arXiv ScienceSearch

arXiv subjects

Shansong Wang

Publications and source records attributed to Shansong Wang.

At least 19 recordsLinked to original sources

A radiographic world model for clinical reasoning and evidence generation

Medical imaging artificial intelligence (AI) is commonly developed as separate mappings from radiographs to diagnostic outputs or from clinical descriptions to generated images, although both arise from the same underlying radiographic state. A world-model formulation instead seeks to learn an internal representation of this state that can support both clinical readout and conditional simulation of radiographic observations. Here we introduce MedDream, a radiographic world model that learns a shared continuous latent state from paired chest radiograph-text observations for diagnostic reasoning and report-conditioned evidence generation. MedDream was pretrained on 2.65 million leakage-controlled chest radiograph-text pairs curated from 4.40 million candidates. Across eight clinical datasets and two independent reader cohorts, MedDream outperformed leading diagnostic and generative comparators. For diagnostic reasoning, MedDream showed strong generalization across disease recognition, label-scarce adaptation, severity assessment, and localization, while MedDream-supported review increased mean resident concordance with independent radiologist consensus from 56.3% to 63.0%. For evidence generation, MedDream produced radiographs that preserved clinically relevant pathology and improved downstream performance on held-out real data, with synthetic augmentation increasing external VinDr-CXR macro-AUROC from 76.4% to 81.4%. More importantly, conditioning generation on prespecified subgroup performance gaps enabled targeted evidence construction, increasing weighted F1 by 3.1 percentage points in Asian patients, whereas matched-volume unguided augmentation decreased it by 2.3 points. These findings establish radiographic world models as a path toward medical AI that learns clinically meaningful internal states for interpreting, simulating, and constructing evidence for clinical use.

cs.AI

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

cs.CV

MRI super-resolution in ten sampling steps using a diffusion bridge model

Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions.

cs.CV

One-for-All Adaptive Radiotherapy Planning Agent: A Foundation Framework for Daily CBCT-guided Radiotherapy

In this work, we introduce the One-for-All Adaptive Radiotherapy Planning Agent, a unified foundation-model-based system that performs complete, treatment-specific online adaptive planning directly from daily cone-beam CT in under two minutes. The agent first autonomously predicts all essential planning components, including synthetic CT generation, multimodal alignment, and tumor/organ segmentation. It then intelligently leverages these outputs to execute the final clinical plan design, providing a comprehensive, automated solution for daily treatment. We also demonstrate that the agent enables clinicians to define planning with intent and intervene at critical decision points, ensuring a "human-in-the-loop" framework that generates acceptable plans before final approval. Evaluated on multiple datasets spanning head-and-neck, lung, abdominal, and prostate cancers with both photon and proton therapy, the proposed framework achieves clinically acceptable accuracy and plan quality comparable to clinically generated treatment plans, with target dose errors (D98) generally within 2.0 Gy of the reference plan. The strong performance of the One-for-All agent highlights the promise of a unified foundation-model approach and opens opportunities for fast, scalable, and fully automated online adaptive radiotherapy across diverse clinical scenarios.

physics.med-ph

Universal CT Representations from Anatomy to Disease Phenotype through Agglomerative Pretraining

Computed tomography (CT) is a central to three-dimensional medical imaging, yet CT-based artificial intelligence remains fragmented across task-specific models for segmentation, classification, registration, and report analysis. Here we present FlexiCT, a family of CT foundation models trained by agglomerative continual pretraining on 266,227 CT volumes from 56 publicly available datasets, forming a large-scale public resource for CT representation learning. FlexiCT uses agglomerative pretraining across three stages: two-dimensional axial pretraining, three-dimensional anatomical pretraining and report-guided semantic alignment. This training strategy supports slice-level, volume-level and vision-language analysis. Across five downstream task families (segmentation, classification, registration, vision-language understanding and clinical retrieval), FlexiCT matches or exceeds prior task-specific approaches on multiple benchmarks. Its embeddings further organize CT scans along gradients associated with various tumor stages, suggesting that CT foundation models can capture imaging features relevant to disease phenotype characterization. Project page and code are available at: https://ricklisz.github.io/flexict.github.io and https://github.com/ricklisz/FlexiCT.

