arXiv Science⌕ Search

arXiv subjects

Quang Manh Hoang

Publications and source records attributed to Quang Manh Hoang.

7 recordsLinked to original sources

Conflict-Aware Impedance-Sensitivity-Based Tuning for Multi-Mode Damping Enhancement

Impedance-based eigenvalue sensitivity provides a practical way to relate converter parameters to poorly damped system modes, but tuning becomes nontrivial when one parameter improves one target mode while degrading another. This paper introduces a conflict-aware tuning strategy for simultaneous damping enhancement of multiple modes. The method converts impedance-derived eigenvalue sensitivities into normalized damping-ratio sensitivities, diagnoses opposing modal tuning directions, and selects either one parameter or a coordinated pair at each iteration. A low-dimensional max--min problem maximizes the predicted damping of the worst target mode subject to parameter limits, protected-mode constraints, and implementation-specific feasibility requirements. Each accepted update is verified on the full system model and the sensitivities are recomputed. Studies on a four-bus system and a modified IEEE 14-bus system demonstrate the value of pairwise coordination, including a case in which single-parameter tuning stops before the predefined damping target is reached.

eess.SY↗

Adaptive Grid-Mode-Aware Hybrid Energy Storage Control for AI Data Center Oscillation Mitigation

Oscillatory power components in AI data-center demand can produce large frequency deviations when they coincide with vulnerable grid modes. Mode-aware hybrid energy storage systems (HESSs) can selectively suppress these components, but their effectiveness degrades when the grid mode changes while the control target remains fixed. This paper proposes a closed-loop grid-mode-adaptive HESS control framework that integrates measurement-based modal identification with mode-selective control. A sliding-window N4SID estimator identifies the local grid dynamics from grid-side power and frequency measurements, and the resulting natural-frequency estimate is used to retune the modal suppression branch assigned to the supercapacitor. The framework is evaluated under a grid-mode shift from 0.50 to 1.35Hz while maintaining equal physical damping and approximately equal load excitation at both frequencies. Compared with the fixed-target controller, the adaptive method reduces the post-change grid-side modal power component from 8.78 to 2.02MW, corresponding to a 76.94% reduction, and substantially lowers the resulting frequency deviation.

eess.SY↗

Grid-Mode-Aware AI Data Center Power Smoothing via Bayesian-Optimized Hybrid Energy Storage System

AI data centers exhibit highly stochastic, volatile power demands from intensive workloads and synchronized GPU training cycles, which can excite grid natural frequencies and threaten system stability. This paper proposes a real-time, forecasting-independent control framework utilizing a Hybrid Energy Storage System (HESS) that coordinates a Battery Energy Storage System (BESS) and a supercapacitor (SC). Employing a parameterized frequency-decoupling and active modal-damping policy, the framework mitigates critical oscillatory load components while smoothing overall power fluctuations. To bypass the heavy computational burden of online receding-horizon optimization, this work introduces an offline Bayesian Optimization (BO) approach to optimally tune real-time control parameters, minimizing a multi-objective cost function that balances grid compliance penalties and storage degradation. Numerical simulations demonstrate that the proposed method ensures grid stability and strong target envelope adherence. Specifically, it reshapes extreme 75-160 MW raw demand fluctuations to largely fit within a tight 10 MW target band, with only brief transient excursions, while attenuating the critical 20 MW oscillatory component below 1 MW to suppress resonant excitation.

eess.SY↗

FedAvgIm: Federated Learning for Multi-Site Impedance Identification of Inverter-Based Resources

