arXiv ScienceSearch

arXiv subjects

Shenda Hong

Publications and source records attributed to Shenda Hong.

At least 19 recordsLinked to original sources

Fine-tuning an ECG Foundation Model to Predict Coronary CT Angiography Outcomes

Coronary artery disease (CAD) remains a major global public health burden, yet scalable pre-imaging risk stratification tools are limited. In this multicenter study, we developed and validated an artificial intelligence-enabled electrocardiography (AI-ECG) model using coronary computed tomographic angiography (CCTA) as the anatomical reference to predict vessel-specific hemodynamically significant stenosis ($\geq 70\%$ for RCA, LAD, LCX; $\geq 50\%$ for LM). The model was evaluated in internal and external cohorts, clinically normal ECGs, and prespecified demographic and clinical subgroups. It showed discrimination across vessels in internal validation and consistent external and normal ECG performance. Predicted probabilities increased with CCTA-defined stenosis severity and were converted into vessel-specific low-, intermediate-, and high-risk strata. Calibration and decision curve analyses supported its clinical utility. Integration with guideline-based pre-test probability improved risk reclassification, enhanced rule-out performance, and reduced the gray-zone proportion. In longitudinal follow-up, model-defined risk groups showed clear separation in major adverse cardiovascular events. Waveform- and attribution-based analyses identified structured ECG differences and physiologically meaningful signal regions linked to high-risk predictions. These results support AI-ECG as a feasible tool for pre-imaging risk stratification and clinical triage, warranting prospective validation in broader clinical settings.

cs.CV

Development and Validation of a Dynamic Kidney Failure Prediction Model based on Deep Learning: A Real-World Study with External Validation

Background: Chronic kidney disease (CKD), a progressive disease with high morbidity and mortality, has become a significant global public health problem. Most existing models are static and fail to capture temporal trends in disease progression, limiting their ability to inform timely interventions. We address this gap by developing a dynamic model that leverages common longitudinal clinical indicators from real-world electronic health records (EHRs) for real-time kidney failure prediction. Findings: A retrospective cohort of 4,587 patients from the CK-NET-Yinzhou Dataset was used for model development (2,752 patients for training, 917 patients for validation) and internal validation (918 patients). External validation was performed in three cohorts: the prospective PKUFH cohort (934 patients), the C-STRIDE cohort (1,570 patients), and the iCaReMe cohort (498 patients). The model demonstrated competitive performance across the internal and three external validation cohorts, achieving AUROCs of 0.9311 (95% CI, 0.8873-0.9749), 0.8141 (0.7728-0.8554), 0.8427 (0.8213-0.8641), and 0.9359 (0.9031-0.9687), respectively. The model also demonstrated progressively improving dynamic predictions, good calibration, and clinically consistent interpretability. KFDeep has been deployed on an open-access website and in primary care settings. Interpretation: The KFDeep model enables dynamic prediction of kidney failure without increasing clinical examination costs. It has been integrated into existing hospital systems, providing physicians with a continuously updated decision-support tool in routine care.

cs.LG

Smartwatch Photoplethysmography-Derived Heart Age via ECG-Guided Cross-Modal Pretraining as a Digital Biomarker of Vascular Aging

Digital biomarkers of cardiovascular aging, often termed heart or vascular age, have been widely studied, but most rely on resting electrocardiography (ECG), imaging, or specialized vascular assessments. Evidence linking wearable photoplethysmography (PPG) to arterial stiffness and hypertension remains limited. We developed an ECG-guided cross-modal framework that uses synchronized smartwatch ECG to enhance PPG representation learning during pretraining while requiring only PPG at inference. The study included three OPPO cohorts across China, comprising 581,804 participants and 7,452,131 recordings. The Vascular Health Study cohort supported ECG-PPG self-supervised pretraining, fine-tuning, and internal validation, while two external cohorts assessed associations with pulse wave velocity (PWV) and prevalent hypertension. Combining subject-aware learning with ECG-PPG contrastive alignment, the PPG-only model achieved subject-level mean absolute errors of 5.895 years (Pearson r=0.819) in the PWV cohort and 4.344 years (r=0.800) in the home blood pressure monitoring cohort. Aggregating repeated recordings further improved short-term stability. After adjustment for chronological age, heart age gap was associated with PWV (partial r=0.2627, P<0.001); each 1-year increase corresponded to 0.062 m/s higher PWV, and accelerated versus decelerated heart aging was associated with 0.91 m/s higher adjusted PWV. Each 1-SD increase in adjusted heart age gap was associated with greater odds of prevalent hypertension (OR 1.72, 95% CI 1.49-1.99), while the highest versus lowest quartile had an OR of 4.25. These findings support smartwatch PPG-derived heart age gap as a scalable digital biomarker of arterial stiffness and prevalent hypertension.

