arXiv ScienceSearch

arXiv subjects

S. Masuda

Publications and source records attributed to S. Masuda.

At least 19 recordsLinked to original sources

First results from the search for an excess of $\bar{\nu}_{e}$ events in JSNS$^2$

The JSNS$^2$ (J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source) experiment at the Material and Life Science Facility (MLF) of J-PARC is designed to directly test an excess on $\bar{\nu}_{e}$ events which was indicated by LSND (Liquid Scintillator Neutrino Detector). The combination of a short-pulsed proton beam and a gadolinium-loaded liquid scintillator provides an excellent signal-to-noise ratio. In this article, we report the first results of a direct test based on data collected in 2022. After applying all event selection criteria, two events are observed, consistent with the expected background of 2.3$\pm$0.4 events. No excess of $\bar{\nu}_e$ events are seen in this report, however the expected number of events due to LSND anomaly is 1.1$\pm$0.5, thus this result is not yet conclusive. Data taking has been ongoing since 2021 and will continue in future runs. In addition, a new far detector has recently been constructed for the second phase experiment, JSNS$^2$-II, marking an important milestone toward forthcoming measurements.

hep-ex

Quantum annealing in capacitively coupled Kerr parametric oscillators using frequency-chirped drives

We study parametric oscillations of two capacitively coupled Kerr parametric oscillators (KPOs) with frequency-chirped two- and one-photon drives. The two-KPO system adiabatically evolves from the initial vacuum state to an oscillation state corresponding to a solution state in quantum-annealing applications. Frequency chirping dynamically changes the detuning between resonance and oscillation frequencies during parametric modulation and reduces unwanted population transfer to excited states caused by pure dephasing and photon loss. We observe that frequency chirping increases the success probability to obtain the solution state and that simulations taking into account pure dephasing reproduce experiments with and without frequency chirping. This study demonstrates the effectiveness and applicability of frequency chirping to a KPO-based quantum annealer.

quant-ph

PMT calibration for the JSNS2-II far detector with an embedded LED system

The JSNS2-II (the second phase of JSNS2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. This experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. The properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector, such as gain, its dependence of supplied High Voltage (HV), and Peak-to-Valley (PV) were calibrated. To achieve a good energy resolution for physics events, up to 10% of the relative gain adjustment is required for all functioning PMTs. This will be achieved using the measured HV curves and the LED calibration. The Peak-to-Valley (PV) ratio values are the similar to those from the production company, which distinguish the single photo-electron signal from the pedestal. Additionally, the precision of PMT signal timing is measured to be 2.1 ns, meeting the event reconstruction requirement of 10 ns.

physics.ins-det

Muon tagging with Flash ADC waveform baselines

This manuscript describes an innovative method to tag the muons using the baseline information of the Flash ADC (FADC) waveform of PMTs in the JSNS1 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment. This experiment is designed for the search for sterile neutrinos, and a muon tagging is an essential key component for the background rejection since the detector of the experiment is located over-ground, where is the 3rd floor of the J-PARC Material and Life experimental facility (MLF). Especially, stopping muons inside the detector create the Michel electrons, and they are important background to be rejected. Utilizing this innovative method, more than 99.8% of Michel electrons can be rejected even without a detector veto region. This technique can be employed for any experiments which uses the similar detector configurations.

physics.ins-det

Development and Quality Control of PMT Modules for the Large-Sized Telescopes of the Cherenkov Telescope Array Observatory

The camera of the Large-Sized Telescopes (LSTs) of the Cherenkov Telescope Array Observatory (CTAO) consists of 1855 pixels that are grouped into 265 high-performance photomultiplier tube (PMT) modules. Each module comprises a seven-light-guide plate, seven PMT units, a slow control board, and a readout board with a trigger board. %In this paper we describe The requirements for the PMT modules include various aspects, such as photon detection efficiency, dynamic range, buffer depth, and test pulse functionality. We have developed a high-performance PMT module that fulfills all these requirements. Mass-production and quality control (QC) of modules for all four LSTs of the northern CTAO have been completed. Here we report on the technical details of each element of the module and its performance, together with the methods and results of QC measurements.

