arXiv Science⌕ Search

arXiv subjects

Shaoting Zhang

Publications and source records attributed to Shaoting Zhang.

At least 19 recordsLinked to original sources

Architecture-Aware Reinforcement Learning Makes Sliding-Window Attention Competitive in Math Reasoning

The rapid progress of reasoning and agentic large language models (LLMs) has increased the demand for long-context inference, but self-attention (SA) scales quadratically with context length. To address this, we study SWARR (Sliding-Window Attention with Reinforced Adaptation for Math Reasoning), a practical recipe for adapting SWA models to mathematical reasoning. SWARR has two stages: (1) efficient conversion from a pretrained SA model to SWA with supervised fine-tuning (SFT), which avoids pretraining a new base model, and (2) policy adaptation with reinforcement learning (RL). We find that SWA still underperforms SA after SFT, and we hypothesize that this gap is caused in part by a data-architecture mismatch: most SFT data are prepared for SA models and may contain long-range dependencies that are difficult for SWA to model. Because on-policy RL optimizes self-generated trajectories under the SWA constraint, it can adapt trajectories to better match SWA. Experiments on mathematical reasoning benchmarks show that this recipe substantially narrows the gap between SWA and SA, recovering much of the accuracy lost during SWA conversion while preserving the efficiency benefits of linear-complexity attention. Our central contribution is the empirical finding that RL changes the conclusion one would draw from conversion and SFT alone about SWA's viability for math reasoning.

cs.AI↗

REST: Reliability-Guided Spatial Transcriptomics Supervision for Gene Expression Prediction from Histopathological HE-Stained Images

Histopathology is central to cancer diagnosis, but morphology in Hematoxylin and Eosin (HE)-stained images does not directly reveal the molecular states that characterize disease heterogeneity and inform tumor characterization, prognostic assessment, and biomarker discovery. Spatial Transcriptomics (ST) measures spatially resolved gene expression, providing molecular information within tissue architecture, yet differences in assay coverage and spot informativeness make paired HE--ST observations unequally reliable for representation learning. We propose Reliability-Guided Spatial Transcriptomics (REST) supervision with Biological Program Bank (BPB), a program-structured and reliability-guided ST-supervised training framework for predicting molecular information from H\&E images. REST constructs BPB from curated signature, pathway, and cell-type gene sets to provide a shared structure for ST encoding, reliability estimation, and molecular reconstruction. Guided by BPB, Spot-Reliability Contrastive Alignment (SRCA) measures the reliability of each spot from assay-level program coverage and spot-level activity dispersion, and reweights HE--ST alignment accordingly. Biology-Informed Program Reconstruction (BIPR) further uses learnable program queries to reconstruct member-gene expression from histological morphology. REST's training corpus comprised 209 samples (407,475 spots across 16 organs); evaluation used 70 disjoint samples (230,056 spots across eight organs) for gene-expression, pathway-activity, and cell-signature prediction. REST achieved the highest Macro correlation among state-of-the-art ST-supervised training methods and outperformed existing pathology foundation models. Code is available at https://github.com/lanfz2000/REST.

cs.CV↗

EviDx: Evidence-Aware Active Diagnosis with Scaffolded LLM Agents

Clinical diagnosis is an active evidence-seeking process in which clinicians acquire evidence, update competing hypotheses, and decide when the available evidence is sufficient for diagnosis. Yet many medical diagnosis systems built around large language models (LLMs) still formulate diagnosis as static case-to-answer prediction, with limited support for evidence acquisition. Agentic LLMs offer a dynamic alternative through tool use and intermediate diagnostic trajectories, but existing systems often under-specify how patient evidence should be exposed, scaffolded, and controlled at runtime. We introduce EviDx, an evidence-aware active diagnosis framework that pairs patient-specific diagnostic environments with a clinical diagnostic scaffold and an observer-guided runtime harness. In EviDx, $\mathcal{E}$-Synthesis constructs interactive environments from raw clinical cases; the scaffold organizes role-specialized agents, evidence tools, and evolving evidence states; and the harness regulates diagnostic termination by tracking uncertainty and evidence coverage. A 3-level evaluation pyramid assesses execution robustness, reasoning dynamics, and diagnostic outcomes. Experiments show that EviDx improves diagnostic performance and process stability while revealing model-dependent capability boundaries.

