arXiv Science⌕ Search

arXiv subjects

Shansong Wang

Publications and source records attributed to Shansong Wang.

At least 19 recordsLinked to original sources

Prior-Guided Physics-Informed Deep Learning for Fast 4D MRI Reconstruction

Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is an unrolled network that reconstructs 16 respiratory phases from 60, 30, or 15 s of data, and single 3D volumes, each from 0.29-0.49 s of data, using a setup-scan image. The networks were trained once, on other volunteers, and were not retrained for new volunteers. We evaluated PGPI4MR on measured k-space from three datasets: free-breathing MR-linac (1.5T) and abdominal (3T) scans, and thigh scans with cuff compression (1.5T). All methods, including comparative models, received identical samples and were scored similarly. Results: In vivo, PGPI4MR had the lowest held-out error for 4D MRI at every scan time, and its 16 phases were ready a median of 7.5-13 s after the scan on the 2 GPUs tested. Coupling the 16 respiratory phases reduced the error at 60 s by 9.1% compared with reconstructing each phase alone. For sub-second MRI, the error at 0.49 s was 15.5% lower than that of the best comparison method, classical reconstruction toward the same prior, and on the faster GPU, every 0.29 s window was acquired and reconstructed within 0.5 s. Without retraining, PGPI4MR matched the best methods on the 3T abdominal scans but not on the thigh scans; after retraining on thigh data, it reduced the held-out error by 6.6% relative to the best comparison method. Conclusion: Prior information allowed PGPI4MR to reconstruct 4D and sub-second MRI more accurately than compressed sensing and a published 4D network, within seconds and without extra scan time. This could support 4D MRI for treatment planning and 3D motion monitoring during MR-guided radiotherapy.

cs.CV↗

Image-Domain CT Metal Artifact Reduction Using an Endpoint-Conditioned Diffusion Bridge

Background: Metal implants cause streaking and shading artifacts in computed tomography (CT), obscuring anatomy and distorting Hounsfield-unit (HU) values. Conventional diffusion models reconstruct images from Gaussian noise rather than directly exploiting anatomical information retained in artifact-corrupted CT. Purpose: To develop an image-domain metal artifact reduction (MAR) method connecting artifact-corrupted and metal-free CT images through an endpoint-conditioned diffusion bridge. Methods: The proposed RDBM-MAR method uses an endpoint-conditioned diffusion bridge and initializes reconstruction from the artifact CT image. A conditional U-Net predicts an image-domain correction from intermediate bridge states. Inference uses 10 deterministic reverse steps. We used 14,000 paired CT slices from the AAPM CT-MAR Grand Challenge, including 12,045 training, 633 validation, and 1,322 held-out test slices. One clinical benchmark case was assessed qualitatively. We compared RDBM-MAR with CycleGAN, Pix2Pix, Res-SRDiff, I2I-Mamba, and I2SB using PSNR, SSIM, MAE, and LPIPS. Statistical analysis used Friedman and paired Wilcoxon signed-rank tests with Holm correction. Results: RDBM-MAR achieved the highest PSNR (43.67 +/- 4.56 dB) and SSIM (0.9856 +/- 0.0138) and the lowest MAE (14.74 +/- 8.68 HU). All four metrics differed significantly among methods (p < 0.001). RDBM-MAR outperformed all five comparators in PSNR, SSIM, and MAE (adjusted p < 0.001); Res-SRDiff achieved the lowest LPIPS. Difference maps, HU profiles, and the clinical case showed reduced artifacts with preservation of surrounding anatomy. Conclusions: RDBM-MAR provides a direct restoration trajectory from artifact CT toward metal-free CT, achieving strong structural fidelity and HU accuracy using 10 reverse steps.

physics.med-ph↗

Foundation Models in Medical Image Analysis: A Systematic Review and Meta-Analysis

Recent advancements in foundation models (FMs) have catalyzed a paradigm shift in medical image analysis. Unlike traditional task-specific artificial intelligence (AI) models, FMs leverage large-scale datasets to learn generalized representations that can be adapted to downstream clinical applications. Despite the rapid proliferation of FM research in medical imaging, there is a lack of unified synthesis that systematically maps the evolution of architectures, training paradigms, and clinical applications across modalities. To address this gap, this review provides a comprehensive and structured synthesis of FMs in medical image analysis by systematically organizing studies into two primary categories: vision-only foundation models (VFMs) and vision-language foundation models (VLFMs), based on their architectural foundations, training strategies, and downstream clinical tasks. A quantitative analysis was conducted on both VFMs and VLFMs to characterize temporal trends in dataset utilization and application domains, along with pooled performance and subgroup analyses. We also critically discuss persistent challenges, including cross-domain generalization, computational scalability, FM evaluation, fairness, and deployment. Finally, we identify key future research directions aimed at enhancing the robustness, interpretability, and clinical integration of FMs, thereby accelerating their translation into real-world medical practice.

