arXiv ScienceSearch

arXiv subjects

Shin

Publications and source records attributed to Shin.

3 recordsLinked to original sources

AstroPix: A Pixelated HVCMOS Sensor for Space-Based Gamma-Ray Measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25-700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 um. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 +/- 3.2% at 59.5 keV and 94 +/- 6 um depletion in a low-resistivity test silicon substrate.

astro-ph.IM

The path toward 500 $\mu$m depletion of AstroPix, a pixelated silicon HVCMOS sensor for space and EIC

The precise reconstruction of Compton-scatter events is paramount for an imaging medium-energy gamma-ray telescope. The proposed AMEGO-X is enabled by a silicon tracker utilizing AstroPix chips - a pixelated silicon HVCMOS sensor novel for space use. To achieve science goals, each 500 x 500 $\mu$m$^2$ pixel must be sensitive for energy deposits ranging from 25 - 700 keV with an energy resolution of 5 keV at 122 keV (< 10%). This is achieved through depletion of the 500 $\mu$m thick sensor, although complete depletion poses an engineering and design challenge. This work will summarize the current status of depletion measurements highlighting direct measurement with TCT laser scanning and the agreement with simulation. Future plans for further testing will also be identified.

astro-ph.IM

LGAD Detector Concept for TOPSiDE Project

We report a concept low gain avalanche diode (LGAD) detector to be integrated into TOPSiDE, which is being developed for EIC (Electron-Ion Collider) project. The LGAD detector will be taking its place to resolve requirement of time-of-flight measurement for the TOPSiDE project. To achieve the required timing resolution of 10 ps, the LGAD will be completely monolithic structure, eliminating the parasitic elements from hybridization. The detector itself will be consist of the LGAD sensor, amplification and discrimination, and time-over-threshold logic components. At this stage, we are optimizing the LGAD sensor design and preparing a discrete component based readout circuitry. In this work, we will present simulation result of a conceptual LGAD silicon detector and constant-fraction discriminator (CFD) circuit implementation. The timing resolution of the conceptual detector was simulated with EDA tools such as Silvaco Atlas and LTSpice with conjunction of a Monte-Carlo simulator to resolve Landau distribution into the circuit readout simulation. The best timing resolution we achieved was 23 ps.

physics.ins-det