cs.CV

BrainDINO: A Brain MRI Foundation Model for Generalizable Clinical Representation Learning

Brain MRI underpins a wide range of neuroscientific and clinical applications, yet most learning-based methods remain task-specific and require substantial labeled data. Here we show that a single self-supervised representation can generalize across heterogeneous brain MRI endpoints. We trained BrainDINO, a self-distilled foundation model, on approximately 6.6 million unlabeled axial slices from 20 datasets encompassing broad variation in population, disease, and acquisition setting. Using a frozen encoder with lightweight task heads, BrainDINO supported transfer across tumor segmentation, neurodegenerative and neurodevelopmental conditions classification, brain age estimation, post-stroke temporal prediction, molecular status prediction, MRI sequence classification, and survival modeling. Across tasks and supervision regimes, BrainDINO consistently equaled or exceeded natural-image and MRI-specific self-supervised baselines, with particularly strong advantages under label scarcity. Representation analyses further showed anatomically organized and pathology-sensitive feature structure in the absence of task-specific supervision. Our findings indicate that large-scale slice-wise self-supervised learning can yield a unified brain MRI representation that supports diverse neuroimaging tasks without volumetric pretraining or full-network fine-tuning, establishing a scalable foundation for robust and data-efficient brain imaging analysis. Code is available at https://github.com/mclwu22/BrainDINO

cs.LG

MedLVR: Latent Visual Reasoning for Reliable Medical Visual Question Answering

Medical vision--language models (VLMs) have shown strong potential for medical visual question answering (VQA), yet their reasoning remains largely text-centric: images are encoded once as static context, and subsequent inference is dominated by language. This paradigm is fundamentally limited in clinical scenarios, where accurate answers often depend on subtle, localized visual evidence that cannot be reliably preserved in static embeddings. We propose \textsc{MedLVR}, a latent visual reasoning framework that introduces an explicit visual evidence state into autoregressive decoding. Instead of relying solely on text-based intermediate reasoning, \textsc{MedLVR} interleaves a short latent reasoning segment within the decoder by reusing hidden states as continuous latent steps, enabling iterative preservation and refinement of query-relevant visual evidence before answer generation. To support effective visual supervision, we adopt a two-stage training strategy: region of interest (ROI)-supervised fine-tuning aligns latent states with clinically relevant image evidence, and Visual-Latent Policy Optimization (VLPO) further optimizes latent reasoning and answer generation under outcome-level rewards. Experiments on OmniMedVQA and five external medical VQA benchmarks show that \textsc{MedLVR} consistently outperforms recent reasoning baselines and improves the average score over the Qwen2.5-VL-7B backbone from 48.3\% to 53.4\%. These results show that latent visual reasoning provides an effective mechanism for preserving diagnostically relevant visual evidence and improving the reliability of medical VQA.

cs.CV

Evaluating GPT-5 as a Multimodal Clinical Reasoner: A Landscape Commentary

The transition from task-specific artificial intelligence toward general-purpose foundation models raises fundamental questions about their capacity to support the integrated reasoning required in clinical medicine, where diagnosis demands synthesis of ambiguous patient narratives, laboratory data, and multimodal imaging. This landscape commentary provides the first controlled, cross-sectional evaluation of the GPT-5 family (GPT-5, GPT-5 Mini, GPT-5 Nano) against its predecessor GPT-4o across a diverse spectrum of clinically grounded tasks, including medical education examinations, text-based reasoning benchmarks, and visual question-answering in neuroradiology, digital pathology, and mammography using a standardized zero-shot chain-of-thought protocol. GPT-5 demonstrated substantial gains in expert-level textual reasoning, with absolute improvements exceeding 25 percentage-points on MedXpertQA. When tasked with multimodal synthesis, GPT-5 effectively leveraged this enhanced reasoning capacity to ground uncertain clinical narratives in concrete imaging evidence, achieving state-of-the-art or competitive performance across most VQA benchmarks and outperforming GPT-4o by margins of 10-40% in mammography tasks requiring fine-grained lesion characterization. However, performance remained moderate in neuroradiology (44% macro-average accuracy) and lagged behind domain-specific models in mammography, where specialized systems exceed 80% accuracy compared to GPT-5's 52-64%. These findings indicate that while GPT-5 represents a meaningful advance toward integrated multimodal clinical reasoning, mirroring the clinician's cognitive process of biasing uncertain information with objective findings, generalist models are not yet substitutes for purpose-built systems in highly specialized, perception-critical tasks.