cs.CV↗

FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

Objective. Deformable image registration remains challenging because corresponding anatomy may exhibit different intensity relationships. Hand-crafted modality-robust descriptors such as Modality-Independent Neighborhood Descriptor with Self-Similarity Context (MIND-SSC) and features from pretrained vision encoders provide distinct representations for correspondence estimation, but how they should be combined remains unclear. We investigate whether tighter integration improves registration over a sequential, scale-separated design. Approach. We introduce FlexiMIND, a training-free and label-free two-stage framework in which frozen FlexiCT-2D encoder features establish contextual correspondence and MIND-SSC refines the deformation within ConvexAdam. Five alternative feature-coupling strategies were evaluated under a protocol across CT-CT (DIR-Lab 4DCT 4DCT, 10 cases), MR-MR (ACDC, 50 patients), and MR-CT (Learn2Reg Abdomen MR-CT, 8 pairs) registration. Performance was assessed using target registration error (TRE), Dice similarity coefficient (Dice), SDlogJ, and local folding. Main results. FlexiMIND achieved a TRE of 1.27 mm on DIR-Lab 4DCT, a DSC of 0.807 on ACDC, and an organ-averaged DSC of 0.825 on Abdomen MR-CT. Across 15 coupling-strategy dataset comparisons, only four outperformed the reference method, with a maximum absolute improvement of 0.0043 in Dice, whereas degradation reached 20.6 % in TRE and 37.9 % in Dice. Changes in registration accuracy were closely associated with changes in deformation-field regularity, and strategies that better preserved regularity generally remained closest to the reference performance. Landmark-level analysis showed that the pretrained encoder stage primarily reduced large correspondence errors rather than uniformly improving local precision. Code is available upon acceptance at https://github.com/mosaf/FlexiMIND.

cs.CV↗

A radiographic world model for clinical reasoning and evidence generation

Medical imaging artificial intelligence (AI) is commonly developed as separate mappings from radiographs to diagnostic outputs or from clinical descriptions to generated images, although both arise from the same underlying radiographic state. A world-model formulation instead seeks to learn an internal representation of this state that can support both clinical readout and conditional simulation of radiographic observations. Here we introduce MedDream, a radiographic world model that learns a shared continuous latent state from paired chest radiograph-text observations for diagnostic reasoning and report-conditioned evidence generation. MedDream was pretrained on 2.65 million leakage-controlled chest radiograph-text pairs curated from 4.40 million candidates. Across eight clinical datasets and two independent reader cohorts, MedDream outperformed leading diagnostic and generative comparators. For diagnostic reasoning, MedDream showed strong generalization across disease recognition, label-scarce adaptation, severity assessment, and localization, while MedDream-supported review increased mean resident concordance with independent radiologist consensus from 56.3% to 63.0%. For evidence generation, MedDream produced radiographs that preserved clinically relevant pathology and improved downstream performance on held-out real data, with synthetic augmentation increasing external VinDr-CXR macro-AUROC from 76.4% to 81.4%. More importantly, conditioning generation on prespecified subgroup performance gaps enabled targeted evidence construction, increasing weighted F1 by 3.1 percentage points in Asian patients, whereas matched-volume unguided augmentation decreased it by 2.3 points. These findings establish radiographic world models as a path toward medical AI that learns clinically meaningful internal states for interpreting, simulating, and constructing evidence for clinical use.

