arXiv Science⌕ Search

arXiv subjects

Ronald L. Walsworth

Publications and source records attributed to Ronald L. Walsworth.

103 records · Page 6Linked to original sources

Low-loss negative refraction by laser induced magneto-electric cross-coupling

We discuss the feasibility of negative refraction with reduced absorption in coherently driven atomic media. Coherent coupling of an electric and a magnetic dipole transition by laser fields induces magneto-electric cross-coupling and negative refraction at dipole densities which are considerably smaller than necessary to achieve a negative permeability. At the same time the absorption gets minimized due to destructive quantum interference and the ratio of negative refraction index to absorption becomes orders of magnitude larger than in systems without coherent cross-coupling. The proposed scheme allows for a fine-tuning of the refractive index. We derive a generalized expression for the impedance of a medium with magneto-electric cross coupling and show that impedance matching to vacuum can easily be achieved. Finally we discuss the tensorial properties of the medium response and derive expressions for the dependence of the refractive index on the propagation direction.

quant-ph↗

A laser frequency comb that enables radial velocity measurements with a precision of 1 cm s$^{-1}$

Searches for extrasolar planets using the periodic Doppler shift of stellar spectral lines have recently achieved a precision of 60 cm/s (ref 1), which is sufficient to find a 5-Earth-mass planet in a Mercury-like orbit around a Sun-like star. To find a 1-Earth-mass planet in an Earthlike orbit, a precision of 5 cm/s is necessary. The combination of a laser frequency comb with a Fabry-Perot filtering cavity has been suggested as a promising approach to achieve such Doppler shift resolution via improved spectrograph wavelength calibration, with recent encouraging results. Here we report the fabrication of such a filtered laser comb with up to 40- GHz (1-A) line spacing, generated from a 1- GHz repetition-rate source, without compromising long-term stability, reproducibility or spectral resolution. This wide-line-spacing comb, or `astro-comb', is well matched to the resolving power of high-resolution astrophysical spectrographs. The astro-comb should allow a precision as high as 1 cm/s in astronomical radial velocity measurements.

astro-ph↗

Slow light with integrated gain and large pulse delay

We demonstrate slow and stored light in Rb vapor with a combination of desirable features: minimal loss and distortion of the pulse shape, and large fractional delay (> 10). This behavior is enabled by: (i) a group index that can be controllably varied during light pulse propagation; and (ii) controllable gain integrated into the medium to compensate for pulse loss. Any medium with the above two characteristics should be able to realize similarly high-performance slow light.

physics.optics↗

Tunable negative refraction without absorption via electromagnetically induced chirality

We show that negative refraction with minimal absorption can be obtained by means of quantum interference effects similar to electromagnetically induced transparency. Coupling a magnetic dipole transition coherently with an electric dipole transition leads to electromagnetically induced chirality, which can provide negative refraction without requiring negative permeability, and also suppresses absorption. This technique allows negative refraction in the optical regime at densities where the magnetic susceptibility is still small and with refraction/absorption ratios that are orders of magnitude larger than those achievable previously. Furthermore, the value of the refractive index can be fine-tuned via external laser fields, which is essential for practical realization of sub-diffraction-limit imaging.

quant-ph↗

Optimal control of light pulse storage and retrieval

We demonstrate experimentally a procedure to obtain the maximum efficiency for the storage and retrieval of light pulses in atomic media. The procedure uses time reversal to obtain optimal input signal pulse-shapes. Experimental results in warm Rb vapor are in good agreement with theoretical predictions and demonstrate a substantial improvement of efficiency. This optimization procedure is applicable to a wide range of systems.

quant-ph↗

Noninvasive measurements of gas exchange in a three-dimensional fluidized bed using hyperpolarized 129Xe NMR

We present a novel NMR technique that provides a non-invasive, direct measurement of gas exchange in a three-dimensional gas-fluidized bed of solid particles. The NMR spectrum of hyperpolarized 129Xe gas in an Al2O3 particle bed displays three resolved peaks corresponding to xenon in bubbles, the interstitial spaces (emulsion), and adsorbed on particles. Modified NMR exchange and saturation-recovery sequences, together with data analysis based on an exchange-coupled set of Bloch equations, yield gas exchange rate constants between the emulsion and adsorbed phases, and between the bubble and emulsion phases. The results are in approximate agreement previously unverified predictions from well-known models of fluidized bed behavior. Incorporation of NMR imaging methodologies would straightforwardly allow similar measurements on a spatially-resolved basis.

