arXiv Science⌕ Search

arXiv subjects

Saptarshi Purkayastha

Publications and source records attributed to Saptarshi Purkayastha.

At least 19 recordsLinked to original sources

Preference vs. Performance: EEG-Based Classification of Learner Engagement in Multimodal Instruction

Effective adaptive instructional systems require robust measures of learner engagement that go beyond static user profiles. This study employs Multimodal Learning Analytics (MMLA) to investigate the relationship between self-reported instructional modality preferences and objective neurophysiological markers of engagement. Thirty-seven participants engaged with learning content delivered via varying modalities (visual, auditory, reading/writing, kinesthetic). We captured real-time neural activity using two EEG devices: the Emotiv EpocX (14 channels, 128 Hz) and OpenBCI (16 channels, 125 Hz). Preferences were assessed using the VARK questionnaire. Consistent with literature challenging the "meshing hypothesis," aligning instructional modality with stated preferences did not significantly predict performance gains. However, spectral analysis of EEG data revealed divergent engagement patterns: when content aligned with preferences, distinct neural activity patterns emerged in theta and alpha frequency bands-markers associated with attention and cognitive processing. These signals were used to train a binary logistic regression classifier, achieving a mean accuracy of 83.21% with OpenBCI and 56.27% with Emotiv EpocX. These findings suggest that while self-reported preferences may not dictate learning outcomes, they significantly influence neurophysiological engagement, offering a viable, non-invasive input for adaptive educational algorithms.

cs.HC↗

Machine Learning for Pre-Culture ESBL Risk Stratification to Guide Empiric Antibiotic Selection: A 12-Hospital Study of Enterobacteriaceae Cultures

Empiric antibiotic therapy for suspected ESBL-producing Enterobacteriaceae must be selected 48-72 hours before culture results, forcing clinicians to choose between undertreating resistant infections and overusing carbapenems that drive further resistance. We developed a cost-sensitive XGBoost model predicting an ESBL phenotype (resistance to ceftriaxone, ceftazidime, cefepime or piperacillin-tazobactam) at culture ordering using 45 pre-culture EHR features across 132,955 cultures from 72,217 patients at 12 hospitals (14.41% with the ESBL phenotype). Cultures were partitioned at the patient level. At 90% sensitivity, the model achieved 95.8% NPV, reducing post-test ESBL probability to 4.2%, a threshold that may support safe carbapenem-sparing in non-ICU settings, while sparing 307 of every 1,000 cultures an unnecessary broad-spectrum course at the cost of 14 missed ESBL cases per 1,000. SHAP analysis identified prior ESBL colonization as the dominant predictor, ahead of prior organism burden and neighborhood deprivation; removing deprivation features caused minimal performance loss ($Δ\text{AUROC} = -0.020$), enabling equitable bedside deployment. Discrimination was unchanged under a strict IDSA ESBL-E definition (AUROC 0.766), with specimen type added as a predictor (0.764) and without any class-imbalance correction (0.762), and ranged from 0.71 to 0.78 across organism strata.

cs.LG↗

Predicting Early Functional Decline from Longitudinal Laboratory and Vital Sign Trajectories: A Large-Scale Study Using the All of Us Research Program

Functional decline in older adults is typically recognized only after falls or observable gait impairment, closing the window for prevention. We investigated whether temporal trajectories of routine biomarkers, already recorded but rarely analyzed longitudinally, can identify patients in the pre-clinical phase of mobility decline. Using the All of Us Research Program (N = 297,861; 11.1% cases), we derived trajectory features (slope, variability, delta, mean) for twelve biomarkers over a three-year pre-index window. LightGBM models incorporating trajectories significantly outperformed static laboratory summaries (AUROC 0.797 vs. 0.755; DeLong p < 0.001; AUPRC 0.380 vs. 0.304). A 1:1 age- and sex-matched analysis confirmed an independent trajectory signal (AUROC 0.727 vs. demographics-only 0.680). A horizon analysis demonstrated sustained prediction 3-12 months before decline onset (AUROC 0.768-0.740). Because the model uses only measurements already ordered in routine care, it supports passive, zero-burden EHR integration for early detection of pre-clinical functional decline.

