, each featuring 16 parallel output channels. These outputs are amplified by a high-speed, low-power, low-noise application-specific integrated circuit (ASIC) - the Multi-Channel Readout Chip (MCRC) - developed at Stanford. Following amplification, the analog signals are digitized and processed to construct a pixel array, prior to event detection. Here, we present the field-programmable gate array (FPGA) architecture developed to enable high-speed, parallelized readout of these CCD channels. The FPGA samples 16 analog-to-digital converter (ADC) channels at 50 MHz, performs preprocessing of pixel data, which is then streamed via User Datagram Protocol (UDP) over a 1 Gb Ethernet link to the back-end system for event reconstruction. Our design demonstrates the goal readout performance for AXIS (20 frames per second) and provides a framework for future high-throughput X-ray observatories.

astro-ph.IM

RNDR noise modeling in first-generation Single electron Sensitive Readout (SiSeRO) devices

Flagship observatories require single-photon detectors with ultra-fast readout, sub-electron noise performance, and scalable large-format architectures. The X-ray Astronomy and Observational Cosmology group at Stanford, in collaboration with the MIT Kavli Institute and MIT Lincoln Laboratory, is developing readout technologies for next-generation detectors. Prototypes employing Single-electron Sensitive Readout (SiSeRO) amplifiers demonstrate excellent read noise and spectral performance using repetitive non-destructive readout (RNDR), achieving 0.5 e$^-$ noise in under 57 cycles. We have modeled noise for longer RNDR cycles, exploring probabilistic mechanisms such as thermal leakage and impact ionization. Here we present our model results, including statistical limits on dark current-like signals. Maturation of SiSeRO technology will improve detector performance at soft X-ray energies, addressing technology gaps for future X-ray and UV/visible/near-IR observatories.

astro-ph.IM

First results for second generation SiSeRO CCD devices

The Astro2020 Decadal recommended the development of a suite of next generation astronomical observatories spanning the X-ray to near-IR spectrum. These programs require fast, extremely low noise detectors to fulfill their science goals. To address this technology gap, Stanford X-ray Astronomy and Observational Cosmology (XOC) group, MIT Lincoln Laboratory (MIT-LL), and MIT Kavli Institute (MKI) are advancing Single electron Sensitive Read Out (SiSeRO), a multiband detector technology capable of achieving substantially sub-electron noise via Repetitive Non-Destructive Readout (RNDR). We present initial results for our second generation SiSeRO CCDs. We also discuss our test bed, including a readout electronics system capable of accommodating all second-generation SiSeRO CCD variants utilizing the XOC-designed Multi-Channel Readout Chip (MCRC) ASIC.

astro-ph.IM

Joint Estimation of Properties of the Lunar Subsurface and Galactic Foregrounds with LuSEE-Night

The Lunar Surface Electromagnetics Experiment (LuSEE-Night) is a joint NASA-DOE-ESA low-frequency radio telescope that will reach the lunar far side in 2027. The unknown dielectric properties of the subsurface at the LuSEE-Night landing site impose the most significant limitation for precision instrument calibration, as reflections from the lunar subsurface can change the primary beam at the 10-20% level. Simulations of these effects have provided insight and concern, showing that the lunar subsurface modeled as a lossy dielectric can absorb a large amount of the power of the sky signal. While this absorption may not strongly impact the signal-to-noise ratio in a sky-noise-dominated regime, it could complicate the beam pattern and make the signal more difficult to model and interpret. We have simulated the far-field properties of the LuSEE-Night beam for varying dielectric profiles of the lunar subsurface. We find that varying the properties of the lunar subsurface has the most significant impact around the antenna resonance, impacting its amplitude, position and width. Conversely, changing the properties of the foreground impacts the data across the band. We use a Bayesian inference pipeline to jointly estimate parameters of a galactic foreground model and dielectric properties of the lunar subsurface around the LuSEE-Night landing site and find that parameters of both the galaxy and subsurface properties can be estimated jointly. While the modeling is somewhat idealized, we believe that the results are largely robust owing to the fact that spectral variations for plausible subsurface and galaxy models have very different spectral signatures.

