arXiv ScienceSearch

arXiv subjects

Radhe Mohan

Publications and source records attributed to Radhe Mohan.

15 recordsLinked to original sources

Ridge-filter crosstalk in conformal proton FLASH planning: dependence on beamlet pitch and iterative mitigation

Objective: Patient-specific ridge filters (PSRFs) can enable conformal single-energy proton FLASH delivery without energy switching. However, converting optimized spot-based dose distributions into physically adjacent ridge-filter structures may introduce inter-beamlet modulation errors not captured by conventional isolated-spot optimization. This study characterized ridge-filter (RF) crosstalk, evaluated its dependence on the beam-width-to-pitch relationship, and developed an iterative mitigation strategy. Approach: A Monte Carlo dose influence matrix was generated for monoenergetic proton beamlets passing through RFs of varying thickness. A baseline spot-weighted IMPT plan was optimized to meet dose constraints and converted into PSRF geometries. PSRF dose distributions were calculated by explicitly modeling the PSRF in the scanned beam path. RF crosstalk was quantified by comparing PSRF and baseline IMPT plans. Lateral beamlet spacings of 8, 10, 12, and 15 mm were evaluated using gamma analysis, DVH metrics, and mean relative dose difference. An iterative re-optimization method was tested in water-phantom and patient CT geometries. Results: RF crosstalk produced hot and cold spots, reducing agreement between PSRF and baseline IMPT plans. For the same spot size and target geometry, crosstalk increased as beamlet spacing decreased. Iterative re-optimization substantially reduced dose discrepancies, lowering the mean relative dose difference in the target from 8.9% to 3.4% in water and from 3.7% to 1.8% in CT. Significance: RF crosstalk is an important source of dose inconsistency in ridge-filter-based conformal proton FLASH planning. Its dependence on the beam-width-to-pitch relationship and mitigation through iterative re-optimization provide a practical framework for improving the accuracy and robustness of patient-specific single-energy proton FLASH delivery.

physics.med-ph

Beam modelling of Hitachi PROBEAT proton therapy system for a GPU-based Fast Monte Carlo dose engine

Background: An in-house dose engine independent of clinic TPS is not only a reliable tool for patient QA verification. More importantly, it plays vital role in cutting-edge research due to its flexibility in implementing new functions. In this study, we upgraded our existing beam model with using double-Gaussian distributions for both spatial and opening angle distributions of particles to obtain more accurate phase space files. It is expected to potentially improve the performance of this independent dose engine in both clinic and research at the expanded MD Anderson proton center.

physics.med-ph

A novel Boltzmann equation solver for calculation of dose and fluence spectra distributions for proton beam therapy

The claim that Monte Carlo is the most accurate method is a case of misattributed credit. This claim is based on experience with advanced systems MCNPX, Geant4 and EGS. These systems achieve remarkable performance because they use most accurate physics, not because they use random numbers. The latter simplifies algorithms, but contaminates the solution with random noise. Currently prevalent fast Monte Carlo algorithms retain this worst part while achieving high computing speed at the expense of the best part- accurate physics. We employ an opposite strategy. We develop a Boltzmann solver for protons that retains unchanged the physics of most advanced Monte Carlo systems. We eliminate random noise, because our solution method is deterministic. Our method is also applicable to heavier ions, helium and carbon, for example. Results of the study provide a foundation for achieving a high computing speed with uncompromised accuracy in proton treatment planning systems.

physics.med-ph

Mimicking large spot-scanning radiation fields for proton FLASH preclinical studies with a robotic motion platform

