arXiv ScienceSearch

arXiv subjects

Parisa Rashidi

Publications and source records attributed to Parisa Rashidi.

At least 19 recordsLinked to original sources

Teaching LLMs How ICU Physicians Approach Clinical Reasoning Through OMOP-Aligned Retrieval Improves Reasoning Across Clinical Domains

Clinical decision-making relies on identifying relevant patient information to guide diagnosis and treatment, a challenge that is especially difficult in the data-dense and rapidly changing intensive care unit (ICU). Large language models (LLMs) could support this task. However, existing applications and datasets mostly emphasize surface-level retrieval or factual recall rather than the inductive and deductive reasoning clinicians practice to select and reason over decision-relevant evidence. We hypothesized that training LLMs on expert ICU reasoning could yield clinical reasoning skills that generalize beyond critical care. Here we introduce ICU-REACT, a reasoning dataset developed with 19 clinicians through a clinician-in-the-loop framework to teach LLMs to perform information retrieval and context-aware clinical reasoning in the ICU. Using ICU-REACT, we fine-tuned Clin-REACT models spanning 8B-70B parameters and three model families. Across five clinical reasoning benchmarks, Clin-REACT consistently outperformed its backbone models and open-source general-purpose and medical LLMs. Gains extended to different tasks including script concordance tests, and downstream diagnosis and treatment tasks. These findings suggest that expert reasoning supervision in critical care can improve broader clinical reasoning, although prospective evaluation is needed before real-world clinical use.

cs.CL

DiSTILL: A Hybrid Cloud-HPC Workflow System for Reproducible Spatial Transcriptomics Analysis

Spatial transcriptomics workflows increasingly combine large annotated data objects, notebook-based analyses, and resource-intensive statistical models that must be executed on high-performance computing (HPC) systems. In practice, these workflows are often difficult to reproduce because configuration, validation, stage execution, and artifact handling are fragmented across $\textit{ad hoc}$ scripts and manually edited notebooks. We present $\textit{DiSTILL}$ (Disease Diagnosis from Spatial Transcriptomics via Interpretable Latent Learning), a hybrid cloud$-$HPC workflow system for reproducible spatial transcriptomics (ST) analysis. DiSTILL combines an application programming interface (API) backend built with $\texttt{FastAPI}$, a web frontend, a dataset and preset registry, and a Python pipeline generator that materializes run-specific execution bundles and $\texttt{SLURM}$ submission scripts. The system supports local, Secure Shell (SSH)-mediated, and pull-based poller execution modes, enabling HPC submission in environments where persistent API-initiated automation is restricted. We describe the system through the lens of an inflammatory bowel disease (IBD) ST workflow that operationalizes the analytical pipeline of Tan $\textit{et al.}$ into an auditable application layer. Accordingly, the contribution of this paper is a workflow systems contribution centered on reproducible execution, queue-based orchestration, configuration semantics, and deployment across a split cloud$-$HPC architecture. The broader application goal of DiSTILL is to support user-supplied datasets that satisfy the schema assumptions of the wrapped analytical pipeline.

q-bio.GN

Risk Stratification for ICU Delirium using Pervasive Ambient Sensing Information

Delirium is a common and serious complication in the Intensive Care Unit (ICU), associated with increased morbidity, prolonged hospital stays, and higher healthcare costs. Despite its prevalence, early prediction and prevention remain challenging. Environmental factors such as ambient sound and light may influence the onset of delirium, yet they are often overlooked in risk assessments. In this study, we examined whether light intensity and sound pressure levels can independently predict delirium across multiple prediction horizons. We evaluated four efficient sequential neural network models on data collected from 9 ICUs across 309 patients to predict delirium for 10 prediction-window sizes. We reported feature importance and direction of influence using Shapley Additive Explanations analysis. The convolutional model achieved the strongest discrimination, with AUC = 0.80 on sound data and on combined data. Sound features were the dominant predictors overall. Integrating sound with light improved short-term ($<1$ week) prediction, with the combined model assigning the highest risk immediately after the sensing period. These findings suggest that passive ambient sensing, especially sound, can add a clinically meaningful, interpretable signal for delirium risk estimation and offer a practical pathway to enrich multimodal ICU prediction and prevention strategies.

cs.LG

A Knowledge-Injection Framework for Zero-Shot Adaptation of LLMs to Delirium Prediction