astro-ph.IM

The first JSNS$^2$ measurement of electron neutrino flux using $^{12}C(\nu_{e},e^{-}) ^{12}N_{g.s.}$ reaction

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment searching for sterile neutrinos through the observation of $\bar{\nu}_{\mu} \rightarrow \bar{\nu}_e$ appearance oscillations, using neutrinos produced by muon decay-at-rest. A key aspect of the experiment involves accurately understanding the neutrino flux and the quantities of pions and muons, which are progenitors of (anti-)neutrinos, given that their production rates have yet to be measured. We present the first electron-neutrino flux measurement using $^{12}\mathrm{C}(\nu_{e},e^{-}) ^{12}\mathrm{N}_{g.s.}$ reaction in JSNS$^2$, yielding a flux of (6.7 $\pm$ 1.6 (stat.) $\pm$ 1.7 (syst.)) $\times$ 10$^{-9}$ cm$^{-2}$ proton$^{-1}$ at the JSNS$^2$ detector location, located at 24 meters distance from the mercury target. This flux measurement is consistent with predictions from simulations based on hadron models.

hep-ex

First Measurement of Missing Energy Due to Nuclear Effects in Monoenergetic Neutrino Charged Current Interactions

We present the first measurement of the missing energy due to nuclear effects in monoenergetic, muon neutrino charged-current interactions on carbon, originating from $K^+ \rightarrow \mu^+ \nu_\mu$ decay at rest ($E_{\nu_\mu}=235.5$ MeV), performed with the J-PARC Sterile Neutrino Search at the J-PARC Spallation Neutron Source liquid scintillator based experiment. Toward characterizing the neutrino interaction, ostensibly $\nu_\mu n \rightarrow \mu^- p$ or $\nu_\mu$$^{12}\mathrm{C}$ $\rightarrow \mu^-$$^{12}\mathrm{N}$, we define the missing energy as the energy transferred to the nucleus ($\omega$) minus the kinetic energy of the outgoing proton(s), $E_{m} \equiv\omega-\sum T_p$, and relate this to visible energy in the detector, $E_{m}=E_{\nu_\mu} (235.5 \mathrm{MeV})-m_\mu (105.7 \mathrm{MeV}) + [m_n-m_p (1.3 \mathrm{MeV})] - E_{\mathrm{vis}}$. The missing energy, which is naively expected to be zero in the absence of nuclear effects (e.g. nucleon separation energy, Fermi momenta, and final-state interactions), is uniquely sensitive to many aspects of the interaction, and has previously been inaccessible with neutrinos. The shape-only, differential cross section measurement reported, based on a $(77\pm3)$% pure double-coincidence kaon decay-at-rest signal (621 total events), provides detailed insight into neutrino-nucleus interactions, allowing even the nuclear orbital shell of the struck nucleon to be inferred. The measurement provides an important benchmark for models and event generators at hundreds of MeV neutrino energies, characterized by the difficult-to-model transition region between neutrino-nucleus and neutrino-nucleon scattering, and relevant for applications in nuclear physics, neutrino oscillation measurements,and Type-II supernova studies.

hep-ex

Evaluation of the performance of the event reconstruction algorithms in the JSNS$^2$ experiment using a $^{252}$Cf calibration source

JSNS$^2$ searches for short baseline neutrino oscillations with a baseline of 24~meters and a target of 17~tonnes of the Gd-loaded liquid scintillator. The correct algorithm on the event reconstruction of events, which determines the position and energy of neutrino interactions in the detector, are essential for the physics analysis of the data from the experiment. Therefore, the performance of the event reconstruction is carefully checked with calibrations using $^{252}$Cf source. This manuscript describes the methodology and the performance of the event reconstruction.

hep-ex

Pulse Shape Discrimination in JSNS$^2$

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \rightarrow \bar{\nu}_e$ appearance oscillations using neutrinos with muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS$^2$ detector is located above ground, on the third floor of the building. We have achieved 95$\%$ rejection of neutron events while keeping 90$\%$ of signal, electron-like events using a data driven likelihood method.

