arXiv ScienceSearch

arXiv subjects

Pascal Spincemaille

Publications and source records attributed to Pascal Spincemaille.

At least 19 recordsLinked to original sources

Spectral Vision Transformer for Efficient Tokenization with Limited Data

We propose a novel spectral vision transformer architecture for efficient tokenization in limited data, with an emphasis on medical imaging. We outline convenient theoretical properties arising from the choice of basis including spatial invariance and optimal signal-to-noise ratio. We show reduced complexity arising from the spectral projection compared to spatial vision transformers. We show equitable or superior performance with a reduced number of parameters as compared to a variety of models including compact and standard vision transformers, convolutional neural networks with attention, shifted window transformers, multi-layer perceptrons, and logistic regression. We include simulated, public, and clinical data in our analysis and release our code at: \verb+github.com/agr78/spectralViT+.

cs.CV

QSM-RimDS: A detection and segmentation tool for paramagnetic rim lesions in multiple sclerosis

Paramagnetic rim lesions (PRLs) are an emerging biomarker in multiple sclerosis (MS). Manual identification and rim segmentation of PRLs on quantitative susceptibility mapping (QSM) images are time-consuming. Deep learning-based QSM-RimNet can provide automated PRL detection, but this method does not provide rim segmentation for microglial density quantification and requires precise QSM lesion masks. The purpose of this study is to develop a U-Net-based QSM-RimDS method for joint PRL detection and rim segmentation using readily available T2-weighted (T2W) fluid-attenuated inversion recovery (FLAIR) lesion masks. Two expert readers performed PRL classification and rim segmentation as the reference. Dice similarity coefficient (DSC) was used to assess the agreement between rim segmentation obtained by QSM-RimDS and the manual expert segmentation. The PRL detection performances of QSM-RimDS and QSM-RimNet were evaluated using receiver operating characteristic (ROC) and precision-recall (PR) plots in a five-fold cross validation. A total of 260 PRLs (3.3\%) and 7720 non-PRLs (96.7\%) were identified by the readers. Compared to the expert rim segmentation, QSM-RimDS provided a mean DSC of 0.57 \pm 0.02 with moderate to high agreement (DSC \leq 0.5) in 73.8pm 5.7\% of PRLs over five folds. QSM-RimDS produced better and more consistent detection performance with a mean area under curve (AUC) of 0.754 \pm 0.037 vs. 0.514 \pm 0.121 by QSM-RimNet (46.7\% improvement) on PR plots, and 0.956 \pm 0.034 vs. 0.908 \pm 0.073 (5.3\% improvement) on ROC plots. In conclusion, QSM-RimDS improves PRL detection accuracy compared to QSM-RimNet and unlike QSM-RimNet can provide reasonably accurate rim segmentation.

cs.CV

Implicit neural representation for free-breathing MR fingerprinting (INR-MRF): co-registered 3D whole-liver water T1, water T2, proton density fat fraction, and R2* mapping

Purpose: To develop an MRI technique for free-breathing 3D whole-liver quantification of water T1, water T2, proton density fat fraction (PDFF), R2*. Methods: An Eight-echo spoiled gradient echo pulse sequence with spiral readout was developed by interleaving inversion recovery and T2 magnetization preparation. We propose a neural network based on a 4D and a 3D implicit neural representation (INR) which simultaneously learns the motion deformation fields and the static reference frame MRI subspace images respectively. Water and fat singular images were separated during network training, with no need of performing retrospective water-fat separation. T1, T2, R2* and proton density fat fraction (PDFF) produced by the proposed method were validated in vivo on 10 healthy subjects, using quantitative maps generated from conventional scans as reference. Results: Our results showed minimal bias and narrow 95% limits of agreement on T1, T2, R2* and PDFF values in the liver compared to conventional breath-holding scans. Conclusions: INR-MRF enabled co-registered 3D whole liver T1, T2, R2* and PDFF mapping in a single free-breathing scan.

physics.med-ph

MRI quantification of liver fibrosis using diamagnetic susceptibility: An ex-vivo feasibility study