eess.SP

Simultaneous Polysomnography and Cardiotocography Reveal Temporal Correlation Between Maternal Obstructive Sleep Apnea and Fetal Hypoxia

Background: Obstructive sleep apnea syndrome (OSAS) during pregnancy is common and can negatively affect fetal outcomes. However, studies on the immediate effects of maternal hypoxia on fetal heart rate (FHR) changes are lacking. Methods: We used time-synchronized polysomnography (PSG) and cardiotocography (CTG) data from two cohorts to analyze the correlation between maternal hypoxia and FHR changes (accelerations or decelerations). Maternal hypoxic event characteristics were analyzed using generalized linear modeling (GLM) to assess their associations with different FHR changes. Results: A total of 118 pregnant women participated. FHR changes were significantly associated with maternal hypoxia, primarily characterized by accelerations. A longer hypoxic duration correlated with more significant FHR accelerations (P < 0.05), while prolonged hypoxia and greater SpO2 drop were linked to FHR decelerations (P < 0.05). Both cohorts showed a transient increase in FHR during maternal hypoxia, which returned to baseline after the event resolved. Conclusion: Maternal hypoxia significantly affects FHR, suggesting that maternal OSAS may contribute to fetal hypoxia. These findings highlight the importance of maternal-fetal interactions and provide insights for future interventions.

eess.SP

EchoBridge: Long-Tail-Aware ECG-Echocardiography Text Alignment for Echocardiography-Derived Cardiac Findings

Standardized echocardiography conclusions provide meaningful supervision for learning ECG representations of echocardiography-derived cardiac findings. Global ECG--text alignment may entangle modality-specific factors, while long-tailed finding distributions provide sparse positive supervision for low-prevalence conditions. We propose EchoBridge with Complementary Shared--Private Projection (CSPP) and Adaptive Prototype Boundary Calibration (APBC). CSPP maps each modality into shared and auxiliary private projections, reduces directional redundancy via within-modality orthogonality, and bidirectionally aligns normalized shared projections. APBC organizes the shared hypersphere with class-specific prototypes, training-frequency-adaptive angular margins, and spherical Riesz repulsion. We evaluate EchoBridge on EchoNext-Mini and independent PKUPH and SHTMU cohorts under four protocols: prompt-based inference without downstream classifier training, in-domain frozen linear probing, target-domain cross-center frozen linear probing, and source-only cross-center transfer, supplemented by finding-specific analyses. EchoBridge improves classifier-free AUROC, AUPRC, and F1 over the strongest baselines by 7.88, 5.61, and 4.54 points, respectively, and achieves the highest point estimates across all in-domain and target-domain probing budgets and both source-only transfer cohorts. Finding-specific analyses show gains for most conditions, including several low-prevalence valvular findings.

cs.LG

Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning

Aortic valve disease (AVD) represents a major public health burden, while its diagnosis relies on echocardiography, which is limited by cost and specialist expertise, restricting scalable screening and risk stratification. Existing portable sensing modalities are constrained by indirect representations or acquisition dependencies. In this context, photoplethysmography (PPG), a widely available optical signal capturing peripheral hemodynamic dynamics, provides a scalable physiological measurement. However, the scarcity of clinically labeled PPG data severely constrains the development of effective data-driven models. To address this limitation, we propose Physiology-Guided Self-Supervised Learning (PG-SSL), leveraging approximately 170,000 unlabeled UK Biobank PPG recordings. PG-SSL constructs physiologically derived pseudo-labels based on clinically motivated waveform phenotypes associated with aortic stenosis (AS) and aortic regurgitation (AR), enabling large-scale pretraining without AVD-specific labels. Following fine-tuning on a small labeled cohort, the model achieved AUROCs of 0.8025 for AS and 0.7669 for AR. Further analyses demonstrated robustness under clinical confounding and covariate-balanced evaluation, as well as significant longitudinal associations with incident AVD events. This study demonstrates the feasibility of PG-SSL for leveraging large-scale unlabeled physiological signals under clinically labeled data-scarce conditions. The proposed approach provides a useful strategy for improving low-cost PPG-based screening and risk enrichment for clinically recognized AVD.

