arXiv ScienceSearch

arXiv subjects

R. Adams

Publications and source records attributed to R. Adams.

8 recordsLinked to original sources

A 2D pixelated stilbene scintillator detector array for simultaneous radiography with fast neutrons and gammas

For radiography applications using fast neutrons simultaneously with gammas we have developed a detector with 16 stilbene crystals in a 4$\times$4 2D array with a 5~mm pitch and a depth of 25~mm. The crystal array is read out by Silicon photomultipliers and custom signal processing electronics. The detector prototype was tested using a custom D-D fast neutron generator at the Paul Scherrer Institute. By applying a pulse shape discrimination algorithm the detector is able to detect and distinguish fast neutrons and gammas simultaneously. Various attenuating samples placed between the source and detector with different materials and thicknesses were tested and the measured macroscopic fast neutron cross sections were compared to what was expected. Deviations were studied with the help of detailed Geant4 simulations. The detection efficiency for D-D fast neutrons was measured to be around 10\%.

physics.ins-det

High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel

We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 millisecond exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.

physics.ins-det

First studies of electron transport along small gas gaps of novel foil radiation converters for fast-neutron detectors

Novel high efficiency fast-neutron detectors were suggested for fan-beam tomography applications. They combine multi-layer polymer converters in gas medium, coupled to thick gaseous electron multipliers (THGEM). In this work we discuss the results of a systematic study of the electron transport inside a narrow gap between successive converter foils, which affects the performance of the detector, both in terms of detection efficiency and localization properties. The efficiency of transporting ionization electrons was measured along a 0.6 mm wide gas gap in 6 and 10 mm wide polymer converters Computer simulations provided conceptual understanding of the observations. For a drift lengths of 6 mm electrons were efficiently transported along the narrow gas gap, with minimal diffusion-induced losses; an average collection efficiency of 95% was achieved for the ionization electrons induced by a primary electron of a few keV initial energy. The 10 mm height converter yielded considerably lower efficiency due to electrical and mechanical flaws of the converter foils. The results indicate that detection efficiencies of around 7% can be expected for 2.5 MeV neutrons with 300 foils converters, of 6 mm height, 0.4 mm thick foils and 0.6 mm gas gap.

physics.ins-det

Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications

The conceptual design and operational principle of a novel high-efficiency, fast neutron imaging detector based on THGEM, intended for future fan-beam transmission tomography applications, is described. We report on a feasibility study based on theoretical modeling and computer simulations of a possible detector configuration prototype. In particular we discuss results regarding the optimization of detector geometry, estimation of its general performance, and expected imaging quality: it has been estimated that detection efficiency of around 5-8% can be achieved for 2.5MeV neutrons; spatial resolution is around one millimeter with no substantial degradation due to scattering effects. The foreseen applications of the imaging system are neutron tomography in non-destructive testing for the nuclear energy industry, including examination of spent nuclear fuel bundles, detection of explosives or drugs, as well as investigation of thermal hydraulics phenomena (e.g., two-phase flow, heat transfer, phase change, coolant dynamics, and liquid metal flow).

physics.ins-det

Noncoaxial multivortices in the complex sine-Gordon theory on the plane

We construct explicit multivortex solutions for the complex sine-Gordon equation (the Lund-Regge model) in two Euclidean dimensions. Unlike the previously found (coaxial) multivortices, the new solutions comprise $n$ single vortices placed at arbitrary positions (but confined within a finite part of the plane.) All multivortices, including the single vortex, have an infinite number of parameters. We also show that, in contrast to the coaxial complex sine-Gordon multivortices, the axially-symmetric solutions of the Ginzburg-Landau model (the stationary Gross-Pitaevskii equation) {\it do not} belong to a broader family of noncoaxial multivortex configurations.

nlin.SI

Precision Pion-Proton Elastic Differential Cross Sections at Energies Spanning the Delta Resonance

A precision measurement of absolute pi+p and pi-p elastic differential cross sections at incident pion laboratory kinetic energies from T_pi= 141.15 to 267.3 MeV is described. Data were obtained detecting the scattered pion and recoil proton in coincidence at 12 laboratory pion angles from 55 to 155 degrees for pi+p, and six angles from 60 to 155 degrees for pi-p. Single arm measurements were also obtained for pi+p energies up to 218.1 MeV, with the scattered pi+ detected at six angles from 20 to 70 degrees. A flat-walled, super-cooled liquid hydrogen target as well as solid CH2 targets were used. The data are characterized by small uncertainties, ~1-2% statistical and ~1-1.5% normalization. The reliability of the cross section results was ensured by carrying out the measurements under a variety of experimental conditions to identify and quantify the sources of instrumental uncertainty. Our lowest and highest energy data are consistent with overlapping results from TRIUMF and LAMPF. In general, the Virginia Polytechnic Institute SM95 partial wave analysis solution describes our data well, but the older Karlsruhe-Helsinki PWA solution KH80 does not.

nucl-ex

Preliminary Results for LP VPE X-Ray Detectors

Thick epitaxial layers have been grown using Low Pressure Vapour Phase Epitaxy techniques with low free carrier concentrations . This type of material is attractive as a medium for X-ray detection, because of its high conversion efficiency for X-rays in the medically interesting energy range.

physics.ins-det

Characterisation of low pressure VPE GaAs diodes before and after 24 GeV/c proton irradiation

GaAs Schottky diode detectors have been fabricated upon Low Pressure Vapour Phase Epitaxial GaAs. The devices were characterised before and after a $1.25 \times 10^{14}$~cm$^{-2}$ 24GeV/c proton fluence. The as fabricated Ti-GaAs barrier height was measured, via two electrical methods, to be $0.81\pm0.005$ and $0.85\pm0.01$~eV and a space charge density of $2.8 \pm 0.2 \times 10^{14}$~cm$^{-3}$ was determined. The current was greater than that expected for an ideal barrier with the excess attributed to generation current from the bulk. The charge collection efficiency, determined from front alpha illumination and 60 keV gamma irradiation, was inexcess of 95% at 50V reverse bias. After irradiation the reverse current, measured for a bias of 200V at 20$^{o}$~C, increased from 90~nA to 1500~nA due to radiation induced generation centres. Deep levels were showed to be present using capacitance techniques. The charge collection of the device determined from front alpha illumination fell to $32\pm5$% at a reverse bias of 200V.

physics.ins-det