In chronic liver disease, liver fibrosis develops as excessive deposition of extracellular matrix macromolecules, predominantly collagens, progressively form fibrous scars that disrupt the hepatic architecture, and fibrosis, iron, and fat are interrelated. Fibrosis is the best predictor of morbidity and mortality in chronic liver disease but liver biopsy, the reference method for diagnosis and staging, is invasive and limited by sampling and interobserver variability and risks of complications. The overall objective of this study was to develop a new non-invasive method to quantify fibrosis using diamagnetic susceptibility sources with histology validation in ex vivo liver explants.

physics.med-ph

Deep learning improved autofocus for motion artifact reduction and its application in quantitative susceptibility mapping

Purpose: To develop a pipeline for motion artifact correction in mGRE and quantitative susceptibility mapping (QSM). Methods: Deep learning is integrated with autofocus to improve motion artifact suppression, which is applied QSM of patients with Parkinson's disease (PD). The estimation of affine motion parameters in the autofocus method depends on signal-to-noise ratio and lacks accuracy when data sampling occurs outside the k-space center. A deep learning strategy is employed to remove the residual motion artifacts in autofocus. Results: Results obtained in simulated brain data (n =15) with reference truth show that the proposed autofocus deep learning method significantly improves the image quality of mGRE and QSM (p = 0.001 for SSIM, p < 0.0001 for PSNR and RMSE). Results from 10 PD patients with real motion artifacts in QSM have also been corrected using the proposed method and sent to an experienced radiologist for image quality evaluation, and the average image quality score has increased (p=0.0039). Conclusions: The proposed method enables substantial suppression of motion artifacts in mGRE and QSM.

eess.SP

Multi-delay arterial spin-labeled perfusion estimation with biophysics simulation and deep learning

Purpose: To develop biophysics-based method for estimating perfusion Q from arterial spin labeling (ASL) images using deep learning. Methods: A 3D U-Net (QTMnet) was trained to estimate perfusion from 4D tracer propagation images. The network was trained and tested on simulated 4D tracer concentration data based on artificial vasculature structure generated by constrained constructive optimization (CCO) method. The trained network was further tested in a synthetic brain ASL image based on vasculature network extracted from magnetic resonance (MR) angiography. The estimations from both trained network and a conventional kinetic model were compared in ASL images acquired from eight healthy volunteers. Results: QTMnet accurately reconstructed perfusion Q from concentration data. Relative error of the synthetic brain ASL image was 7.04% for perfusion Q, lower than the error using single-delay ASL model: 25.15% for Q, and multi-delay ASL model: 12.62% for perfusion Q. Conclusion: QTMnet provides accurate estimation on perfusion parameters and is a promising approach as a clinical ASL MRI image processing pipeline.

q-bio.QM

Recommended Implementation of Quantitative Susceptibility Mapping for Clinical Research in The Brain: A Consensus of the ISMRM Electro-Magnetic Tissue Properties Study Group

This article provides recommendations for implementing quantitative susceptibility mapping (QSM) for clinical brain research. It is a consensus of the ISMRM Electro-Magnetic Tissue Properties Study Group. While QSM technical development continues to advance rapidly, the current QSM methods have been demonstrated to be repeatable and reproducible for generating quantitative tissue magnetic susceptibility maps in the brain. However, the many QSM approaches available give rise to the need in the neuroimaging community for guidelines on implementation. This article describes relevant considerations and provides specific implementation recommendations for all steps in QSM data acquisition, processing, analysis, and presentation in scientific publications. We recommend that data be acquired using a monopolar 3D multi-echo GRE sequence, that phase images be saved and exported in DICOM format and unwrapped using an exact unwrapping approach. Multi-echo images should be combined before background removal, and a brain mask created using a brain extraction tool with the incorporation of phase-quality-based masking. Background fields should be removed within the brain mask using a technique based on SHARP or PDF, and the optimization approach to dipole inversion should be employed with a sparsity-based regularization. Susceptibility values should be measured relative to a specified reference, including the common reference region of whole brain as a region of interest in the analysis, and QSM results should be reported with - as a minimum - the acquisition and processing specifications listed in the last section of the article. These recommendations should facilitate clinical QSM research and lead to increased harmonization in data acquisition, analysis, and reporting.

