arXiv ScienceSearch

arXiv subjects

R. Bates

Publications and source records attributed to R. Bates.

13 recordsLinked to original sources

Testbeam characterization of a 3D silicon sensor read out by Timepix4

Testbeam results from a $300\,\mu\mathrm{m}$-thick 3D silicon sensor bump-bonded to a Timepix4 ASIC, are presented. The hit detection efficiency, spatial resolution, and timing performance of the 3D sensor are studied for several track angles, bias voltages and charge thresholds. The time measurements are corrected for Timepix4 clock-frequency variations and timewalk, while for the spatial studies, nonlinear charge-sharing corrections are determined. At perpendicular incidence, the time resolution of the 3D detector is equal to $245\,\mathrm{ps}$ with a $97\%$ hit detection efficiency. An optimal angle of $8^\circ$ with respect to the beam direction of the 3D detector was found, in which the time resolution improves by $6\%$ compared to normal incidence, while the hit detection efficiency reaches above $99\%$ and the spatial resolution is approximately $7\,\mu\mathrm{m}$. Intrapixel studies show that a time resolution of $153\,\mathrm{ps}$ at the most probable value of the signal charge can be achieved for hits between the electrodes at normal incidence, while the timing performance of these best-performing regions deteriorate upon sensor rotation. The timing properties at different depths of the 3D sensor have been investigated with tracks at grazing-angle incidence, revealing a dependence of the time resolution along the sensor depth.

physics.ins-det

Pixel column issue in the ATLAS Inner Tracker modules

Pixel modules are currently being built for the ATLAS ITk Pixel detector upgrade. During the preproduction phase, recurring chip malfunctioning was observed during electrical testing. It was possible to bypass this issue by disabling some pixel core columns in the ITkPix readout chip. Therefore the issue is called "core column issue" which is a direct disqualifier for a pixel module. A concerning number of cases has been observed in pixel modules with ITkPix v1.1 as well as v2 chips which significantly impacts the module yield. However, the behaviour is erratic and there is not any evidence hinting at the origin of this issue. These proceedings outline the investigations of the issue, highlighting the electrical behaviour during testing, present findings from the data collected via our production database and through visual inspection, and point towards possible causes of the issue.

physics.ins-det

26.5 ps Time Resolution Using 50 {\mu}m Low Gain Avalanche Detectors Fabricated by Micron Semiconductor Ltd

Low Gain Avalanche Detectors (LGADs) are silicon semiconductor sensors with an implanted thin p-doped multiplication layer that is designed to provide low gain. Most importantly, LGADs are specifically engineered to provide excellent spatial and temporal resolution simultaneously. The technology shows promising prospects of fulfilling the 4D tracking requirements of future high energy physics experiments. Micron Semiconductor Ltd. has fabricated LGADs with an active thickness of 50 $\mu$m. The electrical and timing performance has been measured and compared with devices fabricated at IMB-CNM for reference. 50 $\mu$m thin LGADs by Micron Semiconductor Ltd. were measured to have a timing resolution in the region of 30 ps using a dedicated setup involving minimum ionising particles produced by Sr-90. Specifically, the best timing resolution of 26.5 ps was measured at a bias voltage of 200 V at -30{\deg}C.

physics.ins-det

Timing measurements with a 3D silicon sensor on Timepix3 in a 180 GeV/c hadron beam

Test beam measurements have been carried out with a 3D sensor on a Timepix3 ASIC and the time measurements are presented. The measurements are compared to those of a thin planar sensor on Timepix3. It is shown that for a perpendicularly incident beam the time resolution of both detectors is dominated by the Timepix3 front-end. The 3D detector is dominated by the time-to-digital conversion whereas the analog front-end jitter also gives a significant contribution for the thin planar detector. The 3D detector reaches an overall time resolution of 567(6)ps compared to 683(8)ps for the thin planar detector. For a grazing angle beam, however, the thin planar detector achieves a better time resolution because it has a lower pixel capacitance, and therefore suffers less from jitter in the analog front-end for the low charge signals that mainly occur in this type of measurement. Finally, it is also shown that the 3D and thin planar detector can achieve time resolutions for large clusters of about 100ps and 250ps, respectively, by combining many single hit measurements.

