arXiv ScienceSearch

arXiv subjects

Sten Hansen

Publications and source records attributed to Sten Hansen.

7 recordsLinked to original sources

Position Resolution of a Scintillator Hodoscope Employing Triangular Counters with Embedded Wavelength Shifting Fibers

Scintillator counters employing embedded wavelength-shifting fibers have been used in particle physics experiments for several decades. Such counters have been produced with square, rectangular, and triangular profiles. An advantage of arrays of triangular counters is that their position resolution can be greatly enhanced by interpolation between adjacent counters using their relative light yields. We report here on a testbeam study of the position resolution of such a scintillator hodoscope and compare the results to a simulation. We find an order of magnitude improvement in the position resolution over that found by simply using the fiber separation.

physics.ins-det

The level-1 trigger for the SuperCDMS experiment at SNOLAB

The SuperCDMS SNOLAB dark matter search experiment aims to be sensitive to energy depositions down to O(1 eV). This imposes requirements on the resolution, signal efficiency, and noise rejection of the trigger system. To accomplish this, the SuperCDMS level-1 trigger system is implemented in an FPGA on a custom PCB. A time-domain optimal filter algorithm realized as a finite impulse response filter provides a baseline resolution of 0.38 times the standard deviation of the noise, $\sigma_n$, and a 99.9% trigger efficiency for signal amplitudes of 1.1 $\sigma_n$ in typical noise conditions. Embedded in a modular architecture, flexible trigger logic enables reliable triggering and vetoing in a dead-time-free manner for a variety of purposes and run conditions. The trigger architecture and performance are detailed in this article.

physics.ins-det

Photoelectron Yields of Scintillation Counters with Embedded Wavelength-Shifting Fibers Read Out With Silicon Photomultipliers

Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\,GeV protons. The yields were measured as a function of transverse, longitudinal, and angular positions for a variety of scintillator compositions and reflective coating mixtures, fiber diameters, and photosensor sizes. Timing performance was also studied. These studies were carried out by the Cosmic Ray Veto Group of the Mu2e collaboration as part of their R\&D program.

physics.ins-det

Low-Cost Data Acquisition Card for School-Network Cosmic Ray Detectors

The Cosmic Ray Observatory Project (CROP) at University of Nebraska/Lincoln and the Washington Area Large-scale Time coincidence Array (WALTA) at University of Washington/Seattle are among several outreach projects siting cosmic-ray detectors at local high schools in cities around North America, to study the origins and interactions of high-energy cosmic rays. In a collaboration between QuarkNet, the outreach program based at Fermilab, CROP, and WALTA, a low-cost data acquisition electronics card has been developed to collect and synchronize the data from each detector site. The cost for each card is under US$500 for parts, functionally replacing much more expensive electronics crates and modules at each high school site. The card has 4 analog discriminator inputs for photo-multiplier tube signals, a 4-channel Time-to-Digital converter for local coincidence and time-over-threshold measurements at 0.75 ns resolution, programmable trigger logic via a CPLD and microcontroller, and a built-in low-cost GPS receiver/antenna module (via external cable) to provide event trigger time stamps at better than 100 ns accuracy. Temperature sensors and a barometer are also integrated to record environmental data along with the counter data. The card connects to any PC or laptop via a standard RS-232 serial port for data output and control. The microcontroller and CPLD are field programmable and therefore make the card functionality flexible and easy to upgrade.

physics.ins-det

Description of the Damn Yankee Controller (DYC)

Versions of the Damn Yankee Controller (DYC) have been used to read out digitizers on the Fermilab E791, E835, FOCUS, SELEX, and KTeV experiments. The DYC accepts 16-bit data and control signals from 10 MHz Emitter Coupled Logic (ECL) PORT digitizing modules such as LeCroy CAMAC PCOS latches and FERA Analog to Digital Converters (ADCs). Data is packed into First In First Out (FIFO) memories as 32-bit longwords. Complete events including data, a leading word count, and an Event Synchronization Number are transmitted to a data destination. The DYC described here was meant to be simple and fast and was designed and built in a period of three weeks.

hep-ex

Status of the QCDSP project

We describe the completed 8,192-node, 0.4Tflops machine at Columbia as well as the 12,288-node, 0.6Tflops machine assembled at the RIKEN Brookhaven Research Center. Present performance as well as our experience in commissioning these large machines is presented. We outline our on-going physics program and explain how the configuration of the machine is varied to support a wide range of lattice QCD problems, requiring a variety of machine sizes. Finally a brief discussion is given of future prospects for large-scale lattice QCD machines.

hep-lat

QCDSP - A status report

The QCDSP machine at Columbia University has grown to 2,048 nodes achieving a peak speed of 100 Gigaflops. Software for quenched and Hybrid Monte Carlo (HMC) evolution schemes has been developed for staggered fermions, with support for Wilson and clover fermions under development. We provide an overview of the runtime environment, the current status of the QCDSP construction program and preliminary results not presented elsewhere in these proceedings.

hep-lat