astro-ph.IM

Release and Recapture of Silica Nanoparticles from an Optical Trap in Weightlessness

Optically trapped Silica nanoparticles are a promising tool for precise sensing of gravitational or inertial forces and fundamental physics, including tests of quantum mechanics at 'large' mass scales. This field, called levitated optomechanics can greatly benefit from an application in weightlessness. In this paper we demonstrate the feasibility of such setups in a microgravity environment for the first time. Our experiment is operated in the GraviTower Bremen that provides up to 2.5 s of free fall. System performance and first release-recapture experiments, where the particle is no longer trapped are conducted in microgravity. This demonstration should also be seen in the wider context of preparing space missions on the topic of levitated optomechanics.

physics.optics

Linear map-making with LuSEE-Night

LuSEE-Night is a pathfinder radio telescope on the lunar far side employing four 3-m monopole antennas arranged as two horizontal cross pseudo-dipoles on a rotational stage and sensitive to the radio sky in the 1-50 MHz frequency band. LuSEE-Night measures the corresponding 16 correlation products as a function of frequency. While each antenna combination measures radiation coming from a large area of the sky, their aggregate information as a function of phase in the lunar cycle and rotational stage position can be deconvolved into a low-resolution map of the sky. We study this deconvolution using linear map-making based on the Wiener filter algorithm. We illustrate how systematic effects can be effectively marginalised over as contributions to the noise covariance and demonstrate this technique on beam knowledge uncertainty and gain fluctuations. With reasonable assumptions about instrument performance, we show that LuSEE-Night should be able to map the sub-50 MHz sky at a ~5-degree resolution.

astro-ph.IM

The high-speed X-ray camera on AXIS: design and performance updates

AXIS, a Probe mission concept now in a Phase A study, will provide transformative studies of high-energy astrophysical phenomena thanks to its high-resolution X-ray spectral imaging. These capabilities are enabled by improvements to the mirror design that greatly increase the X-ray throughput per unit mass; and to the detector system, which operates more than an order of magnitude faster than heritage instruments while maintaining excellent spectral performance. We present updates to the design of the AXIS High-Speed Camera, a collaborative effort by MIT, Stanford University, the Pennsylvania State University, and the Southwest Research Institute. The camera employs large-format MIT Lincoln Laboratory CCDs that feature multiple high-speed, low-noise output amplifiers and an advanced single-layer polysilicon gate structure for fast, low-power clock transfers. A first lot of prototype CCID100 CCDs has completed fabrication and will soon begin X-ray performance testing. The CCDs are paired with high-speed, low-noise ASIC readout chips designed by Stanford to provide better performance than conventional discrete solutions at a fraction of the power consumption and footprint. Complementary Front-End Electronics employ state-of-the-art digital video waveform capture and advanced signal processing to further deliver low noise at high speed. The Back-End Electronics provide high-speed identification of candidate X-ray events and transient monitoring that relays fast alerts of changing sources to the community. We highlight updates to our parallel X-ray performance test facilities at MIT and Stanford, and review the current performance of the CCD and ASIC technology from testing of prototype devices. These measurements achieve excellent spectral response at the required readout rate, demonstrating that we will meet mission requirements and enable AXIS to achieve world-class science.

astro-ph.IM

Development and testing of integrated readout electronics for next generation SiSeRO (Single electron Sensitive Read Out) devices

