arXiv Science⌕ Search

arXiv subjects

Pavlos P Vlachos

Publications and source records attributed to Pavlos P Vlachos.

2 recordsLinked to original sources

Color-Doppler Echocardiography Flow Field Velocity Reconstruction Using a Streamfunction -Vorticity Formulation

We introduce a new method, (Doppler Velocity Reconstruction or DoVeR), for reconstructing two-component velocity fields from color Doppler scans. DoVeR employs the streamfunction-vorticity equation, which satisfies mass conservation while accurately approximating the flow rate of rotation. We validated DoVeR using artificial color Doppler images generated from computational fluid dynamics models of left ventricle (LV) flow. We compare DoVeR against the conventional intraventricular Vector Flow Mapping (iVFM1D) and reformulated iVFM (iVFM2D). LV model error analysis showed DoVeR is more robust to noise and probe placement, with noise RMS errors (nRMSE) between 3.81%-6.67%, while the iVFM methods delivered 4.16%-24.17% for iVFM1D and 4.06%-400.21% for iVFM2D. We test the DoVeR and iVFM methods using in-vivo mouse-LV ultrasound scans. DoVeR yielded more hemodynamically accurate reconstructions, suggesting that it can provide a more reliable approach for robust quantification of cardiac flow.

physics.med-ph↗

Two Regime Cooling in Flow Induced by a Spark Discharge

The cooling process associated with the flow induced by a spark plasma discharge generated between a pair of electrodes is measured using stereoscopic particle image velocimetry (S-PIV) and background oriented schlieren (BOS). Density measurements show that the hot gas kernel initially cools fast by convective cooling, followed by a slower cooling process. The cooling rates during the fast regime range from being 2 to 10 times those in the slower regime. An analytical model is developed to relate the cooling observed in the fast regime from BOS, to the total entrainment of cold ambient fluid per unit volume of the hot gas kernel, measured from S-PIV. The model calculates the cooling ratio to characterize the cooling process and shows that the cooling ratio estimated from the density measurements are in close agreement with those calculated from the entrainment. These measurements represent the first ever quantitative density and velocity measurements of the flow induced by a spark discharge and reveal the role of entrainment on the cooling of the hot gas kernel. These results underscore that convective cooling of the hot gas kernel, in the fast regime, leads to approximately 50% of the cooling and occurs within the first millisecond of the induced flow.

physics.flu-dyn↗