physics.ins-det

The acrylic vessel for JSNS$^{2}$-II neutrino target

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment designed for the search for sterile neutrinos. The experiment is currently at the stage of the second phase named JSNS$^{2}$-II with two detectors at near and far locations from the neutrino source. One of the key components of the experiment is an acrylic vessel, that is used for the target volume for the detection of the anti-neutrinos. The specifications, design, and measured properties of the acrylic vessel are described.

hep-ex

Study on the accidental background of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment which searches for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \to \bar{\nu}_{e}$ appearance oscillations using muon decay-at-rest neutrinos. The data taking of JSNS$^2$ have been performed from 2021. In this manuscript, a study of the accidental background is presented. The rate of the accidental background is (9.29$\pm 0.39) \times 10^{-8}$ / spill with 0.75 MW beam power and comparable to the number of searching signals.

hep-ex

Correlated oscillations in Kerr parametric oscillators with tunable effective coupling

We study simultaneous parametric oscillations in a system composed of two distributed-element-circuit Josephson parametric oscillators in the single-photon Kerr regime coupled via a static capacitance. The energy of the system is described by a two-bit Ising Hamiltonian with an effective coupling whose amplitude and sign depend on the relative phase between parametric pumps. We demonstrate that the binary phases of the parametric oscillations are correlated with each other, and that the parity and strength of the correlation can be controlled by adjusting the pump phase. The observed correlation is reproduced in our simulation taking pure dephasing into account. The present result demonstrates the tunability of the Hamiltonian parameters by the phase of external microwave, which can be used in the Ising machine hardware composed of the KPO network.

quant-ph

Proton Penetration Efficiency over a High Altitude Observatory in Mexico

In association with a large solar flare on November 7, 2004, the solar neutron detectors located at Mt. Chacaltaya (5,250m) in Bolivia and Mt. Sierra Negra (4,600m) in Mexico recorded very interesting events. In order to explain these events, we have performed a calculation solving the equation of motion of anti-protons inside the magnetosphere. Based on these results, the Mt. Chacaltaya event may be explained by the detection of solar neutrons, while the Mt. Sierra Negra event may be explained by the first detection of very high energy solar neutron decay protons (SNDPs) around 6 GeV.

astro-ph.SR

Characterization of the correlated background for a sterile neutrino search using the first dataset of the JSNS$^2$ experiment

JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\bar{\nu}_{\mu} \to \bar{\nu}_{e}$ appearance oscillations using muon decay-at-rest neutrinos. Before dedicated data taking in the first-half of 2021, we performed a commissioning run for 10 days in June 2020. Using the data obtained in this commissioning run, in this paper, we present an estimate of the correlated background which imitates the $\bar{\nu}_{e}$ signal in a sterile neutrino search. In addition, in order to demonstrate future prospects of the JSNS$^2$ experiment, possible pulse shape discrimination improvements towards reducing cosmic ray induced fast neutron background are described.

hep-ex

Theoretical study of reflection spectroscopy for superconducting quantum parametrons

Superconducting parametrons in the single-photon Kerr regime, also called KPOs, have been attracting increasing attention in terms of their applications to quantum annealing and universal quantum computation. It is of practical importance to obtain information of superconducting parametrons operating under an oscillating pump field. Spectroscopy can provide information of a superconducting parametron under examination, such as energy level structure, and also useful information for calibration of the pump field. We theoretically study the reflection spectroscopy of superconducting parametrons, and develop a method to obtain the reflection coefficient. We present formulae of the reflection coefficient, the nominal external and the internal decay rates, and examine the obtained spectra. It is shown that the difference of the populations of energy levels manifests itself as a dip or peak in the amplitude of the reflection coefficient, and one can directly extract the coupling strength between the energy levels by measuring the nominal decay rates when the pump field is sufficiently large.

