arXiv Science⌕ Search

arXiv subjects

Stefanie Speidel

Publications and source records attributed to Stefanie Speidel.

At least 19 recordsLinked to original sources

Current validation practice undermines surgical AI development

Surgical data science (SDS) is rapidly advancing, yet clinical adoption of artificial intelligence (AI) in surgery remains limited, with inadequate validation as an important contributing factor. Existing validation practices often neglect the temporal and hierarchical structure of intraoperative videos, yielding misleading or clinically irrelevant results. We introduce a comprehensive catalogue of validation pitfalls in AI-based surgical video analysis, derived from a multi-stage Delphi process with 92 international experts. Pitfalls span three categories: (1) data, (2) metric selection/configuration, and (3) aggregation and reporting. A systematic review of surgical AI papers reveals that these pitfalls are widespread. Experiments on surgical video datasets show that ignoring temporal and hierarchical data structures can understate uncertainty, obscure critical failure modes, and alter algorithm rankings. To address these shortcomings, we provide consensus-based best practices compiled. Together, this work provides an evidence-based framework for rigorous validation of surgical video analysis algorithms, guiding benchmarking, reporting, regulatory review, and clinical translation.

q-bio.OT↗

When Genomic Masking Priors Fail to Transfer: Strong Variant Prediction, Weak Functional Generation

Bidirectional discrete diffusion model appears naturally suited to genomic modeling because it can reconstruct missing sequence from both flanks. We developed GenDA (Genomic Density-optimized Absorbing Diffusion) under the additional hypothesis that entropy-guided span placement would concentrate reconstruction pressure on compositionally complex regions, improving both downstream variant-effect prediction and functional sequence generation. Our results only partially support this premise. After supervised fine-tuning, the 202M-parameter GenDA model reaches a pooled ClinVar SNV AUROC of 0.774, exceeding a similarly scaled autoregressive model by 0.103. However, a matched random-span variant reaches 0.777, providing no evidence that entropy guidance causes the ClinVar improvement. More unexpectedly, GenDA fails a zero-shot functional inpainting stress test: across promoters, enhancers, exon boundaries, and intron boundaries, it does not consistently outperform a control that shuffles the native gap while exactly preserving 3-mer composition. Failure is already present for 50--500-bp gaps, although enhancer degradation worsens at longer gaps. Diagnostics identify several boundary conditions: entropy measures local sequence complexity rather than functional importance; 1-mer tokenization limits physical context; training spans are capped at 300 bp; and high absolute AlphaGenome fidelity can coexist with negative control-normalized restoration. These results show that strong fine-tuned variant prediction, a plausible corruption prior, and functional generation are distinct claims that require separate validation.

cs.LG↗

HeiCo-FOCUS: A Clinically Grounded Dataset for Long-Context Video Understanding

Recent advances in Vision-Language Models (VLMs) have led to rapid progress in video understanding across a wide range of benchmark tasks. However, existing evaluations largely focus on short-term reasoning, failing to assess a critical capability: maintaining cumulative temporal consistency over extended time horizons. To close this evaluation gap, we introduce HeiCo-FOCUS, a clinically grounded dataset for evaluating long-context video understanding through the task of Foreign Object Contextual Understanding in Surgery. Built on a dataset of Heidelberg Colorectal surgeries, this task requires models to continuously track multiple objects as they are inserted, manipulated, occluded, and removed over procedures lasting up to hours. HeiCo-FOCUS comprises 30,000 visual question answering (VQA) pairs covering five core capabilities: object recognition, temporal grounding, aggregation, event and procedural understanding, and complex reasoning. The dataset was constructed through a rigorous multi-stage annotation pipeline involving large-scale crowd annotation and 39 surgical domain experts to ensure high quality and clinical relevance. To systematically probe model behavior, we introduce a multi-track evaluation framework that progressively increases temporal and contextual demands from single frames to full procedures. Experiments with ten frontier VLMs show that HeiCo-FOCUS tasks are far from solved: only around half of the models clearly outperform a text-only baseline. Across the video tracks, models perform best on event and procedural understanding (mean Accuracy: 56.5% across all models), while temporal grounding remains particularly challenging for all evaluated models (mean Accuracy: 19.7%). We therefore expect HeiCo-FOCUS to serve as a catalyst for the development of models capable of reliable, temporally consistent reasoning over hours-long videos.