eess.SP

ImputeECG: Deep Learning Reconstruction of Complete 12-Lead Electrocardiograms from Incomplete Recordings for Cardiac Assessment

Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption. We developed ImputeECG, a mask-conditioned one-dimensional Transformer autoencoder that completes 12-lead, 10-s ECGs while retaining all observed samples. The model was trained on PTB-XL and evaluated on PTB-XL and CPSC2018 under simulated incomplete settings, with additional real-world validation in a 43,633-record Kailuan clinical cohort after ECG image digitization. Metrics were computed over originally missing regions, with analyses of morphology and downstream diagnostic utility. On PTB-XL, ImputeECG reduced missing-region MAE by 41.7-51.0% and MSE by 54.0-63.7% versus the strongest baseline, with lower errors in R-peak timing, RR interval, QRS duration, QT interval, and P-wave, QRS-complex, and T-wave reconstruction. On CPSC2018, ImputeECG reduced MAE by 49.7-51.9%, supporting external generalization. In downstream multi-label classification, ImputeECG restored performance to 92.28% AUROC and 33.88% AUPRC in the most incomplete PTB-XL setting, approaching complete-ECG performance. On CPSC2018, completed ECGs achieved 94.75-95.89% AUROC and 78.83-81.86% AUPRC across settings. In Kailuan, ECG completion improved zero-shot sex prediction AUROC from 82.6% to 85.8% and reduced age prediction MAE from 10.72 to 9.87 years after image-based ECG digitization. These findings support ECG completion as a practical strategy for converting incomplete ECG records into AI-ready 12-lead, 10-s digital signals and extending the usable scope of ECG archives for digital cardiac assessment.

cs.LG

ECGFlowCMR: Pretraining with ECG-Generated Cine CMR Helps Cardiac Disease Classification and Phenotype Prediction

Cardiac Magnetic Resonance (CMR) imaging provides a comprehensive assessment of cardiac structure and function but remains constrained by high acquisition costs and reliance on expert annotations, limiting the availability of large-scale labeled datasets. In contrast, electrocardiograms (ECGs) are inexpensive, widely accessible, and offer a promising modality for conditioning the generative synthesis of cine CMR. To this end, we propose ECGFlowCMR, a novel ECG-to-CMR generative framework that integrates a Phase-Aware Masked Autoencoder (PA-MAE) and an Anatomy-Motion Disentangled Flow (AMDF) to address two fundamental challenges: (1) the cross-modal temporal mismatch between multi-beat ECG recordings and single-cycle CMR sequences, and (2) the anatomical observability gap due to the limited structural information inherent in ECGs. Extensive experiments on the UK Biobank and a proprietary clinical dataset demonstrate that ECGFlowCMR can generate realistic cine CMR sequences from ECG inputs, enabling scalable pretraining and improving performance on downstream cardiac disease classification and phenotype prediction tasks.

eess.IV

MammoExpert: Benchmarking Chain-of-Thought Reasoning in Mammography Diagnosis

Mammography is an essential tool for breast cancer detection, with millions of examinations conducted annually. However, publicly available high-quality mammography datasets for AI development remain limited in both scale and annotation richness, particularly regarding pathological subtype coverage and structured diagnostic reasoning annotations. In this paper, we present MammoExpert, the first mammography dataset with Chain-of-Thought reasoning annotations across three diagnostic phases: (i) primal observation, (ii) factual assessment, and (iii) diagnostic synthesis. Comprising 2,379 mammography images covering 67 WHO-classified histopathology subtypes, each exam provides 42 radiographic features annotated by nine senior radiologists. We evaluate its performance on the breast lesion classification task, demonstrating superior accuracy and reasonability compared to existing classification models. Combining public dataset CBIS-DDSM with MammoExpert yields 7.1\% classification accuracy improvement, while the training model to learn CoT reasoning achieves another 4\% gain on the MammoExpert test set. Similar improvements are observed on INBreast and Vindr datasets, where the full approach yields accuracy gains of 6.9\% and 6.7\%, respectively. MammoExpert can serve as a benchmark for interpretable breast lesion diagnosis through explicit CoT reasoning.

