arXiv ScienceSearch

arXiv subjects

Sebastien Ourselin

Publications and source records attributed to Sebastien Ourselin.

At least 19 recordsLinked to original sources

Progressive Experience Fusion for Multi-Task World Model Control in Endovascular Navigation

Autonomous endovascular navigation could support the delivery of mechanical thrombectomy to underserved areas, but controllers must navigate long, multi-stage paths across varying vascular anatomies. This study investigates Progressive Experience Fusion (PEF) to train a multi-task TD-MPC2 controller. We additionally evaluate a heuristic that changes the Model Predictive Path Integral planning horizon using residual action-sequence dispersion, and fine-tuning in a patient-specific simulation. Across five subtasks in ten known training anatomies with held-out targets, PEF achieved a mean success rate of 74%, compared with 37% for Soft Actor-Critic (p < 0.001) and 65% for base TD-MPC2 (p = 0.053). A PEF controller with adaptive-horizon planning trained on 30 vasculatures achieved a mean success rate of 90% in ten held-out vasculatures. The PEF agent successfully transferred to an unseen in vitro stroke patient vasculature under fluoroscopy, achieving a mean path ratio improvement from 63% to 80% with fine-tuning (p < 0.001), following 40x103 fine-tuning steps (corresponding to approximately 107 min of clinical inter-hospital transfer time). This work represents a proof of concept for multi-vasculature training and patient-specific adaptation, while further validation is required before clinical deployment.

cs.RO

Eversion-based robots can enable safe access,steering and endoscopic imaging within the spinal subarachnoid space

Safe navigation within the spinal subarachnoid space is constrained by its narrow, compliant, and delicate anatomy. Conventional catheters and continuum robots rely on proximal pushing, generating friction and shear along the tissue device interface that limit distal controllability and increase the risk of neural injury. Here, we present a 2 mm diameter eversion-growing robotic platform that enables friction minimised extension and steering within the human spinal subarachnoid space, validated through computational modelling, phantom experiments, and intact human cadaver studies. The robot integrates a miniature endoscope for real time intrathecal visualisation and advances by pressure driven tip eversion, localising motion to the distal tip while minimising translational sliding of the deployed body. Phantom experiments demonstrated reductions of 65.2% in mean interaction force and 48.0% in peak interaction force compared with matched push-based insertion. Physics based modelling showed that eversion based growth redistributed tissue loading, reducing local stress concentrations and interfacial shear relative to conventional insertion. In an intact human cadaver, the system achieved 150 mm of controlled intrathecal extension with concurrent fluoroscopic and endoscopic visualisation, providing access across multiple vertebral levels from a standard lumbar entry point. Postprocedural laminectomy and durotomy revealed no observable macroscopic disruption of the dura mater or surrounding neural structures. These results provide the first mechanically characterised and multimodally validated demonstration of eversion-based robotic navigation in intact human spinal anatomy, establishing a quantitative and procedural foundation for future intrathecal interventions. Further validation in larger anatomical cohorts and under physiological conditions will be required before clinical translation.

cs.RO

Metadata Supervised MRI Representations for Modelling and Controlling Acquisition Variability

Magnetic resonance imaging exhibits substantial acquisition variability, where identical anatomy can appear markedly different across scanners and imaging protocols. Consequently, learned representations entangle biological structure with acquisition-dependent appearance, limiting interpretability, generalisation, and clinical deployment. We show that these sources of variation can be separated by jointly modelling MRI images and DICOM metadata. Using large-scale clinical brain MRI data, we learn representations that separate anatomical structure from contrast-dependent appearance. Resulting contrast representations organise heterogeneous acquisitions, support sequence understanding, and detect image--metadata inconsistencies, whereas anatomical representations suppress acquisition-specific variation while preserving biologically relevant information. Building on these disentangled representations, we introduce a unified anatomy-preserving harmonisation model for cross-modality and cross-site adaptation, conditioned on image or acquisition metadata. Our findings suggest that acquisition variability is a structured component of the imaging process that can be modelled, audited, and controlled, providing a foundation for acquisition-aware representation learning in large-scale medical imaging.