cs.CV↗

Understanding Multimodality in Generative Behavioral Cloning

Behavioral cloning becomes challenging when the same observation admits several valid actions. We study how generative behavioral-cloning policies represent such multimodal expert behavior and identify different bottlenecks across model parameterizations. For latent-variable policies, preserving demonstrated modes requires action-conditioned information in the latent representation. Excessive posterior-prior regularization can suppress this information and prevent the policy from distinguishing demonstrated modes. Weaker or aggregate regularization can preserve mode information, but shifts the challenge to ensuring that the deployment-time prior covers the relevant latent regions. For action-space generative policies, multimodality is constrained by the smoothness of the base-to-action transport: a map with a small Lipschitz constant cannot assign substantial probability to many well-separated modes. Covering many modes therefore requires either sharp transitions in base space or off-support bridge regions in action space. Experiments on synthetic multimodal navigation and a physical-robot bimodal manipulation task support these mechanisms. In contrast, our analysis reveals limited conditional multimodality in standard robotic simulation benchmarks, where deterministic regression remains competitive.

cs.LG↗

Calibration-Free Surface Normals Estimation in Vision-Based Tactile Sensing using Universal Photometric Stereo

Vision-based tactile sensors are a popular solution for capturing rich contact surface geometry. However, to obtain high-detail contact surface normals and depth, it is necessary to calibrate the sensor by physically pressing a probe with known geometry against the sensor elastomer and mapping tactile images onto the ground truth probe's shape. This approach does not scale across different tactile sensors, and the calibration effort can be complex depending on the sensor shape and optical system. Instead, we propose a calibration-free procedure for the estimation of contact surface normals using Universal Photometric Stereo neural networks. In a series of real-world experiments, we evaluate our approach on 3 sensors with different optical systems, demonstrating that universal methods are a suitable approach for estimating surface normals at the contact patch from tactile images, thereby alleviating the need for tactile sensor calibration. Controlled experiments with a metal ball show that universal methods match the calibrated method, with a mean angular error of $6.56^{\Large\circ}$. We show that the proposed framework recovers high-frequency surface details of objects with natural textures, achieving an overall mean angular error of $10.66^{\Large\circ}$. Universal method robustly recovers the contact surface normals captured with dome-shaped Digit 360, achieving a low angular discrepancy of $10.18^{\Large\circ}$ relative to the calibrated baseline. This experiment demonstrates that with sufficient illumination settings surface normals could be estimated using a model trained solely on synthetic data. By providing a unified representation of contact surfaces across different vision-based tactile sensor designs, Universal Photometric Stereo neural networks lay the foundation for transferable tactile perception across sensors.

cs.CV↗

Federated Learning for Surgical Vision in Appendicitis Classification: Results of the FedSurg EndoVis 2024 Challenge

Developing generalizable surgical AI requires multi-institutional data, yet privacy constraints preclude direct data sharing, making Federated Learning (FL) a natural candidate. Its application to complex, spatiotemporal surgical video remains largely unbenchmarked. We present the FedSurg Challenge, the first international initiative dedicated to FL in surgical vision, as a proof-of-concept evaluation using a multi-center dataset of laparoscopic appendectomies (subset of Appendix300). Three participant submissions were evaluated on generalization to an unseen clinical center and center-specific local adaptation, alongside centralized, Swarm Learning, parameter-efficient fine-tuning baselines, and reference classifiers. Our analysis identifies temporal modeling as the architectural factor most consistently associated with generalization to the unseen center, although effects vary across metrics. Classifier collapse arises from both the global model's failure to transfer under domain shift and unconstrained fine-tuning on small, imbalanced local datasets, motivating structured personalized FL for center-specific adaptation. Absolute performance remains far from clinical viability: even with all data pooled centrally, the task reached a 26.31% F1-score on the unseen center. Paired permutation tests resolve only large differences, and no adaptation comparison reaches significance at this sample size. By characterizing these limitations, this work establishes a methodological reference point for privacy-preserving surgical video AI.