cs.AI↗

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

cs.CV↗

MRI super-resolution in ten sampling steps using a diffusion bridge model

Objective. MRI provides excellent soft-tissue contrast, but long acquisition times can cause patient discomfort and lead to motion artifacts, forcing a trade-off between spatial resolution and scan time. Diffusion-based super-resolution (SR) reconstructs high-resolution (HR) images from low-resolution (LR) inputs, but typically needs many sampling steps and initializes from a Gaussian prior ill-suited to image restoration. We developed an efficient diffusion framework that reconstructs HR MRI directly from LR data. Approach. We propose super-resolution diffusion bridge model (SR-DBM), a super-resolution diffusion bridge model that casts SR as a stochastic transport between the LR and HR image distributions. Through a Doob's h-transform of a mean-reverting stochastic differential equation, SR-DBM pins the process to the paired HR and LR images at its endpoints, initializing reconstruction from the measured anatomy rather than from Gaussian noise. The HR image is recovered by a deterministic reverse trajectory in which a network predicts the clean image at each of only ten sampling steps. We evaluated SR-DBM on ultra-high-field 7T brain T1 MP2RAGE maps and pelvic T2-weighted prostate images against nine comparison methods using PSNR, SSIM, GMSD, and LPIPS. Main results. SR-DBM attained the highest PSNR and SSIM and the lowest GMSD on both datasets (brain: 27.66+-1.52 dB, 0.96+-0.02, 7.96+-1.86$; prostate: 27.87+-2.29 dB, 0.80+-0.05, 8.38+- 1.44), with statistically significant gains over every comparison method (two-sided Wilcoxon signed-rank test with Holm correction, p<0.05). The strongest baseline, SR-EMamba, ranked second. Qualitatively, SR-DBM produced the smallest residual errors and best preserved fine structures and lesions.

cs.CV↗

MedLVR: Latent Visual Reasoning for Reliable Medical Visual Question Answering

Medical vision--language models (VLMs) have shown strong potential for medical visual question answering (VQA), yet their reasoning remains largely text-centric: images are encoded once as static context, and subsequent inference is dominated by language. This paradigm is fundamentally limited in clinical scenarios, where accurate answers often depend on subtle, localized visual evidence that cannot be reliably preserved in static embeddings. We propose \textsc{MedLVR}, a latent visual reasoning framework that introduces an explicit visual evidence state into autoregressive decoding. Instead of relying solely on text-based intermediate reasoning, \textsc{MedLVR} interleaves a short latent reasoning segment within the decoder by reusing hidden states as continuous latent steps, enabling iterative preservation and refinement of query-relevant visual evidence before answer generation. To support effective visual supervision, we adopt a two-stage training strategy: region of interest (ROI)-supervised fine-tuning aligns latent states with clinically relevant image evidence, and Visual-Latent Policy Optimization (VLPO) further optimizes latent reasoning and answer generation under outcome-level rewards. Experiments on OmniMedVQA and five external medical VQA benchmarks show that \textsc{MedLVR} consistently outperforms recent reasoning baselines and improves the average score over the Qwen2.5-VL-7B backbone from 48.3\% to 53.4\%. These results show that latent visual reasoning provides an effective mechanism for preserving diagnostically relevant visual evidence and improving the reliability of medical VQA.

cs.CV↗

One-for-All Adaptive Radiotherapy Planning Agent: A Foundation Framework for Daily CBCT-guided Radiotherapy

In this work, we introduce the One-for-All Adaptive Radiotherapy Planning Agent, a unified foundation-model-based system that performs complete, treatment-specific online adaptive planning directly from daily cone-beam CT in under two minutes. The agent first autonomously predicts all essential planning components, including synthetic CT generation, multimodal alignment, and tumor/organ segmentation. It then intelligently leverages these outputs to execute the final clinical plan design, providing a comprehensive, automated solution for daily treatment. We also demonstrate that the agent enables clinicians to define planning with intent and intervene at critical decision points, ensuring a "human-in-the-loop" framework that generates acceptable plans before final approval. Evaluated on multiple datasets spanning head-and-neck, lung, abdominal, and prostate cancers with both photon and proton therapy, the proposed framework achieves clinically acceptable accuracy and plan quality comparable to clinically generated treatment plans, with target dose errors (D98) generally within 2.0 Gy of the reference plan. The strong performance of the One-for-All agent highlights the promise of a unified foundation-model approach and opens opportunities for fast, scalable, and fully automated online adaptive radiotherapy across diverse clinical scenarios.

physics.med-ph↗

BrainDINO: A Brain MRI Foundation Model for Generalizable Clinical Representation Learning