cs.CV

Stabilizing Temporal Inference Dynamics for Online Surgical Phase Recognition

Online Surgical Phase Recognition (SPR) models can reach high frame-wise accuracy, yet their predictions often lack temporal stability, fragmenting workflow understanding and reducing the reliability of downstream assistance. We show that this instability is not random noise but arises from two mechanisms: early misclassifications corrupt temporal feature states and propagate forward to form error cascades, and phase transitions follow evidence-accumulation dynamics whereas most online SPR systems rely on memoryless frame-wise decisions, making them sensitive to transient confidence fluctuations. We propose a unified Train-Inference-Evaluation framework that explicitly stabilizes temporal inference dynamics using model-agnostic, plug-and-play components. For training, the Temporal Error-Cascade (TEC) loss suppresses error onset and mitigates forward error propagation by stabilizing temporal feature evolution. For inference, the Evidence-Gated Transition Predictor (EGTP) enforces evidence-driven state transitions, allowing phase changes only when accumulated evidence exceeds a confidence boundary. For evaluation, we introduce the Temporal Fragmentation Index (TFI), a reliability-aware metric that quantifies instability-induced temporal disagreement beyond conventional frame-wise and token-based measures. Experiments on Cholec80 and AutoLaparo across three representative backbones show that the proposed framework substantially improves temporal stability and reduces prediction fragmentation, while maintaining or modestly improving frame-wise performance.

cs.CV

Three-dimensional intraoperative light field fluorescence imaging system for PpIX-guided tumour resection

Conventional 2D fluorescence imaging in glioma surgery cannot separate intrinsic fluorophore strength from attenuation with depth, creating depth-intensity ambiguity that can compromise assessment of residual tumour and fluorescence based grading. This study develops and validates a dual mode light field imaging system that could capture 3D structure and depth corrected fluorescence in a single snapshot by adapting a commercial Lytro Illum camera. A custom 3D printed depth standard was used to optimise main lens focal length and to derive a grayscale - distance linearity from Lytro Desktop depth maps. CdSe/ZnS quantum dot targets and fluorescent brain phantoms were imaged to establish fluorescence intensity distance attenuation models and to recover intrinsic fluorescence. In system optimisation, the increasing FU strengthened grayscale depth linearity and achieved millimetre scale vertical resolution ($R^{2}$ > 0.95) for FU $\ge$ 60 mm. Higher concentration quantum dot wells of the fluorescent target showed consistent attenuation. In fluorescence mode, the deviations of distance estimations across six regions of a fluorescent brain phantom were 0.14 to 2.45% with intensity prediction errors from -11.73% to 6.08% based on the fluorescence intensity-distance model, enabling recovery of intrinsic quantum dot concentrations which are mimicking PpIX characteristics in glioma. This research supports light field imaging as a practical approach for depth resolved quantitative fluorescence and improved intraoperative tumour characterisation.

physics.med-ph

CLoPA: Continual Low Parameter Adaptation of Interactive Segmentation for Medical Image Annotation

Interactive segmentation enables clinicians to guide annotation, but existing zero-shot models like nnInteractive fail to consistently reach expert-level performance across diverse medical imaging tasks. Because annotation campaigns produce a growing stream of task-specific labelled data, online adaptation of the segmentation model is a natural complement to zero-shot inference. We propose CLoPA, a continual adaptation strategy that tunes a small fraction of nnInteractive's parameters on the annotation cache, triggered by lightweight episode scheduling. CLoPA requires no new parameters or changes to the inference pipeline, and operates entirely within the existing annotation workflow. Across eight Medical Segmentation Decathlon tasks spanning diverse anatomical targets and imaging characteristics, CLoPA rapidly elevates performance to expert-level, even for tasks where nnInteractive previously failed, with the majority of gains realised after a single training episode. We show that the benefits of tuning different parameter groups depends on task characteristics and data regimes. Also, that for targets with complex geometries (e.g., hepatic vessels), instance normalisation and low-level feature tuning saturates, suggesting a need for deeper feature-representation alignment in the most challenging scenarios.

