arXiv ScienceSearch

arXiv subjects

S. Cuen-Rochin

Publications and source records attributed to S. Cuen-Rochin.

16 recordsLinked to original sources

Assembly, testing, and installation of mPMT photosensor for the Water Cherenkov Test Experiment

The multi-Photomultiplier Tube (mPMT) photosensors will be used in the Water Cherenkov Test Experiment (WCTE) to efficiently detect the photons produced in the whole detector. One of the aims behind the development of WCTE is to test the technology and implement it in future water Cherenkov experiments such as the Hyper-Kamiokande experiment and its Intermediate Water Cherenkov Detector. Each mPMT is built using nineteen 3-inch PMTs arranged on a semi-spherical support matrix. In this paper, we describe the design and manufacture of the mechanical components, the procedures for casting an optical gel between PMTs and acrylic cover, and the overall assembly procedure of the mPMTs. Details of the electronics used in the mPMT modules are not included in this paper and will be presented in a separate publication. We also report on the R&D performed on the selection of the optical gel ratio along with transmittance measurements and the reflectance measurements performed on the aluminium reflector. We also present the optical tests performed on the mPMT module using a 405 nm LED and the resulting increase in the effective photosensitive area by surrounding the PMTs with a reflector. A summary of the production and installation of the mPMTs for the WCTE is also presented in this paper.

physics.ins-det

European Strategy for Particle Physics Update -- PIONEER: a next generation rare pion decay experiment

PIONEER is a rapidly developing effort aimed to perform a pristine test of lepton flavour universality (LFU) and of the unitarity of the first row of the CKM matrix by significantly improving the measurements of rare decays of the charged pion. In Phase I, PIONEER aims to measure the charged-pion branching ratio to electrons vs.\ muons $R_{e/\mu}$ to 1 part in $10^4$, improving the current experimental result $R_{e/\mu}\,\text{(exp)} =1.2327(23)\times10^{-4}$ by a factor of 15. This precision on $R_{e/\mu}$ will match the theoretical accuracy of the SM prediction allowing for a test of LFU at an unprecedented level, probing non-SM explanations of LFU violation through sensitivity to quantum effects of new particles up to the PeV mass scale. Phase II and III will aim to improve the experimental precision of the branching ratio of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, currently at $1.036(6)\times10^{-8}$, by a factor of three and six, respectively. The improved measurements will be used to extract $V_{ud}$ in a theoretically pristine manner. The ultimate precision of $V_{ud}$ is expected to reach the 0.05\,\% level, allowing for a stringent test of CKM unitarity. The PIONEER experiment will also improve the experimental limits by an order of magnitude or more on a host of exotic decays that probe the effects of heavy neutrinos and dark sector physics. This input to the 2026 update of the European Strategy for Particle Physics Strategy describes the physics motivation and the conceptual design of the PIONEER experiment, and is prepared based on the PIONEER proposal submitted to and approved with high priority by the PSI program advisory committee (PAC). Using intense pion beams, and state-of-the-art instrumentation and computational resources, the PIONEER experiment is aiming to begin data taking by the end of this decade.

hep-ex

Measurement of the response function of the PIENU calorimeter

Measurements of the response function of the PIENU NaI(T$\ell$) and CsI crystal calorimeter using a monochromatic 70 MeV/c positron beam at various incidence angles are described. The experimental setup and relevant physical processes involved were simulated using Geant4 to reproduce positron energy spectra. Monte Carlo simulations were compared with experimental data across ten calorimeter-beam angles and showed good agreement. This allowed the validation of simulation parameters that were essential for precise measurements of pion decays.

hep-ex

Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment

The physics motivation and the conceptual design of the PIONEER experiment, a next-generation rare pion decay experiment testing lepton flavor universality and CKM unitarity, are described. Phase I of the PIONEER experiment, which was proposed and approved at Paul Scherrer Institut, aims at measuring the charged-pion branching ratio to electrons vs.\ muons, $R_{e/\mu}$, 15 times more precisely than the current experimental result, reaching the precision of the Standard Model (SM) prediction at 1 part in $10^4$. Considering several inconsistencies between the SM predictions and data pointing towards the potential violation of lepton flavor universality, the PIONEER experiment will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles up to the PeV mass scale. The later phases of the PIONEER experiment aim at improving the experimental precision of the branching ratio of pion beta decay (BRPB), $\pi^+\to \pi^0 e^+ \nu (\gamma)$, currently at $1.036(6)\times10^{-8}$, by a factor of three (Phase II) and an order of magnitude (Phase III). Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of $|V_{ud}|$ at the 0.02\% level, comparable to the deduction from superallowed beta decays.