Brain MRI underpins a wide range of neuroscientific and clinical applications, yet most learning-based methods remain task-specific and require substantial labeled data. Here we show that a single self-supervised representation can generalize across heterogeneous brain MRI endpoints. We trained BrainDINO, a self-distilled foundation model, on approximately 6.6 million unlabeled axial slices from 20 datasets encompassing broad variation in population, disease, and acquisition setting. Using a frozen encoder with lightweight task heads, BrainDINO supported transfer across tumor segmentation, neurodegenerative and neurodevelopmental conditions classification, brain age estimation, post-stroke temporal prediction, molecular status prediction, MRI sequence classification, and survival modeling. Across tasks and supervision regimes, BrainDINO consistently equaled or exceeded natural-image and MRI-specific self-supervised baselines, with particularly strong advantages under label scarcity. Representation analyses further showed anatomically organized and pathology-sensitive feature structure in the absence of task-specific supervision. Our findings indicate that large-scale slice-wise self-supervised learning can yield a unified brain MRI representation that supports diverse neuroimaging tasks without volumetric pretraining or full-network fine-tuning, establishing a scalable foundation for robust and data-efficient brain imaging analysis. Code is available at https://github.com/mclwu22/BrainDINO

cs.LG↗

Universal CT Representations from Anatomy to Disease Phenotype through Agglomerative Pretraining

Computed tomography (CT) is a central to three-dimensional medical imaging, yet CT-based artificial intelligence remains fragmented across task-specific models for segmentation, classification, registration, and report analysis. Here we present FlexiCT, a family of CT foundation models trained by agglomerative continual pretraining on 266,227 CT volumes from 56 publicly available datasets, forming a large-scale public resource for CT representation learning. FlexiCT uses agglomerative pretraining across three stages: two-dimensional axial pretraining, three-dimensional anatomical pretraining and report-guided semantic alignment. This training strategy supports slice-level, volume-level and vision-language analysis. Across five downstream task families (segmentation, classification, registration, vision-language understanding and clinical retrieval), FlexiCT matches or exceeds prior task-specific approaches on multiple benchmarks. Its embeddings further organize CT scans along gradients associated with various tumor stages, suggesting that CT foundation models can capture imaging features relevant to disease phenotype characterization. Project page and code are available at: https://ricklisz.github.io/flexict.github.io and https://github.com/ricklisz/FlexiCT.

cs.CV↗

Efficient Vision Mamba for MRI Super-Resolution via Hybrid Selective Scanning

Background: High-resolution MRI is critical for diagnosis, but long acquisition times limit clinical use. Super-resolution (SR) can enhance resolution post-scan, yet existing deep learning methods face fidelity-efficiency trade-offs. Purpose: To develop a computationally efficient and accurate deep learning framework for MRI SR that preserves anatomical detail for clinical integration. Materials and Methods: We propose a novel SR framework combining multi-head selective state-space models (MHSSM) with a lightweight channel MLP. The model uses 2D patch extraction with hybrid scanning to capture long-range dependencies. Each MambaFormer block integrates MHSSM, depthwise convolutions, and gated channel mixing. Evaluation used 7T brain T1 MP2RAGE maps (n=142) and 1.5T prostate T2w MRI (n=334). Comparisons included Bicubic interpolation, GANs (CycleGAN, Pix2pix, SPSR), transformers (SwinIR), Mamba (MambaIR), and diffusion models (I2SB, Res-SRDiff). Results: Our model achieved superior performance with exceptional efficiency. For 7T brain data: SSIM=0.951+-0.021, PSNR=26.90+-1.41 dB, LPIPS=0.076+-0.022, GMSD=0.083+-0.017, significantly outperforming all baselines (p<0.001). For prostate data: SSIM=0.770+-0.049, PSNR=27.15+-2.19 dB, LPIPS=0.190+-0.095, GMSD=0.087+-0.013. The framework used only 0.9M parameters and 57 GFLOPs, reducing parameters by 99.8% and computation by 97.5% versus Res-SRDiff, while outperforming SwinIR and MambaIR in accuracy and efficiency. Conclusion: The proposed framework provides an efficient, accurate MRI SR solution, delivering enhanced anatomical detail across datasets. Its low computational demand and state-of-the-art performance show strong potential for clinical translation.