cs.CV

Efficient Vision Mamba for MRI Super-Resolution via Hybrid Selective Scanning

Background: High-resolution MRI is critical for diagnosis, but long acquisition times limit clinical use. Super-resolution (SR) can enhance resolution post-scan, yet existing deep learning methods face fidelity-efficiency trade-offs. Purpose: To develop a computationally efficient and accurate deep learning framework for MRI SR that preserves anatomical detail for clinical integration. Materials and Methods: We propose a novel SR framework combining multi-head selective state-space models (MHSSM) with a lightweight channel MLP. The model uses 2D patch extraction with hybrid scanning to capture long-range dependencies. Each MambaFormer block integrates MHSSM, depthwise convolutions, and gated channel mixing. Evaluation used 7T brain T1 MP2RAGE maps (n=142) and 1.5T prostate T2w MRI (n=334). Comparisons included Bicubic interpolation, GANs (CycleGAN, Pix2pix, SPSR), transformers (SwinIR), Mamba (MambaIR), and diffusion models (I2SB, Res-SRDiff). Results: Our model achieved superior performance with exceptional efficiency. For 7T brain data: SSIM=0.951+-0.021, PSNR=26.90+-1.41 dB, LPIPS=0.076+-0.022, GMSD=0.083+-0.017, significantly outperforming all baselines (p<0.001). For prostate data: SSIM=0.770+-0.049, PSNR=27.15+-2.19 dB, LPIPS=0.190+-0.095, GMSD=0.087+-0.013. The framework used only 0.9M parameters and 57 GFLOPs, reducing parameters by 99.8% and computation by 97.5% versus Res-SRDiff, while outperforming SwinIR and MambaIR in accuracy and efficiency. Conclusion: The proposed framework provides an efficient, accurate MRI SR solution, delivering enhanced anatomical detail across datasets. Its low computational demand and state-of-the-art performance show strong potential for clinical translation.

cs.CV

Low-Dose CT Imaging Using a Regularization-Enhanced Efficient Diffusion Probabilistic Model

Low-dose computed tomography (LDCT) reduces patient radiation exposure but introduces substantial noise that degrades image quality and hinders diagnostic accuracy. Existing denoising approaches often require many diffusion steps, limiting real-time applicability. We propose a Regularization-Enhanced Efficient Diffusion Probabilistic Model (RE-EDPM), a rapid and high-fidelity LDCT denoising framework that integrates a residual shifting mechanism to align low-dose and full-dose distributions and performs only four reverse diffusion steps using a Swin-based U-Net backbone. A composite loss combining pixel reconstruction, perceptual similarity (LPIPS), and total variation (TV) regularization effectively suppresses spatially varying noise while preserving anatomical structures. RE-EDPM was evaluated on a public LDCT benchmark across dose levels and anatomical sites. On 10 percent dose chest and 25 percent dose abdominal scans, it achieved SSIM = 0.879 (0.068), PSNR = 31.60 (2.52) dB, VIFp = 0.366 (0.121) for chest, and SSIM = 0.971 (0.000), PSNR = 36.69 (2.54) dB, VIFp = 0.510 (0.007) for abdomen. Visual and statistical analyses, including ablation and Wilcoxon signed-rank tests (p < 0.05), confirm significant contributions from residual shifting and regularization terms. RE-EDPM processes two 512x512 slices in about 0.25 s on modern GPUs, supporting near real-time clinical use. The proposed framework achieves an optimal balance between noise suppression and anatomical fidelity, offering an efficient solution for LDCT restoration and broader medical image enhancement tasks.