hep-ex

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

hep-ex

Search for three body pion decays ${\pi}^+{\to}l^+{\nu}X$

The three body pion decays ${\pi}^+{\rightarrow}l^+{\nu}X~(l=e,{\mu})$, where $X$ is a weakly interacting neutral boson, were searched for using the full data set from the PIENU experiment. An improved limit on ${\Gamma}({\pi}^+{\to}e^+{\nu}X)/{\Gamma}({\pi}^+{\to}{\mu}^+{\nu}_{\mu})$ in the mass range $0<m_X<120$ MeV/$c^2$ and a first result for ${\Gamma}({\pi}^+{\to}{\mu}^+{\nu}X)/{\Gamma}({\pi}^+{\to}{\mu}^+{\nu}_{\mu})$ in the region $0<m_X<33.9$ MeV/$c^2$ were obtained. The Majoron-neutrino coupling model was also constrained using the current experimental result of the ${\pi}^+{\to}e^+{\nu}_e({\gamma})$ branching ratio.

hep-ex

Supernova Model Discrimination with Hyper-Kamiokande

Core-collapse supernovae are among the most magnificent events in the observable universe. They produce many of the chemical elements necessary for life to exist and their remnants -- neutron stars and black holes -- are interesting astrophysical objects in their own right. However, despite millennia of observations and almost a century of astrophysical study, the explosion mechanism of core-collapse supernovae is not yet well understood. Hyper-Kamiokande is a next-generation neutrino detector that will be able to observe the neutrino flux from the next galactic core-collapse supernova in unprecedented detail. We focus on the first 500 ms of the neutrino burst, corresponding to the accretion phase, and use a newly-developed, high-precision supernova event generator to simulate Hyper-Kamiokande's response to five different supernova models. We show that Hyper-Kamiokande will be able to distinguish between these models with high accuracy for a supernova at a distance of up to 100 kpc. Once the next galactic supernova happens, this ability will be a powerful tool for guiding simulations towards a precise reproduction of the explosion mechanism observed in nature.

astro-ph.IM

The Hyper-Kamiokande Experiment -- Snowmass LOI

Hyper-Kamiokande is the next generation underground water Cherenkov detector that builds on the highly successful Super-Kamiokande experiment. The detector which has an 8.4~times larger effective volume than its predecessor will be located along the T2K neutrino beamline and utilize an upgraded J-PARC beam with 2.6~times beam power. Hyper-K's low energy threshold combined with the very large fiducial volume make the detector unique, that is expected to acquire an unprecedented exposure of 3.8~Mton$\cdot$year over a period of 20~years of operation. Hyper-Kamiokande combines an extremely diverse science program including nucleon decays, long-baseline neutrino oscillations, atmospheric neutrinos, and neutrinos from astrophysical origins. The scientific scope of this program is highly complementary to liquid-argon detectors for example in sensitivity to nucleon decay channels or supernova detection modes. Hyper-Kamiokande construction has started in early 2020 and the experiment is expected to start operations in 2027. The Hyper-Kamiokande collaboration is presently being formed amongst groups from 19 countries including the United States, whose community has a long history of making significant contributions to the neutrino physics program in Japan. US physicists have played leading roles in the Kamiokande, Super-Kamiokande, EGADS, K2K, and T2K programs.

physics.ins-det

Search for the rare decays $\pi^+ \to \mu^+\nu_\mu\nu\bar\nu$ and $\pi^+ \to e^+\nu_e\nu\bar\nu$

The rare pion decays ${\pi}^+{\rightarrow}{\mu}^+{\nu}_{\mu}{\nu}\bar{\nu}$ and ${\pi}^+{\rightarrow}e^+{\nu}_{e}{\nu}\bar{\nu}$ are allowed in the Standard Model but highly suppressed. These decays were searched for using data from the PIENU experiment. A first result for ${\Gamma}({\pi}^+{\rightarrow}{\mu}^+{\nu}_{\mu}{\nu}\bar{\nu})/{\Gamma}({\pi}^+{\rightarrow}{\mu}^+{\nu}_{\mu})<8.6{\times}10^{-6}$, and an improved measurement ${\Gamma}({\pi}^+{\rightarrow}{e}^+{\nu}_{e}{\nu}\bar{\nu})/{\Gamma}({\pi}^+{\rightarrow}{\mu}^+{\nu}_{\mu})<1.6{\times}10^{-7}$ were obtained.

