arXiv ScienceSearch

arXiv subjects

Robert Nishikawa

Publications and source records attributed to Robert Nishikawa.

2 recordsLinked to original sources

A Workflow to Efficiently Generate Dense Tissue Ground Truth Masks for Digital Breast Tomosynthesis

Digital breast tomosynthesis (DBT) is now the standard of care for breast cancer screening in the USA. Accurate segmentation of fibroglandular tissue in DBT images is essential for personalized risk estimation, but algorithm development is limited by scarce human-delineated training data. In this study we introduce a time- and labor-saving framework to generate a human-annotated binary segmentation mask for dense tissue in DBT. Our framework enables a user to outline a rough region of interest (ROI) enclosing dense tissue on the central reconstructed slice of a DBT volume and select a segmentation threshold to generate the dense tissue mask. The algorithm then projects the ROI to the remaining slices and iteratively adjusts slice-specific thresholds to maintain consistent dense tissue delineation across the DBT volume. By requiring annotation only on the central slice, the framework substantially reduces annotation time and labor. We used 44 DBT volumes from the DBTex dataset for evaluation. Inter-reader agreement was assessed by computing patient-wise Dice similarity coefficients between segmentation masks produced by two radiologists, yielding a median of 0.84. Accuracy of the proposed method was evaluated by having a radiologist manually segment the 20th and 80th percentile slices from each volume (CC and MLO views; 176 slices total) and calculate Dice scores between the manual and proposed segmentations, yielding a median of 0.83.

cs.CV

Contrast-enhanced dual-energy subtraction imaging using electronic spectrum-splitting and multi-prism x-ray lenses

Dual-energy subtraction imaging (DES) is a method to improve the detectability of contrast agents over a lumpy background. Two images, acquired at x-ray energies above and below an absorption edge of the agent material, are logarithmically subtracted, resulting in suppression of the signal from the tissue background and a relative enhancement of the signal from the agent. Although promising, DES is still not widely used in clinical practice. One reason may be the need for two distinctly separated x-ray spectra that are still close to the absorption edge, realized through dual exposures which may introduce motion unsharpness. In this study, electronic spectrum-splitting with a silicon-strip detector is theoretically and experimentally investigated for a mammography model with iodinated contrast agent. Comparisons are made to absorption imaging and a near-ideal detector using a signal-to-noise ratio that includes both statistical and structural noise. Similar to previous studies, heavy absorption filtration was needed to narrow the spectra at the expense of a large reduction in x-ray flux. Therefore, potential improvements using a chromatic multi-prism x-ray lens (MPL) for filtering were evaluated theoretically. The MPL offers a narrow tunable spectrum, and we show that the image quality can be improved compared to conventional filtering methods.

physics.med-ph