Compound Prompt Constraints in LLM Code Generation: A Factorial Study of Format, Persona, and Urgency

Large language models (LLMs) are increasingly used in software engineering pipelines for code generation, where production prompts often combine multiple constraints. This paper presents a full-factorial empirical study of how output formatting, persona assignment, and urgency framing jointly affect LLM code-generation reliability. We evaluate all 27 combinations in a controlled 3x3x3 design and decompose each compound condition into an additive prediction and a residual interaction term that captures super-additive degradation. The study uses all 164 HumanEval+ problems across five OpenAI models from the GPT-4o family, GPT-4.1 family, and o3-mini, yielding 22,140 greedy-decoding evaluations. A format-aware extraction pipeline separates formatting failures from reasoning failures, and significance is assessed with McNemar's test, odds ratios, and 95% confidence intervals. Results show that compound constraints can produce architecture-dependent degradation not predictable from single-factor experiments. The GPT-4o family exhibits consistent super-additive effects, with pass@1 reductions 3-12 percentage points beyond additive predictions; the largest interaction is -12.2 pp on GPT-4o-mini for JSON + expert persona + moderate urgency. JSON combinations generally produce larger interactions than XML. In contrast, the GPT-4.1 family is largely resistant, while o3-mini shows a qualitatively different pattern in which structured output constraints can improve performance. These findings show that vulnerability is architecture-dependent rather than size-dependent, that individually neutral or beneficial constraints can combine to cause substantial degradation, and that compound-prompt testing should be standard in reliability assessment for LLM-assisted engineering pipelines.

cs.SE

Data Center Life Cycle Co-Design Optimization

Liquid cooled supercomputers dissipate tens of megawatts of waste heat through cooling plants organized as parallel subloops that serve coolant distribution units. The number of subloops and the assignment of units to them are design decisions fixed at construction, yet they have not been systematically optimized at this scale. We present a framework that integrates operational energy from a validated control optimizer, embodied carbon and capital cost from a bill of materials, maintenance over the service life, and expected unplanned downtime from a component level reliability model. All 611 ways of partitioning the 25 coolant distribution units of the Frontier supercomputer into two through six subloops are evaluated. When redundancy is not costed, the optimum is two subloops holding 14 and 11 units, at 3,320.7 tonnes of carbon dioxide equivalent and 3,987k dollars over a 7 year horizon, saving 35.7 tonnes and 63k dollars compared to the documented as built configuration of three duty subloops holding 14, 6 and 5 units. The difference is driven by piping rather than by operational energy, and the identity of the optimum is unchanged across 15 sensitivity scenarios and both extremes of physical unit grouping, although its margin narrows under compact grouping. When the N+1 standby train that the plant actually carries is priced, the optimum moves to four or five duty subloops, adjacent to the three the plant runs and far from the unconstrained answer, and the semi-analytical decision rule reproduces this shift across four leadership class systems. Redundancy policy, not cost or carbon, is what sets the subloop count. A conversion of the built plant is shown not to pay back, so the framework is a greenfield design tool.

eess.SY

Digital Twin-Based Cooling System Optimization for Data Center

Data center cooling systems consume significant auxiliary energy, yet optimization studies rarely quantify the gap between theoretically optimal and operationally deployable control strategies. This paper develops a digital twin of the liquid cooling infrastructure at the Frontier exascale supercomputer, in which a hot-temperature water system comprises three parallel subloops, each serving dedicated coolant distribution unit clusters through plate heat exchangers and variable-speed pumps. The surrogate model is built based on Modelica and validated through one full calendar year of 10-minute operational data following ASHRAE Guideline 14. The model achieves a subloop coefficient of variation of the root mean square error below 2.7% and a normalized mean bias error within 2.5%. Using this validated surrogate model, a layered optimization framework evaluates three progressively constrained strategies: an analytical flow-only optimization achieves 20.4% total energy saving, unconstrained joint optimization of flow rate and supply temperature demonstrates 30.1% total energy saving, and ramp-constrained optimization of flow rate and supply temperature, enforcing actuator rate limits, can reach total energy saving of 27.8%. The analysis reveals that the baseline system operates at 2.9 times the minimum thermally safe flow rate, and the co-optimizing supply temperature with flow rate nearly doubles the savings achievable by flow reduction alone.