cs.LG↗

Multimodal EEG-IMU Fusion for Motor Assessment: Leveraging Task-Dependent Complementarity for Robustness

Movement disorders such as Parkinson's disease require comprehensive motor assessment, but reliable digital assessment pipelines integrating multiple sensing modalities across diverse motor tasks remain insufficiently characterized. We present a proof-of-concept study evaluating task-specific modality performance and multimodal fusion across ten motor activities. Synchronized EEG-IMU data were recorded from six participants (52 recording pairs). We evaluated an EEGNet + Transformer model for 16-channel EEG (125 Hz) and XGBoost on hand-crafted accelerometer and gyroscope features (25 Hz). Under 5-fold cross-validation in a subject-dependent setting, IMU achieved 94.41+/-0.58% accuracy and outperformed EEG on 7 of 10 activities, while EEG achieved 92.82+/-1.45% and showed lower error for rhythmic cycling (4.03% vs. 12.10%). Late fusion via logistic regression reached 98.68+/-0.32%, giving an 81.5% error reduction versus EEG alone and improving worst-task accuracy from approximately 87% for a single modality to 96.76%. Fusion also reduced cross-task performance variance from approximately 3% to 1.06% (paired t-test, p < 0.001, df = 4; p-values approximate given fold dependence), showing more uniform reliability across the assessment battery. Although the small sample limits generalizability, these results suggest that EEG and IMU provide asymmetric, task-dependent strengths and that late fusion can leverage this complementarity to improve assessment reliability. This study provides methodological and empirical motivation for larger-scale clinical validation in movement disorder populations.

eess.SP↗

Frozen Foundation-Model Embeddings Discard Small-Lesion Signal in Chest Radiography: Implications for Pre-Deployment Evaluation

Frozen vision-transformer (ViT) foundation-model embeddings increasingly serve as the substrate for downstream chest-radiography (CXR) pipelines, yet where small-scale, low-contrast signal is retained or lost in the frozen forward pass has not been systematically quantified across architectures, pretraining domains, and objectives. We probed five frozen ViTs (RAD-DINO, DINOv2-B/14, DINOv3 ViT-7B, BiomedCLIP, MedSigLIP) and a frozen DINO-pretrained ResNet-50 architectural control across three large CXR cohorts (NIH-CXR14, MIMIC-CXR, Emory-CXR; aggregate pool n=492,724) and ChestX-Det10 (n=3,543; 1,462 small-lesion bounding boxes across Calcification, Nodule, Mass). Each model was evaluated with a small-scale-perturbation panel and a region-aware bounding-box-stratified probe on real lesions, comparing three pooling modes from the same forward pass: classification token (CLS), patch-mean (mean over all final-layer patch tokens), and bounding-box-restricted patch-local. On the perturbation panel, CLS embeddings sat at the chance floor (area under the ROC curve [AUC] 0.500-0.524); patch-mean was indistinguishable from CLS on iso-blur and reticular-fine cells but rose with CLS on larger directional-blur footprints, while disease AUC on globally decided tasks ranged 0.642-0.913. Patch-local probes recovered AUC ~1.0 from the same forward pass (per-model mean improvement +0.412 to +0.488); the ResNet-50 control reproduced the chance floor. On ChestX-Det10, image-level CLS classification showed within-class small-versus-large stratum gaps up to +0.243 AUC; bounding-box-level patch-local pooling on the same forward pass recovered AUC >= 0.899 on every (model x class) cell. Frozen ViT embeddings silently suppress small-scale signal at the global-aggregation step; the signal is recoverable from patch tokens conditional on a region of interest.

cs.CV↗

Human-Guided Agentic AI for Multimodal Clinical Prediction: Lessons from the AgentDS Healthcare Benchmark