cs.CV↗

Looking Beyond the Scale: Do Surgical Skill Models Learn Transferable Representations Across Assessment Rubrics?

Vision-based surgical skill assessment has shown strong in-domain results, yet a fundamental question remains unasked: do these models learn transferable representations of surgical proficiency, or do they merely encode dataset-specific visual patterns? This paper systematically analyzes what limits cross-domain skill transfer between the GOALS and OSATS assessment scales using the LASANA and JIGSAWS datasets. Each evaluated method serves a targeted diagnostic purpose: end-to-end training to test whether supervised skill learning transfers directly, Adaptive Sharpness-Aware Minimization (ASAM) to probe whether flatter loss landscapes improve generalization, and augmentation-based self-supervised and contrastive learning to assess whether domain-invariant pretraining decouples skill from visual context. Transfer is evaluated in both directions using a disjoint-participant held-out test set for JIGSAWS. Results reveal an asymmetry: backbones pretrained on JIGSAWS achieve CCC values of 0.77 to 0.80 on LASANA, closely matching the end-to-end baseline, showing cross-rubric transfer is feasible when the target domain provides consistent supervision. Transfer to JIGSAWS fails across all methods, likely due to annotation inconsistencies. Control experiments with a Kinetics-pretrained backbone suggest task-specific heads carry the majority of the skill prediction burden, while the backbone need only provide adequate spatiotemporal features. These findings offer a new perspective on vision-based skill assessment: the central question of whether skill representations transfer across scoring systems has not been previously investigated. Results indicate the visual component is dominant but not solely responsible for skill prediction; further work is needed to conclusively disentangle transferable skill features from those bound to a specific visual domain.

cs.CV↗

MISTac: A Vision-Based Tactile Sensor for Minimally Invasive Surgery

Minimally invasive and robot-assisted surgery offer many advantages over traditional open surgery, but deprive surgeons of tactile feedback and the ability to palpate tissue with their fingers. To address this lack of tactile feedback, we introduce the MISTac, a high resolution vision-based tactile sensor specifically designed for palpation in MIS. The sensor has a replaceable sensor tip with a diameter of 8 mm which allows it to fit through the trocars used in minimally invasive surgery. Its modular 3D-printed case design allows the use of bulky off-the-shelf illumination and imaging hardware that can easily be exchanged and upgraded. The sensor has an optical resolution of 176.68 $μm$, a tactile resolution of 250 $μm$, and can resolve forces as little as 24.3 mN. An in vivo study with the sensor shows its usability in minimally invasive surgery. We trained a machine learning model with the tactile data collected in the trial on a tissue classification task achieving an aggregate accuracy of ~84% in a leave-one-out cross validation. Tactile sensors have the potential to one day aid surgeons during minimally invasive surgery with tasks such as tissue classification or intra-operative tumor localization; MISTac is a small step towards this vision. We open-source MISTac at https://github.com/lasr-lab/mistac

cs.RO↗

Point Tracking in Surgery--The 2025 Surgical Tattoos in Infrared Challenge (STIRC2025)