physics.med-ph

High-pass filtered fidelity-imposed network edit (HP-FINE) for robust quantitative susceptibility mapping from high-pass filtered phase

Purpose: To improve the generalization ability of deep learning based predictions of quantitative susceptibility mapping (QSM) from high-pass filtered phase (HPFP) data. Methods: A network fine-tuning step called HP-FINE is proposed, which is based on the high-pass filtering forward model with low-frequency preservation regularization. Several comparisons were conducted: 1. HP-FINE with and without low-frequency regularization, 2. three 3D network architectures (Unet, Progressive Unet, and Big Unet), 3. two types of network output (recovered field and susceptibility), and 4. pre-training with and without the filtering augmentation. HPFP datasets with diverse high-pass filters, another acquisition voxel size, and prospective acquisition were used to assess the accuracy of QSM predictions. In the retrospective datasets, quantitative metrics (PSNR, SSIM, RMSE and HFEN) were used for evaluation. In the prospective dataset, statistics of ROI linear regression and Bland-Altman analysis were used for evaluation. Results: In the retrospective datasets, adding low-frequency regularization in HP-FINE substantially improved prediction accuracy compared to the pre-trained results, especially when combined with the filtering augmentation and recovered field output. In the prospective datasets, HP-FINE with low-frequency regularization and recovered field output demonstrated the preservation of ROI values, a result that was not achieved when using susceptibility as the output. Furthermore, Progressive Unet pre-trained with a combination of multiple losses outperformed both Unet and Progressive Unet pre-trained with a single loss in terms of preserving ROI values.

eess.IV

Maximum Spherical Mean Value (mSMV) Filtering for Whole Brain Quantitative Susceptibility Mapping

To develop a tissue field filtering algorithm, called maximum Spherical Mean Value (mSMV), for reducing shadow artifacts in quantitative susceptibility mapping (QSM) of the brain without requiring brain tissue erosion. Residual background field is a major source of shadow artifacts in QSM. The mSMV algorithm filters large field values near the border, where the maximum value of the harmonic background field is located. The effectiveness of mSMV for artifact removal was evaluated by comparing with existing QSM algorithms in numerical brain simulation as well as using in vivo human data acquired from 11 healthy volunteers and 93 patients. Numerical simulation showed that mSMV reduces shadow artifacts and improves QSM accuracy. Better shadow reduction, as demonstrated by lower QSM variation in the gray matter and higher QSM image quality score, was also observed in healthy subjects and in patients with hemorrhages, stroke and multiple sclerosis. The mSMV algorithm allows QSM maps that are substantially equivalent to those obtained using SMV-filtered dipole inversion without eroding the volume of interest.

eess.IV

mcLARO: Multi-Contrast Learned Acquisition and Reconstruction Optimization for simultaneous quantitative multi-parametric mapping

Purpose: To develop a method for rapid sub-millimeter T1, T2, T2* and QSM mapping in a single scan using multi-contrast Learned Acquisition and Reconstruction Optimization (mcLARO). Methods: A pulse sequence was developed by interleaving inversion recovery and T2 magnetization preparations and single-echo and multi-echo gradient echo acquisitions, which sensitized k-space data to T1, T2, T2* and magnetic susceptibility. The proposed mcLARO used a deep learning framework to optimize both the multi-contrast k-space under-sampling pattern and the image reconstruction based on image feature fusion. The proposed mcLARO method with R=8 under-sampling was validated in a retrospective ablation study using fully sampled data as reference and evaluated in a prospective study using separately acquired conventionally sampled quantitative maps as reference standard. Results: The retrospective ablation study showed improved image sharpness of mcLARO compared to the baseline network without multi-contrast sampling pattern optimization or image feature fusion, and negligible bias and narrow 95% limits of agreement on regional T1, T2, T2* and QSM values were obtained by the under-sampled reconstructions compared to the fully sampled reconstruction. The prospective study showed small or negligible bias and narrow 95% limits of agreement on regional T1, T2, T2* and QSM values by mcLARO (5:39 mins) compared to reference scans (40:03 mins in total). Conclusion: mcLARO enabled fast sub-millimeter T1, T2, T2* and QSM mapping in a single scan.

