arXiv ScienceSearch

arXiv subjects

Sandy Croatto

Publications and source records attributed to Sandy Croatto.

5 recordsLinked to original sources

A centimeter-sized gas pressure sensor for high-vacuum measurements at cryogenic temperatures

Gas pressure sensors based on nanomechanical membranes have recently demonstrated an ultra-wide ten-decade measurement range, a gas-type-independent response, and a self-calibrating operation with uncertainties of approximately $1\,\%$. The readout relied on tabletop free-space laser interferometers. Here we present a centimeter-sized, portable implementation in which a square Si$_3$N$_4$ membrane is read out via a fiber-based laser interferometer. We perform pressure measurements between $5\times10^{-5}$ and $10^{-1}$~mbar in a confined $0.7$~L volume cooled to $78$~K. Because no suitable commercial pressure sensor exists for direct cryogenic comparison, we benchmark our device against room-temperature commercial gauges connected to the cold volume through a pipe of limited conductance. The measured relationship between the two sensors is compared with models accounting for temperature- and pumping-induced pressure gradients within the measurement chamber. These models agree with the measurements to within $<10\,\%$ for helium and $<13\,\%$ for nitrogen. The achieved readout sensitivity of $S_x = 8\times10^{-14}\,\mathrm{m}/\sqrt{\mathrm{Hz}}$ theoretically enables resolving the thermal displacement noise spectrum of a trampoline membrane at atmospheric pressure, with a peak response of $48\,S_x$ $\left(25\,S_x\right)$ at $295\,\mathrm{K}$ $\left(78\,\mathrm{K}\right)$. Our results suggest that the previously achieved pressure measurement range of ten decades with trampoline membranes is compatible with fiber-based optical readout. This paves the way for widely applicable pressure sensors in the centimeter size range in cryogenic environments.

physics.app-ph

Any Light Particle Searches with ALPS II: first science results

The light-shining-through-a-wall experiment ALPS II at DESY in Hamburg searched for axions and similar lightweight particles in its first science campaign from February to May 2024. No evidence for the existence of such particles was found. For pseudoscalar bosons like the axion, with masses below about 0.1 meV, we achieved a limit for the di-photon coupling strength of 1.5e-9 1/GeV at a 95% confidence level. This is more than a factor of 20 improvement compared to all previous similar experiments. We also provide limits on photon interactions for scalar, vector and tensor bosons. An achievement of this first science campaign is the demonstration of stable operation and robust calibration of the complex experiment. Currently, the optical system of ALPS II is being upgraded aiming for another two orders of magnitude sensitivity increase.

hep-ex

Distributed Acoustic Fiber Sensing for Research Campuses and Large Scientific Infrastructures -- The Hamburg WAVE proto-network

Here, we demonstrate and investigate how Distributed Acoustic Sensing (DAS) can be utilized on research campuses and in large scientific infrastructures to study environmental vibrations and reduce their impact on high-precision experiments. We first discuss the potential of DAS in the context of particle accelerators, gravitational wave detection experiments and research campuses. Next, we present the results of our seismic measurement campaign conducted with our proto-network, which involved the probing of over 12 km of fiber, in May 2021. This campaign was conducted by the Hamburg WAVE initiative in Science City Hamburg Bahrenfeld and included DESY, the European XFEL, PETRA III and the University of Hamburg. Our proto-network confirms the ability to observe natural, anthropogenic, and infrastructural vibrations and how and where these couple into different parts of the heterogeneously set up fiber network. We also present results on a study of noise and motion coupling aspects of DAS probing double-redundant fiber loops in a unique environment, the European XFEL. Our results show that DAS greatly benefits research campuses and large scientific infrastructures and they highlight the opportunities and challenges of implementing and operating such seismic networks.

physics.ins-det

Measurement of the thermal accommodation coefficient of helium on a crystalline silicon surface at low-temperatures

Next-generation gravitational wave observatories are expected to use cryogenically cooled, pendulum-suspended 200 kg test mass mirrors from a crystalline material such as crystalline silicon. During operation of the observatories, these mirrors undergo heating due to the absorption of laser radiation of up to a watt. Low noise cooling techniques need to be developed. Low-pressure helium exchange gas at 5 K might contribute to the challenging task. Here, we report the measurement of the helium accommodation coefficient $\alpha(11\,\mathrm{K} 0.7$ for temperatures < 20 K, which increases the cooling power compared to recently used assumptions. The idea of free molecular flow helium gas cooling is thus supported and might find application in some observatory concepts.

physics.ins-det

Self-calibrating gas pressure sensor with a 10-decade measurement range

Recent years have seen a rapid reduction in the intrinsic loss of nanomechanical resonators (i.e., chip-scale mechanical oscillators). As a result, these devices become increasingly sensitive to the friction exerted by smallest amounts of gas. Here, we present the pressure-dependency of a nanomechanical trampoline resonator's quality factor $Q$ over ten decades, from $10^{-7}$ to $10^{3}\,\mathrm{mbar}$. We find that the measured behavior is well-described by a model combining analytical and numerical components for molecular and viscous flow, respectively. This model relies exclusively on design and typical material parameters, together with measured values of intrinsic resonance frequency $f_\mathrm{in}$ and quality factor $Q_\mathrm{in}$. Measuring $f_\mathrm{in}$ and $Q_\mathrm{in}$ at a pressure $<\!10^{-7}\,\mathrm{mbar}$ self-calibrates our sensor over its entire measurement range. For a trampoline's fundamental out-of-plane vibrational mode, the resulting deviation between measured and simulated pressure dependencies of the quality factor and resonance frequency is within $15\,\%$ and $4\,\%$, respectively. The resulting error for pressure values inferred from quality factor and frequency measurements is $<10\,\%$, for pressures between $\sim 10^{-6}$ and $\sim 10^{-1}\,\mathrm{mbar}$, and $<25\,\%$ for the complete 10-decade measurement range. Exceptions are two outliers with increased measurement errors, which might be related to the limited accuracy of our commercial pressure gauge. Based on investigations with helium, we demonstrate the potential for extending this sensing capability to other gases, thereby highlighting the practical use of our sensor.

physics.app-ph