The first generation of Single electron Sensitive Read Out (SiSeRO) amplifiers, employed as on-chip charge detectors for charge-coupled devices (CCDs) have demonstrated excellent noise and spectral performance: a responsivity of around 800 pA per electron, an equivalent noise charge (ENC) of 3.2 electrons root mean square (RMS), and a full width half maximum (FWHM) energy resolution of 130 eV at 5.9 keV for a readout speed of 625 Kpixel/s. Repetitive Non Destructive Readout (RNDR) has also been demonstrated with these devices, achieving an improved ENC performance of 0.36 electrons RMS after 200 RNDR cycles. In order to mature this technology further, Stanford University, in collaboration with MIT Kavli Institute and MIT Lincoln Laboratory, are developing new SiSeRO detectors with improved geometries that should enable greater responsivity and improved noise performance. These include CCD devices employing arrays of SiSeRO amplifiers to optimize high speed, low noise RNDR readout and a proof-of-concept SiSeRO active pixel sensor (APS). To read out these devices, our team has developed a compact, 8-channel, fast, low noise, low power application specific integrated circuit (ASIC) denoted the Multi-Channel Readout Chip (MCRC) that includes an experimental drain current readout mode intended for SiSeRO devices. In this paper, we present results from the first tests of SiSeRO CCD devices operating with MCRC readout, and our designs for next generation SiSeRO devices.

astro-ph.IM

Fast, low noise CCD systems for future strategic x-ray missions

Future strategic X-ray missions, such as the Advanced X-ray Imaging Satellite (AXIS) and those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and noise capabilities required by such programs, the X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing readout systems that leverage the high speed, low noise, and low power consumption of application-specific integrated circuit (ASIC) devices. Here, we report the energy resolution and noise performance achieved using MIT-LL AXIS prototype charge-coupled device (CCD) detectors in conjunction with Stanford-developed Multi-Channel Readout Chip (MCRC) ASICs. Additionally, we present a new sampling method for simultaneous optimization of the output gate (OG), reset gate (RG), and reset drain (RD) biases which, in combination with new integrated fast summing well (SW) and RG clock operation modes, enables the data rates required of future X-ray telescopes.

astro-ph.IM

Ground calibration plans for the AXIS high speed camera

The Advanced X-ray Imaging Satellite (AXIS), an astrophysics NASA probe mission currently in phase A, will provide high-throughput, high-spatial resolution X-ray imaging in the 0.3 to 10 keV band. We report on the notional ground calibration plan for the High Speed Camera on AXIS, which is being developed at the MIT Kavli Institute for Astrophysics and Space Research using state-of-the-art CCDs provided by MIT Lincoln Laboratory in combination with an integrated, high-speed ASIC readout chip from Stanford University. AXIS camera ground calibration draws on previous experience with X-ray CCD focal plans, in particular Chandra/ACIS and Suzaku/XIS, utilizing mono-energetic X-ray line sources to measure spectral resolution and quantum efficiency. Relative quantum efficiency of the CCDs will be measured against an sCMOS device, with known absolute calibration from synchrotron measurements. We walk through the envisioned CCD calibration pipeline and we discuss the observatory-level science and calibration requirements and how they inform the camera calibration.

astro-ph.IM

A Virtual Frisch-Grid Geometry-Based CZT Gamma Detector for In-Field Radioisotope Identification

We present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from single keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor's active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations towards radioisotope identification.

physics.ins-det

Background Measurements and Simulations of the ComPair Balloon Flight

ComPair, a prototype of the All-sky Medium Energy Gamma-ray Observatory (AMEGO), completed a short-duration high-altitude balloon campaign on August 27, 2023 from Fort Sumner, New Mexico, USA. The goal of the balloon flight was the demonstration of ComPair as both a Compton and Pair telescope in flight, rejection of the charged particle background, and measurement of the background $\gamma$-ray spectrum. This analysis compares measurements from the balloon flight with Monte Carlo simulations to benchmark the instrument. The comparison finds good agreement between the measurements and simulations and supports the conclusion that ComPair accomplished its goals for the balloon campaign. Additionally, two charged particle background rejection schemes are discussed: a soft ACD veto that records a higher charged particle event rate but with less risk of event loss, and a hard ACD veto that limits the charged particle event rate on board. There was little difference in the measured spectra from the soft and hard ACD veto schemes, indicating that the hard ACD veto could be used for future flights. The successes of ComPair's engineering flight will inform the development of the next generation of ComPair with upgraded detector technology and larger active area.

astro-ph.IM