physics.med-ph

Foundation Models in Medical Image Analysis: A Systematic Review and Meta-Analysis

Recent advancements in artificial intelligence (AI), particularly foundation models (FMs), have revolutionized medical image analysis, demonstrating strong zero- and few-shot performance across diverse medical imaging tasks, from segmentation to report generation. Unlike traditional task-specific AI models, FMs leverage large corpora of labeled and unlabeled multimodal datasets to learn generalized representations that can be adapted to various downstream clinical applications with minimal fine-tuning. However, despite the rapid proliferation of FM research in medical imaging, the field remains fragmented, lacking a unified synthesis that systematically maps the evolution of architectures, training paradigms, and clinical applications across modalities. To address this gap, this review article provides a comprehensive and structured analysis of FMs in medical image analysis. We systematically categorize studies into vision-only and vision-language FMs based on their architectural foundations, training strategies, and downstream clinical tasks. Additionally, a quantitative meta-analysis of the studies was conducted to characterize temporal trends in dataset utilization and application domains. We also critically discuss persistent challenges, including domain adaptation, efficient fine-tuning, computational constraints, and interpretability along with emerging solutions such as federated learning, knowledge distillation, and advanced prompting. Finally, we identify key future research directions aimed at enhancing the robustness, explainability, and clinical integration of FMs, thereby accelerating their translation into real-world medical practice.

cs.CV

DINOv3 with Test-Time Training for Medical Image Registration

Prior medical image registration approaches, particularly learning-based methods, often require large amounts of training data, which constrains clinical adoption. To overcome this limitation, we propose a training-free pipeline that relies on a frozen DINOv3 encoder and test-time optimization of the deformation field in feature space. Across two representative benchmarks, the method is accurate and yields regular deformations. On Abdomen MR-CT, it attained the best mean Dice score (DSC) of 0.790 together with the lowest 95th percentile Hausdorff Distance (HD95) of 4.9+-5.0 and the lowest standard deviation of Log-Jacobian (SDLogJ) of 0.08+-0.02. On ACDC cardiac MRI, it improves mean DSC to 0.769 and reduces SDLogJ to 0.11 and HD95 to 4.8, a marked gain over the initial alignment. The results indicate that operating in a compact foundation feature space at test time offers a practical and general solution for clinical registration without additional training.

cs.CV

Is ChatGPT-5 Ready for Mammogram VQA?

Mammogram visual question answering (VQA) integrates image interpretation with clinical reasoning and has potential to support breast cancer screening. We systematically evaluated the GPT-5 family and GPT-4o model on four public mammography datasets (EMBED, InBreast, CMMD, CBIS-DDSM) for BI-RADS assessment, abnormality detection, and malignancy classification tasks. GPT-5 consistently was the best performing model but lagged behind both human experts and domain-specific fine-tuned models. On EMBED, GPT-5 achieved the highest scores among GPT variants in density (56.8%), distortion (52.5%), mass (64.5%), calcification (63.5%), and malignancy (52.8%) classification. On InBreast, it attained 36.9% BI-RADS accuracy, 45.9% abnormality detection, and 35.0% malignancy classification. On CMMD, GPT-5 reached 32.3% abnormality detection and 55.0% malignancy accuracy. On CBIS-DDSM, it achieved 69.3% BI-RADS accuracy, 66.0% abnormality detection, and 58.2% malignancy accuracy. Compared with human expert estimations, GPT-5 exhibited lower sensitivity (63.5%) and specificity (52.3%). While GPT-5 exhibits promising capabilities for screening tasks, its performance remains insufficient for high-stakes clinical imaging applications without targeted domain adaptation and optimization. However, the tremendous improvements in performance from GPT-4o to GPT-5 show a promising trend in the potential for general large language models (LLMs) to assist with mammography VQA tasks.