cs.CV

UniECG: Understanding and Generating ECG in One Unified Model

Electrocardiogram (ECG) interpretation is a fundamental skill in medical education, yet students often need more than static examples to connect waveform evidence with diagnostic reasoning. This paper presents UniECG as a step toward interactive ECG education. UniECG supports two complementary learning interactions: given an ECG signal or image, it generates an evidence-based explanation; given a textual learning objective, it generates a corresponding ECG signal example for case-based learning. The model follows a two-stage design. First, it learns grounded ECG explanation from ECG signal--image--text data. Second, it introduces special ECG generation tokens and aligns their hidden representations with a pretrained text-conditioned ECG diffusion model, enabling controllable signal-level ECG generation. We evaluate UniECG through grounded ECG explanation and generation-oriented qualitative analysis, examining its potential to support explanation and case-based learning. UniECG is intended as an educational aid and a research step toward interactive AI-assisted ECG learning, rather than a clinically validated diagnostic system.

cs.CL

CausalMoE: A Billion-Scale Multimodal Foundation Model for Granger Causal Discovery with Pattern-Routed Heterogeneous Experts

Granger Causal Discovery (GCD) is fundamental for analyzing temporal dependencies in complex systems. However, existing neural GCD methods predominantly rely on a "one-size-fits-all" paradigm, struggling to capture distribution shifts and dynamic regime changes inherent in real-world time series. This often leads to entangled representations and spurious causal graphs. In this paper, we propose CausalMoE, a billion-scale multimodal Granger causal foundation model that explicitly models patch-level heterogeneity. CausalMoE introduces a Pattern-Routed Mixture of Heterogeneous Experts, which dynamically identifies latent temporal patterns and routes patches to specialized domain experts, effectively decoupling regime-specific mechanisms from shared dynamics. To ensure interpretable graph recovery, we design a Causality-Aware Self-Attention mechanism operating across variables, yielding sparse Granger causal graphs via proximal optimization. Furthermore, CausalMoE is the first to integrate LLMs and VLMs to align numerical signals with textual and visual priors, regularizing causal estimation in complex scenarios. Extensive experiments demonstrate that CausalMoE establishes a new state-of-the-art on fully supervised benchmarks, while effectively generalizing to few-shot settings where traditional methods fail.

cs.LG

AnyPPG: An ECG-Guided PPG Foundation Model Trained on Over 100,000 Hours of Recordings for Holistic Health Profiling

Photoplethysmography (PPG) is widely used as a non-invasive and accessible modality for continuous health monitoring. However, despite being a peripheral hemodynamic signal intrinsically coupled with systemic circulation, existing research has largely confined its scope to a narrow range of cardiovascular tasks, leaving a fundamental question underexplored: to what extent can PPG support holistic health profiling beyond traditional cardiovascular applications? To answer this question, we present AnyPPG, a foundation model-based framework designed to reveal the broader health-profiling potential of PPG. To ensure reliable performance for this investigation, AnyPPG is pretrained with ECG guidance on the most diverse PPG corpus with synchronized ECG to date, comprising over 100,000 hours of recordings from six large-scale data sources. This pretraining yields robust and physiologically grounded PPG representations that provide a reliable basis for subsequent analysis. Building upon this pretrained model, we conduct a systematic investigation into the association between PPG and holistic health through, to our knowledge, the first PPG-based phenome-wide disease detection study, spanning 1,468 disease phenotypes in more than 15,000 subjects. Our evaluation demonstrates the effectiveness of AnyPPG: across eight clinical and wearable datasets covering 15 downstream tasks, it achieves the best performance in 13 tasks. More importantly, in the phenome-wide analysis, AnyPPG exhibits meaningful discriminative capability (AUC $\ge$ 0.70) for 307 phenotypes across 16 distinct phecode chapters, including 230 non-circulatory conditions such as dementia and chronic kidney disease, many of which have rarely been explored using PPG. Collectively, these findings indicate that easily acquired PPG signals encode rich health-related information extending well beyond conventional cardiovascular assessment.

