arXiv ScienceSearch

arXiv subjects

R. Jones

Publications and source records attributed to R. Jones.

At least 19 recordsLinked to original sources

Constraining the size, shape, and albedo of the large Trans-Neptunian Object (28978) Ixion with multi-chord stellar occultations

Trans-Neptunian objects (TNOs) are among the most primitive remnants of the early Solar System, and constraining their sizes, shapes, albedos, and surface properties is essential for understanding their origin and evolution. Stellar occultations provide highly accurate size and shape measurements for TNOs, while photometry constrains their albedo and surface colours. (28978) Ixion is one of the largest TNOs and a prominent Plutino, making it a key target for comparative studies. We aim to constrain Ixion's projected size, shape, absolute magnitude, geometric albedo, and surface colours, and to search for evidence of an atmosphere or circum-object material. We analysed stellar occultation campaigns by Ixion conducted between 2020 and 2023 within the Lucky Star collaboration, comprising 51 observations from eight events, including 30 positive detections. Five multi-chord events enabled a global limb fit and an accurate reconstruction of Ixion's projected shape. The occultations reveal a slightly elongated limb well represented by a single projected ellipse, yielding an area-equivalent diameter of $D_{\mathrm{equiv}} = 696.78^{+10.75}_{-8.87}$ km and an apparent oblateness $\epsilon' = 0.081^{+0.004}_{-0.010}$. Typical radial residuals of order $\sim$10 km indicate a largely stable shape across epochs, with modest epoch-dependent variations. Calibrated photometric data yield an absolute magnitude of $H_V = 3.845 \pm 0.006$, a phase-curve slope of $\beta = 0.1301 \pm 0.0078$ mag deg$^{-1}$, and a visible geometric albedo of $p_V = 0.106^{+0.003}_{-0.003}$, with colours consistent with moderately red TNO surfaces. No atmosphere or circum-object material is detected down to our sensitivity limits. The best-sampled event also allows a precise measurement of the angular diameter of the occulted star Gaia DR3 4056440205544338944, $\theta_\star = 0.670 \pm 0.010$ mas.

astro-ph.EP

Threshold $J/\psi$ Photoproduction as a Probe of Nuclear Gluon Structure

The nuclear EMC effect is the observation that quark distributions in bound nucleons experience significant modification at large $x$ relative to free nucleons. Despite decades of measurements verifying the presence of this effect in quarks across a wide range of nuclei, behavior of large-$x$ gluons in nuclei remains almost completely unknown. As the nuclear physics community seeks out new observables to try to elucidate the mechanisms behind the EMC effect, it becomes striking that we remain ignorant regarding the impact of nuclear effects on gluonic behavior. Recent photonuclear data using the Hall D photon beam have enabled the first measurement of $J/\psi$ photoproduction from nuclei near and below the energy threshold, with the results highlighted in Physical Review Letters as an Editors' Suggestion. These data have placed the first, and currently only, constraints on the behavior of large-$x$ gluons within bound nucleons. However, compared to the quantity of data which currently informs our knowledge of the quark-sector EMC effect, these data are extremely limited, and remain unable to conclusively observe or exclude large modification of gluon distributions. A high-luminosity photonuclear experiment will enable a precision measurement of incoherent $J/\psi$ photoproduction at and below the threshold region. This data will provide the first stringent constraints on nuclear modification of gluon structure or other exotic effects which could impact the production of $J/\psi$ from nuclei. We request 85 PAC days at Hall D using the GlueX detector with a 12 GeV electron beam energy and a coherent photon peak energy of $8$ GeV, split into 80 days using a $^4$He target and 5 calibration days using a $^2$H target.

nucl-ex

Asteroid sizes determined with thermophysical model and stellar occultations

Context. The sizes of many asteroids, especially slowly rotating, low-amplitude targets, remain poorly constrained due to selection effects. These biases limit the availability of high-quality data, leaving size estimates reliant on spherical shape assumptions. Such approximations introduce significant uncertainties propagating, e.g. into density determinations or thermophysical and compositional studies, affecting our understanding of asteroid properties. Aims. This work targets poorly studied main-belt asteroids, most of which lacked shape models. Using only high-quality dense light curves, thermal IR observations (incl. WISE), and stellar occultations, we aimed to produce reliable shape models and scale them via two independent techniques, allowing size comparison. We conducted two campaigns to obtain dense photometric light curves and to acquire multi-chord stellar occultations. Methods. Shape and spin models were reconstructed using lightcurve inversion. Sizes were determined by (1) thermophysical modeling with the Convex Inversion Thermophysical Model (CITPM), optimizing spin and shape models to visible lightcurve and IR data, and (2) scaling shape models with stellar occultations. Results. We obtained precise sizes and shape models for 15 asteroids. CITPM- and occultation-derived sizes agree within 5% in most cases, demonstrating the modeling's reliability. Larger discrepancies usually stem from incomplete occultation chord coverage. The study also gives insights into surface properties incl. albedo, roughness and thermal inertia. Conclusions. Using high-quality data and an advanced TPM integrating thermal and visible data with shape adjustment enabled precise size estimates comparable to those from multi-chord stellar occultations. We resolved major inconsistencies in previous size estimates, providing solid input for future studies on asteroid densities and surfaces.