cs.AI↗

DiagnosisArena: Benchmarking Diagnostic Reasoning for Large Language Models

The emergence of groundbreaking large language models capable of performing complex reasoning tasks holds significant promise for addressing various scientific challenges, including those arising in complex clinical scenarios. To enable their safe and effective deployment in real-world healthcare settings, it is urgently necessary to benchmark the diagnostic capabilities of current models systematically. Given the limitations of existing medical benchmarks in evaluating advanced diagnostic reasoning, we present DiagnosisArena, a comprehensive and challenging benchmark designed to rigorously assess professional-level diagnostic competence. DiagnosisArena consists of 1,113 pairs of segmented patient cases and corresponding diagnoses, spanning 28 medical specialties, deriving from clinical case reports published in 10 top-tier medical journals. The benchmark is developed through a meticulous construction pipeline, involving multiple rounds of screening and review by both AI systems and human experts, with thorough checks conducted to prevent data leakage. Our study reveals that even the most advanced reasoning models, o3, o1, and DeepSeek-R1, achieve only 51.12%, 31.09%, and 17.79% accuracy, respectively. This finding highlights a significant generalization bottleneck in current large language models when faced with clinical diagnostic reasoning challenges. Through DiagnosisArena, we aim to drive further advancements in AI's diagnostic reasoning capabilities, enabling more effective solutions for real-world clinical diagnostic challenges. We provide the benchmark and evaluation tools for further research and development https://github.com/SPIRAL-MED/DiagnosisArena.

cs.CL↗

MedMCP-Calc: Benchmarking LLMs for Realistic Medical Calculator Scenarios via MCP Integration

Medical calculators are fundamental to quantitative, evidence-based clinical practice. However, their real-world use is an adaptive, multi-stage process, requiring proactive EHR data acquisition, scenario-dependent calculator selection, and multi-step computation, whereas current benchmarks focus only on static single-step calculations with explicit instructions. To address these limitations, we introduce MedMCP-Calc, the first benchmark for evaluating LLMs in realistic medical calculator scenarios through Model Context Protocol (MCP) integration. MedMCP-Calc comprises 118 scenario tasks across 4 clinical domains, featuring fuzzy task descriptions mimicking natural queries, structured EHR database interaction, external reference retrieval, and process-level evaluation. Our evaluation of 23 leading models reveals critical limitations: even top performers like Claude Opus 4.5 exhibit substantial gaps, including difficulty selecting appropriate calculators for end-to-end workflows given fuzzy queries, poor performance in iterative SQL-based database interactions, and marked reluctance to leverage external tools for numerical computation. Performance also varies considerably across clinical domains. Building on these findings, we develop CalcMate, a fine-tuned model incorporating scenario planning and tool augmentation, achieving state-of-the-art performance among open-source models. Benchmark and Codes are available in https://github.com/SPIRAL-MED/MedMCP-Calc.

cs.AI↗

RareLens: Towards End-to-End Rare Disease Care via Aligning Divergent Large Language Model Reasoning

Rare diseases represent one of the most challenging settings for clinical decision-making, where heterogeneous presentations, sparse evidence and limited expertise create persistent uncertainty throughout the care pathway. Although artificial intelligence could help, existing systems largely address isolated tasks, particularly diagnosis, and usually rely on downstream investigations rather than information available at initial presentation. Here we show that clinical AI performance under uncertainty can be improved not by scaling a single model, but by exploiting the diversity of multiple imperfect reasoning systems. Across heterogeneous large language models, we identify divergent reasoning trajectories with complementary error patterns and develop RareLens, which learns to reconcile these perspectives into actionable decisions across four stages of rare disease care: risk screening, diagnosis, treatment planning and prognosis prediction. Built on RarelensBench, a real-world dataset of 157,525 cases spanning all 33 Orphanet categories and more than 7,000 conditions, RareLens outperformed every frontier model tested, including GPT-5, DeepSeek-R1, Claude-3.7-Sonnet and Gemini-2.5-Pro, across all stages. It achieved an area under the curve of 0.917 for screening and top-1 accuracies of 65.5% and 89.8% for diagnosis and treatment. In an external evaluation involving 1,287 cases and 23 physicians, autonomous RareLens and physicians assisted by RareLens both outperformed unaided physicians, while demonstrating that effective human-AI collaboration requires more than simply providing model outputs. These findings establish divergent model reasoning as an exploitable source of information and suggest a general strategy for building AI systems that operate reliably under high clinical uncertainty.

