arXiv ScienceSearch

arXiv subjects

Shuaiqi Cheng

Publications and source records attributed to Shuaiqi Cheng.

2 recordsLinked to original sources

PhysDox: Benchmarking LLMs on Physical Feasibility Auditing of Physiological Sensing Protocols

Large language models (LLMs) increasingly assist in experimental design, yet fluent protocols often remain physically infeasible. We introduce PhysDox, a physical feasibility auditing benchmark for biomedical protocols comprising a 683-sample expert-curated Gold set and a 5,000-sample Silver set across six sensing domains. We formulate the task as a two-stage evaluation: severity detection classifying protocols as valid, minor, or fatal, followed by the constraint-level diagnosis of fatal violations. Evaluating 6 LLMs across 4 inference strategies yields a peak Stage-1 macro-F1 of only 53.0. Moreover, strong oracle diagnosis collapses during end-to-end evaluation due to correlated cascade errors. Error analysis reveals scaffold bias, where models conflate procedural completeness with physical validity. Consequently, implicit constraints exhibit a 2 times higher miss rate than explicit hardware violations, supported by strong statistical correlation at $ρ{=}0.81$ and $p{<}0.01$. Trace analysis of false negatives exposes a 54%--46% split between attention and judgment failures, ultimately demonstrating that protocol auditing demands calibrated feasibility reasoning rather than factual recall or longer rationales.

cs.HC

From Elastic to Viscoelastic: An EEMD-Enhanced Pulse Transit Time Model for Robust Blood Pressure Estimation

Cuffless blood pressure (BP) estimation based on Pulse Transit Time (PTT) has emerged as a promising solution for continuous health monitoring. However, conventional models relying on the Moens-Korteweg equation often fail during rapid hemodynamic fluctuations, as they assume arterial walls are purely elastic and neglect inherent viscoelasticity. To address this limitation, we propose a physics-informed framework introducing a viscoelastic compensation mechanism. First, raw photoplethysmogram (PPG) signals undergo high-fidelity reconstruction using Modified Akima (Makima) interpolation. Second, a robust Intersecting Tangent Method is applied for precise pulse foot localization. Crucially, we utilize Ensemble Empirical Mode Decomposition (EEMD) to isolate high-frequency Intrinsic Mode Functions (IMFs), defining a ``Viscoelastic Velocity Metric'' to quantify the vascular damping effect ($η\cdot \dotε$) typically ignored by elastic models. The framework was rigorously validated on a challenging subset of the MIMIC-II database (364 subjects, 28,525 cardiac cycles) characterized by a high prevalence of hypertension (23.4\%). Experimental results demonstrate medical-grade accuracy, yielding a Root Mean Square Error (RMSE) of 5.22 mmHg for Systolic and 3.65 mmHg for Diastolic BP, with Pearson correlation coefficients ($R > 0.97$). These findings confirm that incorporating viscoelastic features significantly enhances robustness against vascular hysteresis.

cs.HC