quant-ph

The JSNS^2 Detector

The JSNS^2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for oscillations involving a sterile neutrino in the eV^2 mass-splitting range. The experiment will search for the appearance of electron antineutrinos oscillated from muon antineutrinos. The electron antineutrinos are detected via the inverse beta decay process using a liquid scintillator detector. A 1MW beam of 3 GeV protons incident on a spallation neutron target produces an intense and pulsed neutrino source from pion, muon, and kaon decay at rest. The JSNS^2 detector is located 24 m away from the neutrino source and began operation from June 2020. The detector contains 17 tonnes of gadolinium (Gd) loaded liquid scintillator (LS) in an acrylic vessel, as a neutrino target. It is surrounded by 31 tonnes of unloaded LS in a stainless steel tank. Optical photons produced in LS are viewed by 120 R7081 Hamamatsu 10-inch Photomultiplier Tubes (PMTs). In this paper, we describe the JSNS^2 detector design, construction, and operation.

physics.ins-det

Study of the variable broadband emission of Markarian 501 during the most extreme Swift X-ray activity

Mrk501 is a very high-energy (VHE) gamma-ray blazar located at z=0.034. During a period of two weeks in July 2014, the highest X-ray activity of Mrk501 was observed in ~14 years of operation of the Neil Gehrels Swift Gamma-ray Burst Observatory. We characterize the broadband variability of Mrk501 from radio to VHE gamma rays, and evaluate whether it can be interpreted within theoretical scenarios widely used to explain the broadband emission from blazars. The temporal evolution of the most prominent and variable segments of the SED is described with a one-zone synchrotron self-Compton model with variations in the break energy of the electron energy distribution (EED), and with some adjustments in the magnetic field strength and spectral shape of the EED. A narrow feature at ~3 TeV was observed in the VHE spectrum measured on 2014 July 19 (MJD 56857.98), which is the day with the highest X-ray flux ($>0.3$ keV) measured during the entire Swift mission. This feature is inconsistent with the classical analytic functions to describe the measured VHE spectra (power law, log-parabola, and log-parabola with exponential cutoff) at more than 3$σ$. A fit with a log-parabola plus a narrow component is preferred over the fit with a single log-parabola at more than 4$σ$, and a dedicated Monte Carlo simulation estimated the significance of this extra component to be larger than 3$σ$. Under the assumption that this VHE spectral feature is real, we show that it can be reproduced with three distinct theoretical scenarios: a) a pileup in the EED due to stochastic acceleration; b) a structured jet with two-SSC emitting regions, with one region dominated by an extremely narrow EED; and c) an emission from an IC pair cascade.

astro-ph.HE

Proposal: JSNS$^2$-II

This article describes the goal and expected sensitivity of the JSNS$^2$-II experiment at J-PARC Materials and Life Science Experimental Facility (MLF). The JSNS$^2$-II experiment is the second phase of the JSNS$^2$ experiment (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) with two detectors which are located in 24 m (an existing detector) and 48 m (new one) baselines to improve the sensitivity of the search for sterile neutrinos, especially in the low $Δm^2$ region, which has been indicated by the global fit of the appearance mode. The new second detector has a similar structure as the existing JSNS$^2$ detector, which is already working. To compensate for the reduction of the neutrino flux due to the distance from the mercury target, the target mass of the Gd-loaded liquid scintillator which is the Linear AlkylBenzene (LAB) based liquid scintillator inside the acrylic vessel is 35 tons. To keep the same photo-coverage of the detector as the first detector, we will surround the acrylic vessel with 240 PMTs. With this experimental setup and 5 years (times 1 MW beam power) exposure, the sensitivity of the JSNS$^2$-II is significantly improved compared to the current JSNS$^2$, especially in the low $Δm^2$ oscillation parameter region. The JSNS$^2$-II can also confirm or refute the most of the oscillation parameters' space preferred by the previous experiments with 3 sigma C.L.. Considering these situations and world wide status of the sterile neutrino searches, we are eager to start the data taking with the two detector configuration from 2023. The fund to build the second detector was already secured.

hep-ex