arXiv ScienceSearch

arXiv subjects

R. Pohl

Publications and source records attributed to R. Pohl.

16 recordsLinked to original sources

Charge radii of Cl isotopes from x-ray spectroscopy of muonic atoms

Nuclear charge radii are vital for nuclear and atomic physics, the determination of fundamental constants, and searches for new physics. Muonic atoms, where a single negative muon orbits a nucleus, are sensitive tools for determining nuclear radii due to the large wavefunction overlap of the muon and nucleus. Here we report on a new measurement of the $2, 3, 4p\to1s$ x-ray energies in muonic $^{35,37}$Cl with uncertainties reaching 18 ppm. By employing a large-scale germanium detector array, it was possible to extract these energies from a high statistics dataset using highly enriched samples of only a few tens of milligrams. Combining these results with state-of-the-art atomic and nuclear theory input, the charge radii of the stable chlorine isotopes were determined to be $R(^{35}\text{Cl}) = 3.3333(23)~fm$ and $R(^{37}\text{Cl}) = 3.3444(23)~fm$. This is an order of magnitude more precise and significantly different from previously tabulated values. Our new values solve a discrepancy observed for the charge radius difference in mirror nuclei, agreeing with the overall global trend. The charge radius difference $\delta \langle r^2 \rangle (^{37}\text{Cl} - {^{35}\text{Cl}}) = -0.0776(64)~fm^2$ we extract is 25 times more precise than the previous values. This precision is crucial for establishing reference values for future laser spectroscopy measurements of radioactive isotopes.

nucl-ex

Modern approach to muonic x-ray spectroscopy demonstrated through the measurement of stable Cl radii

Recent advances in muonic x-ray experiments have reinvigorated efforts in measurements of absolute nuclear charge radii. Here, a modern approach is presented, and demonstrated through determination of the charge radii of the two stable chlorine nuclides $^{35}$Cl and $^{37}$Cl. Knowledge of these radii has implications for fundamental studies in nuclear and atomic physics. For this purpose, a state-of-the-art experiment was performed at the $\pi$E1 beamline in the Paul Scherrer Institute (Switzerland), using a large-scale HPGe detector array in order to extract precise energies of the muonic $^{35}$Cl and $^{37}$Cl $np1s$ transitions. The nuclear charge radius extraction relies on modern calculations for QED effects and nuclear polarization with rigorous uncertainty quantification, including effects that were not accounted for in older studies. Additionally, we established a new method for applying the nuclear shape correction directly from energy density functionals, which are amenable to isotopes for which no high-quality electron scattering experiments are available. The resulting charge radii are $3.3335(23) fm$ for $^{35}$Cl and $3.3445(23) fm$ for $^{37}$Cl, thus improving the uncertainty of the available electron scattering values by a factor of seven. The correlation of several observables was evaluated between the different isotopes in order to produce a more precise value of the differential mean square charge radius $\delta \langle r^2 \rangle^{37, 35}=+0.0771(66) fm^{2}$. In this case, improvement of the uncertainty by more than one order of magnitude was achieved compared to the literature value. This precision is sufficient to use this differential as input for isotope shift factor determination.

nucl-ex

Comprehensive theory of the Lamb shift in light muonic atoms

A comprehensive theory of the Lamb shift in light muonic atoms such as $\mu$H, $\mu$D, $\mu^3$He$^+$, and $\mu^4$He$^+$ is presented, with all quantum electrodynamic corrections included at the precision level constrained by the uncertainty of nuclear structure effects. This analysis can be used in the global adjustment of fundamental constants and in the determination of nuclear charge radii. Further improvements in the understanding of electromagnetic interactions of light nuclei will allow for a promising test of fundamental interactions by comparison with ``normal" atomic spectroscopy, in particular, with H-D and $^3$He-$^4$He isotope shifts.

physics.atom-ph

Diffusion of muonic hydrogen in hydrogen gas and the measurement of the 1$s$ hyperfine splitting of muonic hydrogen

The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($\mu$p) with 1 ppm accuracy by means of pulsed laser spectroscopy. In the proposed experiment, the $\mu$p atom is excited by a laser pulse from the singlet to the triplet hyperfine sub-levels, and is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after this cycle modifies the $\mu$p atom diffusion in the hydrogen gas and the arrival time of the $\mu$p atoms at the target walls. This laser-induced modification of the arrival times is used to expose the atomic transition. In this paper we present the simulation of the $\mu$p diffusion in the H$_2$ gas which is at the core of the experimental scheme. These simulations have been implemented with the Geant4 framework by introducing various low-energy processes including the motion of the H$_2$ molecules, i.e. the effects related with the hydrogen target temperature. The simulations have been used to optimize the hydrogen target parameters (pressure, temperatures and thickness) and to estimate signal and background rates. These rates allow to estimate the maximum time needed to find the resonance and the statistical accuracy of the spectroscopy experiment.