cs.CV

From Pre- to Intra-operative MRI: Predicting Brain Shift in Temporal Lobe Resection for Epilepsy Surgery

Introduction: In neurosurgery, image-guided Neurosurgery Systems (IGNS) highly rely on preoperative brain magnetic resonance images (MRI) to assist surgeons in locating surgical targets and determining surgical paths. However, brain shift invalidates the preoperative MRI after dural opening. Updated intraoperative brain MRI with brain shift compensation is crucial for enhancing the precision of neuronavigation systems and ensuring the optimal outcome of surgical interventions. Methodology: We propose NeuralShift, a U-Net-based model that predicts brain shift entirely from pre-operative MRI for patients undergoing temporal lobe resection. We evaluated our results using Target Registration Errors (TREs) computed on anatomical landmarks located on the resection side and along the midline, and DICE scores comparing predicted intraoperative masks with masks derived from intraoperative MRI. Results: Our experimental results show that our model can predict the global deformation of the brain (DICE of 0.97) with accurate local displacements (achieve landmark TRE as low as 1.12 mm), compensating for large brain shifts during temporal lobe removal neurosurgery. Conclusion: Our proposed model is capable of predicting the global deformation of the brain during temporal lobe resection using only preoperative images, providing potential opportunities to the surgical team to increase safety and efficiency of neurosurgery and better outcomes to patients. Our contributions will be publicly available after acceptance in https://github.com/SurgicalDataScienceKCL/NeuralShift.

cs.CV

Enabling High-Curvature Navigation in Eversion Robots through Buckle-Inducing Constrictive Bands

Tip-growing eversion robots are renowned for their ability to access remote spaces through narrow passages. However, achieving reliable navigation remains a significant challenge. Existing solutions often rely on artificial muscles integrated into the robot body or active tip-steering mechanisms. While effective, these additions introduce structural complexity and compromise the defining advantages of eversion robots: their inherent softness and compliance. In this paper, we propose a passive approach to reduce bending stiffness by purposefully introducing buckling points along the robot's outer wall. We achieve this by integrating inextensible diameter-reducing circumferential bands at regular intervals along the robot body facilitating forward motion through tortuous, obstacle cluttered paths. Rather than relying on active steering, our approach leverages the robot's natural interaction with the environment, allowing for smooth, compliant navigation. We present a Cosserat rod-based mathematical model to quantify this behavior, capturing the local stiffness reductions caused by the constricting bands and their impact on global bending mechanics. Experimental results demonstrate that these bands reduce the robot's stiffness when bent at the tip by up to 91 percent, enabling consistent traversal of 180 degree bends with a bending radius of as low as 25 mm-notably lower than the 35 mm achievable by standard eversion robots under identical conditions. The feasibility of the proposed method is further demonstrated through a case study in a colon phantom. By significantly improving maneuverability without sacrificing softness or increasing mechanical complexity, this approach expands the applicability of eversion robots in highly curved pathways, whether in relation to pipe inspection or medical procedures such as colonoscopy.

cs.RO

DIST-CLIP: Arbitrary Metadata and Image Guided MRI Harmonization via Disentangled Anatomy-Contrast Representations

