arXiv ScienceSearch

arXiv subjects

R. Killick

Publications and source records attributed to R. Killick.

At least 19 recordsLinked to original sources

Search and evacuation with a near majority of faulty agents

There are $n\geq 3$ unit speed mobile agents placed at the origin of the infinite line. In as little time as possible, the agents must find and evacuate from an exit placed at an initially unknown location on the line. The agents can communicate in the wireless mode in order to facilitate the evacuation (i.e. by announcing the target's location when it is found). However, among the agents are a subset of at most $f$ crash faulty agents who may fail to announce the target when they visit its location. In this paper we study this aforementioned problem for the specific case that $n=2f+1$. We introduce a novel type of search algorithm and analyze its competitive ratio -- the supremum, over all possible target locations, of the ratio of the time the agents take to evacuate divided by the initial distance between the agents and the target. In particular, we demonstrate that the competitive ratio of evacuation is at most $7.437011$ for $(n,f)=(3,1)$; at most $7.253767$ for $(n,f)=(5,2)$ and $(7,3)$; and at most $7.147026$ for $(n,f)=(9,4)$. For larger values of $n=2f+1$ we prove an asymptotic upper bound of $4+2\sqrt{2}$. We also adapt our evacuation algorithm for $(n,f)=(3,1)$ to the problem of search by three agents with one byzantine fault, i.e. the faulty agent may also lie about finding the target. In doing so we improve the best known upper bound on this search problem from 8.653055 to 7.437011.

cs.DS

The EXO-200 detector, part II: Auxiliary Systems

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

physics.ins-det

Graph Exploration by Energy-Sharing Mobile Agents

We consider the problem of collective exploration of a known $n$-node edge-weighted graph by $k$ mobile agents that have limited energy but are capable of energy transfers. The agents are initially placed at an arbitrary subset of nodes in the graph, and each agent has an initial, possibly different, amount of energy. The goal of the exploration problem is for every edge in the graph to be traversed by at least one agent. The amount of energy used by an agent to travel distance $x$ is proportional to $x$. In our model, the agents can {\em share} energy when co-located: when two agents meet, one can transfer part of its energy to the other. For an $n$-node path, we give an $O(n+k)$ time algorithm that either finds an exploration strategy, or reports that one does not exist. For an $n$-node tree with $\ell $ leaves, we give an $O(n+ \ell k^2)$ algorithm that finds an exploration strategy if one exists. Finally, for the general graph case, we show that the problem of deciding if exploration is possible by energy-sharing agents is NP-hard, even for 3-regular graphs. In addition, we show that it is always possible to find an exploration strategy if the total energy of the agents is at least twice the total weight of the edges; moreover, this is asymptotically optimal.

cs.DM

nEXO Pre-Conceptual Design Report

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta ($0\nu\beta\beta$) decay search in $^{136}$Xe, based on the ultra-low background liquid xenon technology validated by EXO-200. With $\simeq$ 5000 kg of xenon enriched to 90% in the isotope 136, nEXO has a projected half-life sensitivity of approximately $10^{28}$ years. This represents an improvement in sensitivity of about two orders of magnitude with respect to current results. Based on the experience gained from EXO-200 and the effectiveness of xenon purification techniques, we expect the background to be dominated by external sources of radiation. The sensitivity increase is, therefore, entirely derived from the increase of active mass in a monolithic and homogeneous detector, along with some technical advances perfected in the course of a dedicated R&D program. Hence the risk which is inherent to the construction of a large, ultra-low background detector is reduced, as the intrinsic radioactive contamination requirements are generally not beyond those demonstrated with the present generation $0\nu\beta\beta$ decay experiments. Indeed, most of the required materials have been already assayed or reasonable estimates of their properties are at hand. The details described herein represent the base design of the detector configuration as of early 2018. Where potential design improvements are possible, alternatives are discussed. This design for nEXO presents a compelling path towards a next generation search for $0\nu\beta\beta$, with a substantial possibility to discover physics beyond the Standard Model.

