arXiv Science⌕ Search

arXiv subjects

Ryusei Okaniwa

Publications and source records attributed to Ryusei Okaniwa.

5 recordsLinked to original sources

Axis-selective AC magnetic-field imaging in the tens-of-megahertz regime using RF-dressed continuous-wave scanning NV magnetometry

Spatially resolved magnetic-field imaging reveals material properties and local currents in microelectronic devices. Conventional pulsed scanning nitrogen-vacancy (NV) magnetometry (SNVM) faces increasingly stringent microwave (MW) pulse-control requirements for detecting radio-frequency (RF) magnetic fields at frequencies ranging from tens to hundreds of megahertz. To address this challenge, we implement an RF-dressed continuous-wave (CW) sensing scheme for SNVM and demonstrate AC magnetic-field imaging at 33.5 MHz. The method exploits electron-spin double resonance in the NV spin-1 three-level system: the target RF magnetic field coherently couples two spin eigenstates, forming RF-dressed states whose splittings are detected in continuous-wave electron-spin double resonance (CW-ESDR) spectra under continuous laser, MW, and RF excitation. This approach avoids short, high-power MW pulses and synchronization between the RF field and a pulsed sensing sequence. Using an NV-ensemble diamond probe integrated with an atomic force microscope (AFM), we image the Oersted field of an RF-driven L-shaped microcircuit. Successively selecting three crystallographic NV axes by static bias-field control yields maps of RF magnetic-field projection magnitudes, with distinct distributions qualitatively reproduced by Biot-Savart calculations. Transverse bias-field control also tunes the RF-coupled spin-state transition frequency from 14.4 to 89.3 MHz, as characterized by spectroscopy and Hamiltonian analysis, with RF-dressed resonances directly observed in CW-ESDR spectra at 89.3 MHz. Together with previous RF magnetic-field detection up to 632 MHz using the same RF-dressed CW sensing principle in a confocal NV setup, these results support extending AC magnetic-field imaging with SNVM toward the hundreds-of-megahertz regime and, with additional phase information, vector magnetic-field reconstruction.

physics.ins-det↗

Continuous-wave AC magnetometry up to hundreds of megahertz using nitrogen-vacancy centers under a strong transverse magnetic field

Nitrogen-vacancy (NV) centers in diamond are promising quantum sensors for AC magnetic fields. However, conventional dynamical-decoupling-based magnetometry becomes technically demanding at high frequencies because of the requirement for increasingly short and high-power microwave pulses. This paper describes an AC magnetometry technique based on continuous-wave optically detected magnetic resonance (CW-ODMR) measurements, which enables the detection of signals in the hundred-MHz range. By applying a strong static magnetic field transverse to the NV axis, the energy separation between the relevant electron-spin states was tuned and resonantly coupled with the target radiofrequency (RF) magnetic field, thereby forming RF-dressed states. Unlike pulsed dynamical-decoupling schemes, this approach does not require high-power microwave pulse sequences. The key feature of our method is that the detectable frequency can be tuned by controlling the bias magnetic field strength. Using this methodology, we have experimentally achieved the frequency-tunable detection of AC magnetic fields from 14.4-632 MHz. The sensitivity was 0.558 uT/Hz^(0.5) at 14.4 MHz and 24.4 uT/Hz^(0.5) at 632 MHz. We characterized the field-dependent ODMR contrast and linewidth, and found that their degradation at large transverse fields is a important factor limiting the high-frequency sensitivity. These results establish a simple CW-ODMR approach for widely tunable RF magnetic-field sensing without high-power pulsed spin control.

quant-ph↗

Broadband AC Magnetic Field Sensing via Continuous wave optically detected magnetic resonance with NV Centers in diamond

The nitrogen-vacancy (NV) center in diamond has attracted considerable attention as a highly sensitive quantum sensor that can operate at room temperature. In particular, continuous-wave optically detected magnetic resonance (CW-ODMR) is promising for a wide range of applications because of its simplicity. However, conventional AC magnetic-field sensing schemes based on CW-ODMR suffer from a limited detection bandwidth: the detectable frequency is either fixed by intrinsic physical parameters of the NV center or, even when tunable, restricted to a narrow range of only a few MHz. Here, we propose a broadband AC magnetometry scheme based on CW-ODMR with NV centers using microwave-driven dressed states.Through theoretical analysis and numerical simulations, we show that the proposed scheme enables the detection of AC magnetic fields with frequencies up to the order of 100 MHz, which has been difficult to achieve using conventional CW-ODMR-based methods.

quant-ph↗

Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond

The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution, even at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetic field sensing using continuous-wave opticallydetected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF) dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with a RF field at two different frequencies. One creates the RF dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on a RF field with a single frequency. The estimated bandwidth is 7.45 MHz, higher than that of the conventional method using the RF dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.

quant-ph↗

Electron-spin double resonance of nitrogen-vacancy centers in diamond under strong driving field

The nitrogen-vacancy (NV) center in diamond has been the focus of research efforts because of its suitability for use in applications such as quantum sensing and quantum simulations. Recently, the electron-spin double resonance (ESDR) of NV centers has been exploited for detecting radio-frequency (RF) fields with continuous-wave optically detected magnetic resonance. However, the characteristic phenomenon of ESDR under a strong RF field remains to be fully elucidated. In this study, we theoretically and experimentally analyzed the ESDR spectra under strong RF fields by adopting the Floquet theory. Our analytical and numerical calculations could reproduce the ESDR spectra obtained by measuring the spin-dependent photoluminescence under the continuous application of microwaves and an RF field for a DC bias magnetic field perpendicular to the NV axis. We found that anticrossing structures that appear under a strong RF field are induced by the generation of RF-dressed states owing to the two-RF-photon resonances. Moreover, we found that $2n$-RF-photon resonances were allowed by an unintentional DC bias magnetic field parallel to the NV axis. These results should help in the realization of precise MHz-range AC magnetometry with a wide dynamic range beyond the rotating wave approximation regime as well as Floquet engineering in open quantum systems.

quant-ph↗