arXiv ScienceSearch

arXiv subjects

Patrick Brun

Publications and source records attributed to Patrick Brun.

4 recordsLinked to original sources

Development of a Raman Lidar for the Southern Site of the Cherenkov Telescope Array Observatory

The future CTAO will reach a sensitivity and energy resolution never obtained until now by any other high-energy gamma-ray experiment. Studying the atmospheric conditions during the CTAO observations, namely the extinction and backscatter coefficients, permits a very precise evaluation of the atmospheric UV absorption, a parameter that directly affects the energy and flux spectra of the CTAO-studied sources. This paper describes the motivation for the LUPM Raman Lidar system, a Lidar specifically designed to fulfill the CTAO requirements for the south site in Chile. Preliminary results obtained during a two-year campaign at the OHP Observatory are presented. Our results include estimations of the extinction, back-scatter, and Lidar ratio at both 355 and 532 nm and confirm the conformity of our prototype to the CTAO requirements

astro-ph.IM

Design and characterization of the Flat-Field Calibration of the NectarCAM Camera

The NectarCAM flat-field flasher is a calibration device designed for the camera that will equip the Medium-Sized Telescopes (MSTs) of the northern site of the Cherenkov Telescope Array Observatory (CTAO). Positioned in the centre of the MST dish, 16 meters in front of the camera, the flasher emits short (FWHM $\approx$ 5 ns), uniform (2$-$4%) light pulses to illuminate the entire focal plane. Accurate calibration is crucial for the optimal operation of the NectarCAM, ensuring precise gain computation and mitigating differences in light-collection efficiency of the pixels of the camera. Using the flat-field flasher, two informations are obtained : the pixel gain and the relative efficiency between pixels. In addition, the flasher is used to probe the dynamic range over which the camera operates effectively. In this study, we report on the performance characterisation of the flat-field flasher using a dedicated test bench. We report on the results of tests conducted on several flasher units, evaluating their reliability. Furthermore, we describe how the flat-field coefficients are applied within the camera to ensure uniformity of response of few percent level across all 1855 pixels. As the deployment of the first MST at the CTAO northern site is scheduled for 2027, this work represents a significant contribution to the collaboration`s efforts to finalize camera calibration systems.

astro-ph.IM

Design and characterization of a single photoelectron calibration system for the NectarCAM camera of the medium-sized telescopes of the Cherenkov Telescope Array

In this work, we describe the optical properties of the single photoelectron (SPE) calibration system designed for NectarCAM, a camera proposed for the Medium Sized Telescopes (MST) of the Cherenkov Telescope Array (CTA). One of the goals of the SPE system, as integral part of the NectarCAM camera, consists in measuring with high accuracy the gain of its photo-detection chain. The SPE system is based on a white painted screen where light pulses are injected through a fishtail light guide from a dedicated flasher. The screen - placed 15 mm away from the focal plane - is mounted on an XY motorization that allows movements over all the camera plane. This allows in-situ measurements of the SPE spectra via a complete scan of the 1855 photo-multiplier tubes (PMTs) of NectarCAM. This calibration process will enable the reduction of the systematic uncertainties on the energy reconstruction of $\gamma$-rays coming from distant astronomical sources and detected by CTA.

astro-ph.IM

Raman LIDARs for the atmospheric calibration along the line-of-sight of CTA

The Cherenkov Telescope Array (CTA) is the next generation ground based observatory for gamma ray astronomy at very high energies. Employing more than 100 Imaging Atmospheric Cherenkov Telescopes in the northern and southern hemispheres, it was designed to reach unprecedented sensitivity and energy resolution. Understanding and correcting for systematic biases on the absolute energy scale and instrument response functions will be a crucial issue for the performance of CTA. The LUPM group and the Spanish/Italian/Slovenian collaboration are currently building two Raman LIDAR prototypes for the online atmospheric calibration along the line of sight of the CTA. Requirements for such a solution include the ability to characterize aerosol extinction at two wavelengths to distances of 30 km with an accuracy better than 5%, within time scales of about a minute, steering capabilities and close interaction with the CTA array control and data acquisition system as well as other auxiliary instruments. Our Raman LIDARs have design features that make them different from those used in atmospheric science and are characterized by large collecting mirrors (2.5 m2), liquid light guides that collect the light at the focal plane and transport it to the readout system, reduced acquisition time and highly precise Raman spectrometers. The Raman LIDARs will participate in a cross calibration and characterization campaign of the atmosphere at the CTA North site at La Palma, together with other site characterization instruments. After a one year test period there, an in depth evaluation of the solutions adopted by the two projects will lead to a final Raman LIDAR design proposal for both CTA sites.

astro-ph.IM