Deep learning holds immense promise for transforming medical image analysis, yet its clinical generalization remains profoundly limited. A major barrier is data heterogeneity. This is particularly true in Magnetic Resonance Imaging, where scanner hardware differences, diverse acquisition protocols, and varying sequence parameters introduce substantial domain shifts that obscure underlying biological signals. Data harmonization methods aim to reduce these instrumental and acquisition variability, but existing approaches remain insufficient. When applied to imaging data, image-based harmonization approaches are often restricted by the need for target images, while existing text-guided methods rely on simplistic labels that fail to capture complex acquisition details or are typically restricted to datasets with limited variability, failing to capture the heterogeneity of real-world clinical environments. To address these limitations, we propose DIST-CLIP (Disentangled Style Transfer with CLIP Guidance), a unified framework for MRI harmonization that flexibly uses either target images or DICOM metadata for guidance. Our framework explicitly disentangles anatomical content from image contrast, with the contrast representations being extracted using pre-trained CLIP encoders. These contrast embeddings are then integrated into the anatomical content via a novel Adaptive Style Transfer module. We trained and evaluated DIST-CLIP on diverse real-world clinical datasets, and showed significant improvements in performance when compared against state-of-the-art methods in both style translation fidelity and anatomical preservation, offering a flexible solution for style transfer and standardizing MRI data. Our code and weights will be made publicly available upon publication.

cs.CV

Real-time 3D Ultrasonic Needle Tracking with a Photoacoustic Beacon

Many minimally invasive procedures, such as core needle biopsy of focal liver lesions, nerve blocks, and fetal and vascular interventions, are typically performed under ultrasound guidance, which provides real-time, high-resolution visualisation of tissue anatomy. Accurate and efficient localisation of the needle tip relative to patient anatomy is essential for guiding the needle towards the procedure target, avoiding adverse events and reducing the need for repeat procedures. However, the 3D nature of the procedure and poor image contrast of the needle in heterogeneous tissue or at steep insertion angles often lead to confusion over the true location of the tip within the 2D guidance images, and existing methods to enhance needle visibility largely remain limited to 2D. Here, we present a novel interventional ultrasound system capable of 2D B-mode imaging and 3D needle tracking. The tip location is determined from the time-of-flight of ultrasound generated by a photoacoustic beacon embedded in the needle bevel and received by a sparse receiver array distributed around the imaging system's curvilinear ultrasound probe. The measured tracking accuracy was better than 2 mm for depths up to 140 mm in water, and approximately 2 mm on average in an ex vivo tissue phantom, with referenced positions derived from X-ray computed tomography. In a usability study involving 12 clinicians performing biopsy procedures in a ex vivo tissue phantom, the failure rate was reduced by 35%, from 15.8% to 10.3% after only a few minutes of training. These results demonstrate that the proposed system has strong potential to support a wide range of minimally invasive procedures by enabling clinicians to accurately target small anatomical structures, improving the efficiency and effectiveness of diagnostic sampling and therapeutic delivery or ablation, and reducing the risk of adverse events.

physics.med-ph

LIHE: Linguistic Instance-Split Hyperbolic-Euclidean Framework for Generalized Weakly-Supervised Referring Expression Comprehension

Existing Weakly-Supervised Referring Expression Comprehension (WREC) methods, while effective, are fundamentally limited by a one-to-one mapping assumption, hindering their ability to handle expressions corresponding to zero or multiple targets in realistic scenarios. To bridge this gap, we introduce the Weakly-Supervised Generalized Referring Expression Comprehension task (WGREC), a more practical paradigm that handles expressions with variable numbers of referents. However, extending WREC to WGREC presents two fundamental challenges: supervisory signal ambiguity, where weak image-level supervision is insufficient for training a model to infer the correct number and identity of referents, and semantic representation collapse, where standard Euclidean similarity forces hierarchically-related concepts into non-discriminative clusters, blurring categorical boundaries. To tackle these challenges, we propose a novel WGREC framework named Linguistic Instance-Split Hyperbolic-Euclidean (LIHE), which operates in two stages. The first stage, Referential Decoupling, predicts the number of target objects and decomposes the complex expression into simpler sub-expressions. The second stage, Referent Grounding, then localizes these sub-expressions using HEMix, our innovative hybrid similarity module that synergistically combines the precise alignment capabilities of Euclidean proximity with the hierarchical modeling strengths of hyperbolic geometry. This hybrid approach effectively prevents semantic collapse while preserving fine-grained distinctions between related concepts. Extensive experiments demonstrate LIHE establishes the first effective weakly supervised WGREC baseline on gRefCOCO and Ref-ZOM, while HEMix achieves consistent improvements on standard REC benchmarks, improving IoU@0.5 by up to 2.5\%. The code is available at https://anonymous.4open.science/r/LIHE.

