arXiv ScienceSearch

arXiv subjects

Sam Cooper

Publications and source records attributed to Sam Cooper.

9 recordsLinked to original sources

On Being Prepared: Automated Vehicle Incident Management Exercise Practices

Incident management (IM) has evolved over recent decades to cover an ever-expanding array of hazards and systems. Barring real-life experience, exercises are a key tool in developing an effective IM program. As part of enterprise resilience and operational readiness, IM practitioners design exercises to understand and build capabilities for efficiently and effectively responding to incidents. Combining research and policy on an emerging transportation technology, automated vehicles (AVs), with established practices for IM, we describe what makes exercises effective and how they can be used to identify gaps and develop capacity. A range of exercise types exist, from workshops, to tabletops, to drills, and to full-scale exercises. Every stage of an exercise - preparing, setting up, facilitating, closing, and assessing - is interconnected and should further the exercise's objectives. AV IM practitioners can maximize the utility of a mature exercise program through exercise quality, diversity, and volume. The need to respond to AV incidents, from collisions to natural hazards, is inevitable. This paper tailors existing practices to a series of frameworks, predicated on the unique socio-technical nature of AVs to provide first-of-its-kind guidance for AV IM exercises. Additionally, these frameworks are company-neutral to enable intercompany and inter-organization collaboration.

cs.CY

Benchmarking and optimizing organism wide single-cell RNA alignment methods

Many methods have been proposed for removing batch effects and aligning single-cell RNA (scRNA) datasets. However, performance is typically evaluated based on multiple parameters and few datasets, creating challenges in assessing which method is best for aligning data at scale. Here, we introduce the K-Neighbors Intersection (KNI) score, a single score that both penalizes batch effects and measures accuracy at cross-dataset cell-type label prediction alongside carefully curated small (scMARK) and large (scREF) benchmarks comprising 11 and 46 human scRNA studies respectively, where we have standardized author labels. Using the KNI score, we evaluate and optimize approaches for cross-dataset single-cell RNA integration. We introduce Batch Adversarial single-cell Variational Inference (BA-scVI), as a new variant of scVI that uses adversarial training to penalize batch-effects in the encoder and decoder, and show this approach outperforms other methods. In the resulting aligned space, we find that the granularity of cell-type groupings is conserved, supporting the notion that whole-organism cell-type maps can be created by a single model without loss of information.

cs.LG

Design and sensitivity of a 6-axis seismometer for gravitational wave observatories

We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fibre. We utilise custom-made, compact Michelson interferometers for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom. We develop the sensor for gravitational-wave observatories, such as LIGO, Virgo, and KAGRA, to help them observe intermediate-mass black holes, increase their duty cycle, and improve localisation of sources. Our control system and its achieved sensitivity makes the sensor suitable for other fundamental physics experiments, such as tests of semiclassical gravity, searches for bosonic dark matter, and studies of the Casimir force.

physics.ins-det

Active platform stabilisation with a 6D seismometer

We demonstrate the control scheme of an active platform with a six degree of freedom (6D) seismometer. The inertial sensor simultaneously measures translational and tilt degrees of freedom of the platform and does not require any additional sensors for the stabilisation. We show that a feedforward cancellation scheme can efficiently decouple tilt-to-horizontal coupling of the seismometer in the digital control scheme. We stabilise the platform in the frequency band from 250 mHz up to 10 Hz in the horizontal degrees of freedom and achieve a suppression factor of 100 around 1 Hz. Further suppression of ground vibrations was limited by the non-linear response of the piezo actuators of the platform and by its limited range (5 {\mu}m). In this paper we discuss the 6D seismometer, its control scheme, and the limitations of the test bed.

astro-ph.IM

Compact Michelson interferometers with subpicometer sensitivity

The network of interferometric gravitational-wave observatories has successfully detected tens of astrophysical signals since 2015. In this paper, we experimentally investigate compact sensors that have the potential to improve the sensitivity of gravitational-wave detectors to intermediate-mass black holes. We use only commercial components, such as sensing heads and lasers, to assemble the setup and demonstrate its subpicometer precision. The setup consists of a pair of Michelson interferferometers that use deep frequency modulation techniques to obtain a linear, relative displacement readout over multiple interference fringes. We implement a laser-frequency stabilisation scheme to achieve a sensitivity of 0.3\,$\text{pm} / \sqrt{\text{Hz}}$ above 0.1\,Hz. The device has also the potential to improve other experiments, such as torsion balances and commercial seismometers.

physics.ins-det

A six degree-of-freedom fused silica seismometer: Design and tests of a metal prototype

Ground vibrations couple to the longitudinal and angular motion of the aLIGO test masses and limit the observatory sensitivity below 30\,Hz. Novel inertial sensors have the potential to improve the aLIGO sensitivity in this band and simplify the lock acquisition of the detectors. In this paper, we experimentally study a compact 6D seismometer that consists of a mass suspended by a single wire. The position of the mass is interferometrically read out relative to the platform that supports the seismometer. We present the experimental results, discuss limitations of our metallic prototype, and show that a compact 6D seismometer made out of fused silica and suspended with a fused silica fibre has the potential to improve the aLIGO low frequency noise.

physics.ins-det

Towards windproofing LIGO: Reducing the effect of wind-driven floor tilt by using rotation sensors in active seismic isolation

Modern gravitational-wave observatories require robust low-frequency active seismic isolation in order to keep the interferometer at its ideal operating conditions. Seismometers are used to measure both the motion of the ground and isolated platform. These devices are susceptible to contamination from ground tilt at frequencies below 0.1 Hz, particularly arising from wind-pressure acting on building walls. Consequently, during LIGO's first observing run both observatories suffered significant downtime when wind-speeds were above 7 m/s. We describe the use of ground rotation sensors at the LIGO Hanford Observatory to correct nearby ground seismometers to produce tilt-free ground translation signals. The use of these signals for sensor correction control improved low-frequency seismic isolation and allowed the observatory to operate under wind speeds as high as $15-20$ m/s.

physics.ins-det

A Cryogenic Silicon Interferometer for Gravitational-wave Detection

The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor.

astro-ph.IM

A Review of Compact Interferometers

Compact interferometers, called phasemeters, make it possible to operate over a large range while ensuring a high resolution. Such performance is required for the stabilization of large instruments dedicated to experimental physics such as gravitational wave detectors. This paper aims at presenting the working principle of the different types of phasemeters developed in the literature. These devices can be classified into two categories: homodyne and heterodyne interferometers. Improvement of resolution and accuracy has been studied for both devices. Resolution is related to the noise sources that are added to the signal. Accuracy corresponds to distortion of the phase measured with respect to the real phase, called non-linearity. The solutions proposed to improve the device resolution and accuracy are discussed based on a comparison of the reached resolutions and of the residual non-linearities.

astro-ph.IM