Point tracking in surgery is crucial to enable applications in downstream tasks such as segmentation, 3D reconstruction, virtual tissue landmarking, autonomous probe-based scanning, and subtask autonomy. This paper introduces the 2025 iteration of a point tracking challenge to address this, wherein participants submit their algorithms for quantification. Their algorithms are evaluated using a dataset named surgical tattoos in infrared (STIR), with the challenge named the STIR Challenge 2025 (STIRC2025). The STIR Challenge 2025 comprises two quantitative components: accuracy and efficiency. The accuracy component tests the accuracy of algorithms on in vivo and ex vivo sequences. The efficiency component tests algorithm inference latency. The challenge was conducted as a part of MICCAI EndoVis 2025, and seven teams participated in this challenge. In this paper we summarize the challenge results and participant methods. The challenge dataset is available at: https://zenodo.org/records/20191078, and the code for baseline models and metrics calculation is available here: https://github.com/athaddius/STIRMetrics

cs.CV↗

OSS: Open Suturing Skills Vision-Based Assessment Challenge 2024-2025

Achieving high levels of surgical skill through effective training is essential for optimal patient outcomes. Automated, data-driven skill assessment holds significant potential to improve surgical training. While machine learning-based methods are increasingly popular for assessing skills in minimally invasive surgery, their application to open surgery remains limited. We present the results of a dedicated MICCAI challenge designed to benchmark and advance vision-based skill assessment in open surgery. The challenge dataset comprises videos of an open suturing training task recorded with a static GoPro camera in a dry-lab setting, with instrument trajectories available in addition to the primary video modality. The OSS Challenge was hosted over two consecutive years, comprising two and three independent tasks, respectively: (1) classifying skill level into four classes, (2) predicting the full Objective Structured Assessment of Technical Skills across eight categories, and (3) tracking hands and surgical tools. Participants submitted diverse solutions including deep learning-based video models, tracking-driven methods, and hybrid approaches. General-purpose spatiotemporal video models consistently achieved the strongest performance, though conceptually diverse approaches reached competitive levels when well-executed. Predicting fine-grained OSATS scores remains challenging but benefits substantially from increased training data. Keypoint tracking proves difficult given frequent occlusions and out-of-frame instances, limiting current applicability for motion-based skill analysis. This work benchmarks innovative and diverse solutions for surgical skill assessment, highlighting both the promise and current limitations of video-based evaluation in open surgery and identifying critical directions for advancing automated skill assessment toward clinical impact.

cs.CV↗

Intuitive Surgical SurgToolLoc and SurgVU Challenges Results: 2022-2025

Robotic assisted (RA) surgery promises to transform surgical intervention. Intuitive Surgical is committed to fostering these changes and the machine learning models and algorithms that will enable them. With these goals in mind we have invited the surgical data science community to participate in a yearly competition hosted through the Medical Imaging Computing and Computer Assisted Interventions (MICCAI) conference. With varying changes from year to year, we have challenged the community to solve difficult machine learning problems in the context of advanced RA applications. Here we document the results of these challenges, focusing on surgical tool localization (SurgToolLoc) and surgical visual understanding (SurgVU). The publicly released dataset that accompanies these challenges is detailed in a separate paper arXiv:2501.09209 [1].

cs.CV↗

MoLF: Mixture-of-Latent-Flow for Pan-Cancer Spatial Gene Expression Prediction from Histology

Inferring spatial transcriptomics (ST) from histology enables scalable histogenomic profiling, yet current methods are largely restricted to single-tissue models. This fragmentation fails to leverage biological principles shared across cancer types and hinders application to data-scarce scenarios. While pan-cancer training offers a solution, the resulting heterogeneity challenges monolithic architectures. To bridge this gap, we introduce MoLF (Mixture-of-Latent-Flow), a generative model for pan-cancer histogenomic prediction. MoLF leverages a conditional Flow Matching objective to map noise to the gene latent manifold, parameterized by a Mixture-of-Experts (MoE) velocity field. By dynamically routing inputs to specialized sub-networks, this architecture effectively decouples the optimization of diverse tissue patterns. Our experiments demonstrate that MoLF establishes a new state-of-the-art, consistently outperforming both specialized and foundation model baselines on pan-cancer benchmarks. Furthermore, MoLF exhibits zero-shot generalization to cross-species data, suggesting it captures fundamental, conserved histo-molecular mechanisms.