cs.CV

Light Focusing through Dynamic Media via Real-Valued Intensity Transmission Matrix

Precise light delivery through biological tissue is essential for deep-tissue imaging and phototherapeutic applications. Wavefront shaping enables control over scattered light by modulating the incident wavefront, but its application in living tissue is hindered by tissue-induced temporal decorrelation. This study systematically investigated the real-valued intensity transmission matrix (RVITM), a high-speed wavefront shaping method, for light focusing across a broad range of speckle decorrelation times. The inherent trade-off between static light focusing enhancement and implementation speed is characterized, which provided practical guidelines for implementing RVITM in real-time wavefront shaping under varying dynamic conditions. Effective optical focusing using a RVITM with 33 ms runtime was achieved through porcine liver with decorrelation times as short as 13 ms, demonstrating feasibility for biologically relevant dynamics and supporting the development of adaptive, non-invasive optical control for biomedical applications.

physics.optics

Dynamic causal discovery in Alzheimer's disease through latent pseudotime modelling

The application of causal discovery to diseases like Alzheimer's (AD) is limited by the static graph assumptions of most methods; such models cannot account for an evolving pathophysiology, modulated by a latent disease pseudotime. We propose to apply an existing latent variable model to real-world AD data, inferring a pseudotime that orders patients along a data-driven disease trajectory independent of chronological age, then learning how causal relationships evolve. Pseudotime outperformed age in predicting diagnosis (AUC 0.82 vs 0.59). Incorporating minimal, disease-agnostic background knowledge substantially improved graph accuracy and orientation. Our framework reveals dynamic interactions between novel (NfL, GFAP) and established AD markers, enabling practical causal discovery despite violated assumptions.

stat.AP

Metadata-Aligned 3D MRI Representations for Contrast Understanding and Quality Control

Magnetic Resonance Imaging suffers from substantial data heterogeneity and the absence of standardized contrast labels across scanners, protocols, and institutions, which severely limits large-scale automated analysis. A unified representation of MRI contrast would enable a wide range of downstream utilities, from automatic sequence recognition to harmonization and quality control, without relying on manual annotations. To this end, we introduce MR-CLIP, a metadata-guided framework that learns MRI contrast representations by aligning volumetric images with their DICOM acquisition parameters. The resulting embeddings shows distinct clusters of MRI sequences and outperform supervised 3D baselines under data scarcity in few-shot sequence classification. Moreover, MR-CLIP enables unsupervised data quality control by identifying corrupted or inconsistent metadata through image-metadata embedding distances. By transforming routinely available acquisition metadata into a supervisory signal, MR-CLIP provides a scalable foundation for label-efficient MRI analysis across diverse clinical datasets.

cs.CV

MambaX-Net: Dual-Input Mamba-Enhanced Cross-Attention Network for Longitudinal Prostate MRI Segmentation

Active Surveillance (AS) is a treatment option for managing low and intermediate-risk prostate cancer (PCa), aiming to avoid overtreatment while monitoring disease progression through serial MRI and clinical follow-up. Accurate prostate segmentation is an important preliminary step for automating this process, enabling automated detection and diagnosis of PCa. However, existing deep-learning segmentation models are often trained on single-time-point, expertly annotated datasets, making them unsuitable for longitudinal AS analysis, where multiple time points and a scarcity of expert labels hinder effective fine-tuning. To address these challenges, we propose MambaX-Net, a novel semi-supervised, dual-scan 3D segmentation architecture that computes the segmentation for time point t by leveraging the MRI and the corresponding segmentation mask from the previous time point. We introduce two new components: (i) a Mamba-enhanced Cross-Attention Module, which integrates the Mamba block into cross-attention to efficiently capture temporal evolution and long-range spatial dependencies, and (ii) a Shape Extractor Module that encodes the previous segmentation mask into a latent anatomical representation for refined zone delineation. Moreover, we use a semi-supervised self-training strategy that leverages pseudo-labels generated from a pre-trained nnU-Net, enabling effective learning without expert annotations. MambaX-Net was evaluated on a longitudinal AS dataset, and results showed that it significantly outperforms state-of-the-art U-Net and Transformer-based models, achieving superior prostate zone segmentation even when trained on limited and noisy data.