With the increasing integration of inverter-based resources (IBRs) into power systems, assessing small-signal interaction stability has become essential. Impedance/admittance models enable frequency-domain characterization of IBR dynamics without requiring access to proprietary internal control details, but measurement-based identification is time-consuming and must be repeated across operating points. This paper proposes FedAvgIm, a privacy-aware federated-learning framework for multi-site dq-admittance identification under severe local data scarcity and raw-data-locality constraints. Each IBR site trains a local feed-forward neural network using a small set of operating-point-frequency samples, while only model parameters are shared with a cloud aggregator that performs sample-size-weighted FedAvg to update a global model and broadcast it back to all sites. To demonstrate effectiveness, EMT measurement-based admittance datasets are constructed for nine grid-following IBRs with different parameters, architectures, measurement-noise levels, and non-IID settings, where each client has only 40-390 training samples. Results show that FedAvgIm achieves performance close to centralized training and consistently outperforms local-only learning and raw-data-locality-preserving transfer-learning baselines. Additional studies show that FedAvgIm maintains stable learning behavior under measurement noise and remains beneficial under moderate non-IID conditions. The estimated dq-admittance models are further applied to generalized Nyquist stability analysis and validated against EMT time-domain simulations under multiple operating points and grid-strength conditions.

eess.SY↗

Optimal Demand Response-Based Energy Management for Campus Buildings with Battery Energy Storage Systems: A Case Study of the ELB Building

Buildings account for a significant portion of global electricity consumption, making demand response (DR) an effective strategy for reducing energy costs and improving grid flexibility. This paper presents an optimal energy management framework for a campus building that integrates demand response and battery energy storage systems (BESS) to minimize electricity costs while satisfying operational constraints and occupant comfort requirements. The proposed optimization model schedules building loads and battery charging/discharging based on time-varying electricity prices and building demand profiles. The framework is validated using the Engineering Laboratory Building (ELB) at the University of Michigan-Dearborn as a real-world case study. Four operating scenarios are investigated: (i) baseline operation, (ii) demand response without battery energy storage, (iii) battery energy storage, and (iv) demand response with battery energy storage. Simulation results demonstrate that demand alone reduces the building's electricity cost by approximately 12% compared with conventional operation. When battery energy storage is incorporated, the total electricity cost reduction increases to approximately 26%, highlighting the significant economic benefits of coordinated demand response and energy storage scheduling. The results demonstrate that integrating battery energy storage with demand response substantially enhances the operational flexibility of campus buildings and provides an effective solution for cost-effective and sustainable building energy management.

eess.SY↗

Learning-Based Power Flow Estimation with Sparse PMU Deployment in Power Systems

Accurate monitoring of power flow is fundamental to the secure and reliable operation of modern power systems. Existing data-driven power flow estimation methods typically assume that synchronized measurements are available at every bus, requiring extensive deployment of phasor measurement units (PMUs). Such dense sensing infrastructures substantially increase installation, communication, and maintenance costs. This paper proposes a learning-based framework that minimizes the number of installed PMUs while maintaining high-accuracy systemwide power flow estimation. Instead of relying on measurements from all buses, the proposed method identifies an informative subset of buses whose synchronized measurements are sufficient to accurately reconstruct branch power flow across the network. To this end, a neural network is developed to learn the nonlinear relationship between PMU measurements and system-wide power flows, and multiple PMU deployment scenarios are evaluated to quantify the trade-off between measurement availability and estimation accuracy. The results enable utilities to identify cost-effective PMU placement strategies that balance deployment cost and prediction performance. Case studies on the IEEE 30-bus test system demonstrate that the proposed framework significantly reduces the number of required PMUs while maintaining accurate power flow estimation.

eess.SY↗

Scalable Impedance Identification of Diverse IBRs via Cluster-Specialized Neural Networks

Modern machine learning approaches typically identify the impedance of a single inverter-based resource (IBR) and assume similar impedance characteristics across devices. In modern power systems, however, IBRs will employ diverse control topologies and algorithms, leading to highly heterogeneous impedance behaviors. Training one model per IBR is inefficient and does not scale. This paper proposes a scalable impedance identification framework for diverse IBRs via cluster-specialized neural networks. First, the dataset is partitioned into multiple clusters with similar feature profiles using the K-means clustering method. Then, each cluster is assigned a specialized feed-forward neural network (FNN) tailored to its characteristics, improving both accuracy and computational efficiency. In deployment, only a small number of measurements are required to predict impedance over a wide range of operating points. The framework is validated on six IBRs with varying control bandwidths, control structures, and operating conditions, and further tested on a previously unseen IBR using only ten measurement points. The results demonstrate high accuracy in both the clustering and prediction stages, confirming the effectiveness and scalability of the proposed method.

eess.SY↗