astro-ph.EP

Acceptance tests of Hamamatsu R7081 photomultiplier tubes

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around 100 PMTs to measure the response of different media suitable for rare event searches. A subset of low-radioactivity 10-inch Hamamatsu R7081 PMTs were tested, characterised, and compared to manufacture certification. This manuscript describes the laboratory tests and analysis of gain, peak-to-valley ratio and dark rate of the PMTs to give an understanding of the charge response, signal-to-noise ratio and dark noise background as an acceptance test of the suitability of these PMTs for water-based detectors. Following the evaluation of these tests, the PMT performance agreed with the manufacturer specifications. These results are imperative for modeling the PMT response in detector simulations and providing confidence in the performance of the devices once installed in the detector underground.

physics.ins-det

Proposed large scale monolithic fused silica mirror suspension for 3rd generation gravitational wave detectors

Thermal noise from the suspension fibres used in the mirror pendulums in current gravitational wave detectors is a critical noise source. Future detectors will require improved suspension performance with the specific ability to suspend much heavier masses to reduce radiation pressure noise, whilst retaining good thermal noise performance. In this letter, we propose and experimentally demonstrate a design for a large-scale fused silica suspension, demonstrating its suitability for holding an increased mass of 160 kg. We demonstrate the concepts for improving thermal noise via longer suspension fibres supporting a higher static stress. We present a full thermal noise analysis of our prototype, meeting requirements for conceptual 3rd generation detector designs such as the high frequency interferometer of the Einstein Telescope (ET-HF), and closely approaching that required for Cosmic Explorer (CE).

astro-ph.IM

Stellar occultations enable milliarcsecond astrometry for Trans-Neptunian objects and Centaurs

Trans-Neptunian objects (TNOs) and Centaurs are remnants of our planetary system formation, and their physical properties have invaluable information for evolutionary theories. Stellar occultation is a ground-based method for studying these small bodies and has presented exciting results. These observations can provide precise profiles of the involved body, allowing an accurate determination of its size and shape. The goal is to show that even single-chord detections of TNOs allow us to measure their milliarcsecond astrometric positions in the reference frame of the Gaia second data release (DR2). Accurated ephemerides can then be generated, allowing predictions of stellar occultations with much higher reliability. We analyzed data from stellar occultations to obtain astrometric positions of the involved bodies. The events published before the Gaia era were updated so that the Gaia DR2 catalog is the reference. Previously determined sizes were used to calculate the position of the object center and its corresponding error with respect to the detected chord and the International Celestial Reference System (ICRS) propagated Gaia DR2 star position. We derive 37 precise astrometric positions for 19 TNOs and 4 Centaurs. Twenty-one of these events are presented here for the first time. Although about 68\% of our results are based on single-chord detection, most have intrinsic precision at the submilliarcsecond level. Lower limits on the diameter and shape constraints for a few bodies are also presented as valuable byproducts. Using the Gaia DR2 catalog, we show that even a single detection of a stellar occultation allows improving the object ephemeris significantly, which in turn enables predicting a future stellar occultation with high accuracy. Observational campaigns can be efficiently organized with this help, and may provide a full physical characterization of the involved object.

astro-ph.EP

A primary electron beam facility at CERN -- eSPS Conceptual design report

The design of a primary electron beam facility at CERN is described. The study has been carried out within the framework of the wider Physics Beyond Colliders study. It re-enables the Super Proton Synchrotron (SPS) as an electron accelerator, and leverages the development invested in Compact Linear Collider (CLIC) technology for its injector and as an accelerator research and development infrastructure. The facility would be relevant for several of the key priorities in the 2020 update of the European Strategy for Particle Physics, such as an electron-positron Higgs factory, accelerator R\&D, dark sector physics, and neutrino physics. In addition, it could serve experiments in nuclear physics. The electron beam delivered by this facility would provide access to light dark matter production significantly beyond the targets predicted by a thermal dark matter origin, and for natures of dark matter particles that are not accessible by direct detection experiments. It would also enable electro-nuclear measurements crucial for precise modelling the energy dependence of neutrino-nucleus interactions, which is needed to precisely measure neutrino oscillations as a function of energy. The implementation of the facility is the natural next step in the development of X-band high-gradient acceleration technology, a key technology for compact and cost-effective electron/positron linacs. It would also become the only facility with multi-GeV drive bunches and truly independent electron witness bunches for plasma wakefield acceleration. A second phase capable to deliver positron witness bunches would make it a complete facility for plasma wakefield collider studies. [...]