cs.CV

A methodology for clinically driven interactive segmentation evaluation

Interactive segmentation is a promising strategy for building robust, generalisable algorithms for volumetric medical image segmentation. However, inconsistent and clinically unrealistic evaluation hinders fair comparison and misrepresents real-world performance. We propose a clinically grounded methodology for defining evaluation tasks and metrics, and built a software framework for constructing standardised evaluation pipelines. We evaluate state-of-the-art algorithms across heterogeneous and complex tasks and observe that (i) minimising information loss when processing user interactions is critical for model robustness, (ii) adaptive-zooming mechanisms boost robustness and speed convergence, (iii) performance drops if validation prompting behaviour/budgets differ from training, (iv) 2D methods perform well with slab-like images and coarse targets, but 3D context helps with large or irregularly shaped targets, (v) performance of non-medical-domain models (e.g. SAM2) degrades with poor contrast and complex shapes.

cs.CV

A Fully Open and Generalizable Foundation Model for Ultrasound Clinical Applications

Artificial intelligence (AI) that can effectively learn ultrasound representations by integrating multi-source data holds significant promise for advancing clinical care. However, the scarcity of large labeled datasets in real-world clinical environments and the limited generalizability of task-specific models have hindered the development of generalizable clinical AI models for ultrasound applications. In this study, we present EchoCare, a novel ultrasound foundation model for generalist clinical use, developed via self-supervised learning on our curated, publicly available, large-scale dataset EchoCareData. EchoCareData comprises 4.5 million ultrasound images, sourced from over 23 countries across 5 continents and acquired via a diverse range of distinct imaging devices, thus encompassing global cohorts that are multi-center, multi-device, and multi-ethnic. Unlike prior studies that adopt off-the-shelf vision foundation model architectures, we introduce a hierarchical classifier into EchoCare to enable joint learning of pixel-level and representation-level features, capturing both global anatomical contexts and local ultrasound characteristics. With minimal training, EchoCare outperforms state-of-the-art comparison models across 10 representative ultrasound benchmarks of varying diagnostic difficulties, spanning disease diagnosis, lesion segmentation, organ detection, landmark prediction, quantitative regression, imaging enhancement and report generation. The code and pretrained model are publicly released, rendering EchoCare accessible for fine-tuning and local adaptation, supporting extensibility to additional applications. EchoCare provides a fully open and generalizable foundation model to boost the development of AI technologies for diverse clinical ultrasound applications.

cs.CV

Volumetric ultrasound imaging with a sparse matrix array and integrated fiber-optic sensing for robust needle tracking in interventional procedures

Accurate visualization of interventional devices, such as medical needles, is essential for the safe and effective guidance of minimally invasive procedures. Ultrasound (US) imaging is widely used for needle guidance, but the two-dimensional nature of most clinical probes limits accurate three-dimensional (3D) localization, particularly of the needle tip. We present a novel system that integrates volumetric US imaging with 3D needle tracking by combining a fiber-optic hydrophone embedded in the needle and a sparse spiral US array. Real-time volumetric imaging was achieved using plane-wave techniques, while precise needle tip tracking was enabled through communication between the probe and hydrophone. The feasibility of the approach was demonstrated using a nerve block training phantom. This proof-of-concept system enables simultaneous volumetric anatomical imaging and 3D needle tip tracking, with strong potential to enhance the efficacy and safety of image-guided interventional procedures.

physics.med-ph