eess.SY

Machine Learning Guided Cooling System Optimization for Data Center

Effective data center cooling is crucial for reliable operation; however, cooling systems often exhibit inefficiencies that result in excessive energy consumption. This paper presents a three-stage, physics-guided machine learning framework for identifying and reducing cooling energy waste in high-performance computing facilities. Using one year of 10-minute resolution operational data from the Frontier exascale supercomputer, we first train a monotonicity-constrained gradient boosting surrogate that predicts facility accessory power from coolant flow rates, temperatures, and server power. The surrogate achieves a mean absolute error of 0.026 MW and predicts power usage effectiveness within 0.01 of measured values for 98.7% of test samples. In the second stage, the surrogate serves as a physics-consistent baseline to quantify excess cooling energy, revealing approximately 85 MWh of annual inefficiency concentrated in specific months, hours, and operating regimes. The third stage evaluates guardrail-constrained counterfactual adjustments to supply temperature and subloop flows, demonstrating that up to 96% of identified excess can be recovered through small, safe setpoint changes while respecting thermal limits and operational constraints. The framework yields interpretable recommendations, supports counterfactual analyses such as flow reduction during low-load periods and redistribution of thermal duty across cooling loops, and provides a practical pathway toward quantifiable reductions in accessory power. The developed framework is readily compatible with model predictive control and provides a template that, with site-specific recalibration, could be adapted to other liquid-cooled data centers with different configurations and cooling requirements.

eess.SY

Co-Design Optimization for Data Center Cooling System via Digital Twin

Liquid-cooled exascale supercomputers dissipate heat through cooling plants organized as multiple parallel subloops, but how to allocate coolant distribution units (CDUs) across subloops and how to distribute flow among them has not been systematically addressed for facilities at this scale. This paper presents a three-layer optimization framework that jointly determines the integer partition of CDUs across subloops, the continuous flow fraction allocation, and the per-timestep co-design optimization of total flow rate and supply temperature subject to per-subloop thermal safety constraints. The Modelica simulation model is built based on the data of the Frontier exascale supercomputer at Oak Ridge National Laboratory. By developing a reduced-order surrogate model, all 611 feasible partitions of 25 CDUs are evaluated across the full year operational dataset of 49,353 timesteps. Three progressively richer operational strategies are compared, ranging from flow control optimization to full three-layer co-design optimization with dynamically adjusted flow fractions. The optimal design within the surrogate optimization problem is a two-subloop plant achieving 35.48% annual cooling energy savings, only 0.18% above the current three-subloop design at 35.30%. Most of the savings are delivered by supervisory co-optimization of total flow rate and supply temperature; the distinct role of flow fraction optimization is design robustness rather than additional raw savings. Flow fraction optimization compensates for any feasible CDU-to-subloop assignment, reducing the design sensitivity by 93% and providing a low-cost software-only pathway to near-optimal performance on the existing Frontier hardware. The framework is transferable to other liquid-cooled high-performance computing plants.

eess.SY

Physics-Informed Graph Neural Jump ODEs for Cascading Failure Prediction in Power Grids

Cascading failures in power grids pose severe risks to infrastructure reliability, yet real-time prediction of their progression remains an open challenge. Physics-based simulators require minutes to hours per scenario, while existing graph neural network approaches treat cascading failures as static classification tasks, ignoring temporal evolution and physical laws. This paper proposes Physics-Informed Graph Neural Jump ODEs (PI-GN-JODE), combining an edge-conditioned graph neural network encoder, a Neural ODE for continuous power redistribution, a jump process handler for discrete relay trips, and Kirchhoff-based physics regularization. The model simultaneously predicts edge and node failure probabilities, severity classification, and demand not served, while an autoregressive extension enables round-by-round temporal cascade prediction. Evaluated on the IEEE 24-bus and 118-bus systems with 20,000 scenarios each, PI-GN-JODE achieves a Precision--Recall Area Under the Curve of 0.991 for edge failure detection, 0.973 for node failure detection, and a coefficient of determination of 0.951 for demand-not-served regression on the 118-bus system, outperforming a standard graph convolutional network baseline (0.948, 0.925, and 0.912, respectively). Ablation studies reveal that the four components function synergistically, with the physics-informed loss alone contributing +9.2 points to demand-not-served regression. Performance improves when scaling to larger grids, and the architecture achieves the highest balanced accuracy (0.996) on the PowerGraph benchmark using data from a different simulation framework.