physics.acc-ph

Parity-Violating Inelastic Electron-Proton Scattering at Low $Q^2$ Above the Resonance Region

We report the measurement of the parity-violating asymmetry for the inelastic scattering of electrons from the proton, at $Q^2 = 0.082$ GeV$^2$ and $ W = 2.23$ GeV, above the resonance region. The result $A_{\rm Inel} = - 13.5 \pm 2.0 ({\rm stat}) \pm 3.9 ({\rm syst})$~ppm agrees with theoretical calculations, and helps to validate the modeling of the $\gamma Z$ interference structure functions $F_1^{\gamma Z}$ and $F_2^{\gamma Z}$ used in those calculations, which are also used for determination of the two-boson exchange box diagram ($\Box_{\gamma Z}$) contribution to parity-violating elastic scattering measurements. A positive parity-violating asymmetry for inclusive $\pi^-$ production was observed, as well as positive beam-normal single-spin asymmetry for scattered electrons and a negative beam-normal single-spin asymmetry for inclusive $\pi^-$ production.

nucl-ex

Precision Measurement of the Weak Charge of the Proton

The fields of particle and nuclear physics have undertaken extensive programs to search for evidence of physics beyond that explained by current theories. The observation of the Higgs boson at the Large Hadron Collider completed the set of particles predicted by the Standard Model (SM), currently the best description of fundamental particles and forces. However, the theory's limitations include a failure to predict fundamental parameters and the inability to account for dark matter/energy, gravity, and the matter-antimater asymmetry in the universe, among other phenomena. Given the lack of additional particles found so far through direct searches in the post-Higgs era, indirect searches utilizing precise measurements of well predicted SM observables allow highly targeted alternative tests for physics beyond the SM. Indirect searches have the potential to reach mass/energy scales beyond those directly accessible by today's high-energy accelerators. The value of the weak charge of the proton Q_W^p is an example of such an indirect search, as it sets the strength of the proton's interaction with particles via the well-predicted neutral electroweak force. Parity violation (invariance under spatial inversion (x,y,z) -> (-x,-y,-z)) is violated only in the weak interaction, thus providing a unique tool to isolate the weak interaction in order to measure the proton's weak charge. Here we report Q_W^p=0.0719+-0.0045, as extracted from our measured parity-violating (PV) polarized electron-proton scattering asymmetry, A_ep=-226.5+-9.3 ppb. Our value of Q_W^p is in excellent agreement with the SM, and sets multi-TeV-scale constraints on any semi-leptonic PV physics not described within the SM.

nucl-ex

Improving astrophysical parameter estimation via offline noise subtraction for Advanced LIGO

The Advanced LIGO detectors have recently completed their second observation run successfully. The run lasted for approximately 10 months and lead to multiple new discoveries. The sensitivity to gravitational waves was partially limited by correlated noise. Here, we utilize auxiliary sensors that witness these correlated noise sources, and use them for noise subtraction in the time domain data. This noise and line removal is particularly significant for the LIGO Hanford Observatory, where the improvement in sensitivity is greater than 20%. Consequently, we were also able to improve the astrophysical estimation for the location, masses, spins and orbital parameters of the gravitational wave progenitors.

astro-ph.IM

Calibrating chemical multisensory devices for real world applications: An in-depth comparison of quantitative Machine Learning approaches

Chemical multisensor devices need calibration algorithms to estimate gas concentrations. Their possible adoption as indicative air quality measurements devices poses new challenges due to the need to operate in continuous monitoring modes in uncontrolled environments. Several issues, including slow dynamics, continue to affect their real world performances. At the same time, the need for estimating pollutant concentrations on board the devices, espe- cially for wearables and IoT deployments, is becoming highly desirable. In this framework, several calibration approaches have been proposed and tested on a variety of proprietary devices and datasets; still, no thorough comparison is available to researchers. This work attempts a benchmarking of the most promising calibration algorithms according to recent literature with a focus on machine learning approaches. We test the techniques against absolute and dynamic performances, generalization capabilities and computational/storage needs using three different datasets sharing continuous monitoring operation methodology. Our results can guide researchers and engineers in the choice of optimal strategy. They show that non-linear multivariate techniques yield reproducible results, outperforming lin- ear approaches. Specifically, the Support Vector Regression method consistently shows good performances in all the considered scenarios. We highlight the enhanced suitability of shallow neural networks in a trade-off between performance and computational/storage needs. We confirm, on a much wider basis, the advantages of dynamic approaches with respect to static ones that only rely on instantaneous sensor array response. The latter have been shown to be best choice whenever prompt and precise response is needed.