cs.AI↗

UniCycleFlow: Bidirectional Unpaired Image Translation with a Shared Rectified Flow

Bidirectional unpaired image translation must preserve source-specific structure while learning coherent transformations in both directions without paired supervision. Existing methods typically employ two direction-specific generators or train separate one-way models. Even when linked by cycle consistency, such models constrain only the round-trip endpoint reconstruction, without requiring the two directions to obey a common local transformation rule. We propose UniCycleFlow, a rectified-flow framework that represents bidirectional translation as forward and reverse integration of a single time-conditioned velocity field. This formulation organizes both directions within the same continuous dynamics, rather than coupling otherwise separate endpoint mappings. A key challenge is that unpaired data provide no meaningful source--target coupling from which rectified-flow trajectories can be constructed. UniCycleFlow addresses this challenge by learning deterministic source-conditioned endpoints whose marginal distributions are adversarially matched to the opposite domains. The resulting paths are regularized by stop-gradient self-flow matching for intermediate velocity supervision, discrete cycle closure for forward--reverse consistency, and representation path-velocity regularization for controlling localized feature changes along the trajectory. Across ten translation directions, UniCycleFlow achieves the lowest FID on 7 of 10 tasks using a single Euler evaluation and obtains the best average FID of 55.1.

cs.CV↗

Reinforcement Learning for Evidence-Seeking Diagnostic Reasoning with Large Language Models

Recent reasoning-centric Large Language Models (LLMs) have made significant strides, yet they predominantly operate on a passive-inference pattern that assumes complete information. In contrast, real-world clinical intelligence is inherently an iterative investigative process requiring strategic evidence acquisition. To bridge this gap, we formalize medical diagnosis as an Iterative Evidence-Seeking Task. We leverage Reinforcement Learning with Verifiable Rewards (RLVR) to elicit intrinsic reasoning within a closed-loop environment, guided by a novel suite of rewards that enforce diagnostic precision and examination consistency. To facilitate this, we introduce the Retrieval-Augmented Generation-based Examination Simulator (RAGES), a high-fidelity clinical oracle that provides realistic, knowledge-grounded follow-up evidence. Empirical results across diverse datasets demonstrate that our framework enables LLMs to transition from passive responders to autonomous assistants. Notably, our model demonstrates comparable performance to larger and reasoning-enhanced baselines, while RAGES proves superior to vanilla LLMs in generating biologically plausible clinical feedback.

cs.AI↗

Concept Alignment Contrast and Long-Short Prompt Memory for Test-Time Adaptation of SAM3 in Medical Image Segmentation

Concept segmentation models like Segment Anything Model 3 (SAM3) show strong generalization on natural images, yet their performance degrades in medical imaging due to the domain gap caused by different imaging principles and styles. Test-Time Adaptation (TTA) is essential for improving the testing performance by updating the model on the fly without annotations. However, existing vision-language TTA methods are mainly driven by image-level uncertainty minimization, which does not necessarily reflect region-level semantic correctness in medical segmentation. Moreover, they often lack mechanisms to maintain stability in continual one-pass adaptation, leading to limited performance when reliable dense supervision is missing for segmentation. To address these issues, we propose Concept Alignment Contrast and LongShort Prompt Memory for Test-Time Adaptation (CM-TTA) of SAM3 for medical images. First, for a test sample with multiple augmentations, we introduce a novel Concept Alignment Contrast (CAC) metric, which leverages textual-visual semantic consistency to robustly evaluate prediction quality to select the best augmented view as the supervision. Second, to balance rapid and stable adaptation, we design a Long-Short Prompt Memory (LSPM) module. The short memory dynamically fuses recent prompts based on CAC scores for agile local adaptation, while the long memory maintains a stable global prompt to generate enhanced pseudo-labels. Finally, a Densely Supervised Prompt Update (DSPU) strategy is proposed to optimize the prompt embeddings with enhanced pseudo labels as dense supervision. Extensive experiments on prostate and skin lesion segmentation demonstrate that our CM-TTA framework significantly outperforms existing methods for TTA of SAM3. The code is available at https://github.com/SherlockZYB/CM-TTA.