physics.ins-det

Priority Evacuation from a Disk Using Mobile Robots

We introduce and study a new search-type problem with ($n+1$)-robots on a disk. The searchers (robots) all start from the center of the disk, have unit speed, and can communicate wirelessly. The goal is for a distinguished robot (the queen) to reach and evacuate from an exit that is hidden on the perimeter of the disk in as little time as possible. The remaining $n$ robots (servants) are there to facilitate the queen's objective and are not required to reach the hidden exit. We provide upper and lower bounds for the time required to evacuate the queen from a unit disk. Namely, we propose an algorithm specifying the trajectories of the robots which guarantees evacuation of the queen in time always better than $2 + 4(\sqrt{2}-1) \frac{\pi}{n}$ for $n \geq 4$ servants. We also demonstrate that for $n \geq 4$ servants the queen cannot be evacuated in time less than $2+\frac{\pi}{n}+\frac{2}{n^2}$.

cs.DM

Sensitivity and discovery potential of the proposed nEXO experiment to neutrinoless double beta decay

The next-generation Enriched Xenon Observatory (nEXO) is a proposed experiment to search for neutrinoless double beta ($0\nu\beta\beta$) decay in $^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time projection chamber. This improvement of two orders of magnitude in sensitivity over current limits is obtained by a significant increase of the $^{136}$Xe mass, the monolithic and homogeneous configuration of the active medium, and the multi-parameter measurements of the interactions enabled by the time projection chamber. The detector concept and anticipated performance are presented based upon demonstrated realizable background rates.

nucl-ex

Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector

The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20~V/cm and 615~V/cm using EXO-200 data. At the operating field of 380~V/cm EXO-200 measures a drift velocity of 1.705$_{-0.010}^{+0.014}$~mm/$\mu$s and a transverse diffusion coefficient of 55$\pm$4~cm$^2$/s.

physics.ins-det

An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout

The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across multiple channels in the presence of correlated noise. The implementation of these techniques improves the energy resolution of the detector at the neutrinoless double beta decay Q-value from $\left[1.9641\pm 0.0039\right]\%$ to $\left[1.5820\pm 0.0044\right]\%$.

physics.ins-det

First Search for Lorentz and CPT Violation in Double Beta Decay with EXO-200

A search for Lorentz- and CPT-violating signals in the double beta decay spectrum of $^{136}$Xe has been performed using an exposure of 100 kg$\cdot$yr with the EXO-200 detector. No significant evidence of the spectral modification due to isotropic Lorentz-violation was found, and a two-sided limit of $-2.65 \times 10^{-5 } \; \textrm{GeV} < \mathring{a}^{(3)}_{\text{of}} < 7.60 \times 10^{-6} \; \textrm{GeV}$ (90% C.L.) is placed on the relevant coefficient within the Standard-Model Extension (SME). This is the first experimental study of the effect of the SME-defined oscillation-free and momentum-independent neutrino coupling operator on the double beta decay process.

nucl-ex

Cosmogenic Backgrounds to 0{\nu}{\beta}{\beta} in EXO-200

As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste Isolation Pilot Plant (WIPP) has been measured to be {\Phi} = 4.07 $\pm$ 0.14 (sys) $\pm$ 0.03 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$, with a vertical intensity of $I_{v}$ = 2.97$^{+0.14}_{-0.13}$ (sys) $\pm$ 0.02 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$ sr$^{-1}$. Simulations of muon-induced backgrounds identified several potential cosmogenic radionuclides, though only 137Xe is a significant background for the 136Xe 0{\nu}{\beta}{\beta} search with EXO-200. Muon-induced neutron backgrounds were measured using {\gamma}-rays from neutron capture on the detector materials. This provided a measurement of 137Xe yield, and a test of the accuracy of the neutron production and transport simulations. The independently measured rates of 136Xe neutron capture and of 137Xe decay agree within uncertainties. Geant4 and FLUKA simulations were performed to estimate neutron capture rates, and these estimates agreed to within ~40% or better with measurements. The ability to identify 136Xe(n,{\gamma}) events will allow for rejection of 137Xe backgrounds in future 0{\nu}{\beta}{\beta} analyses.