Agentic AI systems are increasingly capable of autonomous data science workflows, yet clinical prediction tasks demand domain expertise that purely automated approaches struggle to provide. We investigate how human guidance of agentic AI can improve multimodal clinical prediction, presenting our approach to all three AgentDS Healthcare benchmark challenges: 30-day hospital readmission prediction (Macro-F1 = 0.8986), emergency department cost forecasting (MAE = $465.13), and discharge readiness assessment (Macro-F1 = 0.7939). Across these tasks, human analysts directed the agentic workflow at key decision points, multimodal feature engineering from clinical notes, scanned PDF billing receipts, and time-series vital signs; task-appropriate model selection; and clinically informed validation strategies. Our approach ranked 5th overall in the healthcare domain, with a 3rd-place finish on the discharge readiness task. Ablation studies reveal that human-guided decisions compounded to a cumulative gain of +0.065 F1 over automated baselines, with multimodal feature extraction contributing the largest single improvement (+0.041 F1). We distill three generalizable lessons: (1) domain-informed feature engineering at each pipeline stage yields compounding gains that outperform extensive automated search; (2) multimodal data integration requires task-specific human judgment that no single extraction strategy generalizes across clinical text, PDFs, and time-series; and (3) deliberate ensemble diversity with clinically motivated model configurations outperforms random hyperparameter search. These findings offer practical guidance for teams deploying agentic AI in healthcare settings where interpretability, reproducibility, and clinical validity are essential.

cs.AI↗

Feature Quality and Adaptability of Medical Foundation Models: A Comparative Evaluation for Radiographic Classification and Segmentation

Foundation models (FMs) promise to generalize medical imaging, but their effectiveness varies. It remains unclear how pre-training domain (medical vs. general), paradigm (e.g., text-guided), and architecture influence embedding quality, hindering the selection of optimal encoders for specific radiology tasks. To address this, we evaluate vision encoders from eight medical and general-domain FMs for chest X-ray analysis. We benchmark classification (pneumothorax, cardiomegaly) and segmentation (pneumothorax, cardiac boundary) using linear probing and fine-tuning. Our results show that domain-specific pre-training provides a significant advantage; medical FMs consistently outperformed general-domain models in linear probing, establishing superior initial feature quality. However, feature utility is highly task-dependent. Pre-trained embeddings were strong for global classification and segmenting salient anatomy (e.g., heart). In contrast, for segmenting complex, subtle pathologies (e.g., pneumothorax), all FMs performed poorly without significant fine-tuning, revealing a critical gap in localizing subtle disease. Subgroup analysis showed FMs use confounding shortcuts (e.g., chest tubes for pneumothorax) for classification, a strategy that fails for precise segmentation. We also found that expensive text-image alignment is not a prerequisite; image-only (RAD-DINO) and label-supervised (Ark+) FMs were among top performers. Notably, a supervised, end-to-end baseline remained highly competitive, matching or exceeding the best FMs on segmentation tasks. These findings show that while medical pre-training is beneficial, architectural choices (e.g., multi-scale) are critical, and pre-trained features are not universally effective, especially for complex localization tasks where supervised models remain a strong alternative.

cs.CV↗

Development of AI-integrated infrastructure with biomedical device and mobile app for neonatal vital monitoring during and in between kangaroo care sessions

Premature infant mortality remains a critical challenge in low- and middle-income countries (LMICs), with continuous vital sign monitoring being essential for early detection of life-threatening conditions. This paper presents an integrated system combining NeoWarm, a novel biomedical device, with NeoRoo, a mobile application, and NeoSmartML, a machine learning infrastructure, to enable comprehensive vital sign monitoring during Kangaroo Mother Care (KMC). Our power-optimized device achieves 6-6.5 days of continuous operation on a single charge, while the mobile application implements an offline-first architecture with efficient data synchronization. The optical character recognition pipeline demonstrates promising accuracy (F1 scores 0.78-0.875) for automated vital sign extraction from existing NICU monitors. Experimental validation shows the system's feasibility for deployment in resource-constrained settings, though further optimization of heart rate and temperature detection, along with the risk classification foundation model is needed.