eess.SP

Wearable Single-Lead ECG Detects Fine-Grained Structural Heart Disease Through Echo-Report Supervision

Structural heart disease (SHD) is a primary driver of heart failure and cardiovascular mortality, yet early detection remains constrained by the limited accessibility of echocardiography. While single-lead electrocardiogram (ECG) is ubiquitous through wearables, existing AI screening models often depend on 12-lead inputs, generalize poorly across institutions, or require massive, condition-specific labeled datasets. Recent work has demonstrated the feasibility of contrastive pre-training between single-lead ECGs and echocardiography reports within a single health system. Here, we present AnyECG-Echo, a framework that advance this paradigm toward clinical translation through three key developments: (1) evaluation in a geographically independent external cohort (n = 16,621); (2) diagnostic coverage of 13 fine-grained SHD subtypes spanning myocardial, chamber, valvular, and great-vessel pathologies; and (3) dual-axis mechanistic interpretability combining electrophysiology-grounded Shapley attribution with emergent correlations to quantitative measurements. Across validation cohorts totaling n = 25,222, the model demonstrated high AUROC for high-impact subtypes, including reduced left ventricular systolic function (AUROC 0.866-0.924), global heart enlargement (0.877-0.931), and mitral stenosis (0.836-0.906). Furthermore, we successfully validated the alignment of model outputs with established medical physiological traits, thereby enhancing interpretability. Notably, we discovered that AnyECG-Echo's outputs function as physiologically grounded digital biomarkers that accurately track objective metrics such as LVEF and myocardial wall thickness. These findings prove that wearable single-lead ECGs can effectively detect fine-grained structural heart disease, offering a practical solution for population-scale screening.

eess.SP

ECG-R1: Protocol-Guided and Modality-Agnostic MLLM for Reliable ECG Interpretation

Electrocardiography (ECG) serves as an indispensable diagnostic tool in clinical practice, yet existing multimodal large language models (MLLMs) remain unreliable for ECG interpretation, often producing plausible but clinically incorrect analyses. To address this, we propose ECG-R1, the first reasoning ECG MLLM designed for reliable ECG interpretation via three innovations. First, we construct the interpretation corpus using \textit{Protocol-Guided Instruction Data Generation}, grounding interpretation in measurable ECG features and monograph-defined quantitative thresholds and diagnostic logic. Second, we present a modality-decoupled architecture with \textit{Interleaved Modality Dropout} to improve robustness and cross-modal consistency when either the ECG signal or ECG image is missing. Third, we present \textit{Reinforcement Learning with ECG Diagnostic Evidence Rewards} to strengthen evidence-grounded ECG interpretation. Additionally, we systematically evaluate the ECG interpretation capabilities of proprietary, open-source, and medical MLLMs, and provide the first quantitative evidence that severe hallucinations are widespread, suggesting that the public should not directly trust these outputs without independent verification. Code is available at \href{https://github.com/PKUDigitalHealth/ECG-R1}{here}.

cs.CL

MieDB-100k: A Comprehensive Dataset for Medical Image Editing

The scarcity of high-quality data remains a primary bottleneck in adapting multimodal generative models for medical image editing. Existing medical image editing datasets often suffer from limited diversity, neglect of medical image understanding and inability to balance quality with scalability. To address these gaps, we propose MieDB-100k, a large-scale, high-quality and diverse dataset for text-guided medical image editing. It categorizes editing tasks into perspectives of Perception, Modification and Transformation, considering both understanding and generation abilities. We construct MieDB-100k via a data curation pipeline leveraging both modality-specific expert models and rule-based data synthetic methods, followed by rigorous manual inspection to ensure clinical fidelity. Extensive experiments demonstrate that model trained with MieDB-100k consistently outperform both open-source and proprietary models while exhibiting strong generalization ability. We anticipate that this dataset will serve as a cornerstone for future advancements in specialized medical image editing.

