arXiv Science⌕ Search

arXiv subjects

Shouping Zhu

Publications and source records attributed to Shouping Zhu.

3 recordsLinked to original sources

Design and Performance Evaluation of a Quad-panel Dual-isotope PET Imaging System

In simultaneous dual-isotope PET, prompt-gamma-based separation is challenged by the low statistics of triple coincidences and the limited flexibility of coincidence logic for multi-energy event extraction. We designed and evaluated a compact quad-panel dual-isotope PET system without dedicated prompt gamma detectors. The system comprised four orthogonally arranged detector panels, each providing an effective area of 107.0 * 145.5 mm. GPU-accelerated software coincidence processing extracted double- and prompt-gamma-tagged triple coincidences from raw single-photon data. Triple-coincidence images were reconstructed with correlated-random-triple correction using the consistent delayed expectation-maximization method, followed by image-domain isotope separation using a spatially varying scaling factor. System performance was evaluated using phantom and in vivo studies, with emphasis on 68Ga/18F imaging because of the low prompt gamma yield. The system achieved energy resolutions of 15.7%, 12.9% and 10.2% at 511, 1077, and 1275 keV, and a timing resolution of 1.35 ns. In the 68Ga Derenzo, 1.6-mm rods were resolved in double-coincidence images, with 1.2-mm rods partially distinguishable, while 1.6-mm rods remained discernible in triple-coincidence images. The mean prompt gamma detection efficiencies along the three axes ranged from 8.19% to 9.31%. The system sensitivity was 1.12% for doubles with an energy window of 350-650 keV, and 0.068% for triples after random correction with a dual-energy window. The scatter fraction was 27.81%, and the NECR reached 83 kcps at 9.38 MBq for doubles and 106 cps at 21.42 MBq for triples. Phantom and in vivo studies demonstrated successful separation of 18F/68Ga and 18F/124I tracer distributions. By maintaining high-resolution and quantitative imaging performance, the system provides a preclinical platform for multitracer PET studies.

physics.med-ph↗

Joint Poisson Reconstruction for Prompt-Gamma-Enabled 68Ga/18F Dual-Isotope Quantitative PET Imaging

Objective:To enable simultaneous quantitative 68Ga/18F PET imaging despite low prompt-gamma triple-coincidence counts and random-triple contamination. Methods: We developed an expectation-maximization reconstruction method (PNR-EM) that jointly estimates pure-emitter, non-pure-emitter, and random-triple components using a Poisson model of prompt double, prompt triple, and delayed triple measurements. A consistent-delay strategy estimates random triples while preserving true-pair temporal correlations. Prompt doubles additionally constrain the non-pure component, and total variation regularization suppresses reconstruction noise. The method was evaluated with quantitative and Derenzo phantoms, a nine-well separation phantom, and tumor-bearing mice. Results: Phantom quantitation showed strong linearity (r2>0.99) and a maximum relative deviation below 9.9% relative to single-isotope references. The separated images largely preserved rod resolvability relative to their corresponding single-isotope references. The best PSNR, SSIM, and RMSE were 33.72 dB, 0.975, and 0.0206 for 18F, and 34.86 dB, 0.955, and 0.0181 for 68Ga in the 9-well phantom. The 68Ga RMSE was 41.4% lower than that of the best image-domain separation baseline. Tumor-bearing mouse imaging demonstrated in vivo separation of 68Ga-DOTA-NOC and 18F-FDG distributions. Conclusion: Joint estimation improved dual-isotope separation under the evaluated low-count conditions. Significance: To our knowledge, this study provides the first experimental demonstration of simultaneous 68Ga/18F PET separation using prompt-gamma coincidences, supporting simultaneous imaging of complementary metabolic and receptor-targeted tracer distributions.

physics.med-ph↗

Automated identification and quantification of myocardial inflammatory infiltration in digital histological images to diagnose myocarditis

This study aims to develop a new computational pathology approach that automates the identification and quantification of myocardial inflammatory infiltration in digital HE-stained images to provide a quantitative histological diagnosis of myocarditis.898 HE-stained whole slide images (WSIs) of myocardium from 154 heart transplant patients diagnosed with myocarditis or dilated cardiomyopathy (DCM) were included in this study. An automated DL-based computational pathology approach was developed to identify nuclei and detect myocardial inflammatory infiltration, enabling the quantification of the lymphocyte nuclear density (LND) on myocardial WSIs. A cutoff value based on the quantification of LND was proposed to determine if the myocardial inflammatory infiltration was present. The performance of our approach was evaluated with a five-fold cross-validation experiment, tested with an internal test set from the myocarditis group, and confirmed by an external test from a double-blind trial group. An LND of 1.02/mm2 could distinguish WSIs with myocarditis from those without. The accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) in the five-fold cross-validation experiment were 0.899 plus or minus 0.035, 0.971 plus or minus 0.017, 0.728 plus or minus 0.073 and 0.849 plus or minus 0.044, respectively. For the internal test set, the accuracy, sensitivity, specificity, and AUC were 0.887, 0.971, 0.737, and 0.854, respectively. The accuracy, sensitivity, specificity, and AUC for the external test set reached 0.853, 0.846, 0.858, and 0.852, respectively. Our new approach provides accurate and reliable quantification of the LND of myocardial WSIs, facilitating automated quantitative diagnosis of myocarditis with HE-stained images.

physics.med-ph↗