eess.SP↗

Evaluating Vision Language Models (VLMs) for Radiology: A Comprehensive Analysis

Foundation models, trained on vast amounts of data using self-supervised techniques, have emerged as a promising frontier for advancing artificial intelligence (AI) applications in medicine. This study evaluates three different vision-language foundation models (RAD-DINO, CheXagent, and BiomedCLIP) on their ability to capture fine-grained imaging features for radiology tasks. The models were assessed across classification, segmentation, and regression tasks for pneumothorax and cardiomegaly on chest radiographs. Self-supervised RAD-DINO consistently excelled in segmentation tasks, while text-supervised CheXagent demonstrated superior classification performance. BiomedCLIP showed inconsistent performance across tasks. A custom segmentation model that integrates global and local features substantially improved performance for all foundation models, particularly for challenging pneumothorax segmentation. The findings highlight that pre-training methodology significantly influences model performance on specific downstream tasks. For fine-grained segmentation tasks, models trained without text supervision performed better, while text-supervised models offered advantages in classification and interpretability. These insights provide guidance for selecting foundation models based on specific clinical applications in radiology.

cs.CV↗

Synthetically Enhanced: Unveiling Synthetic Data's Potential in Medical Imaging Research

Chest X-rays (CXR) are essential for diagnosing a variety of conditions, but when used on new populations, model generalizability issues limit their efficacy. Generative AI, particularly denoising diffusion probabilistic models (DDPMs), offers a promising approach to generating synthetic images, enhancing dataset diversity. This study investigates the impact of synthetic data supplementation on the performance and generalizability of medical imaging research. The study employed DDPMs to create synthetic CXRs conditioned on demographic and pathological characteristics from the CheXpert dataset. These synthetic images were used to supplement training datasets for pathology classifiers, with the aim of improving their performance. The evaluation involved three datasets (CheXpert, MIMIC-CXR, and Emory Chest X-ray) and various experiments, including supplementing real data with synthetic data, training with purely synthetic data, and mixing synthetic data with external datasets. Performance was assessed using the area under the receiver operating curve (AUROC). Adding synthetic data to real datasets resulted in a notable increase in AUROC values (up to 0.02 in internal and external test sets with 1000% supplementation, p-value less than 0.01 in all instances). When classifiers were trained exclusively on synthetic data, they achieved performance levels comparable to those trained on real data with 200%-300% data supplementation. The combination of real and synthetic data from different sources demonstrated enhanced model generalizability, increasing model AUROC from 0.76 to 0.80 on the internal test set (p-value less than 0.01). In conclusion, synthetic data supplementation significantly improves the performance and generalizability of pathology classifiers in medical imaging.

cs.CV↗

DengueNet: Dengue Prediction using Spatiotemporal Satellite Imagery for Resource-Limited Countries

Dengue fever presents a substantial challenge in developing countries where sanitation infrastructure is inadequate. The absence of comprehensive healthcare systems exacerbates the severity of dengue infections, potentially leading to life-threatening circumstances. Rapid response to dengue outbreaks is also challenging due to limited information exchange and integration. While timely dengue outbreak forecasts have the potential to prevent such outbreaks, the majority of dengue prediction studies have predominantly relied on data that impose significant burdens on individual countries for collection. In this study, our aim is to improve health equity in resource-constrained countries by exploring the effectiveness of high-resolution satellite imagery as a nontraditional and readily accessible data source. By leveraging the wealth of publicly available and easily obtainable satellite imagery, we present a scalable satellite extraction framework based on Sentinel Hub, a cloud-based computing platform. Furthermore, we introduce DengueNet, an innovative architecture that combines Vision Transformer, Radiomics, and Long Short-term Memory to extract and integrate spatiotemporal features from satellite images. This enables dengue predictions on an epi-week basis. To evaluate the effectiveness of our proposed method, we conducted experiments on five municipalities in Colombia. We utilized a dataset comprising 780 high-resolution Sentinel-2 satellite images for training and evaluation. The performance of DengueNet was assessed using the mean absolute error (MAE) metric. Across the five municipalities, DengueNet achieved an average MAE of 43.92. Our findings strongly support the efficacy of satellite imagery as a valuable resource for dengue prediction, particularly in informing public health policies within countries where manually collected data is scarce and dengue virus prevalence is severe.