eess.IV

LARO: Learned Acquisition and Reconstruction Optimization to accelerate Quantitative Susceptibility Mapping

Quantitative susceptibility mapping (QSM) involves acquisition and reconstruction of a series of images at multi-echo time points to estimate tissue field, which prolongs scan time and requires specific reconstruction technique. In this paper, we present our new framework, called Learned Acquisition and Reconstruction Optimization (LARO), which aims to accelerate the multi-echo gradient echo (mGRE) pulse sequence for QSM. Our approach involves optimizing a Cartesian multi-echo k-space sampling pattern with a deep reconstruction network. Next, this optimized sampling pattern was implemented in an mGRE sequence using Cartesian fan-beam k-space segmenting and ordering for prospective scans. Furthermore, we propose to insert a recurrent temporal feature fusion module into the reconstruction network to capture signal redundancies along echo time. Our ablation studies show that both the optimized sampling pattern and proposed reconstruction strategy help improve the quality of the multi-echo image reconstructions. Generalization experiments show that LARO is robust on the test data with new pathologies and different sequence parameters. Our code is available at https://github.com/Jinwei1209/LARO.git.

eess.IV

Motion Artifact Reduction in Quantitative Susceptibility Mapping using Deep Neural Network

An approach to reduce motion artifacts in Quantitative Susceptibility Mapping using deep learning is proposed. We use an affine motion model with randomly created motion profiles to simulate motion-corrupted QSM images. The simulated QSM image is paired with its motion-free reference to train a neural network using supervised learning. The trained network is tested on unseen simulated motion-corrupted QSM images, in healthy volunteers and in Parkinson's disease patients. The results show that motion artifacts, such as ringing and ghosting, were successfully suppressed.

physics.med-ph

Temporal Feature Fusion with Sampling Pattern Optimization for Multi-echo Gradient Echo Acquisition and Image Reconstruction

Quantitative imaging in MRI usually involves acquisition and reconstruction of a series of images at multi-echo time points, which possibly requires more scan time and specific reconstruction technique compared to conventional qualitative imaging. In this work, we focus on optimizing the acquisition and reconstruction process of multi-echo gradient echo pulse sequence for quantitative susceptibility mapping as one important quantitative imaging method in MRI. A multi-echo sampling pattern optimization block extended from LOUPE-ST is proposed to optimize the k-space sampling patterns along echoes. Besides, a recurrent temporal feature fusion block is proposed and inserted into a backbone deep ADMM network to capture the signal evolution along echo time during reconstruction. Experiments show that both blocks help improve multi-echo image reconstruction performance.

eess.SP

NeRD: Neural Representation of Distribution for Medical Image Segmentation

We introduce Neural Representation of Distribution (NeRD) technique, a module for convolutional neural networks (CNNs) that can estimate the feature distribution by optimizing an underlying function mapping image coordinates to the feature distribution. Using NeRD, we propose an end-to-end deep learning model for medical image segmentation that can compensate the negative impact of feature distribution shifting issue caused by commonly used network operations such as padding and pooling. An implicit function is used to represent the parameter space of the feature distribution by querying the image coordinate. With NeRD, the impact of issues such as over-segmenting and missing have been reduced, and experimental results on the challenging white matter lesion segmentation and left atrial segmentation verify the effectiveness of the proposed method. The code is available via https://github.com/tinymilky/NeRD.

eess.IV

DEEPMIR: A DEEP neural network for differential detection of cerebral Microbleeds and IRon deposits in MRI