cs.CV↗

Evaluating GPT-5 as a Multimodal Clinical Reasoner: A Landscape Commentary

The transition from task-specific artificial intelligence toward general-purpose foundation models raises fundamental questions about their capacity to support the integrated reasoning required in clinical medicine, where diagnosis demands synthesis of ambiguous patient narratives, laboratory data, and multimodal imaging. This landscape commentary provides the first controlled, cross-sectional evaluation of the GPT-5 family (GPT-5, GPT-5 Mini, GPT-5 Nano) against its predecessor GPT-4o across a diverse spectrum of clinically grounded tasks, including medical education examinations, text-based reasoning benchmarks, and visual question-answering in neuroradiology, digital pathology, and mammography using a standardized zero-shot chain-of-thought protocol. GPT-5 demonstrated substantial gains in expert-level textual reasoning, with absolute improvements exceeding 25 percentage-points on MedXpertQA. When tasked with multimodal synthesis, GPT-5 effectively leveraged this enhanced reasoning capacity to ground uncertain clinical narratives in concrete imaging evidence, achieving state-of-the-art or competitive performance across most VQA benchmarks and outperforming GPT-4o by margins of 10-40% in mammography tasks requiring fine-grained lesion characterization. However, performance remained moderate in neuroradiology (44% macro-average accuracy) and lagged behind domain-specific models in mammography, where specialized systems exceed 80% accuracy compared to GPT-5's 52-64%. These findings indicate that while GPT-5 represents a meaningful advance toward integrated multimodal clinical reasoning, mirroring the clinician's cognitive process of biasing uncertain information with objective findings, generalist models are not yet substitutes for purpose-built systems in highly specialized, perception-critical tasks.

cs.CV↗

Low-Dose CT Imaging Using a Regularization-Enhanced Efficient Diffusion Probabilistic Model

Low-dose computed tomography (LDCT) reduces patient radiation exposure but introduces substantial noise that degrades image quality and hinders diagnostic accuracy. Existing denoising approaches often require many diffusion steps, limiting real-time applicability. We propose a Regularization-Enhanced Efficient Diffusion Probabilistic Model (RE-EDPM), a rapid and high-fidelity LDCT denoising framework that integrates a residual shifting mechanism to align low-dose and full-dose distributions and performs only four reverse diffusion steps using a Swin-based U-Net backbone. A composite loss combining pixel reconstruction, perceptual similarity (LPIPS), and total variation (TV) regularization effectively suppresses spatially varying noise while preserving anatomical structures. RE-EDPM was evaluated on a public LDCT benchmark across dose levels and anatomical sites. On 10 percent dose chest and 25 percent dose abdominal scans, it achieved SSIM = 0.879 (0.068), PSNR = 31.60 (2.52) dB, VIFp = 0.366 (0.121) for chest, and SSIM = 0.971 (0.000), PSNR = 36.69 (2.54) dB, VIFp = 0.510 (0.007) for abdomen. Visual and statistical analyses, including ablation and Wilcoxon signed-rank tests (p < 0.05), confirm significant contributions from residual shifting and regularization terms. RE-EDPM processes two 512x512 slices in about 0.25 s on modern GPUs, supporting near real-time clinical use. The proposed framework achieves an optimal balance between noise suppression and anatomical fidelity, offering an efficient solution for LDCT restoration and broader medical image enhancement tasks.

physics.med-ph↗

Res-MoCoDiff: Residual-guided diffusion models for motion artifact correction in brain MRI

Objective. Motion artifacts in brain MRI, mainly from rigid head motion, degrade image quality and hinder downstream applications. Conventional methods to mitigate these artifacts, including repeated acquisitions or motion tracking, impose workflow burdens. This study introduces Res-MoCoDiff, an efficient denoising diffusion probabilistic model specifically designed for MRI motion artifact correction.Approach.Res-MoCoDiff exploits a novel residual error shifting mechanism during the forward diffusion process to incorporate information from motion-corrupted images. This mechanism allows the model to simulate the evolution of noise with a probability distribution closely matching that of the corrupted data, enabling a reverse diffusion process that requires only four steps. The model employs a U-net backbone, with attention layers replaced by Swin Transformer blocks, to enhance robustness across resolutions. Furthermore, the training process integrates a combined l1+l2 loss function, which promotes image sharpness and reduces pixel-level errors. Res-MoCoDiff was evaluated on both an in-silico dataset generated using a realistic motion simulation framework and an in-vivo MR-ART dataset. Comparative analyses were conducted against established methods, including CycleGAN, Pix2pix, and a diffusion model with a vision transformer backbone, using quantitative metrics such as PSNR, SSIM, and NMSE.Main results. The proposed method demonstrated superior performance in removing motion artifacts across minor, moderate, and heavy distortion levels. Res-MoCoDiff consistently achieved the highest SSIM and the lowest NMSE values, with a PSNR of up to 41.91+-2.94 dB for minor distortions. Notably, the average sampling time was reduced to 0.37 seconds per batch of two image slices, compared with 101.74 seconds for conventional approaches.