Previously, a synchrotron-based horizontal proton beamline (87.2 MeV) was successfully commissioned to deliver radiation doses in FLASH and conventional dose rate modes to small fields and volumes. In this study, we developed a strategy to increase the effective radiation field size using a custom robotic motion platform to automatically shift the positions of biological samples. The beam was first broadened with a thin tungsten scatterer and shaped by customized brass collimators for irradiating cell/organoid cultures in 96-well plates (a 7-mm-diameter circle) or for irradiating mice (1-cm2 square). Motion patterns of the robotic platform were written in G-code, with 9-mm spot spacing used for the 96-well plates and 10.6-mm spacing for the mice. The accuracy of target positioning was verified with a self-leveling laser system. The dose delivered in the experimental conditions was validated with EBT-XD film attached to the 96-well plate or the back of the mouse. Our film-measured dose profiles matched Monte Carlo calculations well (1D gamma pass rate >95%). The FLASH dose rates were 113.7 Gy/s for cell/organoid irradiation and 191.3 Gy/s for mouse irradiation. These promising results indicate that this robotic platform can be used to effectively increase the field size for preclinical experiments with proton FLASH.

physics.med-ph

A molecular dynamics simulation of the abrupt changes in the thermodynamic properties of water after formation of nano-bubbles / nano-cavities induced by passage of charged particles

We present a multi-scale formalism that accounts for the formation of nano-scale bubbles/cavities owing to a burst of water molecules after the passage of high energy charged particles that leads to the formation of hot non-ionizing excitations or thermal spikes (TS). We demonstrate the coexistence of a rapidly growing condensed state of water and a hot spot that forms a stable state of diluted water at high temperatures and pressures, possibly at a supercritical phase. Depending on the temperature of TS, the thin shell of a highly dense state of water grows by three to five times the speed of sound in water, forming a thin layer of shock wave (SW) buffer, wrapping around the nano-scale cylindrical symmetric cavity. The stability of the cavity, as a result of the incompressibility of water at ambient conditions and the surface tension, allows the transition of supersonic SW to a subsonic contact discontinuity and dissipation to thermo-acoustic sound waves. We further study the mergers of nanobubbles that lead to fountain-like or jet-flow structures at the collision interface. We introduce a time delay in the nucleation of nano-bubbles, a novel mechanism, responsible for the growth and stability of much larger or even micro-bubbles, possibly relevant to FLASH ultra-high dose rate (UHDR). The current study is potentially significant at FLASH-UHDRs. Our analysis predicts the black-body radiation from the transient supercritical state of water localized in nano-cavities wrapping around the track of charged particles can be manifested in the (indirect) water luminescence spectrum.

physics.med-ph

Differential tissue sparing of FLASH ultra high dose rates: an {\it in-silico} study

Purpose: To propose a theory for the differential tissue sparing of FLASH ultra high dose rates (UHDR) through inter-track reaction-diffusion mechanism. Methods: We calculate the time-evolution of particle track-structures using a system of coupled reaction-diffusion equations on a random network designed for molecular transport in porous and disordered media. The network is representative of the intra- and inter-cellular diffusion channels in tissues. Spatial cellular heterogeneities over the scale of track spacing have been constructed by incorporating random fluctuations in the connectivity among network sites. Results: We demonstrate the occurrence of phase separation among the tracks as the complexity in intra- and inter-cellular structural increases. At the weak limit of disorder, such as in water and normal tissue, neighboring tracks melt into each other and form a percolated network of nonreactive species. In contrast, at the strong limit of disorder, tracks evolve individually like isolated islands with negligible inter-track overlap. Thus, the spatio-temporal correlation among the chemical domains decreases as the inter-cellular complexity of the tissue increases (e.g. from normal tissue to fractal-type malignant tissue). Conclusions: The differential sparing of FLASH UHDR in normal and tumor tissue may be explained by differences in inter- and intra-cellular structural complexities between the tissue types. The structural complexities of cancerous cells prevent clustering and chemical interaction of tracks, whereas this interaction prevails and thus leads to sparing in normal tissue.