Large language models show promise for clinical prediction, but zero-shot performance on specialized tasks is limited by incomplete domain knowledge, especially for smaller locally deployable models. We present a lightweight knowledge-injection framework for zero-shot ICU delirium prediction that augments a deterministic natural-language summary of structured electronic health record data with an external clinical knowledge report at inference time, without fine-tuning or retrieval. We evaluate LLaMA 3.1 8B and LLaMA 3.3 70B on 3,160 ICU admissions from the MIMIC IV dataset. Adding a clinically meaningful external knowledge report improves AUROC by 8.57 percentage points for the 8B model and 1.99 percentage points for the 70B model compared to no external knowledge. Relative to a GPT-5.2 frontier-model reference without external knowledge report (AUROC 68.86%), knowledge injection reduces the performance gap from 15.66 to 7.09 AUROC points for LLaMA 8B and from 5.30 to 3.31 AUROC points for LLaMA 70B. Random control reports do not improve performance and often degrade it, indicating that gains depend on clinically meaningful content rather than added prompt length alone. SHAP-based attribution further confirms that the injected knowledge is actively used during prediction. These findings suggest that inference-time knowledge injection can narrow the gap between locally deployable open-weight models and frontier closed models while preserving a practical, privacy-preserving workflow for resource-constrained clinical settings.

cs.CL

Auditing Multimodal LLM Raters: Central Tendency Bias in Clinical Ordinal Scoring

Multimodal large language models (LLMs) are increasingly explored as automated evaluators in clinical settings, yet their scoring behavior on ordinal clinical scales remains poorly understood. We benchmark three frontier LLM families against supervised deep learning models for scoring Clock Drawing Test (CDT) images on two public datasets using the Shulman rubric. While fully fine-tuned Vision Transformers achieve the best calibration (MAE 0.52, within-1 accuracy 91%), zero-shot LLMs remain competitive on tolerance-based agreement (GPT-5 MAE 0.67, within-1 accuracy 92%) despite higher absolute error. However, per-score analysis reveals that all three LLM families exhibit a pronounced central tendency effect (systematic endpoint compression): predictions are systematically compressed toward the middle of the scale, with over-prediction at the low end (score 0 to 1) and under-prediction at the high end (score 5 to 4). This effect disproportionately affects the clinically critical extremes where accurate scoring most impacts screening decisions for cognitive impairment. Targeted ablations show that neither few-shot exemplars spanning the full score range nor removing clinical terminology from the prompt eliminates the effect. Our findings extend the LLM-as-a-judge bias literature from NLP evaluation to clinical assessment, and highlight the need for calibration-aware evaluation and post-hoc calibration before deploying LLM-based raters in high-stakes screening workflows.

cs.CV

Federated Learning with Multi-Partner OneFlorida+ Consortium Data for Predicting Major Postoperative Complications

Background: This study aims to develop and validate federated learning models for predicting major postoperative complications and mortality using a large multicenter dataset from the OneFlorida Data Trust. We hypothesize that federated learning models will offer robust generalizability while preserving data privacy and security. Methods: This retrospective, longitudinal, multicenter cohort study included 358,644 adult patients admitted to five healthcare institutions, who underwent 494,163 inpatient major surgical procedures from 2012-2023. We developed and internally and externally validated federated learning models to predict the postoperative risk of intensive care unit (ICU) admission, mechanical ventilation (MV) therapy, acute kidney injury (AKI), and in-hospital mortality. These models were compared with local models trained on data from a single center and central models trained on a pooled dataset from all centers. Performance was primarily evaluated using area under the receiver operating characteristics curve (AUROC) and the area under the precision-recall curve (AUPRC) values. Results: Our federated learning models demonstrated strong predictive performance, with AUROC scores consistently comparable or superior performance in terms of AUROC and AUPRC across all outcomes and sites. Our federated learning models also demonstrated strong generalizability, with comparable or superior performance in terms of both AUROC and AUPRC compared to the best local learning model at each site. Conclusions: By leveraging multicenter data, we developed robust, generalizable, and privacy-preserving predictive models for major postoperative complications and mortality. These findings support the feasibility of federated learning in clinical decision support systems.

cs.LG

Learning optimal treatment strategies for intraoperative hypotension using deep reinforcement learning