physics.atom-ph

Muonic atom spectroscopy with microgram target material

Muonic atom spectroscopy -- the measurement of the x rays emitted during the formation process of a muonic atom -- has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However, so far only targets of at least a few hundred milligram could be used as it required to stop a muon beam directly in the target to form the muonic atom. We have developed a new method relying on repeated transfer reactions taking place inside a 100-bar hydrogen gas cell with an admixture of 0.25% deuterium that allows us to drastically reduce the amount of target material needed while still offering an adequate efficiency. Detailed simulations of the transfer reactions match the measured data, suggesting good understanding of the processes taking place inside the gas mixture. As a proof of principle we demonstrate the method with a measurement of the 2p-1s muonic x rays from a 5-{\mu}g gold target.

nucl-ex

Laser excitation of the 1s-hyperfine transition in muonic hydrogen

The CREMA collaboration is pursuing a measurement of the ground-state hyperfine splitting (HFS) in muonic hydrogen ($\mu$p) with 1 ppm accuracy by means of pulsed laser spectroscopy to determine the two-photon-exchange contribution with $2\times10^{-4}$ relative accuracy. In the proposed experiment, the $\mu$p atom undergoes a laser excitation from the singlet hyperfine state to the triplet hyperfine state, {then} is quenched back to the singlet state by an inelastic collision with a H$_2$ molecule. The resulting increase of kinetic energy after the collisional deexcitation is used as a signature of a successful laser transition between hyperfine states. In this paper, we calculate the combined probability that a $\mu$p atom initially in the singlet hyperfine state undergoes a laser excitation to the triplet state followed by a collisional-induced deexcitation back to the singlet state. This combined probability has been computed using the optical Bloch equations including the inelastic and elastic collisions. Omitting the decoherence effects caused by {the laser bandwidth and }collisions would overestimate the transition probability by more than a factor of two in the experimental conditions. Moreover, we also account for Doppler effects and provide the matrix element, the saturation fluence, the elastic and inelastic collision rates for the singlet and triplet states, and the resonance linewidth. This calculation thus quantifies one of the key unknowns of the HFS experiment, leading to a precise definition of the requirements for the laser system and to an optimization of the hydrogen gas target where $\mu$p is formed and the laser spectroscopy will occur.

physics.atom-ph

The measurement of the quadrupole moment of 185-Re and 187-Re from the hyperfine structure of muonic X rays

The hyperfine splitting of the 5g -> 4f transitions in muonic 185,187-Re has been measured using high resolution HPGe detectors and compared to state-of-the-art atomic theoretical predictions. The spectroscopic quadrupole moment has been extracted using modern fitting procedures and compared to the values available in literature obtained from muonic X rays of natural rhenium. The extracted values of the nuclear spectroscopic quadrupole moment are 2.07(5) barn and 1.94(5) barn, respectively for 185-Re and 187-Re. This work is part of a larger effort at the Paul Scherrer Institut towards the measurement of the nuclear charge radii of radioactive elements.

nucl-ex

Compact 20-pass thin-disk amplifier insensitive to thermal lensing

We present a multi-pass amplifier which passively compensates for distortions of the spherical phase front occurring in the active medium. The design is based on the Fourier transform propagation which makes the output beam parameters insensitive to variation of thermal lens effects in the active medium. The realized system allows for 20 reflections on the active medium and delivers a small signal gain of 30 with M$^2$ = 1.16. Its novel geometry combining Fourier transform propagations with 4f-imaging stages as well as a compact array of adjustable mirrors allows for a layout with a footprint of 400 mm x 1000 mm.

physics.optics

The next generation of laser spectroscopy experiments using light muonic atoms

Precision spectroscopy of light muonic atoms provides unique information about the atomic and nuclear structure of these systems and thus represents a way to access fundamental interactions, properties and constants. One application comprises the determination of absolute nuclear charge radii with unprecedented accuracy from measurements of the 2S$\,$-$\,$2P Lamb shift. Here, we review recent results of nuclear charge radii extracted from muonic hydrogen and helium spectroscopy and present experiment proposals to access light muonic atoms with $Z \geq 3$. In addition, our approaches towards a precise measurement of the Zemach radii in muonic hydrogen ($\mu$p) and helium ($\mu$$^{3}$He$^{+}$) are discussed. These results will provide new tests of bound-state quantum-electrodynamics in hydrogen-like systems and can be used as benchmarks for nuclear structure theories.