physics.med-ph

Modeling interspur interactions as a potential mechanism of the FLASH effect

The mechanism responsible for the FLASH effect, normal tissue sparing by ultra-high dose rate (UHDR) irradiation with isoeffective tumor control compared to conventional dose rate (CDR) irradiation, remains undetermined. Here we investigate the contribution of interspur interactions (interactions between radiolytic species of individual particle tracks) to overall radiochemical interactions as a function of irradiation parameters, and suggest an increase in interspur interaction as a potential mechanism for tissue sparing in FLASH radiation therapy. We construct a model that analytically represents the spatiotemporal distribution of spurs in a target volume as a function of irradiation parameters (e.g. dose, dose rate, linear energy transfer), and quantifies the effect of interspur interactions on the ongoing radiochemistry. Spurs evolve under a simplified reaction-diffusion equation with parameters based on Monte Carlo simulations, and interspur interaction is quantified by calculating the expected values of interspur overlap in the target. The model demonstrates that for any set of irradiation parameters, a minimum critical dose and dose rate are necessary to induce significant interspur interaction, and that interspur interactions correlate negatively with beam linear energy transfer at a fixed dose. The model suggests optimal beam parameters, including dose, dose rate, linear energy transfer, and pulse structure, to maximize interspur interactions. Depending on the rate of radical scavenging in the target, which limits interspur interaction, this model predicts that the irradiation parameters necessary to elicit the FLASH effect may coincide with an onset of significant interspur interactions, suggesting that interspur interaction may be the underlying mechanism of the FLASH effect.

physics.med-ph

The effect of non-ionizing excitations on the diffusion of ion species and inter-track correlations in FLASH ultra-high dose rate radiotherapy

We present a microscopic mechanism that accounts for the outward burst of "cold" ion species (IS) in a high-energy particle track due to coupling with ''hot" non-ion species (NIS). IS refers to radiolysis products of ionized molecules, whereas NIS refers to non-ionized excitations of molecules in a medium. The interaction is mediated by a quantized field of acoustic phonons, a channel that allows conversion of thermal energy of NIS to kinetic energy of IS, a flow of heat from the outer to the inner core of the track structure. We demonstrate the coexistence of "hot" NIS with "cold" IS in the radiation track structures right after their generation. NIS, concentrated within nano-scales volumes wrapping around IS, are the main source of intensive heat-waves and the outward burst of IS due to femto-second time scale IS-NIS coupling. By comparing the transport of IS coupled to NIS with identical configurations of non-interacting IS in thermal equilibrium at room temperature, we demonstrate that the energy gain of IS due to the surrounding hot nanoscopic volumes of NIS significantly increases their effective diffusion constants. The much higher diffusion constants predicted in the present model suggest higher inter-track chemical reaction rates at FLASH-UHDR, as well as lower intra-track reaction rates.

physics.med-ph

Optimization of FLASH Proton Beams Using a Track-Repeating Algorithm

Methods: A phase space file in a plane at 202 mm downstream of the beam exit window is generated through tuning parameters to match FDC results with measured or MCNPX Monte Carlo-simulated integrated depth-dose distribution (IDD) and lateral dose profiles. To spread out the Bragg peak, widen the beam and reduce the penumbra, a ridge filter (RF), a high-Z material scatterer and a collimator with compensator are inserted in the beam path and their shapes and sizes have been optimized. The FDC calculations are validated by comparing Geant4 Monte Carlo simulations. In addition, a set of algorithms to automatically choose the optimum dimensions of the beam shaping elements is developed and tested using the same beams. At the last part, dose rates for optimized beams were estimated by scaling their dose distributions to that of their original beams. Results: The optimized 86.4 MeV beam had an 8.5 mm wide spread-out Bragg peak (SOBP) (proximal 90% to distal 90% of the maximum dose), 14.5 mm, 12.0 mm and 11.0 lateral widths with dose above 50%, 80% and 90% respectively and a 2.5 mm penumbra from 80% to 20% in the lateral profile for the energy. The 159.5 MeV beam had a SOBP of 39.0 mm and the lateral widths with dose above 50%, 80% and 90% of 20.5 mm, 15.0 and 12.5 mm when the source to surface distance (SSD) was 550 mm. Wider lateral widths was obtained with increased SSD. The FDC calculations had passing rates higher than 96% using 3mm/3% as the gamma-index criterion comparing with Geant4 simulations for both energies. The set of automatic algorithms can choose the proper dimensions for the high-density scatterer, RF, collimator and compensator efficiently. And the optimized 159.5 MeV beam with different SDDs had entrance dose rate higher than 40 Gy/s if the entrance dose rate of the original beam was 150 Gy/s.