cs.CV

A Scoping Review of Deep Learning Methods for Photoplethysmography Data

Background: Photoplethysmography (PPG) is a non-invasive optical sensing technique widely used to capture hemodynamic information, with broad deployment in both clinical monitoring systems and wearable devices. In recent years, the integration of deep learning has substantially advanced PPG signal analysis and expanded its applications across healthcare and non-healthcare domains. Methods: We conducted a comprehensive literature search for studies applying deep learning to PPG data published between January 1, 2017 and December 31, 2025, using Google Scholar, PubMed, and Dimensions. The included studies were analyzed from three key perspectives: tasks, models, and data. Results: A total of 460 papers applying deep learning techniques to PPG signal analysis were included. These studies span a wide range of application domains, from traditional physiological monitoring tasks such as cardiovascular assessment to emerging applications including sleep analysis, cross-modality signal reconstruction, and biometric identification. Conclusions: Deep learning has significantly advanced PPG signal analysis by enabling more effective extraction of physiological information. Compared with traditional machine learning approaches reliant on handcrafted features, deep learning methods generally achieve improved performance and offer greater flexibility in model development. Nevertheless, several challenges remain, including limited availability of large-scale high-quality datasets, insufficient validation in real-world environments, and concerns over model interpretability, scalability, and computational efficiency. Addressing these challenges and exploring emerging research directions will be essential for further progress in deep learning-based PPG analysis.

cs.AI

Masked Training for Robust Arrhythmia Detection from Digitalized Multiple Layout ECG Images

Background: Electrocardiograms are indispensable for diagnosing cardiovascular diseases, yet in many settings they exist only as paper printouts stored in multiple recording layouts. Converting these images into digital signals introduces two key challenges: temporal asynchrony among leads and partial blackout missing, where contiguous signal segments become entirely unavailable. Existing models cannot adequately handle these concurrent problems while maintaining interpretability. Methods: We propose PatchECG, combining an adaptive variable block count missing learning mechanism with a masked training strategy. The model segments each lead into fixed-length patches, discards entirely missing patches, and encodes the remainder via a pluggable patch encoder. A disordered patch attention mechanism with patch-level temporal and lead embeddings captures cross-lead and temporal dependencies without interpolation. PatchECG was trained on PTB-XL and evaluated under seven simulated layout conditions, with external validation on 400 real ECG images from Chaoyang Hospital across three clinical layouts. Results: PatchECG achieves an average AUROC of approximately 0.835 across all simulated layouts. On the Chaoyang cohort, the model attains an overall AUROC of 0.778 for atrial fibrillation detection, rising to 0.893 on the 12x1 subset -- surpassing the pre-trained baseline by 0.111 and 0.190, respectively. Model attention aligns with cardiologist annotations at a rate approaching inter-clinician agreement. Conclusions: PatchECG provides a robust, interpolation-free, and interpretable solution for arrhythmia detection from digitized ECG images across diverse layouts. Its direct modeling of asynchronous and partially missing signals, combined with clinically aligned attention, positions it as a practical tool for cardiac diagnostics from legacy ECG archives in real-world clinical environments.

cs.LG

mtslearn: Machine Learning in Python for Medical Time Series

Medical time-series data captures the dynamic progression of patient conditions, playing a vital role in modern clinical decision support systems. However, real-world clinical data is highly heterogeneous and inconsistently formatted. Furthermore, existing machine learning tools often have steep learning curves and fragmented workflows. Consequently, a significant gap remains between cutting-edge AI technologies and clinical application. To address this, we introduce mtslearn, an end-to-end integrated toolkit specifically designed for medical time-series data. First, the framework provides a unified data interface that automates the parsing and alignment of wide, long, and flat data formats. This design significantly reduces data cleaning overhead. Building on this, mtslearn provides a complete pipeline from data reading and feature engineering to model training and result visualization. Furthermore, it offers flexible interfaces for custom algorithms. Through a modular design, mtslearn simplifies complex data engineering tasks into a few lines of code. This significantly lowers the barrier to entry for clinicians with limited programming experience, empowering them to focus more on exploring medical hypotheses and accelerating the translation of advanced algorithms into real-world clinical practice. mtslearn is publicly available at https://github.com/PKUDigitalHealth/mtslearn.

cs.LG