arXiv ScienceSearch

arXiv subjects

Shinji Okada

Publications and source records attributed to Shinji Okada.

9 recordsLinked to original sources

Ferromagnetic Order of Reduced Magnetic Moments in a Frustrated Sawtooth Chain of the Magnetic Semiconductor ZnYb$_2$S$_4$

In a sawtooth spin chain, competing nearest- and next-nearest-neighbor interactions suppress long-range order, yielding novel quantum states such as a spin-dimer singlet, 1/2 magnetization plateau, and spin contraction. Here, we investigate the magnetic properties of the orthorhombic semiconductor ZnYb$_2$S$_4$, in which Yb$^{3+}$ ions with an effective spin-1/2 form a sawtooth chain along the $b$-axis. The specific heat exhibits a sharp peak at ${T}_{\rm m}$ $=$ 1.4 K, at which the magnetic entropy $S_{\rm m}$ reaches only 27% of $R$ln2. This reduced $S_{\rm m}$ at $T_{\rm m}$ indicates the entropy release of the ground state doublet of Yb$^{3+}$ even for $T$ $>$ $T_{\rm m}$. The isothermal magnetization $M(B)$ at 0.28 K exhibits hysteresis for $\left|B\right| \leq 0.2$ T and increases monotonically for $B > 0.2$ T. The spontaneous magnetization is only 0.1 ${\it \mu}_{\rm B}$$/$Yb, an order of magnitude smaller than that expected for the ground state doublet of Yb$^{3+}$. Moreover, in powder neutron diffraction measurements, no superlattice reflections due to antiferromagnetic order are observed for $T$ $<$ $T_{\rm m}$. Therefore, in the ground state, the Yb moments are ferromagnetically aligned, but their amplitude is reduced by magnetic frustration in the sawtooth Yb chain.

cond-mat.str-el

Broad-band High-Energy Resolution Hard X-ray Spectroscopy using Transition Edge Sensors at SPring-8

We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron X-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and Technology (NIST) TES system, and 220 pixels are operated simultaneously with an energy resolution of $4$~eV at 6~keV at a rate of about 1~c/s/pixel. The tolerance for high count rates is evaluated in terms of energy resolution and live time fraction, leading to an empirical compromise of about 2 x 10^3 c/s/all pixels with an energy resolution of 5 eV at 6 keV. By utilizing the TES's wide-band spectroscopic capability, simultaneous multi-element analysis is demonstrated for a standard sample. We conducted X-ray absorption near-edge structure (XANES) analysis in fluorescence mode using the TES spectrometer. The excellent energy resolution of the TES enabled us to detect weak fluorescence lines from dilute samples and trace elements that have previously been difficult to resolve due to the nearly overlapping emission lines of other dominant elements. The neighboring lines of As K alpha and Pb L alpha2 of the standard sample were clearly resolved and the XANES of Pb L alpha2 was obtained. Moreover, the X-ray spectrum from the small amount of Fe in aerosols was distinguished from the spectrum of a blank target, which helps us to understand the targets and the environment. These results are the first important step for the application of high resolution TES-based spectroscopy at hard X-ray synchrotron facilities.

astro-ph.IM

The energy dependence of cluster size and its physical processes in the proton measurement with TimePix3 silicon detector

We investigated the energy dependence of the number of triggered pixels, or cluster size, when charged particles are detected using the TimePix3 detector with a silicon sensor. We measured protons in the range of 1.5~3.3 MeV from a Pelletron accelerator at RIKEN using a TimePix3 detector with a 500 um-thick silicon sensor. We determined from the experimental results a cluster size comprised between 30 and 80 pixels. To understand the physical process that produces large cluster images and its energy dependence, we simulated the charge carrier drifts in the sensor, assuming the incidence of a proton in the detector. The cluster sizes estimated in the simulation were smaller than those observed in the experiment, and remained constant across the entire energy range, when thermal diffusion and charge carriers self-repulsion were considered as the factors of the cluster image formation. In addition, we discovered that the size of the cluster image and its energy dependence observed in the experiment could be well explained when considering that the TimePix3 detector is sensitive to the transient induced charges, allowing even pixels that do not collect the charge carriers to trigger. We conclude that the cluster size measurement is a promising method for evaluating the energy deposited by a charged particle in the TimePix3 detector.

physics.ins-det

Towards Precision Spectroscopy of Antiprotonic Atoms for Probing Strong-field QED

PAX (antiProtonic Atom X-ray spectroscopy) is a new experiment with the aim to test strong-field quantum electrodynamics (QED) effects by performing high-precision x-ray spectroscopy of antiprotonic atoms. By utilizing advanced microcalorimeter detection techniques and a low-energy antiproton beam provided by the ELENA ring at CERN, gaseous targets will be used for the creation of antiprotonic atoms, and the measurement of transitions between circular Rydberg states will be conducted with up to two orders of magnitude improved accuracy over previous studies using high-purity germanium detectors. Our approach eliminates the longstanding issue of nuclear uncertainties that have hindered prior studies using highly charged ions, thus enabling direct and purely QED-focused measurements. By precisely probing atomic systems with electric fields up to two orders of magnitude above the Schwinger limit, PAX will test vacuum polarization and second-order QED corrections, opening new frontiers in fundamental physics and uncovering potential pathways to physics beyond the Standard Model.

physics.atom-ph

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($\mu$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.

physics.ins-det

Testing Quantum Electrodynamics with Exotic Atoms

Precision study of few-electron, high-$Z$ ions is a privileged field for probing high-field, bound-state quantum electrodynamics (BSQED). However, the accuracy of such tests is plagued by nuclear uncertainties, which are often larger than the BSQED effects under investigation. We propose an alternative method with exotic atoms, and show that transitions may be found between circular Rydberg states where nuclear contributions are vanishing while BSQED effects remain large. When probed with newly available quantum sensing detectors, these systems offer gains in sensitivity of \numrange{1}{2} orders of magnitude, while the mean electric field in these systems largely exceeds the Schwinger limit.

physics.atom-ph

Search for the deeply bound $K^-pp$ state from the semi-inclusive forward-neutron spectrum in the in-flight $K^-$ reaction on helium-3

An experiment to search for the $K^-pp$ bound state was performed via the in-flight $^3$He($K^-,n)$ reaction using 5.3 $\times$ $10^9$ kaons at 1 GeV/$c$ at the J-PARC hadron experimental facility. In the semi-inclusive neutron missing-mass spectrum at $\theta_{n}^{lab}=0^\circ$, no significant peak was observed in the region corresponding to $K^-pp$ binding energy larger than 80 MeV, where a bump structure has been reported in the $\Lambda p$ final state in different reactions. Assuming the state to be isotropically decaying into $\Lambda p$, mass-dependent upper limits on the production cross section were determined to be 30--180, 70--250, and 100--270 $\mu$b/sr, for the natural widths of 20, 60, and 100 MeV, respectively, at 95\% confidence level.

nucl-ex

The K1.8BR spectrometer system at J-PARC

A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from the target region, and a neutron time-of-flight counter array located $\sim$15 m downstream from the target position. Details of the design, construction, and performance of the detector components are described.

physics.ins-det