physics.ins-det

Production and Integration of the ATLAS Insertable B-Layer

During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.

physics.ins-det

Quadratic Hyperbolicity Preservers & Multiplier Sequences

It is known (see \cite[Br\"and\'en, Lemma 2.7]{B10}) that a necessary condition for $T:=\sum Q_k(x) D^k$ to be hyperbolicity preserving is that $Q_k(x)$ and $Q_{k-1}(x)$ have interlacing zeros. We characterize all quadratic linear operators, as a consequence we find several classes of $P_n$-multiplier sequence.

math.CV

Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors

Precision sound velocity measurements can simultaneously determine binary gas composition and flow. We have developed an analyzer with custom electronics, currently in use in the ATLAS inner detector, with numerous potential applications. The instrument has demonstrated ~0.3% mixture precision for C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and high flow versions of the instrument have demonstrated flow resolutions of +/- 2% F.S. for flows up to 250 l.min-1, and +/- 1.9% F.S. for linear flow velocities up to 15 ms-1; the latter flow approaching that expected in the vapour return of the thermosiphon fluorocarbon coolant recirculator being built for the ATLAS silicon tracker.

physics.ins-det

A combined ultrasonic flow meter and binary vapour mixture analyzer for the ATLAS silicon tracker

An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) evaporative coolant to a blend containing 10-25% of C2F6 (hexafluoro-ethane). Such a change will reduce the evaporation temperature to assure thermal stability following radiation damage accumulated at full LHC luminosity. Central to this upgrade is a new ultrasonic instrument in which sound transit times are continuously measured in opposite directions in flowing gas at known temperature and pressure to deduce the C3F8/C2F6 flow rate and mixture composition. The instrument and its Supervisory, Control and Data Acquisition (SCADA) software are described in this paper. Several geometries for the instrument are in use or under evaluation. An instrument with a pinched axial geometry intended for analysis and measurement of moderate flow rates has demonstrated a mixture resolution of 3.10-3 for C3F8/C2F6 molar mixtures with 20%C2F6, and a flow resolution of 2% of full scale for mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher mixture precision is possible: a sensitivity of <5.10-5 to leaks of C3F8 into part of the ATLAS tracker nitrogen envelope (mw difference 160) has been seen. An instrument with an angled sound path geometry has been developed for use at high fluorocarbon mass flow rates of around 1.2 kgs-1 - corresponding to full flow in a new 60kW thermosiphon recirculator under construction for the ATLAS silicon tracker. Extensive computational fluid dynamics studies were performed to determine the preferred geometry (ultrasonic transducer spacing and placement, together with the sound crossing angle with respect to the vapour flow direction). A prototype with 45deg crossing angle has demonstrated a flow resolution of 1.9% of full scale for linear flow velocities up to 15 ms-1. The instrument has many potential applications.

physics.ins-det

A Combine On-Line Acoustic Flowmeter and Fluorocarbon Coolant Mixture Analyzer for The ATLAS Silicon Tracker

An upgrade to the ATLAS silicon tracker cooling control system may require a change from C3F8 (octafluoro-propane) to a blend containing 10-30% of C2F6 (hexafluoro-ethane) to reduce the evaporation temperature and better protect the silicon from cumulative radiation damage with increasing LHC luminosity. Central to this upgrade is a new acoustic instrument for the real-time measurement of the C3F8/C2F6 mixture ratio and flow. The instrument and its Supervisory, Control and Data Acquisition (SCADA) software are described in this paper. The instrument has demonstrated a resolution of 3.10-3 for C3F8/C2F6 mixtures with ~20%C2F6, and flow resolution of 2% of full scale for mass flows up to 30gs-1. In mixtures of widely-differing molecular weight (mw), higher mixture precision is possible: a sensitivity of < 5.10-4 to leaks of C3F8 into the ATLAS pixel detector nitrogen envelope (mw difference 160) has been seen. The instrument has many potential applications, including the analysis of mixtures of hydrocarbons, vapours for semi-conductor manufacture and anaesthesia.