Traditional methods of surgical decision making heavily rely on human experience and prompt actions, which are variable. A data-driven system generating treatment recommendations based on patient states can be a substantial asset in perioperative decision-making, as in cases of intraoperative hypotension, for which suboptimal management is associated with acute kidney injury (AKI), a common and morbid postoperative complication. We developed a Reinforcement Learning (RL) model to recommend optimum dose of intravenous (IV) fluid and vasopressors during surgery to avoid intraoperative hypotension and postoperative AKI. We retrospectively analyzed 50,021 surgeries from 42,547 adult patients who underwent major surgery at a quaternary care hospital between June 2014 and September 2020. Of these, 34,186 surgeries were used for model training and 15,835 surgeries were reserved for testing. We developed a Deep Q-Networks based RL model using 16 variables including intraoperative physiologic time series, total dose of IV fluid and vasopressors extracted for every 15-minute epoch. The model replicated 69% of physician's decisions for the dosage of vasopressors and proposed higher or lower dosage of vasopressors than received in 10% and 21% of the treatments, respectively. In terms of IV fluids, the model's recommendations were within 0.05 ml/kg/15 min of the actual dose in 41% of the cases, with higher or lower doses recommended for 27% and 32% of the treatments, respectively. The model resulted in a higher estimated policy value compared to the physicians' actual treatments, as well as random and zero-drug policies. AKI prevalence was the lowest in patients receiving medication dosages that aligned with model's decisions. Our findings suggest that implementation of the model's policy has the potential to reduce postoperative AKI and improve other outcomes driven by intraoperative hypotension.

q-bio.QM

Bridge2AI: Building A Cross-disciplinary Curriculum Towards AI-Enhanced Biomedical and Clinical Care

Objective: As AI becomes increasingly central to healthcare, there is a pressing need for bioinformatics and biomedical training systems that are personalized and adaptable. Materials and Methods: The NIH Bridge2AI Training, Recruitment, and Mentoring (TRM) Working Group developed a cross-disciplinary curriculum grounded in collaborative innovation, ethical data stewardship, and professional development within an adapted Learning Health System (LHS) framework. Results: The curriculum integrates foundational AI modules, real-world projects, and a structured mentee-mentor network spanning Bridge2AI Grand Challenges and the Bridge Center. Guided by six learner personas, the program tailors educational pathways to individual needs while supporting scalability. Discussion: Iterative refinement driven by continuous feedback ensures that content remains responsive to learner progress and emerging trends. Conclusion: With over 30 scholars and 100 mentors engaged across North America, the TRM model demonstrates how adaptive, persona-informed training can build interdisciplinary competencies and foster an integrative, ethically grounded AI education in biomedical contexts.

cs.CY

Human-Centered Development of an Explainable AI Framework for Real-Time Surgical Risk Surveillance

Background: Artificial Intelligence (AI) clinical decision support (CDS) systems have the potential to augment surgical risk assessments, but successful adoption depends on an understanding of end-user needs and current workflows. This study reports the initial co-design of MySurgeryRisk, an AI CDS tool to predict the risk of nine post-operative complications in surgical patients. Methods: Semi-structured focus groups and interviews were held as co-design sessions with perioperative physicians at a tertiary academic hospital in the Southeastern United States. Participants were read a surgical vignette and asked questions to elicit an understanding of their current decision-making practices before being introduced to the MySurgeryRisk prototype web interface. They were asked to provide feedback on the user interface and system features. Session transcripts were qualitatively coded, after which thematic analysis took place. Results: Data saturation was reached after 20 surgeons and anesthesiologists from varying career stages participated across 11 co-design sessions. Thematic analysis resulted in five themes: (1) decision-making cognitive processes, (2) current approach to decision-making, (3) future approach to decision-making with MySurgeryRisk, (4) feedback on current MySurgeryRisk prototype, and (5) trustworthy considerations. Conclusion: Clinical providers perceived MySurgeryRisk as a promising CDS tool that factors in a large volume of data and is computed in real-time without any need for manual input. Participants provided feedback on the design of the interface and imaged applications of the tool in the clinical workflow. However, its successful implementation will depend on its actionability and explainability of model outputs, integration into current electronic systems, and calibration of trust among end-users.

cs.HC

Validation of the MySurgeryRisk Algorithm for Predicting Complications and Death after Major Surgery: A Retrospective Multicenter Study Using OneFlorida Data Trust

