Segmentation of the aorta in 4D flow MRI using 4D convolutional kernels and learning from sparse annotations

Automated aortic segmentation in 4D flow MRI is essential for reproducible hemodynamic assessment but is limited by scarce dense annotations and high computational demands. We developed a fully automated 4D (3D+time) U-Net for segmenting the ascending aorta, arch, and proximal descending aorta, using a parameter-efficient hybrid 4D kernel to capture temporal context and sparse 4D labels derived from existing 2D expert contours and centerlines, thereby avoiding the need for dense 4D annotations. Training comprised 268 scans from 8 centers and 2 vendors, with evaluation on an internal test set (32 scans) and an external post-contrast set (30 scans; different site, protocol, and annotator), compared against frame-wise 3D networks and two semi-automatic references. Against time-resolved annotations, the 4D U-Net achieved Dice scores of 0.927 (internal) and 0.911 (external), versus 0.919/0.847 for the 3D U-Net, 0.893 for static PC-MRA, and 0.808 for registration-based propagation; differences were small in systole but pronounced in diastole. Agreement with expert contours for peak velocity, net flow, axial and circumferential wall shear stress, and diameters was excellent (ICC >=0.954 internal, >=0.980 external), while semi-automatic references performed worse. The method thus provides reproducible, time-resolved aortic segmentation for automated hemodynamic analysis and generalizes across multicenter, multivendor, and independent post-contrast data. The model is publicly available.

cs.CV

Uncovering Turbulent Dynamics in Stenotic Flows from 4D-flow MRI Measurements via Resolvent Analysis and Data Assimilation

This study presents a hybrid experimental and computational framework that couples in vitro 4D phase-contrast magnetic resonance imaging (4D-flow MRI) measurements with data assimilation and linear modeling to characterize the flow linear amplification mechanisms. We manufacture an idealized stenosis phantom with a cosine-shaped contraction and acquire three-dimensional (3D) mean velocity measurements at Reynolds number 3960 using 4D-flow MRI. To overcome the inherent displacement artifact, we perform data assimilation via a two-step optimization strategy using physics-informed neural network (PINN). This approach first corrects measurement artifacts before extracting the unknown mean pressure and eddy viscosity fields. The RANS-compatible mean flow then serves as the base state for global linear stability analysis (LSA) and resolvent analysis. The global LSA reveals stationary eigenmodes located in the recirculation bubble that exhibit a positive growth rate for azimuthal wavenumbers m=2 and m=3. The forced dynamics of this eigenmode dominates the low-frequency dynamics. Resolvent analysis identifies a broadband pseudo-resonance associated with the convective instability of the separated shear-layer, with maximal amplification for m=0. This methodology demonstrates how integrating sparse experimental MRI data with physics-based modeling enables the identification of mean fields and coherent structures. By leveraging the capabilities of 4D-flow MRI to non-invasively measure 3D velocity fields without requiring physical or optical access, this approach is a first step in the application of linear analysis to cardiovascular flows.

physics.flu-dyn

CaroTo: A Tool for Fast Comprehensive Analysis of Carotid Artery Stenosis in 4D PC- and 3D BB-MRI Data

Atherosclerosis of the carotid artery increases stroke risk. Atherosclerosis assessment with MRI requires multimodal and multidimensional segmentation of the carotid artery, reproducible extraction of biomarkers, and the visualization of segmentations and biomarkers. We developed CaroTo, a tool that allows for standardized carotid atherosclerosis assessment. It combines the capabilities of MEVISFlow with specialized tools for carotid geometry and vessel wall assessment. It supports manual and automatic segmentation for 2D, 2D+time, and 3D images, facilitating precise and consistent evaluations of carotid artery stenosis.

eess.IV

Learning Wall Segmentation in 3D Vessel Trees using Sparse Annotations

We propose a novel approach that uses sparse annotations from clinical studies to train a 3D segmentation of the carotid artery wall. We use a centerline annotation to sample perpendicular cross-sections of the carotid artery and use an adversarial 2D network to segment them. These annotations are then transformed into 3D pseudo-labels for training of a 3D convolutional neural network, circumventing the creation of manual 3D masks. For pseudo-label creation in the bifurcation area we propose the use of cross-sections perpendicular to the bifurcation axis and show that this enhances segmentation performance. Different sampling distances had a lesser impact. The proposed method allows for efficient training of 3D segmentation, offering potential improvements in the assessment of carotid artery stenosis and allowing the extraction of 3D biomarkers such as plaque volume.

cs.CV

Carotid Artery Plaque Analysis in 3D Based on Distance Encoding in Mesh Representations

Purpose: Enabling a comprehensive and robust assessment of carotid artery plaques in 3D through extraction and visualization of quantitative plaque parameters. These parameters have potential applications in stroke risk analysis, evaluation of therapy effectiveness, and plaque progression prediction. Methods: We propose a novel method for extracting a plaque mesh from 3D vessel wall segmentation using distance encoding on the inner and outer wall mesh for precise plaque structure analysis. A case-specific threshold, derived from the normal vessel wall thickness, was applied to extract plaques from a dataset of 202 T1-weighted black-blood MRI scans of subjects with up to 50% stenosis. Applied to baseline and one-year follow-up data, the method supports detailed plaque morphology analysis over time, including plaque volume quantification, aided by improved visualization via mesh unfolding. Results: We successfully extracted plaque meshes from 341 carotid arteries, capturing a wide range of plaque shapes with volumes ranging from 2.69μl to 847.7μl. The use of a case-specific threshold effectively eliminated false positives in young, healthy subjects. Conclusion: The proposed method enables precise extraction of plaque meshes from 3D vessel wall segmentation masks enabling a correspondence between baseline and one-year follow-up examinations. Unfolding the plaque meshes enhances visualization, while the mesh-based analysis allows quantification of plaque parameters independent of voxel resolution.

cs.CV

DeepControl: 2D RF pulses facilitating $B_1^+$ inhomogeneity and $B_0$ off-resonance compensation in vivo at 7T

Purpose: Rapid 2D RF pulse design with subject specific $B_1^+$ inhomogeneity and $B_0$ off-resonance compensation at 7 T predicted from convolutional neural networks is presented. Methods: The convolution neural network was trained on half a million single-channel transmit, 2D RF pulses optimized with an optimal control method using artificial 2D targets, $B_1^+$ and $B_0$ maps. Predicted pulses were tested in a phantom and in vivo at 7 T with measured $B_1^+$ and $B_0$ maps from a high-resolution GRE sequence. Results: Pulse prediction by the trained convolutional neural network was done on the fly during the MR session in approximately 9 ms for multiple hand drawn ROIs and the measured $B_1^+$ and $B_0$ maps. Compensation of $B_1^+$ inhomogeneity and $B_0$ off-resonances has been confirmed in the phantom and in vivo experiments. The reconstructed image data agrees well with the simulations using the acquired $B_1^+$ and $B_0$ maps and the 2D RF pulse predicted by the convolutional neural networks is as good as the conventional RF pulse obtained by optimal control. Conclusion: The proposed convolutional neural network based 2D RF pulse design method predicts 2D RF pulses with an excellent excitation pattern and compensated $B_1^+$ and $B_0$ variations at 7 T. The rapid 2D RF pulse prediction (9 ms) enables subject-specific high-quality 2D RF pulses without the need to run lengthy optimizations.