cs.CV↗

DINOv3 with Test-Time Training for Medical Image Registration

Prior medical image registration approaches, particularly learning-based methods, often require large amounts of training data, which constrains clinical adoption. To overcome this limitation, we propose a training-free pipeline that relies on a frozen DINOv3 encoder and test-time optimization of the deformation field in feature space. Across two representative benchmarks, the method is accurate and yields regular deformations. On Abdomen MR-CT, it attained the best mean Dice score (DSC) of 0.790 together with the lowest 95th percentile Hausdorff Distance (HD95) of 4.9+-5.0 and the lowest standard deviation of Log-Jacobian (SDLogJ) of 0.08+-0.02. On ACDC cardiac MRI, it improves mean DSC to 0.769 and reduces SDLogJ to 0.11 and HD95 to 4.8, a marked gain over the initial alignment. The results indicate that operating in a compact foundation feature space at test time offers a practical and general solution for clinical registration without additional training.

cs.CV↗

Is ChatGPT-5 Ready for Mammogram VQA?

Mammogram visual question answering (VQA) integrates image interpretation with clinical reasoning and has potential to support breast cancer screening. We systematically evaluated the GPT-5 family and GPT-4o model on four public mammography datasets (EMBED, InBreast, CMMD, CBIS-DDSM) for BI-RADS assessment, abnormality detection, and malignancy classification tasks. GPT-5 consistently was the best performing model but lagged behind both human experts and domain-specific fine-tuned models. On EMBED, GPT-5 achieved the highest scores among GPT variants in density (56.8%), distortion (52.5%), mass (64.5%), calcification (63.5%), and malignancy (52.8%) classification. On InBreast, it attained 36.9% BI-RADS accuracy, 45.9% abnormality detection, and 35.0% malignancy classification. On CMMD, GPT-5 reached 32.3% abnormality detection and 55.0% malignancy accuracy. On CBIS-DDSM, it achieved 69.3% BI-RADS accuracy, 66.0% abnormality detection, and 58.2% malignancy accuracy. Compared with human expert estimations, GPT-5 exhibited lower sensitivity (63.5%) and specificity (52.3%). While GPT-5 exhibits promising capabilities for screening tasks, its performance remains insufficient for high-stakes clinical imaging applications without targeted domain adaptation and optimization. However, the tremendous improvements in performance from GPT-4o to GPT-5 show a promising trend in the potential for general large language models (LLMs) to assist with mammography VQA tasks.

cs.CV↗

Benchmarking GPT-5 for Zero-Shot Multimodal Medical Reasoning in Radiology and Radiation Oncology

Radiology, radiation oncology, and medical physics require decision-making that integrates medical images, textual reports, and quantitative data under high-stakes conditions. With the introduction of GPT-5, it is critical to assess whether recent advances in large multimodal models translate into measurable gains in these safety-critical domains. We present a targeted zero-shot evaluation of GPT-5 and its smaller variants (GPT-5-mini, GPT-5-nano) against GPT-4o across three representative tasks. We present a targeted zero-shot evaluation of GPT-5 and its smaller variants (GPT-5-mini, GPT-5-nano) against GPT-4o across three representative tasks: (1) VQA-RAD, a benchmark for visual question answering in radiology; (2) SLAKE, a semantically annotated, multilingual VQA dataset testing cross-modal grounding; and (3) a curated Medical Physics Board Examination-style dataset of 150 multiple-choice questions spanning treatment planning, dosimetry, imaging, and quality assurance. Across all datasets, GPT-5 achieved the highest accuracy, with substantial gains over GPT-4o up to +20.00% in challenging anatomical regions such as the chest-mediastinal, +13.60% in lung-focused questions, and +11.44% in brain-tissue interpretation. On the board-style physics questions, GPT-5 attained 90.7% accuracy (136/150), exceeding the estimated human passing threshold, while GPT-4o trailed at 78.0%. These results demonstrate that GPT-5 delivers consistent and often pronounced performance improvements over GPT-4o in both image-grounded reasoning and domain-specific numerical problem-solving, highlighting its potential to augment expert workflows in medical imaging and therapeutic physics.

eess.IV↗