Lobar cerebral microbleeds (CMBs) and localized non-hemorrhage iron deposits in the basal ganglia have been associated with brain aging, vascular disease and neurodegenerative disorders. Particularly, CMBs are small lesions and require multiple neuroimaging modalities for accurate detection. Quantitative susceptibility mapping (QSM) derived from in vivo magnetic resonance imaging (MRI) is necessary to differentiate between iron content and mineralization. We set out to develop a deep learning-based segmentation method suitable for segmenting both CMBs and iron deposits. We included a convenience sample of 24 participants from the MESA cohort and used T2-weighted images, susceptibility weighted imaging (SWI), and QSM to segment the two types of lesions. We developed a protocol for simultaneous manual annotation of CMBs and non-hemorrhage iron deposits in the basal ganglia. This manual annotation was then used to train a deep convolution neural network (CNN). Specifically, we adapted the U-Net model with a higher number of resolution layers to be able to detect small lesions such as CMBs from standard resolution MRI. We tested different combinations of the three modalities to determine the most informative data sources for the detection tasks. In the detection of CMBs using single class and multiclass models, we achieved an average sensitivity and precision of between 0.84-0.88 and 0.40-0.59, respectively. The same framework detected non-hemorrhage iron deposits with an average sensitivity and precision of about 0.75-0.81 and 0.62-0.75, respectively. Our results showed that deep learning could automate the detection of small vessel disease lesions and including multimodal MR data (particularly QSM) can improve the detection of CMB and non-hemorrhage iron deposits with sensitivity and precision that is compatible with use in large-scale research studies.

eess.IV

Geometric Loss for Deep Multiple Sclerosis lesion Segmentation

Multiple sclerosis (MS) lesions occupy a small fraction of the brain volume, and are heterogeneous with regards to shape, size and locations, which poses a great challenge for training deep learning based segmentation models. We proposed a new geometric loss formula to address the data imbalance and exploit the geometric property of MS lesions. We showed that traditional region-based and boundary-aware loss functions can be associated with the formula. We further develop and instantiate two loss functions containing first- and second-order geometric information of lesion regions to enforce regularization on optimizing deep segmentation models. Experimental results on two MS lesion datasets with different scales, acquisition protocols and resolutions demonstrated the superiority of our proposed methods compared to other state-of-the-art methods.

cs.CV

Efficient Folded Attention for 3D Medical Image Reconstruction and Segmentation

Recently, 3D medical image reconstruction (MIR) and segmentation (MIS) based on deep neural networks have been developed with promising results, and attention mechanism has been further designed to capture global contextual information for performance enhancement. However, the large size of 3D volume images poses a great computational challenge to traditional attention methods. In this paper, we propose a folded attention (FA) approach to improve the computational efficiency of traditional attention methods on 3D medical images. The main idea is that we apply tensor folding and unfolding operations with four permutations to build four small sub-affinity matrices to approximate the original affinity matrix. Through four consecutive sub-attention modules of FA, each element in the feature tensor can aggregate spatial-channel information from all other elements. Compared to traditional attention methods, with moderate improvement of accuracy, FA can substantially reduce the computational complexity and GPU memory consumption. We demonstrate the superiority of our method on two challenging tasks for 3D MIR and MIS, which are quantitative susceptibility mapping and multiple sclerosis lesion segmentation.

eess.IV

Probabilistic Dipole Inversion for Adaptive Quantitative Susceptibility Mapping

A learning-based posterior distribution estimation method, Probabilistic Dipole Inversion (PDI), is proposed to solve the quantitative susceptibility mapping (QSM) inverse problem in MRI with uncertainty estimation. In PDI, a deep convolutional neural network (CNN) is used to represent the multivariate Gaussian distribution as the approximate posterior distribution of susceptibility given the input measured field. Such CNN is first trained on healthy subjects via posterior density estimation, where the training dataset contains samples from the true posterior distribution. Domain adaptations are then deployed on patient datasets with new pathologies not included in pre-training, where PDI updates the pre-trained CNN's weights in an unsupervised fashion by minimizing the Kullback-Leibler divergence between the approximate posterior distribution represented by CNN and the true posterior distribution from the likelihood distribution of a known physical model and pre-defined prior distribution. Based on our experiments, PDI provides additional uncertainty estimation compared to the conventional MAP approach, while addressing the potential issue of the pre-trained CNN when test data deviates from training.

eess.IV