cs.CV

Benchmarking GPT-5 for Zero-Shot Multimodal Medical Reasoning in Radiology and Radiation Oncology

Radiology, radiation oncology, and medical physics require decision-making that integrates medical images, textual reports, and quantitative data under high-stakes conditions. With the introduction of GPT-5, it is critical to assess whether recent advances in large multimodal models translate into measurable gains in these safety-critical domains. We present a targeted zero-shot evaluation of GPT-5 and its smaller variants (GPT-5-mini, GPT-5-nano) against GPT-4o across three representative tasks. We present a targeted zero-shot evaluation of GPT-5 and its smaller variants (GPT-5-mini, GPT-5-nano) against GPT-4o across three representative tasks: (1) VQA-RAD, a benchmark for visual question answering in radiology; (2) SLAKE, a semantically annotated, multilingual VQA dataset testing cross-modal grounding; and (3) a curated Medical Physics Board Examination-style dataset of 150 multiple-choice questions spanning treatment planning, dosimetry, imaging, and quality assurance. Across all datasets, GPT-5 achieved the highest accuracy, with substantial gains over GPT-4o up to +20.00% in challenging anatomical regions such as the chest-mediastinal, +13.60% in lung-focused questions, and +11.44% in brain-tissue interpretation. On the board-style physics questions, GPT-5 attained 90.7% accuracy (136/150), exceeding the estimated human passing threshold, while GPT-4o trailed at 78.0%. These results demonstrate that GPT-5 delivers consistent and often pronounced performance improvements over GPT-4o in both image-grounded reasoning and domain-specific numerical problem-solving, highlighting its potential to augment expert workflows in medical imaging and therapeutic physics.

eess.IV

Performance of GPT-5 in Brain Tumor MRI Reasoning

Accurate differentiation of brain tumor types on magnetic resonance imaging (MRI) is critical for guiding treatment planning in neuro-oncology. Recent advances in large language models (LLMs) have enabled visual question answering (VQA) approaches that integrate image interpretation with natural language reasoning. In this study, we evaluated GPT-4o, GPT-5-nano, GPT-5-mini, and GPT-5 on a curated brain tumor VQA benchmark derived from 3 Brain Tumor Segmentation (BraTS) datasets - glioblastoma (GLI), meningioma (MEN), and brain metastases (MET). Each case included multi-sequence MRI triplanar mosaics and structured clinical features transformed into standardized VQA items. Models were assessed in a zero-shot chain-of-thought setting for accuracy on both visual and reasoning tasks. Results showed that GPT-5-mini achieved the highest macro-average accuracy (44.19%), followed by GPT-5 (43.71%), GPT-4o (41.49%), and GPT-5-nano (35.85%). Performance varied by tumor subtype, with no single model dominating across all cohorts. These findings suggest that GPT-5 family models can achieve moderate accuracy in structured neuro-oncological VQA tasks, but not at a level acceptable for clinical use.

cs.CV

Capabilities of GPT-5 on Multimodal Medical Reasoning

Recent advances in large language models (LLMs) have enabled general-purpose systems to perform increasingly complex domain-specific reasoning without extensive fine-tuning. In the medical domain, decision-making often requires integrating heterogeneous information sources, including patient narratives, structured data, and medical images. This study positions GPT-5 as a generalist multimodal reasoner for medical decision support and systematically evaluates its zero-shot chain-of-thought reasoning performance on both text-based question answering and visual question answering tasks under a unified protocol. We benchmark GPT-5, GPT-5-mini, GPT-5-nano, and GPT-4o-2024-11-20 against standardized splits of MedQA, MedXpertQA (text and multimodal), MMLU medical subsets, USMLE self-assessment exams, and VQA-RAD. Results show that GPT-5 consistently outperforms all baselines, achieving state-of-the-art accuracy across all QA benchmarks and delivering substantial gains in multimodal reasoning. On MedXpertQA MM, GPT-5 improves reasoning and understanding scores by +29.26% and +26.18% over GPT-4o, respectively, and surpasses pre-licensed human experts by +24.23% in reasoning and +29.40% in understanding. In contrast, GPT-4o remains below human expert performance in most dimensions. A representative case study demonstrates GPT-5's ability to integrate visual and textual cues into a coherent diagnostic reasoning chain, recommending appropriate high-stakes interventions. Our results show that, on these controlled multimodal reasoning benchmarks, GPT-5 moves from human-comparable to above human-expert performance. This improvement may substantially inform the design of future clinical decision-support systems.