cs.LG↗

Supervised Mixture-of-Experts for Surgical Grasping and Retraction

Imitation learning has achieved remarkable success in robotic manipulation, yet its application to surgical robotics remains challenging due to data scarcity, constrained workspaces, and the need for an exceptional level of safety and predictability. We present a supervised Mixture-of-Experts (MoE) architecture designed for phase-structured surgical manipulation tasks, which can be added on top of any autonomous policy. Unlike prior surgical robot learning approaches that rely on multi-camera setups or thousands of demonstrations, we show that a lightweight action decoder policy like Action Chunking Transformer (ACT) can learn complex, long-horizon manipulation from less than 150 demonstrations using solely stereo endoscopic images, when equipped with our architecture. We evaluate our approach on the collaborative surgical task of bowel grasping and retraction, where a robot assistant interprets visual cues from a human surgeon, executes targeted grasping on deformable tissue, and performs sustained retraction. Our results show that generalist Vision Language Action models fail to acquire the task entirely, even under standard in-distribution conditions. Furthermore, while standard ACT achieves moderate success in-distribution, adopting a supervised MoE architecture significantly boosts its performance, yielding higher success rates in-distribution and demonstrating superior robustness in out-of-distribution scenarios, including novel grasp locations, reduced illumination, and partial occlusions. Notably, it generalizes to unseen testing viewpoints and also transfers zero-shot to ex vivo porcine tissue without additional training, offering a promising pathway toward in vivo deployment. To support this statement, we present qualitative preliminary results of policy roll-outs during in vivo porcine surgery.

cs.RO↗

LAR-MoE: Latent-Aligned Routing for Mixture of Experts in Robotic Imitation Learning

Imitation learning enables robots to acquire manipulation skills from demonstrations, yet deploying a policy across tasks with heterogeneous dynamics remains challenging, as models tend to average over distinct behavioral modes present in the demonstrations. Mixture-of-Experts (MoE) architectures address this by activating specialized subnetworks, but requires meaningful skill decompositions for expert routing. We introduce Latent-Aligned Routing for Mixture of Experts (LAR-MoE), a two-stage framework that decouples unsupervised skill discovery from policy learning. In pre-training, we learn a joint latent representation between observations and future actions through student-teacher co-training. In a post-training stage, the expert routing is regularized to follow the structure of the learned latent space, preventing expert collapse while maintaining parameter efficiency. We evaluate LAR-MoE in simulation and on hardware. On the LIBERO benchmark, our method achieves a 95.2% average success rate with 150M parameters. On a surgical bowel grasping and retraction task, LAR-MoE matches a supervised MoE baseline without requiring any phase annotations, and transfers zero-shot to ex vivo porcine tissue. Our findings suggest that latent-aligned routing provides a principled alternative to supervised skill decomposition, enabling structured expert specialization from unlabeled demonstrations.

cs.RO↗

An Open-Source Robotics Research Platform for Autonomous Laparoscopic Surgery

Autonomous robot-assisted surgery demands reliable, high-precision platforms that strictly adhere to the safety and kinematic constraints of minimally invasive procedures. Existing research platforms, primarily based on the da Vinci Research Kit, suffer from cable-driven mechanical limitations that degrade state-space consistency and hinder the downstream training of reliable autonomous policies. We present an open-source, robot-agnostic Remote Center of Motion (RCM) controller based on a closed-form analytical velocity solver that enforces the trocar constraint deterministically without iterative optimization. The controller operates in Cartesian space, enabling any industrial manipulator to function as a surgical robot. We provide implementations for the UR5e and Franka Emika Panda manipulators, and integrate stereoscopic 3D perception. We integrate the robot control into a full-stack ROS-based surgical robotics platform supporting teleoperation, demonstration recording, and deployment of learned policies via a decoupled server-client architecture. We validate the system on a bowel grasping and retraction task across phantom, ex vivo, and in vivo porcine laparoscopic procedures. RCM deviations remain sub-millimeter across all conditions, and trajectory smoothness metrics (SPARC, LDLJ) are comparable to expert demonstrations from the JIGSAWS benchmark recorded on the da Vinci system. These results demonstrate that the platform provides the precision and robustness required for teleoperation, data collection and autonomous policy deployment in realistic surgical scenarios.