Despite advances in surgical techniques and care, postoperative complications are prevalent and effects up to 15% of the patients who underwent a major surgery. The objective of this study is to develop and validate models for predicting postoperative complications and death after major surgery on a large and multicenter dataset, following the previously validated MySurgeryRisk algorithm. This retrospective, longitudinal and multicenter cohort analysis included 508,097 encounters from 366,875 adult inpatients who underwent major surgeries and were admitted to healthcare institutions within the OneFlorida+ network between 01/01/2012 and 04/29/2023. We applied the validated feature selection and transformation approach in MySurgeryRisk models and redeveloped eXtreme Gradient Boosting (XGBoost) models for predicting risk of postoperative acute kidney injury (AKI), need for intensive care unit (ICU) admission, need for mechanical ventilation (MV) therapy and in-hospital mortality on a development set and evaluated the model performance on a validation set. Area under the receiver operating characteristics curve values were obtained for need for ICU admission, 0.93 (95% Confidence Interval [CI], 0.93-0.93); need for MV, 0.94 (95% CI, 0.94-0.94); AKI, 0.92 (95% CI, 0.92-0.92); and in-hospital mortality, 0.95 (95% CI, 0.94-0.95). Area under the precision-recall curve values were computed for need for ICU admission, 0.62 (95% CI, 0.62-0.63); need for MV, 0.51 (95% CI, 0.49-0.52); AKI, 0.53 (95% CI, 0.53-0.54); and in-hospital mortality, 0.26 (95% CI, 0.24-0.29). The performance of these models is comparable to that of the previously validated MySurgeryRisk models, suggesting the enhanced generalizability of the models. Primary procedure code and provider specialty consistently appeared as the top influential variables, providing valuable insights into the factors influencing surgical outcomes.

cs.HC

Quantifying Circadian Desynchrony in ICU Patients and Its Association with Delirium

Background: Circadian desynchrony characterized by the misalignment between an individual's internal biological rhythms and external environmental cues, significantly affects various physiological processes and health outcomes. Quantifying circadian desynchrony often requires prolonged and frequent monitoring, and currently, an easy tool for this purpose is missing. Additionally, its association with the incidence of delirium has not been clearly explored. Methods: A prospective observational study was carried out in intensive care units (ICU) of a tertiary hospital. Circadian transcriptomics of blood monocytes from 86 individuals were collected on two consecutive days, although a second sample could not be obtained from all participants. Using two public datasets comprised of healthy volunteers, we replicated a model for determining internal circadian time. We developed an approach to quantify circadian desynchrony by comparing internal circadian time and external blood collection time. We applied the model and quantified circadian desynchrony index among ICU patients, and investigated its association with the incidence of delirium. Results: The replicated model for determining internal circadian time achieved comparable high accuracy. The quantified circadian desynchrony index was significantly higher among critically ill ICU patients compared to healthy subjects, with values of 10.03 hours vs 2.50-2.95 hours (p < 0.001). Most ICU patients had a circadian desynchrony index greater than 9 hours. Additionally, the index was lower in patients whose blood samples were drawn after 3pm, with values of 5.00 hours compared to 10.01-10.90 hours in other groups (p < 0.001)...

q-bio.QM

An Iterative, User-Centered Design of a Clinical Decision Support System for Critical Care Assessments: Co-Design Sessions with ICU Clinical Providers

This study reports the findings of qualitative interview sessions conducted with ICU clinicians for the co-design of a system user interface of an artificial intelligence (AI)-driven clinical decision support (CDS) system. This system integrates medical record data with wearable sensor, video, and environmental data into a real-time dynamic model that quantifies patients' risk of clinical decompensation and risk of developing delirium, providing actionable alerts to augment clinical decision-making in the ICU setting. Co-design sessions were conducted as semi-structured focus groups and interviews with ICU clinicians, including physicians, mid-level practitioners, and nurses. Study participants were asked about their perceptions on AI-CDS systems, their system preferences, and were asked to provide feedback on the current user interface prototype. Session transcripts were qualitatively analyzed to identify key themes related to system utility, interface design features, alert preferences, and implementation considerations. Ten clinicians participated in eight sessions. The analysis identified five themes: (1) AI's computational utility, (2) workflow optimization, (3) effects on patient care, (4) technical considerations, and (5) implementation considerations. Clinicians valued the CDS system's multi-modal continuous monitoring and AI's capacity to process large volumes of data in real-time to identify patient risk factors and suggest action items. Participants underscored the system's unique value in detecting delirium and promoting non-pharmacological delirium prevention measures. The actionability and intuitive interpretation of the presented information was emphasized. ICU clinicians recognize the potential of an AI-driven CDS system for ICU delirium and acuity to improve patient outcomes and clinical workflows.

cs.HC

MELON: Multimodal Mixture-of-Experts with Spectral-Temporal Fusion for Long-Term Mobility Estimation in Critical Care