physics.med-ph

Oxygen depletion in FLASH ultra-high-dose-rate radiotherapy: A molecular dynamics simulation

We present a first-principles molecular dynamics (MD) simulation and expound upon a mechanism of oxygen depletion hypothesis to explain the mitigation of normal tissue injury observed in ultra-high-dose-rate (UHDR) FLASH radiotherapy. We simulated damage to a segment of DNA (also representing other bio-molecules such as RNA and proteins) in a simulation box filled with H$_2$O and O$_2$ molecules. Attoseconds physical interactions (ionizations, electronic and vibrational excitations) were simulated by using the Monte Carlo track structure code Geant4-DNA. Immediately after ionization, {\it ab initio} Car-Parrinello molecular dynamics (CPMD) simulation was used to identify which H$_2$O and O$_2$ molecules surrounding the DNA-molecule were converted into reactive oxygen species (ROS). Subsequently, the femto- to nano-second reactions of ROS were simulated by using MD with Reactive Force Field (ReaxFF), to illustrate ROS merging into new types of non-reactive oxygen species (NROS) due to strong coupling among ROS. Time-dependent molecular simulations revealed the formation of metastable and transient spaghetti-like complexes among ROS generated at UHDR. At the higher ROS densities produced under UHDR, stranded chains (i.e., NROS) are produced, mediated through attractive electric polarity forces, hydrogen bonds, and magnetic dipole-dipole interactions among hydroxyl (\ce{^{.}OH}) radicals. NROS tend to be less mobile than cellular biomolecules as opposed to the isolated and sparsely dense ROS generated at conventional dose rates (CDR). We attribute this effect to the suppression of bio-molecular damage induced per particle track. At a given oxygen level, as the dose rate increases, the size and number of NROS chains increase, and correspondingly the population of toxic ROS components decreases.

physics.med-ph

A New Approach to Modeling the Microdosimetry of Proton Therapy Beams

{\bf Introduction}: To revisit the formulation of the mean chord length in microdosimetry and replace it by the particle mean free path appropriate for modelings in radio-biology. {\bf Methods}: We perform a collision-by-collision following by event-by-event Geant4 Monte Carlo simulation and calculate double-averaged stepping-length, $\langle\langle l \rangle\rangle$, for a range of target sizes from mm down to $\mu$m and depth in water. We consider $\langle\langle l \rangle\rangle$ to represent the particle mean free path. {\bf Results}: We show that $\langle\langle l \rangle\rangle$ continuously drops as a function of depth and asymptotically saturates to a minimum value in low energies, where it exhibits a universal scaling behavior, independent of particle nominal beam energy. We correlate $\langle\langle l \rangle\rangle$ to linear density of DNA damage, complexities of initial lethal lesions and illustrate a relative difference between predictive RBEs in model calculations using mean chord length vs. the proposed mean free path. We demonstrate consistency between rapid increase in RBE within and beyond the Bragg peak and $\langle\langle l \rangle\rangle$, a decreasing function of depth. {\bf Discussion and conclusion}: An interplay between localities in imparted energy at nano-meter scale and subsequent physio-chemical processes, causalities and pathways in DNA damage requires substitution of geometrical chord length of cell nuclei by mean-free path of proton and charged particles to account for a mean distance among sequential collisions in DNA materials.