cs.CV↗

Healthcare Security Breaches in the United States: Insights and their Socio-Technical Implications

This research examines the pivotal role of human behavior in the realm of healthcare data management, situated at the confluence of technological advancements and human conduct. An in-depth analysis of security breaches in the United States from 2009 to the present elucidates the dominance of human-induced security breaches. While technological weak points are certainly a concern, our study highlights that a significant proportion of breaches are precipitated by human errors and practices, thus pinpointing a conspicuous deficiency in training, awareness, and organizational architecture. In spite of stringent federal mandates, such as the Health Insurance Portability and Accountability Act (HIPAA) and the Health Information Technology for Economic and Clinical Health (HITECH) Act, breaches persist, emphasizing the indispensable role of human factors within this domain. Such oversights not only jeopardize patient data confidentiality but also undermine the foundational trust inherent in the healthcare infrastructure. By probing the socio-technical facets of healthcare security infringements, this article advocates for an integrated, dynamic, and holistic approach to healthcare data security. The findings underscore the imperative of augmenting technological defenses while concurrently elevating human conduct and institutional ethos, thereby cultivating a robust and impervious healthcare data management environment.

cs.CY↗

Evaluation of accessibility of open-source EHRs for visually impaired users

This study investigates the accessibility of open-source electronic health record (EHR) systems for individuals who are visually impaired or blind. Ensuring the accessibility of EHRs to visually impaired users is critical for the diversity, equity, and inclusion of all users. The study used a combination of automated and manual accessibility testing techniques like screen readers to evaluate the accessibility of three widely used open-source EHR systems. Our assessment focused on the performance of three popular screen readers, including JAWS (Windows), NVDA (Windows), and Apple VoiceOver (OSX). The evaluation revealed that although each of the three systems was partially accessible, there is room for improvement, particularly regarding keyboard navigation and screen reader compatibility. The study concludes with recommendations for making EHR systems more inclusive for all users and more accessible.

cs.HC↗

A general-purpose AI assistant embedded in an open-source radiology information system

Radiology AI models have made significant progress in near-human performance or surpassing it. However, AI model's partnership with human radiologist remains an unexplored challenge due to the lack of health information standards, contextual and workflow differences, and data labeling variations. To overcome these challenges, we integrated an AI model service that uses DICOM standard SR annotations into the OHIF viewer in the open-source LibreHealth Radiology Information Systems (RIS). In this paper, we describe the novel Human-AI partnership capabilities of the platform, including few-shot learning and swarm learning approaches to retrain the AI models continuously. Building on the concept of machine teaching, we developed an active learning strategy within the RIS, so that the human radiologist can enable/disable AI annotations as well as "fix"/relabel the AI annotations. These annotations are then used to retrain the models. This helps establish a partnership between the radiologist user and a user-specific AI model. The weights of these user-specific models are then finally shared between multiple models in a swarm learning approach.

cs.AI↗

Few-Shot Transfer Learning to improve Chest X-Ray pathology detection using limited triplets

