arXiv Science⌕ Search

arXiv subjects

Roman Kolevatov

Publications and source records attributed to Roman Kolevatov.

7 recordsLinked to original sources

Near-Quantum-Limited Readout for the Princeton Axion Search using a sub-GHz Kinetic Inductance Traveling Wave Parametric Amplifier

Parametric amplifiers are a workhorse for near-quantum-limited measurements above 1 GHz. However, amplifier development has been more limited below 1 GHz. We present a kinetic inductance traveling-wave parametric amplifier (KI-TWPA) operating over 300-700 MHz, with gain exceeding 30 dB and pump powers of a few hundred nanowatts. The system noise performance, as measured by a variable-temperature noise source, is 2.5-3.5 quanta. This device is a versatile new tool for precision measurements of sub-GHz signals, with applications including readout of semiconductor spin qubits, superconducting detector arrays, and searches for new physics beyond the Standard Model. We characterize aspects of the amplifier performance relevant to axion searches, including gain drift, compression point, amplifier noise at various operating temperatures, readout with an input circulator, and magnetic field insensitivity.

quant-ph↗

Cavity Characterization for the Princeton Axion Search

The Princeton Axion Search (PXS) targets the mass window $0.8\text{--}2.1~μ\text{eV}$ (corresponding to frequencies $200\text{--}500~\text{MHz}$) at DFSZ sensitivity. The experiment, a haloscope, will use a cylindrical copper-plated aluminum cavity of $700~\text{mm}$ diameter and $1022~\text{mm}$ height, immersed in a $5~\text{T}$ solenoidal magnetic field. A $152~\text{mm}$ diameter tuning rod spanning the height of the cavity rotates to tune the primary mode resonance from $390\text{--}480~\text{MHz}$, the frequency range for initial operations. We deduce the electric and magnetic field mode patterns using a combination of dielectric and metallic bead perturbations on the empty cavity. The measured mode frequencies and the $\text{TM}_{010}$ field profile, as a function of tuning rod position, are in excellent agreement with simulations. We describe the effect of fabrication and assembly imperfections, including the bowing of end plates and tilt of the tuning rod. The welded seams and end-cap joints are demonstrated to not significantly degrade $Q$. We combine measurement and simulation to assess an uncertainty on form factor across the full tuning range. Our results validate PXS's cavity architecture and inform future searches for sub-$μ\text{eV}$ axions, in which large-volume high-$Q$ structures are required to reach QCD sensitivity.

physics.ins-det↗

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

physics.ins-det↗

High-$Q$ Superconducting Lumped-Element Resonators for Low-Mass Axion Searches

Low-frequency superconducting lumped-element resonators have recently attracted significant attention in the context of axion dark matter searches. Here we present the design and implementation of a fixed-frequency superconducting resonator operating near 250 kHz, possessing an inductor volume of approximately 1 liter and achieving an unloaded quality factor $Q \approx 2.1\times10^{6}$. This resonator represents a significant improvement over the state of the art and informs the design of searches for low-mass axions.

physics.ins-det↗

Nearly scale-invariant curvature modes from entropy perturbations during graceful exit

In this Letter, we describe how a spectrum of entropic perturbations generated during a period of slow contraction can source a nearly scale-invariant spectrum of curvature perturbations on length scales larger than the Hubble radius during the transition from slow contraction to a classical non-singular bounce (the `graceful exit' phase). The sourcing occurs naturally through higher-order scalar field kinetic terms common to classical (non-singular) bounce mechanisms. We present a concrete example in which, by the end of the graceful exit phase, the initial entropic fluctuations have become negligible and the curvature fluctuations have a nearly scale-invariant spectrum with an amplitude consistent with observations.

gr-qc↗

Sourcing curvature modes with entropy perturbations in non-singular bouncing cosmologies

The observed temperature fluctuations in the cosmic microwave background can be traced back to primordial curvature modes that are sourced by adiabatic and/or entropic matter perturbations. In this paper, we explore the entropic mechanism in the context of non-singular bouncing cosmologies. We show that curvature modes are naturally generated during `graceful exit,' i.e., when the smoothing slow contraction phase ends and the universe enters the bounce stage. Here, the key role is played by the kinetic energy components that come to dominate the energy density and drive the evolution towards the cosmological bounce.

gr-qc↗

Superluminality in dilatationally invariant generalized Galileon theories

We consider small perturbations about homogeneous backgrounds in dilatationally-invariant Galileon models. The issues we address are stability (absence of ghosts and gradient instabilities) and superluminality. We show that in Minkowski background, it is possible to construct the Lagrangian in such a way that any homogeneous Galileon background solution is stable and small perturbations about it are subluminal. On the other hand, in the case of FLRW backgrounds, for any Lagrangian functions there exist homogeneous background solutions to the Galileon equation of motion and time-dependence of the scale factor, such that the stability conditions are satisfied, but the Galileon perturbations propagate with superluminal speed. Thus, a popular class of the generalized Galileon models is plagued by superluminality.

hep-th↗