physics.med-ph

A DNA damage multi-scale model for NTCP in proton and hadron therapy

{\bf Purpose}: To develop a first principle and multi-scale model for normal tissue complication probability (NTCP) as a function of dose and LET for proton and in general for particle therapy with a goal of incorporating nano-scale radio-chemical to macro-scale cell biological pathways, spanning from initial DNA damage to tissue late effects. {\bf Methods}: The method is combination of analytical and multi-scale computational steps including (1) derivation of functional dependencies of NTCP on DNA driven cell lethality in nanometer and mapping to dose and LET in millimeter, and (2) 3D-surface fitting to Monte Carlo data set generated based on post radiation image change and gathered for a cohort of 14 pediatric patients treated by scanning beam of protons for ependymoma. We categorize voxel-based dose and LET associated with development of necrosis in NTCP. {\bf Result}: Our model fits well the clinical data, generated for post radiation tissue toxicity and necrosis. The fitting procedure results in extraction of in-{\it vivo} radio-biological $\alpha$-$\beta$ indices and their numerical values. {\bf Discussion and conclusion}: The NTCP model, explored in this work, allows to correlate the tissue toxicities to DNA initial damage, cell lethality and the properties and qualities of radiation, dose and LET.

physics.med-ph

Renormalization of radiobiological response functions by energy loss fluctuations and complexities in chromosome aberration induction: deactivation theory for proton therapy from cells to tumor control

We employ a multi-scale mechanistic approach to investigate radiation induced cell toxicities and deactivation mechanisms as a function of linear energy transfer in hadron therapy. Our theoretical model consists of a system of Markov chains in microscopic and macroscopic spatio-temporal landscapes, i.e., stochastic birth-death processes of cells in millimeter-scale colonies that incorporates a coarse-grained driving force to account for microscopic radiation induced damage. The coupling, hence the driving force in this process, stems from a nano-meter scale radiation induced DNA damage that incorporates the enzymatic end-joining repair and mis-repair mechanisms. We use this model for global fitting of the high-throughput and high accuracy clonogenic cell-survival data acquired under exposure of the therapeutic scanned proton beams, the experimental design that considers $\gamma$-H2AX as the biological endpoint and exhibits maximum observed achievable dose and LET, beyond which the majority of the cells undergo collective biological deactivation processes. An estimate to optimal dose and LET calculated from tumor control probability by extension to $~ 10^6$ cells per $mm$-size voxels is presented. We attribute the increase in degree of complexity in chromosome aberration to variabilities in the observed biological responses as the beam linear energy transfer (LET) increases, and verify consistency of the predicted cell death probability with the in-vitro cell survival assay of approximately 100 non-small cell lung cancer (NSCLC) cells.

physics.med-ph

A model for relative biological effectiveness of therapeutic proton beams based on a global fit of cell survival data

We introduce an approach for global fitting of the recently published high-throughput and high accuracy clonogenic cell-survival data for therapeutic scanned proton beams. Our fitting procedure accounts for the correlation between the cell-survival, the absorbed (physical) dose and the proton linear energy transfer (LET). The fitting polynomials and constraints have been constructed upon generalization of the microdosimetric kinetic model (gMKM) adapted to account for the low energy and high lineal-energy spectrum of the beam where the current radiobiological models may underestimate the reported relative biological effectiveness (RBE). The parameters ({\alpha},\b{eta}) of the linear-quadratic (LQ) model calculated by the presented method reveal a smooth transition from low to high LETs which is an advantage of the current method over methods previously employed to fit the same clonogenic data. Finally, the presented approach provides insight into underlying microscopic mechanisms which, with future study, may help to elucidate radiobiological responses along the Bragg curve and resolve discrepancies between experimental data and current RBE models.

physics.med-ph

Algorithm and performance of a clinical IMRT beam-angle optimization system

This paper describes the algorithm and examines the performance of an IMRT beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated annealing (FSA) algorithm. An IMRT beam-profile optimization is performed on each generated set of beams. The IMRT optimization is accelerated by using a fast dose calculation method that utilizes a precomputed dose kernel. A compact kernel is constructed for each of the predefined beams prior to starting the FSA algorithm. The IMRT optimizations during the BAO are then performed using these kernels in a fast dose calculation engine. This technique allows the IMRT optimization to be performed more than two orders of magnitude faster than a similar optimization that uses a convolution dose calculation engine.

physics.med-ph