Patient mobility monitoring in intensive care is critical for ensuring timely interventions and improving clinical outcomes. While accelerometry-based sensor data are widely adopted in training artificial intelligence models to estimate patient mobility, existing approaches face two key limitations highlighted in clinical practice: (1) modeling the long-term accelerometer data is challenging due to the high dimensionality, variability, and noise, and (2) the absence of efficient and robust methods for long-term mobility assessment. To overcome these challenges, we introduce MELON, a novel multimodal framework designed to predict 12-hour mobility status in the critical care setting. MELON leverages the power of a dual-branch network architecture, combining the strengths of spectrogram-based visual representations and sequential accelerometer statistical features. MELON effectively captures global and fine-grained mobility patterns by integrating a pre-trained image encoder for rich frequency-domain feature extraction and a Mixture-of-Experts encoder for sequence modeling. We trained and evaluated the MELON model on the multimodal dataset of 126 patients recruited from nine Intensive Care Units at the University of Florida Health Shands Hospital main campus in Gainesville, Florida. Experiments showed that MELON outperforms conventional approaches for 12-hour mobility status estimation with an overall area under the receiver operating characteristic curve (AUROC) of 0.82 (95\%, confidence interval 0.78-0.86). Notably, our experiments also revealed that accelerometer data collected from the wrist provides robust predictive performance compared with data from the ankle, suggesting a single-sensor solution that can reduce patient burden and lower deployment costs...

cs.LG

MANDARIN: Mixture-of-Experts Framework for Dynamic Delirium and Coma Prediction in ICU Patients: Development and Validation of an Acute Brain Dysfunction Prediction Model

Acute brain dysfunction (ABD) is a common, severe ICU complication, presenting as delirium or coma and leading to prolonged stays, increased mortality, and cognitive decline. Traditional screening tools like the Glasgow Coma Scale (GCS), Confusion Assessment Method (CAM), and Richmond Agitation-Sedation Scale (RASS) rely on intermittent assessments, causing delays and inconsistencies. In this study, we propose MANDARIN (Mixture-of-Experts Framework for Dynamic Delirium and Coma Prediction in ICU Patients), a 1.5M-parameter mixture-of-experts neural network to predict ABD in real-time among ICU patients. The model integrates temporal and static data from the ICU to predict the brain status in the next 12 to 72 hours, using a multi-branch approach to account for current brain status. The MANDARIN model was trained on data from 92,734 patients (132,997 ICU admissions) from 2 hospitals between 2008-2019 and validated externally on data from 11,719 patients (14,519 ICU admissions) from 15 hospitals and prospectively on data from 304 patients (503 ICU admissions) from one hospital in 2021-2024. Three datasets were used: the University of Florida Health (UFH) dataset, the electronic ICU Collaborative Research Database (eICU), and the Medical Information Mart for Intensive Care (MIMIC)-IV dataset. MANDARIN significantly outperforms the baseline neurological assessment scores (GCS, CAM, and RASS) for delirium prediction in both external (AUROC 75.5% CI: 74.2%-76.8% vs 68.3% CI: 66.9%-69.5%) and prospective (AUROC 82.0% CI: 74.8%-89.2% vs 72.7% CI: 65.5%-81.0%) cohorts, as well as for coma prediction (external AUROC 87.3% CI: 85.9%-89.0% vs 72.8% CI: 70.6%-74.9%, and prospective AUROC 93.4% CI: 88.5%-97.9% vs 67.7% CI: 57.7%-76.8%) with a 12-hour lead time. This tool has the potential to assist clinicians in decision-making by continuously monitoring the brain status of patients in the ICU.

cs.AI

Integrating Persian Lip Reading in Surena-V Humanoid Robot for Human-Robot Interaction

Lip reading is vital for robots in social settings, improving their ability to understand human communication. This skill allows them to communicate more easily in crowded environments, especially in caregiving and customer service roles. Generating a Persian Lip-reading dataset, this study integrates Persian lip-reading technology into the Surena-V humanoid robot to improve its speech recognition capabilities. Two complementary methods are explored, an indirect method using facial landmark tracking and a direct method leveraging convolutional neural networks (CNNs) and long short-term memory (LSTM) networks. The indirect method focuses on tracking key facial landmarks, especially around the lips, to infer movements, while the direct method processes raw video data for action and speech recognition. The best-performing model, LSTM, achieved 89\% accuracy and has been successfully implemented into the Surena-V robot for real-time human-robot interaction. The study highlights the effectiveness of these methods, particularly in environments where verbal communication is limited.

