arXiv ScienceSearch

arXiv subjects

Raphael Hasse

Publications and source records attributed to Raphael Hasse.

4 recordsLinked to original sources

Measurement of the O$^{-}$ Photodetachment cross-section in the electrostatic storage ring FLSR

The achievable precision of photodetachment studies via tunable laser light has been investigated on circulating oxygen anions at the room-temperature electrostatic low-energy storage ring of Frankfurt University (FLSR) in preparation of investigations on molecular species. For this purpose, the FLSR, originally designed for reaction dynamics studies on positive ions, was upgraded by a source for anions, by the installation of a tunable high repetition rate laser system and by implementation of a transversal interaction region between laser and ion beam. Results on the electron affinity and the ground state fine structure of O$^{-}$, which both serve as a calibration standard, are discussed, exhibiting the performance and accuracy of this new spectroscopic application of the FLSR.

physics.atom-ph

Laser Spectroscopy of Thulium Isotopes Near the (N=82) Shell Closure: Nuclear Moment and Charge Radius of ${}^{152\mathrm{m}}\mathrm{Tm}$

We report on resonance ionization laser spectroscopy measurements performed on both neutron-deficient and neutron-rich thulium ($\mathrm{Tm}, Z=69$) isotopes. Isotope shifts were determined for three atomic ground-state transitions at wavelengths of $389.8\,\mathrm{nm}$, $388.4\,\mathrm{nm}$, and $388.8\,\mathrm{nm}$ in the isotopes ${}^{152\mathrm{m}}\mathrm{Tm}$, ${}^{153}\mathrm{Tm}$, ${}^{154\mathrm{m}}\mathrm{Tm}$, and ${}^{169}\mathrm{Tm}$. In addition, for the $389.8\,\mathrm{nm}$ transition, measurements were extended to the isotope ${}^{170}\mathrm{Tm}$, and the hyperfine structure was partially resolved for all five isotopes. For this transition, the isotope shift could be determined for one more isotope, ${}^{154\mathrm{m}}\mathrm{Tm}$. From the extracted hyperfine coupling constants, the nuclear magnetic dipole moment for ${}^{152\mathrm{m}}\mathrm{Tm}$ was determined for the first time, resulting in $\mu\left({}^{152\mathrm{m}}\mathrm{Tm}\right) = 5.8(3) \mu_\mathrm{N}$. Furthermore, the mean-square nuclear charge radius $\delta\langle r^2\rangle^{152\mathrm{m},169} = -1.86(25)\,\mathrm{fm}^2$ for ${}^{152\mathrm{m}}\mathrm{Tm}$ was extracted from the measured isotope shifts.

nucl-ex

Improved limit on the effective electron neutrino mass with the ECHo-1k experiment

The effective electron neutrino mass can be determined by analyzing the endpoint region of the $^{163}$Ho electron capture spectrum, provided a measurement with high energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in $^{163}$Ho collaboration, ECHo, presents an analysis of the most precise $^{163}$Ho spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of $B=9.1(1.3)\times 10^{-6}$ /eV/pixel/day was achieved allowing for a reliable analysis of the endpoint region. The derived endpoint energy $Q = 2862(4)$ eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of $Q=2863.2(6)$ eV [1]. The upper limit of the effective electron neutrino mass is improved by almost a factor 2 compared to the lowest current value [2], reaching $m_{\nu_\mathrm{e}} < 15 $ eV/c${^2}$ (90\% credible interval).

hep-ex

Diamond-optic enhanced photon collection efficiency for sensing with nitrogen-vacancy centers

We present a design to increase the amount of collected fluorescence emitted by nitrogen-vacancy color centers in diamond used for quantum-sensing. An improvement was measured in collected fluorescence when comparing oppositely faced emitting surfaces by a factor of 3.8(1). This matches ray-tracing simulation results. This design therefore improves on the shot noise limited sensitivity in optical read-out based measurements of for instance magnetic and electric fields, pressure, temperature and rotations.

quant-ph