cs.CV↗

DeVAR: Low-Dose CT Denoising via Visual Autoregressive Modeling

Computed tomography (CT) plays a crucial role in medical diagnosis, but minimizing radiation exposure while maintaining image quality remains a critical challenge. Low-dose CT (LDCT) protocols reduce radiation risks but inevitably suffer from severe noise and artifacts that compromise diagnostic accuracy. While existing deep learning methods have achieved promising results, there remains a continuous quest for generative paradigms that intrinsically capture global-to-local structural dependencies to better preserve fine anatomical details. To this end, we propose DeVAR, a novel generative framework that applies visual autoregressive modeling (VAR) to LDCT denoising for the first time. Conditioned on global context provided by LDCT prefix tokens, DeVAR progressively generates discrete token maps of the target normal-dose CT (NDCT) via next-scale prediction. Because quantization inherently discards high-frequency information, we introduce a residual refiner to capture subtle anatomical structures beyond the capacity of a discrete codebook. Finally, empowered by a dual-representation hybrid training strategy, our hybrid NDCT decoder seamlessly integrates continuous and discrete latents to reconstruct high-fidelity, detail-preserved images. Extensive experiments on two public datasets demonstrate that DeVAR consistently achieves superior qualitative and quantitative performance compared to state-of-the-art LDCT denoising methods.

eess.IV↗

A unified multi-task framework enables interpretable chest radiograph analysis

While multimodal deep learning has advanced medical imaging analysis, existing black-box systems \textcolor{black}{may remain confined to isolated tasks, often overlooking} the trust-sensitive nature of clinical diagnosis as a multi-task process. We propose IMT-CXR (Interpretable Multi-task Transformer for Chest X-ray Analysis), a framework that emulates radiologists' diagnostic workflow through three evidence-driven stages: 1) Disease recognition; 2) Attribute characterization (e.g., size, location, severity quantification); 3) Evidence-integrated report generation with traceable decision pathways. The framework employs a unified transformer architecture optimized via medical-domain instruction tuning, sequentially executing four clinical tasks: multi-label disease classification, lesion localization, anatomical segmentation, and radiology report generation. Experimental validation demonstrates competitive performance on ten CXR benchmarks under direct inference and fine-tuning settings. In a blinded evaluation of 160 historical reports from four medical centers, three radiologists rated 66\% of AI-generated reports as comparable to or surpassing original clinical reports in diagnostic clarity, highlighting the framework's translational potential. By establishing traceable diagnostic pathways from anatomical findings to conclusions, this work bridges the gap between AI technical metrics and clinical utility, advancing trustworthy AI systems in medical imaging.

cs.CV↗

Data-Centric Foundation Models in Computational Healthcare: A Survey

The advent of foundation models (FMs) as an emerging suite of AI techniques has struck a wave of opportunities in computational healthcare. The interactive nature of these models, guided by pre-training data and human instructions, has ignited a data-centric AI paradigm that emphasizes better data characterization, quality, and scale. In healthcare AI, obtaining and processing high-quality clinical data records has been a longstanding challenge, encompassing data quantity, annotation, patient privacy, and ethics. In this survey, we investigate a wide range of data-centric approaches in the FM era (from model pre-training to inference) towards improving the healthcare workflow. We discuss key perspectives in AI security, assessment, and alignment with human values. Finally, we offer a promising outlook on FM-based analytics to enhance patient outcomes and clinical workflows in the evolving landscape of healthcare and medicine. We provide an up-to-date list of healthcare-related foundation models and datasets at https://github.com/Yunkun-Zhang/Data-Centric-FM-Healthcare.