cs.CL

Unifying Biomedical Vision-Language Expertise: Towards a Generalist Foundation Model via Multi-CLIP Knowledge Distillation

CLIP models pretrained on natural images with billion-scale image-text pairs have demonstrated impressive capabilities in zero-shot classification, cross-modal retrieval, and open-ended visual answering. However, transferring this success to biomedicine is hindered by the scarcity of large-scale biomedical image-text corpora, the heterogeneity of image modalities, and fragmented data standards across institutions. These limitations hinder the development of a unified and generalizable biomedical foundation model trained from scratch. To overcome this, we introduce MMKD-CLIP, a generalist biomedical foundation model developed via Multiple Medical CLIP Knowledge Distillation. Rather than relying on billion-scale raw data, MMKD-CLIP distills knowledge from nine state-of-the-art domain-specific or generalist biomedical CLIP models, each pretrained on millions of biomedical image-text pairs. Our two-stage training pipeline first performs CLIP-style pretraining on over 2.9 million biomedical image-text pairs from 26 image modalities, followed by feature-level distillation using over 19.2 million feature pairs extracted from teacher models. We evaluate MMKD-CLIP on 58 diverse biomedical datasets, encompassing over 10.8 million biomedical images across nine image modalities. The evaluation spans six core task types: zero-shot classification, linear probing, cross-modal retrieval, visual question answering, survival prediction, and cancer diagnosis. MMKD-CLIP consistently outperforms all teacher models while demonstrating remarkable robustness and generalization across image domains and task settings. These results underscore that multi-teacher knowledge distillation is a scalable and effective paradigm for building high-performing biomedical foundation models under the practical constraints of real-world data availability.

cs.CV

Res-MoCoDiff: Residual-guided diffusion models for motion artifact correction in brain MRI

Objective. Motion artifacts in brain MRI, mainly from rigid head motion, degrade image quality and hinder downstream applications. Conventional methods to mitigate these artifacts, including repeated acquisitions or motion tracking, impose workflow burdens. This study introduces Res-MoCoDiff, an efficient denoising diffusion probabilistic model specifically designed for MRI motion artifact correction.Approach.Res-MoCoDiff exploits a novel residual error shifting mechanism during the forward diffusion process to incorporate information from motion-corrupted images. This mechanism allows the model to simulate the evolution of noise with a probability distribution closely matching that of the corrupted data, enabling a reverse diffusion process that requires only four steps. The model employs a U-net backbone, with attention layers replaced by Swin Transformer blocks, to enhance robustness across resolutions. Furthermore, the training process integrates a combined l1+l2 loss function, which promotes image sharpness and reduces pixel-level errors. Res-MoCoDiff was evaluated on both an in-silico dataset generated using a realistic motion simulation framework and an in-vivo MR-ART dataset. Comparative analyses were conducted against established methods, including CycleGAN, Pix2pix, and a diffusion model with a vision transformer backbone, using quantitative metrics such as PSNR, SSIM, and NMSE.Main results. The proposed method demonstrated superior performance in removing motion artifacts across minor, moderate, and heavy distortion levels. Res-MoCoDiff consistently achieved the highest SSIM and the lowest NMSE values, with a PSNR of up to 41.91+-2.94 dB for minor distortions. Notably, the average sampling time was reduced to 0.37 seconds per batch of two image slices, compared with 101.74 seconds for conventional approaches.

cs.CV