physics.atom-ph

The proton radius puzzle

High-precision measurements of the proton radius from laser spectroscopy of muonic hydrogen demonstrated up to six standard deviations smaller values than obtained from electron-proton scattering and hydrogen spectroscopy. The status of this discrepancy, which is known as the proton radius puzzle will be discussed in this paper, complemented with the new insights obtained from spectroscopy of muonic deuterium.

physics.atom-ph

Thin-disk laser pump schemes for large number of passes and moderate pump source quality

Novel thin-disk laser pump layouts are proposed yielding an increased number of passes for a given pump module size and pump source quality. These novel layouts result from a general scheme which bases on merging two simpler pump optics arrangements. Some peculiar examples can be realized by adapting standard commercially available pump optics simply by intro ducing an additional mirror-pair. More pump passes yield better efficiency, opening the way for usage of active materials with low absorption. In a standard multi-pass pump design, scaling of the number of beam passes brings ab out an increase of the overall size of the optical arrangement or an increase of the pump source quality requirements. Such increases are minimized in our scheme, making them eligible for industrial applications

physics.optics

Thin-disk laser multi-pass amplifier

In the context of the Lamb shift measurement in muonic helium we developed a thin-disk laser composed of a Q-switched oscillator and a multi-pass amplifier delivering pulses of 150 mJ at a pulse duration of 100 ns. Its peculiar requirements are stochastic trigger and short delay time (< 500 ns) between trigger and optical output. The concept of the thin-disk laser allows for energy and power scaling with high efficiency. However the single pass gain is small (about 1.2). Hence a multi-pass scheme with precise mode matching for large beam waists (w = 2 mm) is required. Instead of using the standard 4f design, we have developed a multi-pass amplifier with a beam propagation insensitive to thermal lens effects and misalignments. The beam propagation is equivalent to multiple roundtrips in an optically stable resonator. To support the propagation we used an array of 2 x 8 individually adjustable plane mirrors. Astigmatism has been minimized by a compact mirror placement. Precise alignment of the kinematic array was realized using our own mirror mount design. A small signal gain of 5 for 8 passes at a pump power of 400 W was reached. The laser was running for more than 3 months without the need of realignment. Pointing stability studies is also reported here.

physics.optics

Experiments towards resolving the proton charge radius puzzle

We review the status of the proton charge radius puzzle. Emphasis is given to the various experiments initiated to resolve the conflict between the muonic hydrogen results and the results from scattering and regular hydrogen spectroscopy.

physics.atom-ph

Characterization of large area avalanche photodiodes in X-ray and VUV-light detection

The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.

physics.ins-det

Muonic hydrogen cascade time and lifetime of the short-lived $2S$ state

Metastable ${2S}$ muonic-hydrogen atoms undergo collisional ${2S}$-quenching, with rates which depend strongly on whether the $\mu p$ kinetic energy is above or below the ${2S}\to {2P}$ energy threshold. Above threshold, collisional ${2S} \to {2P}$ excitation followed by fast radiative ${2P} \to {1S}$ deexcitation is allowed. The corresponding short-lived $\mu p ({2S})$ component was measured at 0.6 hPa $\mathrm{H}_2$ room temperature gas pressure, with lifetime $\tau_{2S}^\mathrm{short} = 165 ^{+38}_{-29}$ ns (i.e., $\lambda_{2S}^\mathrm{quench} = 7.9 ^{+1.8}_{-1.6} \times 10^{12} \mathrm{s}^{-1}$ at liquid-hydrogen density) and population $\epsilon_{2S}^\mathrm{short} = 1.70^{+0.80}_{-0.56}$ % (per $\mu p$ atom). In addition, a value of the $\mu p$ cascade time, $T_\mathrm{cas}^{\mu p} = (37\pm5)$ ns, was found.

physics.atom-ph

Planar LAAPDs: Temperature Dependence, Performance, and Application in Low Energy X-ray Spectroscopy

An experiment measuring the 2S Lamb shift in muonic hydrogen mup is being performed at the Paul Scherrer Institute, Switzerland. It requires small and compact detectors for 1.9 keV x rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We have chosen Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as x-ray detectors, and they were used during the last data taking period in 2003. For x-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise, hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to alpha particles are presented.

physics.ins-det