cs.LG↗

Human-AI Co-reasoning for Clinical Diagnosis with Evidence-Integrated Language Agent

We present PULSE, a medical reasoning agent that combines a domain-tuned large language model with scientific literature retrieval to support diagnostic decision-making in complex real-world cases. To evaluate its capabilities, we curated a benchmark of 82 authentic endocrinology case reports encompassing a broad spectrum of disease types and incidence levels. In controlled experiments, we compared PULSE's performance against physicians with varying levels of expertise-from residents to senior specialists-and examined how AI assistance influenced human diagnostic reasoning. PULSE attained expert-competitive accuracy, outperforming residents and junior specialists while matching senior specialist performance at both Top@1 and Top@4 thresholds. Unlike physicians, whose accuracy declined with disease rarity, PULSE maintained stable performance across incidence tiers. The agent also exhibited adaptive reasoning, increasing output length with case difficulty in a manner analogous to the longer deliberation observed among expert clinicians. When used collaboratively, PULSE enabled physicians to correct initial errors and broaden diagnostic hypotheses, but also introduced risks of automation bias. The study explores both serial and concurrent collaboration workflows, revealing that PULSE offers robust support across common and rare presentations. These findings underscore both the promise and the limitations of language model-based agents in clinical diagnosis, and offer a framework for evaluating their role in real-world decision-making.

cs.CL↗

MADCrowner: Margin Aware Dental Crown Design with Template Deformation and Refinement

Dental crown restoration is one of the most common treatment modalities for tooth defect, where personalized dental crown design is critical. While computer-aided design (CAD) systems have notably enhanced the efficiency of dental crown design, extensive manual adjustments are still required in the clinic workflow. Recent studies have explored the application of learning-based methods for the automated generation of restorative dental crowns. Nevertheless, these approaches were challenged by inadequate spatial resolution, noisy outputs, and overextension of surface reconstruction. To address these limitations, we propose \totalframework, a margin-aware mesh generation framework comprising CrownDeformR and CrownSegger. Inspired by the clinic manual workflow of dental crown design, we designed CrownDeformR to deform an initial template to the target crown based on anatomical context, which is extracted by a multi-scale intraoral scan encoder. Additionally, we introduced \marginseg, a novel margin segmentation network, to extract the cervical margin of the target tooth. The performance of CrownDeformR improved with the cervical margin as an extra constraint. And it was also utilized as the boundary condition for the tailored postprocessing method, which removed the overextended area of the reconstructed surface. We constructed a large-scale intraoral scan dataset and performed extensive experiments. The proposed method significantly outperformed existing approaches in both geometric accuracy and clinical feasibility.

cs.CV↗

RAFM: Retrieval-Augmented Flow Matching for Unpaired CBCT-to-CT Translation

Cone-beam CT (CBCT) is routinely acquired in radiotherapy but suffers from severe artifacts and unreliable Hounsfield Unit (HU) values, limiting its direct use for dose calculation. Synthetic CT (sCT) generation from CBCT is therefore an important task, yet paired CBCT--CT data are often unavailable or unreliable due to temporal gaps, anatomical variation, and registration errors. In this work, we introduce rectified flow (RF) into unpaired CBCT-to-CT translation in medical imaging. Although RF is theoretically compatible with unpaired learning through distribution-level coupling and deterministic transport, its practical effectiveness under small medical datasets and limited batch sizes remains underexplored. Direct application with random or batch-local pseudo pairing can produce unstable supervision due to semantically mismatched endpoint samples. To address this challenge, we propose Retrieval-Augmented Flow Matching (RAFM), which adapts RF to the medical setting by constructing retrieval-guided pseudo pairs using a frozen DINOv3 encoder and a global CT memory bank. This strategy improves empirical coupling quality and stabilizes unpaired flow-based training. Experiments on SynthRAD2023 under a strict subject-level true-unpaired protocol show that RAFM outperforms existing methods across FID, MAE, SSIM, PSNR, and SegScore. The code is available at https://github.com/HiLab-git/RAFM.git.

