arXiv Science⌕ Search

arXiv subjects

Sheon S. Y. Chua

Publications and source records attributed to Sheon S. Y. Chua.

3 recordsLinked to original sources

A Novel Arm-Length Stabilization Scheme for Gravitational-Wave Detectors with AlGaAs/GaAs Coated Mirrors

The arm length stabilisation system is employed in gravitational-wave detectors to reduce the velocity of the mirrors such that the arm cavities can be brought onto resonance in a controlled manner required to attain the detector operating point. For future upgrades of current gravitational wave detectors such as A#, which will incorporate AlGaAs/GaAs coatings, the current frequency-doubled arm length stabilisation system is unsuitable due to excessive absorption of the frequency-doubled 532nm beam by the AlGaAs/GaAs coating. We propose a novel multi-wavelength arm length stabilisation scheme that uses both frequency-doubled and frequency-tripled beams. The 1596nm auxiliary locking beam is outside the absorption bands of AlGaAs/GaAs coating. It is frequencytripled to 532nm and phase-locked with the 1064nm science laser through its second harmonic at 532 nm. In a tabletop setup, we experimentally demonstrated the stable cavity detuning and robust cavity locking transition by controlling the 1596nm laser and 1064nm laser phase locked loop. This demonstration confirmed that the proposed novel arm length stabilisation scheme is compatible with future upgrades or third-generation gravitational wave detectors that use AlGaAs/GaAs-coated test masses.

physics.optics↗

Squeezing at the normal-mode splitting frequency of a nonlinear coupled cavity

Coupled optical cavities, which support normal modes, play a critical role in optical filtering, sensing, slow-light generation, and quantum state manipulation. Recent theoretical work has proposed incorporating nonlinear materials into these systems to enable novel quantum technologies. Here, we report the first experimental demonstration of squeezing generated in a quantum-enhanced coupled-cavity system, achieving a quantum noise reduction of 3.3 dB around the normal-mode splitting frequency of 7.47 MHz. We provide a comprehensive analysis of the system's loss mechanisms and performance limitations, validating theoretical predictions. Our results underscore the promise of coupled-cavity squeezers for advanced quantum applications, including gravitational wave detection and precision sensing.

quant-ph↗

Quantum enhanced balanced heterodyne readout for differential interferometry

Conventional heterodyne readout schemes are now under reconsideration due to the realization of techniques to evade its inherent 3 dB signal-to-noise penalty. The application of high-frequency, spectrally entangled, two-mode squeezed states can further improve the readout sensitivity of audio-band signals. In this paper, we experimentally demonstrate quantum-enhanced heterodyne readout of two spatially distinct interferometers with direct optical signal combination, circumventing the 3 dB heterodyne signal-to-noise penalty. Applying a high-frequency, spectrally entangled, two-mode squeezed state, we show further signal-to-noise improvement of an injected audio band signal of 3.5 dB. This technique is applicable for quantum-limited high-precision experiments, with application to searches for quantum gravity, gravitational wave detection and wavelength-multiplexed quantum communication.

quant-ph↗