physics.acc-ph

Test Beam Results of 3D Silicon Pixel Sensors for the ATLAS upgrade

Results on beam tests of 3D silicon pixel sensors aimed at the ATLAS Insertable-B-Layer and High Luminosity LHC (HL-LHC)) upgrades are presented. Measurements include charge collection, tracking efficiency and charge sharing between pixel cells, as a function of track incident angle, and were performed with and without a 1.6 T magnetic field oriented as the ATLAS Inner Detector solenoid field. Sensors were bump bonded to the front-end chip currently used in the ATLAS pixel detector. Full 3D sensors, with electrodes penetrating through the entire wafer thickness and active edge, and double-sided 3D sensors with partially overlapping bias and read-out electrodes were tested and showed comparable performance.

physics.ins-det

Can Prosody Aid the Automatic Classification of Dialog Acts in Conversational Speech?

Identifying whether an utterance is a statement, question, greeting, and so forth is integral to effective automatic understanding of natural dialog. Little is known, however, about how such dialog acts (DAs) can be automatically classified in truly natural conversation. This study asks whether current approaches, which use mainly word information, could be improved by adding prosodic information. The study is based on more than 1000 conversations from the Switchboard corpus. DAs were hand-annotated, and prosodic features (duration, pause, F0, energy, and speaking rate) were automatically extracted for each DA. In training, decision trees based on these features were inferred; trees were then applied to unseen test data to evaluate performance. Performance was evaluated for prosody models alone, and after combining the prosody models with word information -- either from true words or from the output of an automatic speech recognizer. For an overall classification task, as well as three subtasks, prosody made significant contributions to classification. Feature-specific analyses further revealed that although canonical features (such as F0 for questions) were important, less obvious features could compensate if canonical features were removed. Finally, in each task, integrating the prosodic model with a DA-specific statistical language model improved performance over that of the language model alone, especially for the case of recognized words. Results suggest that DAs are redundantly marked in natural conversation, and that a variety of automatically extractable prosodic features could aid dialog processing in speech applications.

cs.CL

Dialogue Act Modeling for Automatic Tagging and Recognition of Conversational Speech

We describe a statistical approach for modeling dialogue acts in conversational speech, i.e., speech-act-like units such as Statement, Question, Backchannel, Agreement, Disagreement, and Apology. Our model detects and predicts dialogue acts based on lexical, collocational, and prosodic cues, as well as on the discourse coherence of the dialogue act sequence. The dialogue model is based on treating the discourse structure of a conversation as a hidden Markov model and the individual dialogue acts as observations emanating from the model states. Constraints on the likely sequence of dialogue acts are modeled via a dialogue act n-gram. The statistical dialogue grammar is combined with word n-grams, decision trees, and neural networks modeling the idiosyncratic lexical and prosodic manifestations of each dialogue act. We develop a probabilistic integration of speech recognition with dialogue modeling, to improve both speech recognition and dialogue act classification accuracy. Models are trained and evaluated using a large hand-labeled database of 1,155 conversations from the Switchboard corpus of spontaneous human-to-human telephone speech. We achieved good dialogue act labeling accuracy (65% based on errorful, automatically recognized words and prosody, and 71% based on word transcripts, compared to a chance baseline accuracy of 35% and human accuracy of 84%) and a small reduction in word recognition error.

cs.CL

Preliminary Results for LP VPE X-Ray Detectors

Thick epitaxial layers have been grown using Low Pressure Vapour Phase Epitaxy techniques with low free carrier concentrations . This type of material is attractive as a medium for X-ray detection, because of its high conversion efficiency for X-rays in the medically interesting energy range.

physics.ins-det