cond-mat.mtrl-sci↗

Comparison of 87Rb N-resonances for D1 and D2 transitions

We report an experimental comparison of three-photon-absorption resonances (known as "N-resonances") for the D_1 and D_2 optical transitions of thermal 87Rb vapor. We find that the D_2 N-resonance has better contrast, a broader linewidth, and a more symmetric lineshape than the D_1 N-resonance. Taken together, these factors imply superior performance for frequency standards operating on alkali D_2 N-resonances, in contrast to coherent population trapping (CPT) resonances for which the D_2 transition provides poorer frequency standard performance than the D_1 transition.

physics.atom-ph↗

Cancellation of light-shifts in an N-resonance clock

We demonstrate that first-order light-shifts can be cancelled for an all-optical, three-photon-absorption resonance ("N-resonance") on the D1 transition of Rb87. This light-shift cancellation enables improved frequency stability for an N-resonance clock. For example, using a table-top apparatus designed for N-resonance spectroscopy, we measured a short-term fractional frequency stability (Allan deviation) 1.5e-11 tau^(-1/2) for observation times 1s< tau < 50s. Further improvements in frequency stability should be possible with an apparatus designed as a dedicated N-resonance clock.

physics.optics↗

Diffusion-induced Ramsey narrowing

A novel form of Ramsey narrowing is identified and characterized. For long-lived coherent atomic states coupled by laser fields, the diffusion of atoms in-and-out of the laser beam induces a spectral narrowing of the atomic resonance lineshape. Illustrative experiments and an intuitive analytical model are presented for this diffusion-induced Ramsey narrowing, which occurs commonly in optically-interrogated systems.

quant-ph↗

A novel absorption resonance for all-optical atomic clocks

We report an experimental study of an all-optical three-photon-absorption resonance (known as a "N-resonance") and discuss its potential application as an alternative to atomic clocks based on coherent population trapping (CPT). We present measurements of the N-resonance contrast, width and light-shift for the D1 line of 87Rb with varying buffer gases, and find good agreement with an analytical model of this novel resonance. The results suggest that N-resonances are promising for atomic clock applications.

physics.atom-ph↗

Measurement of persistence in 1D diffusion

Using a novel NMR scheme we observed persistence in 1-D gas diffusion. Analytical approximations and numerical simulations have indicated that for an initially random array of spins undergoing diffusion, the probability p(t) that the average spin magnetization in a given region has not changed sign (i.e., ``persists'') up to time t follows a power law t^{-θ}, where θ depends on the dimensionality of the system. Using laser-polarized ^{129}Xe gas, we prepared an initial ``quasirandom'' 1D array of spin magnetization and then monitored the ensemble's evolution due to diffusion using real-time NMR imaging. Our measurements are consistent with analytical and numerical predictions of θ\approx 0.12.

physics.atom-ph↗

New Clock Comparison Tests of Lorentz Symmetry

We present two new measurements constraining Lorentz and CPT violation using the Xe-129 / He-3 Zeeman maser and atomic hydrogen masers. Experimental investigations of Lorentz and CPT symmetry provide important tests of the framework of the standard model of particle physics and theories of gravity. The two-species Xe-129 / He-3 Zeeman maser bounds violations of CPT and Lorentz symmetry of the neutron at the 10^-31 GeV level. Measurements with atomic hydrogen masers provide a clean limit of CPT and Lorentz symmetry violation of the proton at the 10^-27 GeV level.

physics.atom-ph↗

New Clock Comparison Searches for Lorentz and CPT Violation

We present two new measurements constraining Lorentz and CPT violation using the Xe-129 / He-3 Zeeman maser and atomic hydrogen masers. Experimental investigations of Lorentz and CPT symmetry provide important tests of the framework of the standard model of particle physics and theories of gravity. The two-species Xe-129 / He-3 Zeeman maser bounds violations of CPT and Lorentz symmetry of the neutron at the 10^-31 GeV level. Measurements with atomic hydrogen masers provide a clean limit of CPT and Lorentz symmetry violation of the proton at the 10^-27 GeV level.

physics.atom-ph↗