nucl-ex

Search for $2\nu\beta\beta$ decay of $^{136}$Xe to the 0$_1^+$ excited state of $^{136}$Ba with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe to the ground state of $^{136}$Ba. We report here on a search for the two-neutrino double-beta decay of $^{136}$Xe to the first $0^+$ excited state, $0^+_1$, of $^{136}$Ba based on a 100 kg$\cdot$yr exposure of $^{136}$Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of $1.7 \times 10^{24}$ yr. We find no statistically significant evidence for the $2\nu\beta\beta$ decay to the excited state resulting in a lower limit of $T^{2\nu}_{1/2}$ ($0^+ \rightarrow 0^+_1$) $> 6.9 \times 10^{23}$ yr at 90% CL. This observed limit is consistent with the estimated half-life of $2.5\times10^{25}$ yr.

nucl-ex

Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200

Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer drift times. Initially the ions have a mobility of $0.390 \pm 0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time constants associated with the change in mobility during drift of the $^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron lifetime in the LXe.

nucl-ex

Investigation of radioactivity-induced backgrounds in EXO-200

The search for neutrinoless double-beta decay (0{\nu}{\beta}{\beta}) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0{\nu}{\beta}{\beta} signal. We report on studies of various {\beta}- and {\gamma}-backgrounds in the liquid- xenon-based EXO-200 0{\nu}{\beta}{\beta} experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.

physics.ins-det

Spectroscopy of Ba and Ba$^+$ deposits in solid xenon for barium tagging in nEXO

Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba$^+$ deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of $\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.

physics.atom-ph

Search for Majoron-emitting modes of double-beta decay of $^{136}$Xe with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee} >|<$ (0.8-1.7)$\cdot$10$^{-5}$.

hep-ex

An apparatus to manipulate and identify individual Ba ions from bulk liquid Xe

We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight (TOF) mass spectroscopy for positive identification of the barium decay product.

physics.ins-det

Search for Majorana neutrinos with the first two years of EXO-200 data

Many extensions of the Standard Model of particle physics suggest that neutrinos should be Majorana-type fermions, but this assumption is difficult to confirm. Observation of neutrinoless double-beta decay ($0\nu \beta \beta$), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with $^{76}$Ge (GERDA experiment) and $^{136}$Xe (KamLAND-Zen and EXO-200 experiments) have established the lifetime of this decay to be longer than $10^{25}$ yr, corresponding to a limit on the neutrino mass of 0.2-0.4 eV. Here we report new results from EXO-200 based on 100 kg$\cdot$yr of $^{136}$Xe exposure, representing an almost fourfold increase from our earlier published datasets. We have improved the detector resolution at the $^{136}$Xe double-beta-decay Q-value to $\sigma$/E = 1.53% and revised the data analysis. The obtained half-life sensitivity is $1.9\cdot10^{25}$ yr, an improvement by a factor of 2.7 compared to previous EXO-200 results. We find no statistically significant evidence for $0\nu \beta \beta$ decay and set a half-life limit of $1.1\cdot10^{25}$ yr at 90% CL. The high sensitivity holds promise for further running of the EXO-200 detector and future $0\nu \beta \beta$ decay searches with nEXO.

nucl-ex

An improved measurement of the 2\nu \beta \beta\ half-life of Xe-136 with EXO-200

We report on an improved measurement of the 2\nu \beta \beta\ half-life of Xe-136 performed by EXO-200. The use of a large and homogeneous time projection chamber allows for the precise estimate of the fiducial mass used for the measurement, resulting in a small systematic uncertainty. We also discuss in detail the data analysis methods used for double-beta decay searches with EXO-200, while emphasizing those directly related to the present measurement. The Xe-136 2\nu \beta \beta\ half-life is found to be 2.165 +- 0.016 (stat) +- 0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any 2\nu \beta \beta\ decay to date.

nucl-ex