cs.RO↗

The Dresden Dataset for 4D Reconstruction of Non-Rigid Abdominal Surgical Scenes

The D4D Dataset provides paired endoscopic video and high-quality structured-light geometry for evaluating 3D reconstruction of deforming abdominal soft tissue in realistic surgical conditions. Data were acquired from six porcine cadaver sessions using a da Vinci Xi stereo endoscope and a Zivid structured-light camera, registered via optical tracking and manually curated iterative alignment methods. Three sequence types - whole deformations, incremental deformations, and moved-camera clips - probe algorithm robustness to non-rigid motion, deformation magnitude, and out-of-view updates. Each clip provides rectified stereo images, per-frame instrument masks, stereo depth, start/end structured-light point clouds, curated camera poses and camera intrinsics. In postprocessing, ICP and semi-automatic registration techniques are used to register data, and instrument masks are created. The dataset enables quantitative geometric evaluation in both visible and occluded regions, alongside photometric view-synthesis baselines. Comprising over 300,000 frames and 369 point clouds across 98 curated recordings, this resource can serve as a comprehensive benchmark for developing and evaluating non-rigid SLAM, 4D reconstruction, and depth estimation methods.

cs.CV↗

Federated EndoViT: Pretraining Vision Transformers via Federated Learning on Endoscopic Image Collections

Purpose: Data privacy regulations hinder the creation of generalizable foundation models (FMs) for surgery by preventing multi-institutional data aggregation. This study investigates federated learning (FL) as a privacy-preserving solution to collaboratively train robust surgical FMs. Methods: We introduce Federated EndoViT (FL-EndoViT), a federated framework that validates the Masked Autoencoder (MAE) pretraining strategy in a decentralized surgical setting. To ensure convergence under severe data heterogeneity, the architecture integrates adaptive Sharpness-Aware Minimization (FedSAM). Pretrained on the large-scale Endo700k dataset, FL-EndoViT is evaluated against a centralized baseline on different tasks including scene segmentation, action recognition, and phase recognition. Results: FedSAM is critical for successful pretraining, overcoming the convergence failures of standard federated methods. The resulting FL-EndoViT performs comparably to its centralized counterpart, with significant advantages in data-scarce, high-resolution segmentation and generalization to new surgical events. We also establish that full, end-to-end fine-tuning is necessary for optimal performance. Conclusion: This work validates FL with adaptive optimization as a viable paradigm for creating robust, privacy-preserving surgical FMs. Our findings provide a scalable framework for collaborative Surgical Data Science and underscore the optimizer's critical role in handling data heterogeneity. Future work should explore video-based models to incorporate spatiotemporal dynamics.

cs.CV↗

A benchmark for video-based laparoscopic skill analysis and assessment

Laparoscopic surgery is a complex surgical technique that requires extensive training. Recent advances in deep learning have shown promise in supporting this training by enabling automatic video-based assessment of surgical skills. However, the development and evaluation of deep learning models is currently hindered by the limited size of available annotated datasets. To address this gap, we introduce the Laparoscopic Skill Analysis and Assessment (LASANA) dataset, comprising 1270 stereo video recordings of four basic laparoscopic training tasks. Each recording is annotated with a structured skill rating, aggregated from three independent raters, as well as binary labels indicating the presence or absence of task-specific errors. The majority of recordings originate from a laparoscopic training course, thereby reflecting a natural variation in the skill of participants. To facilitate benchmarking of both existing and novel approaches for video-based skill assessment and error recognition, we provide predefined data splits for each task. Furthermore, we present baseline results from a deep learning model as a reference point for future comparisons.

cs.CV↗