arXiv ScienceSearch

arXiv subjects

Sen Qian

Publications and source records attributed to Sen Qian.

10 recordsLinked to original sources

Design of High-energy Proton-beam Experiment Station at CSNS

China's first proton test beam facility, named the High-energy Proton-beam Experiment Station (HPES), is currently under construction in campus of CSNS, as part of the CSNS-II project. Utilizing protons slowly extracted from the Rapid Cycling Synchrotron of CSNS, HPES will deliver 1.6 GeV proton beam with an adjustable flux ranging from 1E3 to 1E8 protons per second. The station is composed of two dedicated test terminals designed to support comprehensive beam tests, serving as an advanced platform for particle detector development, irradiation hardness studies of aerospace chips, and GeV-proton-induced nuclear data measurements.To characterize the beam, HPES incorporates dedicated flux and profile monitors. For user experiments, the facility is equipped with a high-precision proton telescope offering a positioning resolution of 10 $\mu$m, and a Time-of-Flight (TOF) spectrometer achieving an energy resolution of 1%. Furthermore, a compatible trigger logic unit have been designed to provide precise event tagging, which is essential for data alignment. This paper presents an overview of the detector systems within HPES, discusses their design considerations, and outlines the future prospects of the facility.

hep-ex

First experimental proof of PET imaging based on multi-anode MCP-PMTs with Cherenkov radiator-integrated window

Improving the coincidence time resolution (CTR) of time-of-flight positron emission tomography (TOF-PET) systems to achieve a higher signal-to-noise ratio (SNR) gain or even direct positron emission imaging (dPEI) is of paramount importance for many advanced new clinical applications of PET imaging. This places higher demands on the timing performance of all aspects of PET systems. One effective approach is to use microchannel plate photomultiplier tubes (MCP-PMTs) for prompt Cherenkov photon detection. In this study, we developed a dual-module Cherenkov PET imaging experimental platform, utilising our proprietary 8 * 8-anode Cherenkov radiator-integrated window MCP-PMTs in combination with custom-designed multi-channel electronics, and designed a specific calibration and correction method for the platform. Using this platform, a CTR of 103 ps FWHM was achieved. We overcame the limitations of single-anode detectors in previous experiments, significantly enhanced imaging efficiency and achieved module-level Cherenkov PET imaging for the first time. Imaging experiments involving radioactive sources and phantoms of various shapes and types were conducted, which preliminarily validated the feasibility and advancement of this imaging method. In addition, the effects of normalisation correction and the interaction probability between the gamma rays and the MCP on the images and experimental results were analysed and verified.

physics.ins-det

Flavor Physics at the CEPC: a General Perspective

We discuss the landscape of flavor physics at the Circular Electron-Positron Collider (CEPC), based on the nominal luminosity outlined in its Technical Design Report. The CEPC is designed to operate in multiple modes to address a variety of tasks. At the $Z$ pole, the expected production of 4 Tera $Z$ bosons will provide unique and highly precise measurements of $Z$ boson couplings, while the substantial number of boosted heavy-flavored quarks and leptons produced in clean $Z$ decays will facilitate investigations into their flavor physics with unprecedented precision. We investigate the prospects of measuring various physics benchmarks and discuss their implications for particle theories and phenomenological models. Our studies indicate that, with its highlighted advantages and anticipated excellent detector performance, the CEPC can explore beauty and $\tau$ physics in ways that are superior to or complementary with the Belle II and Large-Hadron-Collider-beauty experiments, potentially enabling the detection of new physics at energy scales of 10 TeV and above. This potential also extends to the observation of yet-to-be-discovered rare and exotic processes, as well as testing fundamental principles such as lepton flavor universality, lepton and baryon number conservation, etc., making the CEPC a vibrant platform for flavor physics research. The $WW$ threshold scan, Higgs-factory operation and top-pair productions of the CEPC further enhance its merits in this regard, especially for measuring the Cabibbo-Kobayashi-Maskawa matrix elements, and Flavor-Changing-Neutral-Current physics of Higgs boson and top quarks. We outline the requirements for detector performance and considerations for future development to achieve the anticipated scientific goals.

hep-ex

Muon beamtest results of high-density glass scintillator tiles

To achieve the physics goal of precisely measure the Higgs, Z, W bosons and the top quark, future electron-positron colliders require that their detector system has excellent jet energy resolution. One feasible technical option is the high granular calorimetery based on the particle flow algorithm (PFA). A new high-granularity hadronic calorimeter with glass scintillator tiles (GSHCAL) has been proposed, which focus on the significant improvement of hadronic energy resolution with a notable increase of the energy sampling fraction by using high-density glass scintillator tiles. The minimum ionizing particle (MIP) response of a glass scintillator tile is crucial to the hadronic calorimeter, so a dedicated beamtest setup was developed for testing the first batch of large-size glass scintillators. The maximum MIP response of the first batch of glass scintillator tiles can reach up to 107 p.e./MIP, which essentially meets the design requirements of the CEPC GSHCAL. An optical simulation model of a single glass scintillator tile has been established, and the simulation results are consistent with the beamtest results.