hep-ex

Improved search for two body muon decay ${\mu}^+{\rightarrow}e^+X_H$

Charged lepton flavor violating muon decay ${\mu}^+{\rightarrow}e^+X_H$, where $X_H$ is a massive neutral boson, was sought by searching for extra peaks in the muon decay ${\mu}^+{\rightarrow}e^+{\nu}\bar{\nu}$ energy spectrum in the $m_{X_H}$ mass region $47.8-95.1$ MeV/$c^2$. No signal was found and 90% confidence level upper limits were set on the branching ratio ${\Gamma}({\mu}^+{\rightarrow}e^+X_H)/{\Gamma}({\mu}^+{\rightarrow}e^+{\nu}\bar{\nu})$ at the level of $10^{-5}$ for this region.

hep-ex

Search for Heavy Neutrinos in $\pi \to \mu\nu$ Decay

Heavy neutrinos were sought in pion decays $\pi^+ \rightarrow \mu^+ \nu$ by examining the observed muon energy spectrum for extra peaks in addition to the expected peak for a massless neutrino. No evidence for heavy neutrinos was observed. Upper limits were set on the neutrino mixing matrix $|U_{\mu i}|^2$ in the neutrino mass region of 15.7--33.8 MeV/c$^2$, improving on previous results by an order of magnitude.

hep-ex

Improved Search for Heavy Neutrinos in the Decay $\pi\rightarrow e\nu$

A search for massive neutrinos has been made in the decay $\pi\rightarrow e^+ \nu$. No evidence was found for extra peaks in the positron energy spectrum indicative of pion decays involving massive neutrinos ($\pi\rightarrow e^+ \nu_h$). Upper limits (90 \% C.L.) on the neutrino mixing matrix element $|U_{ei}|^2$ in the neutrino mass region 60--135 MeV/$c^2$ were set, which are %representing an order of magnitude improvement over previous results.

hep-ex

Status of the TRIUMF PIENU Experiment

The PIENU experiment at TRIUMF aims to measure the pion decay branching ratio $R={\Gamma}({\pi}^+{\rightarrow}e^+{\nu}_e({\gamma}))/{\Gamma}({\pi}^+{\rightarrow}{\mu}^+{\nu}_{\mu}({\gamma}))$ with precision $<0.1$% to provide a sensitive test of electron-muon universality in weak interactions. The current status of the PIENU experiment is presented.

physics.ins-det

Improved measurement of the $\pi \rightarrow \mbox{e} \nu$ branching ratio

A new measurement of the branching ratio, $R_{e/\mu} =\Gamma (\pi^+ \rightarrow \mbox{e}^+ \nu + \pi^+ \rightarrow \mbox{e}^+ \nu \gamma)/ \Gamma (\pi^+ \rightarrow \mu^+ \nu + \pi^+ \rightarrow \mu^+ \nu \gamma)$, resulted in $R_{e/\mu}^{exp} = (1.2344 \pm 0.0023 (stat) \pm 0.0019 (syst)) \times 10^{-4}$. This is in agreement with the standard model prediction and improves the test of electron-muon universality to the level of 0.1 %.

hep-ex

Detector for measuring the $\pi^+\to e^+\nu_e$ branching fraction

The PIENU experiment at TRIUMF is aimed at a measurement of the branching ratio $R^{e/\mu}$ = ${\Gamma\big((\pi^{+} \rightarrow e^{+} \nu_{e}) + (\pi^{+} \rightarrow e^{+} \nu_{e}\gamma)\big)}/{\Gamma\big((\pi^{+} \rightarrow \mu^{+} \nu_{\mu})+(\pi^{+} \rightarrow \mu^{+} \nu_{\mu}\gamma)\big)}$ with precision $<$0.1\%. Incident pions, delivered at the rate of 60 kHz with momentum 75 MeV/c, were degraded and stopped in a plastic scintillator target. Pions and their decay product positrons were detected with plastic scintillators and tracked with multiwire proportional chambers and silicon strip detectors. The energies of the positrons were measured in a spectrometer consisting of a large NaI(T$\ell$) crystal surrounded by an array of pure CsI crystals. This paper provides a description of the PIENU experimental apparatus and its performance in pursuit of $R^{e/\mu}$.

physics.ins-det