arXiv Science⌕ Search

arXiv subjects

Rayan Ansari

Publications and source records attributed to Rayan Ansari.

3 recordsLinked to original sources

CheXPoT: Post-Hoc Visual Verification and Correction of VLM-Generated Radiology Reports

Vision-language models (VLMs) have shown promise for chest radiograph report generation, but adoption remains limited because of hallucinated findings that are not grounded in the image. Correcting these hallucinations and improving overall report quality remains a significant challenge. Prior work has addressed this problem by refining models with reinforcement learning, preference optimization, or chain-of-thought supervision, often at substantial compute cost. To address this gap, we introduce CheXPoT, a program-of-thought (PoT) framework that verifies each generated finding against image features and removes those it cannot ground. CheXPoT decomposes generated reports into predicates with RadGraph and an LLM, grounds these predicates against a DenseNet-121 and Grad-CAM visual evidence table, executes PoT verification code, and rewrites reports after removing unsupported predicates. On a 4,145-image held-out split, CheXPoT yields statistically significant precision gains on 8 of 14 CheXpert classes and F1 gains on 5, with no significant decreases in either metric. CheXPoT lifts micro-average precision from 19.2% (MedGemma-4B) to 46.8% (MedGemma-4B + CheXPoT) and micro-average F1 from 23.0% to 49.4%, absolute gains of 27.6% and 26.4% respectively. We also tested CheXPoT on other VLM report generators. On LLaVA-Med, CheXPoT lifts micro-average precision from 4.5% to 17.7% and micro-average F1 from 6.3% to 19.4%. On MAIRA-2, CheXPoT lifts micro-average precision from 15.6% to 42.1% and micro-average F1 from 21.0% to 45.3%. Our results suggest that inexpensive post-hoc visual verification may improve VLM trustworthiness by correcting unsupported findings from generated reports. CheXPoT lays a foundation for tools that help validate VLM-generated radiology reports and reduce unsupported findings. These innovations may subsequently help increase trust and adoption of VLM tools in Medicine.

cs.CL↗

Corpus Characterization and Inverse Constitutional Fine-Tuning for Style-Aware Radiology Reports

Automated radiology report generation has advanced rapidly in diagnostic accuracy, yet generated reports frequently diverge from the stylistic conventions of authentic radiologist writing in structure, diction, and uncertainty language, a gap which has direct implications for clinician trust and user experience. To address this, we characterize stylistic variation across 2,000 reports from the CheXpert Plus dataset using Bio-ClinicalBERT embeddings, UMAP dimensionality reduction, and HDBSCAN clustering, identifying five distinct reporting patterns differing in pathology focus, narrative structure, and lexical preference. Drawing on these findings, we adapt the inverse constitutional AI framework to derive a style-focused constitution from radiologist-written report pairs without requiring a formal preference dataset. This constitution, encoding conventions of tone, diction, uncertainty calibration, and report structure, is incorporated into the supervised fine-tuning of a MedGemma-4B base model on 25,245 CheXpert Plus training pairs. Constitutional fine-tuning produces a substantial increases in text alignment (BLEU-4: 0.006 to 0.308; ROUGE-L: 0.171 to 0.484) relative to the untuned baseline. These gains show a qualitative shift in structural and lexical alignment rather than marginal improvement, as the baseline model produces near-zero scores due to format mismatch. Overall, we establish corpus-level style characterization and constitutional modeling as an effective and data-efficient strategy for producing radiology reports that conform to authentic radiologist writing conventions.

cs.CL↗

ConvexECG: Lightweight and Explainable Neural Networks for Personalized, Continuous Cardiac Monitoring

We present ConvexECG, an explainable and resource-efficient method for reconstructing six-lead electrocardiograms (ECG) from single-lead data, aimed at advancing personalized and continuous cardiac monitoring. ConvexECG leverages a convex reformulation of a two-layer ReLU neural network, enabling the potential for efficient training and deployment in resource constrained environments, while also having deterministic and explainable behavior. Using data from 25 patients, we demonstrate that ConvexECG achieves accuracy comparable to larger neural networks while significantly reducing computational overhead, highlighting its potential for real-time, low-resource monitoring applications.

cs.LG↗