cs.AI

Beam Instrumentation and Long-Range Beam-Beam Compensation

Chapter 13 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary Design Report. The Large Hadron Collider (LHC) is one of the largest scientific instruments ever built. Since opening up a new energy frontier for exploration in 2010, it has gathered a global user community of about 7,000 scientists working in fundamental particle physics and the physics of hadronic matter at extreme temperature and density. To sustain and extend its discovery potential, the LHC will need a major upgrade in the 2020s. This will increase its luminosity (rate of collisions) by a factor of five beyond the original design value and the integrated luminosity (total collisions created) by a factor ten. The LHC is already a highly complex and exquisitely optimised machine so this upgrade must be carefully conceived and will require about ten years to implement. The new configuration, known as High Luminosity LHC (HL-LHC), will rely on a number of key innovations that push accelerator technology beyond its present limits. Among these are cutting-edge 11-12 tesla superconducting magnets, compact superconducting cavities for beam rotation with ultra-precise phase control, new technology and physical processes for beam collimation and 300 metre-long high-power superconducting links with negligible energy dissipation. The present document describes the technologies and components that will be used to realise the project and is intended to serve as the basis for the detailed engineering design of HL-LHC.

physics.acc-ph

Effects of transients in LIGO suspensions on searches for gravitational waves

This paper presents an analysis of the transient behavior of the Advanced LIGO suspensions used to seismically isolate the optics. We have characterized the transients in the longitudinal motion of the quadruple suspensions during Advanced LIGO's first observing run. Propagation of transients between stages is consistent with modelled transfer functions, such that transient motion originating at the top of the suspension chain is significantly reduced in amplitude at the test mass. We find that there are transients seen by the longitudinal motion monitors of quadruple suspensions, but they are not significantly correlated with transient motion above the noise floor in the gravitational wave strain data, and therefore do not present a dominant source of background noise in the searches for transient gravitational wave signals.

astro-ph.IM

Quantum correlation measurements in interferometric gravitational wave detectors

Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational wave detectors, such as the Advanced Laser Interferometer Gravitational wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer for the first time.

physics.optics

A novel comparison of M{\o}ller and Compton electron-beam polarimeters

We have performed a novel comparison between electron-beam polarimeters based on M{\o}ller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $\mu$A) during the $Q_{\rm weak}$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $\mu$A) operation of the Compton polarimeter. All measurements were found to be consistent within experimental uncertainties of 1% or less, demonstrating that electron polarization does not depend significantly on the beam current. This result lends confidence to the common practice of applying M{\o}ller measurements made at low beam currents to physics experiments performed at higher beam currents. The agreement between two polarimetry techniques based on independent physical processes sets an important benchmark for future precision asymmetry measurements that require sub-1% precision in polarimetry.

physics.ins-det

Introduction to Beam Instrumentation and Diagnostics

These lectures aim to describe instruments and methods used for measuring beam parameters in particle accelerators. Emphasis will be given to new detection and analysis techniques in each field of accelerator instrumentation. A clear distinction is made between 'instrumentation', the design and construction of the instruments themselves, and 'diagnostics', the use of the data from these instruments for running and improving the performance of the accelerator.

physics.acc-ph

Precision Electron-Beam Polarimetry using Compton Scattering at 1 GeV

We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micro-strip detector which was able to capture most of the spectrum of scattered electrons. The data analysis technique exploited track finding, the high granularity of the detector and its large acceptance. The polarization of the $180~\mu$A, $1.16$~GeV electron beam was measured with a statistical precision of $<$~1\% per hour and a systematic uncertainty of 0.59\%. This exceeds the level of precision required by the \qweak experiment, a measurement of the vector weak charge of the proton. Proposed future low-energy experiments require polarization uncertainty $<$~0.4\%, and this result represents an important demonstration of that possibility. This measurement is also the first use of diamond detectors for particle tracking in an experiment.

nucl-ex

The Q_weak Experimental Apparatus

The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.

physics.ins-det