cs.CV

MANGO: Multimodal Acuity traNsformer for intelliGent ICU Outcomes

Estimation of patient acuity in the Intensive Care Unit (ICU) is vital to ensure timely and appropriate interventions. Advances in artificial intelligence (AI) technologies have significantly improved the accuracy of acuity predictions. However, prior studies using machine learning for acuity prediction have predominantly relied on electronic health records (EHR) data, often overlooking other critical aspects of ICU stay, such as patient mobility, environmental factors, and facial cues indicating pain or agitation. To address this gap, we present MANGO: the Multimodal Acuity traNsformer for intelliGent ICU Outcomes, designed to enhance the prediction of patient acuity states, transitions, and the need for life-sustaining therapy. We collected a multimodal dataset ICU-Multimodal, incorporating four key modalities, EHR data, wearable sensor data, video of patient's facial cues, and ambient sensor data, which we utilized to train MANGO. The MANGO model employs a multimodal feature fusion network powered by Transformer masked self-attention method, enabling it to capture and learn complex interactions across these diverse data modalities even when some modalities are absent. Our results demonstrated that integrating multiple modalities significantly improved the model's ability to predict acuity status, transitions, and the need for life-sustaining therapy. The best-performing models achieved an area under the receiver operating characteristic curve (AUROC) of 0.76 (95% CI: 0.72-0.79) for predicting transitions in acuity status and the need for life-sustaining therapy, while 0.82 (95% CI: 0.69-0.89) for acuity status prediction...

eess.SP

Peri-AIIMS: Perioperative Artificial Intelligence Driven Integrated Modeling of Surgeries using Anesthetic, Physical and Cognitive Statuses for Predicting Hospital Outcomes

The association between preoperative cognitive status and surgical outcomes is a critical, yet scarcely explored area of research. Linking intraoperative data with postoperative outcomes is a promising and low-cost way of evaluating long-term impacts of surgical interventions. In this study, we evaluated how preoperative cognitive status as measured by the clock drawing test contributed to predicting length of hospital stay, hospital charges, average pain experienced during follow-up, and 1-year mortality over and above intraoperative variables, demographics, preoperative physical status and comorbidities. We expanded our analysis to 6 specific surgical groups where sufficient data was available for cross-validation. The clock drawing images were represented by 10 constructional features discovered by a semi-supervised deep learning algorithm, previously validated to differentiate between dementia and non-dementia patients. Different machine learning models were trained to classify postoperative outcomes in hold-out test sets. The models were compared to their relative performance, time complexity, and interpretability. Shapley Additive Explanations (SHAP) analysis was used to find the most predictive features for classifying different outcomes in different surgical contexts. Relative classification performances achieved by different feature sets showed that the perioperative cognitive dataset which included clock drawing features in addition to intraoperative variables, demographics, and comorbidities served as the best dataset for 12 of 18 possible surgery-outcome combinations...

cs.LG

DeLLiriuM: A large language model for delirium prediction in the ICU using structured EHR

Delirium is an acute confusional state that has been shown to affect up to 31% of patients in the intensive care unit (ICU). Early detection of this condition could lead to more timely interventions and improved health outcomes. While artificial intelligence (AI) models have shown great potential for ICU delirium prediction using structured electronic health records (EHR), most of them have not explored the use of state-of-the-art AI models, have been limited to single hospitals, or have been developed and validated on small cohorts. The use of large language models (LLM), models with hundreds of millions to billions of parameters, with structured EHR data could potentially lead to improved predictive performance. In this study, we propose DeLLiriuM, a novel LLM-based delirium prediction model using EHR data available in the first 24 hours of ICU admission to predict the probability of a patient developing delirium during the rest of their ICU admission. We develop and validate DeLLiriuM on ICU admissions from 104,303 patients pertaining to 195 hospitals across three large databases: the eICU Collaborative Research Database, the Medical Information Mart for Intensive Care (MIMIC)-IV, and the University of Florida Health's Integrated Data Repository. The performance measured by the area under the receiver operating characteristic curve (AUROC) showed that DeLLiriuM outperformed all baselines in two external validation sets, with 0.77 (95% confidence interval 0.76-0.78) and 0.84 (95% confidence interval 0.83-0.85) across 77,543 patients spanning 194 hospitals. To the best of our knowledge, DeLLiriuM is the first LLM-based delirium prediction tool for the ICU based on structured EHR data, outperforming deep learning baselines which employ structured features and can provide helpful information to clinicians for timely interventions.

cs.AI