cs.CV↗

CURE: A Multimodal Benchmark for Clinical Understanding and Retrieval Evaluation

Multimodal large language models (MLLMs) demonstrate considerable potential in clinical diagnostics, a domain that inherently requires synthesizing complex visual and textual data alongside consulting authoritative medical literature. However, existing benchmarks primarily evaluate MLLMs in end-to-end answering scenarios. This limits the ability to disentangle a model's foundational multimodal reasoning from its proficiency in evidence retrieval and application. We introduce the Clinical Understanding and Retrieval Evaluation (CURE) benchmark. Comprising $500$ multimodal clinical cases mapped to physician-cited reference literature, CURE evaluates reasoning and retrieval under controlled evidence settings to disentangle their respective contributions. We evaluate state-of-the-art MLLMs across distinct evidence-gathering paradigms in both closed-ended and open-ended diagnosis tasks. Evaluations reveal a stark dichotomy: while advanced models demonstrate clinical reasoning proficiency when supplied with physician reference evidence (achieving up to $73.4\%$ accuracy on differential diagnosis), their performance substantially declines (as low as $25.4\%$) when reliant on independent retrieval mechanisms. This disparity highlights the dual challenges of effectively integrating multimodal clinical evidence and retrieving precise supporting literature. CURE is publicly available at https://github.com/yanniangu/CURE.

cs.CL↗

Radiologist Copilot: An Agentic Framework Orchestrating Specialized Tools for Reliable Radiology Reporting

In clinical practice, radiology reporting is an essential yet complex, time-intensive, and error-prone task, particularly for 3D medical images. Existing automated approaches based on medical vision-language models primarily focus on isolated report generation. However, real-world radiology reporting extends far beyond report writing, which requires meticulous image observation and interpretation, appropriate template selection, and rigorous quality control to ensure adherence to clinical standards. This multi-stage, planning-intensive workflow fundamentally exceeds the capabilities of single-pass models. To bridge this gap, we propose Radiologist Copilot, an agentic system that autonomously orchestrates specialized tools to complete the entire radiology reporting workflow rather than isolated report writing. Radiologist Copilot enables region image localization and region analysis planning to support detailed visual reasoning, adopts strategic template selection for standardized report writing, and incorporates dedicated report quality control via quality assessment and feedback-driven iterative refinement. By integrating localization, interpretation, template selection, report composition, and quality control, Radiologist Copilot delivers a comprehensive and clinically aligned radiology reporting workflow. Experimental results demonstrate that it significantly outperforms state-of-the-art methods, supporting radiologists throughout the entire radiology reporting process. The code will be released upon acceptance.

cs.AI↗

CT-Flow: Orchestrating CT Interpretation Workflow with Model Context Protocol Servers

Recent advances in Large Vision-Language Models (LVLMs) have shown strong potential for multi-modal radiological reasoning, particularly in tasks like diagnostic visual question answering (VQA) and radiology report generation. However, most existing approaches for 3D CT analysis largely rely on static, single-pass inference. In practice, clinical interpretation is a dynamic, tool-mediated workflow where radiologists iteratively review slices and use measurement, radiomics, and segmentation tools to refine findings. To bridge this gap, we propose CT-Flow, an agentic framework designed for interoperable volumetric interpretation. By leveraging the Model Context Protocol (MCP), CT-Flow shifts from closed-box inference to an open, tool-aware paradigm. We curate CT-FlowBench, the first large-scale instruction-tuning benchmark tailored for 3D CT tool-use and multi-step reasoning. Built upon this, CT-Flow functions as a clinical orchestrator capable of decomposing complex natural language queries into automated tool-use sequences. Experimental evaluations on CT-FlowBench and standard 3D VQA datasets demonstrate that CT-Flow achieves state-of-the-art performance, surpassing baseline models by 41% in diagnostic accuracy and achieving a 95% success rate in autonomous tool invocation. This work provides a scalable foundation for integrating autonomous, agentic intelligence into real-world clinical radiology.

cs.CV↗