Deep learning approaches applied to medical imaging have reached near-human or better-than-human performance on many diagnostic tasks. For instance, the CheXpert competition on detecting pathologies in chest x-rays has shown excellent multi-class classification performance. However, training and validating deep learning models require extensive collections of images and still produce false inferences, as identified by a human-in-the-loop. In this paper, we introduce a practical approach to improve the predictions of a pre-trained model through Few-Shot Learning (FSL). After training and validating a model, a small number of false inference images are collected to retrain the model using \textbf{\textit{Image Triplets}} - a false positive or false negative, a true positive, and a true negative. The retrained FSL model produces considerable gains in performance with only a few epochs and few images. In addition, FSL opens rapid retraining opportunities for human-in-the-loop systems, where a radiologist can relabel false inferences, and the model can be quickly retrained. We compare our retrained model performance with existing FSL approaches in medical imaging that train and evaluate models at once.

eess.IV↗

OSCARS: An Outlier-Sensitive Content-Based Radiography Retrieval System

Improving the retrieval relevance on noisy datasets is an emerging need for the curation of a large-scale clean dataset in the medical domain. While existing methods can be applied for class-wise retrieval (aka. inter-class), they cannot distinguish the granularity of likeness within the same class (aka. intra-class). The problem is exacerbated on medical external datasets, where noisy samples of the same class are treated equally during training. Our goal is to identify both intra/inter-class similarities for fine-grained retrieval. To achieve this, we propose an Outlier-Sensitive Content-based rAdiologhy Retrieval System (OSCARS), consisting of two steps. First, we train an outlier detector on a clean internal dataset in an unsupervised manner. Then we use the trained detector to generate the anomaly scores on the external dataset, whose distribution will be used to bin intra-class variations. Second, we propose a quadruplet (a, p, nintra, ninter) sampling strategy, where intra-class negatives nintra are sampled from bins of the same class other than the bin anchor a belongs to, while niner are randomly sampled from inter-classes. We suggest a weighted metric learning objective to balance the intra and inter-class feature learning. We experimented on two representative public radiography datasets. Experiments show the effectiveness of our approach. The training and evaluation code can be found in https://github.com/XiaoyuanGuo/oscars.

cs.CV↗

CVAD: A generic medical anomaly detector based on Cascade VAE

Detecting out-of-distribution (OOD) samples in medical imaging plays an important role for downstream medical diagnosis. However, existing OOD detectors are demonstrated on natural images composed of inter-classes and have difficulty generalizing to medical images. The key issue is the granularity of OOD data in the medical domain, where intra-class OOD samples are predominant. We focus on the generalizability of OOD detection for medical images and propose a self-supervised Cascade Variational autoencoder-based Anomaly Detector (CVAD). We use a variational autoencoders' cascade architecture, which combines latent representation at multiple scales, before being fed to a discriminator to distinguish the OOD data from the in-distribution (ID) data. Finally, both the reconstruction error and the OOD probability predicted by the binary discriminator are used to determine the anomalies. We compare the performance with the state-of-the-art deep learning models to demonstrate our model's efficacy on various open-access medical imaging datasets for both intra- and inter-class OOD. Further extensive results on datasets including common natural datasets show our model's effectiveness and generalizability. The code is available at https://github.com/XiaoyuanGuo/CVAD.

eess.IV↗

Margin-Aware Intra-Class Novelty Identification for Medical Images

Traditional anomaly detection methods focus on detecting inter-class variations while medical image novelty identification is inherently an intra-class detection problem. For example, a machine learning model trained with normal chest X-ray and common lung abnormalities, is expected to discover and flag idiopathic pulmonary fibrosis which a rare lung disease and unseen by the model during training. The nuances from intra-class variations and lack of relevant training data in medical image analysis pose great challenges for existing anomaly detection methods. To tackle the challenges, we propose a hybrid model - Transformation-based Embedding learning for Novelty Detection (TEND) which without any out-of-distribution training data, performs novelty identification by combining both autoencoder-based and classifier-based method. With a pre-trained autoencoder as image feature extractor, TEND learns to discriminate the feature embeddings of in-distribution data from the transformed counterparts as fake out-of-distribution inputs. To enhance the separation, a distance objective is optimized to enforce a margin between the two classes. Extensive experimental results on both natural image datasets and medical image datasets are presented and our method out-performs state-of-the-art approaches.

cs.CV↗