physics.ins-det

Single electron charge spectra of 8-inch high-collection-efficiency MCP-PMTs

The atomic layer deposition(ALD) coating lengthens the lifetime of microchannel plates(MCP), which are used as the electron amplifier of the photomultiplier tubes(PMT). In the Jinping Neutrino Experiment, the newly developed 8-inch MCP-PMT achieves high collection efficiency by coating with high secondary emission materials. The resulting single electron response(SER) charge distribution deviates from the Gaussian distribution in large charge regions.To understand the nature of the jumbo-charged SER, we designed a voltage-division experiment to quantify the dependence of the MCP gain on the energy of incident electrons. Combining the relationship with the Furman probabilistic model, we reproduced the SER charge spectra by an additional amplification stage on the input electrode of the first MCP. Our results favor a Gamma-Tweedie mixture to describe the SER charge spectra of the MCP-PMTs.

physics.ins-det

Design & Optimization of the HV divider for JUNO 20-inch PMT

The Jiangmen Underground Observatory (JUNO) is a 20-kton liquid scintillator detector that employs 20,000 20-inch photomultiplier tubes (PMTs) as photon sensors, with 5,000 dynode-PMTs from HAMAMATSU Photonics K.K. (HPK), and 15,000 MCP-PMTs from North Night Vision Technology (NNVT) installed in pure water. JUNO aims to provide long-lasting and the best performance operation by utilizing a high-transparency liquid scintillator, high detection efficiency PMTs, and specially designed electronics including water-proof potting for the high voltage (HV) dividers of PMTs. In this paper, we present a summary of the design and optimization of HV dividers for both types of 20-inch PMTs, which includes collection efficiency, charge resolution, HV divider current, pulse shape, and maximum amplitude restriction. We have developed and finalized four schemes of the HV divider for different scenarios, including the final version selected by JUNO. All 20,000 20-inch PMTs have successfully undergone production and burning tests.

physics.ins-det

Performance evaluation of the 8-inch MCP-PMT for Jinping Neutrino Experiment

Jinping Neutrino Experiment plans to deploy a new type of 8-inch MCP-PMT with high photon detection efficiency for MeV-scale neutrino measurements. This work studies the performance of the MCP-PMTs, including the photon detection efficiency, the charge resolution of the single photoelectron, the transition time spread, single photoelectron response, rates of dark counts and after pulses. We find a long tail in the charge distribution, and combined with the high photon detection efficiency, the overall energy resolution sees substantial improvements. Those results will be provided as the inputs to detector simulation and design. Our results show that the new PMT satisfies all the requirements of the Jinping Neutrino Experiment.

hep-ex

Evaluation of new large area PMT with high quantum efficiency

The neutrino detector of the Jiangmen Underground Neutrino Observatory (JUNO) is designed to use 20 kilotons of liquid scintillator and approximately 16,000 20-inch photomultipliers (PMTs).One of the options is to use the 20-inch R12860 PMT with high quantum efficiency which has recently been developed by Hamamatsu Photonics. The performance of the newly developed PMT preproduction samples is evaluated. The results show that its quantum efficiency is $30\%$ at $400 nm$. Its Peak/Valley (P/V) ratio for the single photoelectron is 4.75 and the dark count rate is $27 kHz$ at the threshold of 3 mV while the gain is at $1 \times 10^7$. The transit time spread of a single photoelectron is $2.86 ns$. Generally the performances of this new 20-inch PMT are improved over the old one of R3600.

physics.ins-det

The study of the aging behavior on large area MCP-PMT

Aging experiments of a novel type of large area MCP-PMT made by JUNO collaboration were conducted.In these aging experiments, the multi-photoelectron spectrum and single photoelectron spectrum were measured daily,as well as the MCP resistance of the second PMT before and after the experiment. Two PMTs were aged successivelyfor cross check. The first PMT was aged for 52 days, while the other one was aged for 84 days. In order to study the mechanism of the aging process, the high voltage on the second PMT was increased to accelerate its aging process when the cumulative output of charge from its anode was about 4 C. From our study, it can be known that large area MCP-PMT aging had a strong relationship with the related MCPs. In accordance with the PMT aging curve,a PMT aging model was setup and a general aging formula was given.

physics.ins-det

The high-speed after pulse measurement system for PMT

A system employing a desktop FADC has been developed to investigate the features of 8 inches Hamamatsu PMT. The system stands out for its high-speed and informative results as a consequence of adopting fast waveform sampling technology. Recording full waveforms allows us to perform digital signal processing, pulse shape analysis, and precision timing extraction. High precision after pulse time and charge distribution characteristics are presented in this manuscript. Other photomultipliers characteristics, such as dark rate and transit time spread, can also be obtained by exploiting waveform analysis using this system.

physics.ins-det