eess.SY

Scalable Fairness Shaping with LLM-Guided Multi-Agent Reinforcement Learning for Peer-to-Peer Electricity Markets

Peer-to-peer (P2P) energy trading is becoming central to modern distribution systems as rooftop PV and home energy management systems become pervasive, yet most existing market and reinforcement learning designs emphasize efficiency or private profit and offer little real-time guidance to ensure equitable outcomes under uncertainty. To address this gap, a fairness-aware multiagent reinforcement learning framework, FairMarket-RL, is proposed in which a large language model (LLM) critic shapes bidding policies within a continuous double auction under partial observability and discrete price-quantity actions. After each trading slot, the LLM returns normalized fairness scores Fairness-to-Grid (FTG), Fairness-Between-Sellers (FBS), and Fairness-of-Pricing (FPP) that are integrated into the reward via ramped coefficients and tunable scaling, so that fairness guidance complements, rather than overwhelms, economic incentives. The environment models realistic residential load and PV profiles and enforce hard constraints on prices, physical feasibility, and policy-update stability. Across a progression of experiments from a small pilot to a larger simulated community and a mixed-asset real-world dataset, the framework shifts exchanges toward local P2P trades, lowers consumer costs relative to grid-only procurement, sustains strong fairness across participants, and preserves utility viability. Sensitivity analyses over solar availability and aggregate demand further indicate robust performance, suggesting a scalable, LLM-guided pathway to decentralized electricity markets that are economically efficient, socially equitable, and technically sound.

eess.SY

Enhancing Power Flow Estimation with Topology-Aware Gated Graph Neural Networks

Accurate and scalable surrogate models for AC power flow are essential for real-time grid monitoring, contingency analysis, and decision support in increasingly dynamic and inverter-dominated power systems. However, most existing surrogates fall short of practical deployment due to their limited capacity to capture long-range nonlinear dependencies in meshed transmission networks and their weak enforcement of physical laws. These models often require extensive hyperparameter tuning, exhibit poor generalization under topology changes or large load swings, and typically do not quantify uncertainty or scale well beyond a few hundred buses. To address these challenges, this paper proposes a \textit{gated graph neural network (GGNN)} surrogate for AC power-flow estimation under topological uncertainty. The model is trained across multiple IEEE benchmark networks of varying size and complexity, each incorporating randomized line contingencies and up to 40\% load variation. To improve robustness and generalization, we explore both conventional supervised learning and physics-informed self-supervised training strategies. Comparative evaluations show that the proposed GGNN consistently outperforms prior GNN-based surrogates, achieving predictions closely aligned with Newton--Raphson solutions. By embedding operational constraints directly into the architecture and loss function, the model ensures physical consistency and delivers a lightweight, accurate, and scalable tool for real-time grid operations.

eess.SY

FairMarket-RL: LLM-Guided Fairness Shaping for Multi-Agent Reinforcement Learning in Peer-to-Peer Markets

Peer-to-peer (P2P) trading is increasingly recognized as a key mechanism for decentralized market regulation, yet existing approaches often lack robust frameworks to ensure fairness. This paper presents FairMarket-RL, a novel hybrid framework that combines Large Language Models (LLMs) with Reinforcement Learning (RL) to enable fairness-aware trading agents. In a simulated P2P microgrid with multiple sellers and buyers, the LLM acts as a real-time fairness critic, evaluating each trading episode using two metrics: Fairness-To-Buyer (FTB) and Fairness-Between-Sellers (FBS). These fairness scores are integrated into agent rewards through scheduled λ-coefficients, forming an adaptive LLM-guided reward shaping loop that replaces brittle, rule-based fairness constraints. Agents are trained using Independent Proximal Policy Optimization (IPPO) and achieve equitable outcomes, fulfilling over 90% of buyer demand, maintaining fair seller margins, and consistently reaching FTB and FBS scores above 0.80. The training process demonstrates that fairness feedback improves convergence, reduces buyer shortfalls, and narrows profit disparities between sellers. With its language-based critic, the framework scales naturally, and its extension to a large power distribution system with household prosumers illustrates its practical applicability. FairMarket-RL thus offers a scalable, equity-driven solution for autonomous trading in decentralized energy systems.

cs.LG