arXiv ScienceSearch

arXiv subjects

Raden Muaz

Publications and source records attributed to Raden Muaz.

2 recordsLinked to original sources

FetSelect: Task-Specific Architectures and Self-Supervised Learning for Automated Fetal Ultrasound Frame Selection

Automated frame selection for fetal biometry remains under addressed, with most prior work targeting generic quality assessment or downstream measurement pipelines that assume suitable frames are available. We introduce FetSelect, a task-specific framework that pairs a frozen vision foundation backbone with a hybrid multi-head design: a Task-Gated classification head and a Detection-derived quality head combined via learned fusion. We curate 6,486 expert-labeled frames across four targets: Crown-Rump Length (CRL), Nuchal Translucency (NT), Nasal Bone (NB), and Scalebar, and adapt the backbone with BYOL pretraining on 19,019 unlabeled images. On a held-out test set (974 frames), FetSelect achieves mean AUROC 0.956 and mean correlation 0.818 with expert quality annotations. Ablations confirm that hybrid fusion surpasses single-head variants, and ultrasound-specific self-supervision yields consistent gains. Evaluation on external clinical videos and 509 external CRL images demonstrates task-specific discrimination.

cs.CV

FADA: Accessible fetal ultrasound interpretation and annotation with a selectively distilled unified vision-language model

A global shortage of trained sonographers limits prenatal ultrasound screening in low- and middle-income countries, where over half of pregnant women receive no skilled sonography. Current deep learning approaches address detection, segmentation, or classification in isolation, each demanding a separate model and expert-specified labels at inference. We present FADA, a unified vision-language model built on Qwen3.5-VL that performs clinical interpretation, classification, detection, and segmentation through a single interpretation-first pipeline without external labels. FADA distills knowledge from four domain-specific foundation models (FetalCLIP, UltraSAM, USF-MAE, UltraFedFM) via offline pre-computed feature caching. Selective distillation, which applies feature alignment only to annotation tasks while interpretation relies on standard fine-tuning, consistently outperforms full distillation across most evaluation axes. The recommended variant, FADA-SKD, achieves 0.8820 mean Dice for segmentation, 0.7671 mAP@0.50 for detection, and 100% structured interpretation compliance. Expert sonographer validation across 237 images confirms clinically acceptable outputs in both autonomous and human-in-the-loop modes, with 73.5% of interpretations scoring perfectly under clinician guidance. The system is trainable on a single consumer GPU and deployable without cloud connectivity. We validate edge deployment by running the compressed 0.8B model on a commodity smartphone (Qualcomm Snapdragon 7 Gen 1, 12 GB RAM) using llama.cpp with GGUF quantization, completing the full 5-phase pipeline in approximately 60 seconds entirely offline. This establishes a practical pathway for integrating AI-assisted fetal assessment with portable ultrasound devices, directly addressing diagnostic access gaps in resource-constrained settings. Code, models, and data are available at https://github.com/mahmoodphd/FADA.

cs.CV