arXiv ScienceSearch

arXiv subjects

P. Stassi

Publications and source records attributed to P. Stassi.

10 recordsLinked to original sources

Performance of the image persistence model for Euclid infrared detectors

Large-format infrared detectors are at the heart of major ground and space-based astronomical instruments, and the HgCdTe HxRG is the most widely used. The Near Infrared Spectrometer and Photometer (NISP) of the ESA's Euclid mission launched in July 2023 hosts 16 H2RG detectors in the focal plane. Their performance relies heavily on the effect of image persistence, which results in residual images that can remain in the detector for a long time contaminating any subsequent observations. Deriving a precise model of image persistence is challenging due to the sensitivity of this effect to observation history going back hours or even days. Nevertheless, persistence removal is a critical part of image processing because it limits the accuracy of the derived cosmological parameters. We will present the empirical model of image persistence derived from ground characterization data, adapted to the Euclid observation sequence and compared with the data obtained during the in-orbit calibrations of the satellite.

astro-ph.IM

Euclid. IV. The NISP Calibration Unit

The near-infrared calibration unit (NI-CU) on board Euclid's Near-Infrared Spectrometer and Photometer (NISP) is the first astronomical calibration lamp based on light-emitting diodes (LEDs) to be operated in space. Euclid is a mission in ESA's Cosmic Vision 2015-2025 framework, to explore the dark universe and provide a next-level characterisation of the nature of gravitation, dark matter, and dark energy. Calibrating photometric and spectrometric measurements of galaxies to better than 1.5% accuracy in a survey homogeneously mapping ~14000 deg^2 of extragalactic sky requires a very detailed characterisation of near-infrared (NIR) detector properties, as well their constant monitoring in flight. To cover two of the main contributions - relative pixel-to-pixel sensitivity and non-linearity characteristics - as well as support other calibration activities, NI-CU was designed to provide spatially approximately homogeneous (<12% variations) and temporally stable illumination (0.1%-0.2% over 1200s) over the NISP detector plane, with minimal power consumption and energy dissipation. NI-CU is covers the spectral range ~[900,1900] nm - at cryo-operating temperature - at 5 fixed independent wavelengths to capture wavelength-dependent behaviour of the detectors, with fluence over a dynamic range of >=100 from ~15 ph s^-1 pixel^-1 to >1500 ph s^-1 pixel^-1. For this functionality, NI-CU is based on LEDs. We describe the rationale behind the decision and design process, describe the challenges in sourcing the right LEDs, as well as the qualification process and lessons learned. We also provide a description of the completed NI-CU, its capabilities and performance as well as its limits. NI-CU has been integrated into NISP and the Euclid satellite, and since Euclid's launch in July 2023 has started supporting survey operations.

astro-ph.IM

Molecular Bremsstrahlung Radiation at GHz Frequencies in Air

A detection technique for ultra-high energy cosmic rays, complementary to the fluorescence technique, would be the use of the molecular Bremsstrahlung radiation emitted by low-energy ionization electrons left after the passage of the showers in the atmosphere. In this article, a detailed estimate of the spectral intensity of photons at ground level originating from this radiation is presented. The spectral intensity expected from the passage of the high-energy electrons of the cascade is also estimated. The absorption of the photons in the plasma of electrons/neutral molecules is shown to be negligible. The obtained spectral intensity is shown to be $2\times10^{-21} $W cm$^{-2}$ GHz$^{-1}$ at 10 km from the shower core for a vertical shower induced by a proton of $10^{17.5}$ eV. In addition, a recent measurement of Bremsstrahlung radiation in air at gigahertz frequencies from a beam of electrons produced at 95 keV by an electron gun is also discussed and reasonably reproduced by the model.

astro-ph.IM

Results of a self-triggered prototype system for radio-detection of extensive air showers at the Pierre Auger Observatory

We describe the experimental setup and the results of RAuger, a small radio-antenna array, consisting of three fully autonomous and self-triggered radio-detection stations, installed close to the center of the Surface Detector (SD) of the Pierre Auger Observatory in Argentina. The setup has been designed for the detection of the electric field strength of air showers initiated by ultra-high energy cosmic rays, without using an auxiliary trigger from another detection system. Installed in December 2006, RAuger was terminated in May 2010 after 65 registered coincidences with the SD. The sky map in local angular coordinates (i.e., zenith and azimuth angles) of these events reveals a strong azimuthal asymmetry which is in agreement with a mechanism dominated by a geomagnetic emission process. The correlation between the electric field and the energy of the primary cosmic ray is presented for the first time, in an energy range covering two orders of magnitude between 0.1 EeV and 10 EeV. It is demonstrated that this setup is relatively more sensitive to inclined showers, with respect to the SD. In addition to these results, which underline the potential of the radio-detection technique, important information about the general behavior of self-triggering radio-detection systems has been obtained. In particular, we will discuss radio self-triggering under varying local electric-field conditions.

astro-ph.HE

Cryogenic characterization of the Planck sorption cooler system flight model

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221 Two continuous closed-cycle hydrogen Joule-Thomson (J-T) sorption coolers have been fabricated and assembled by the Jet Propulsion Laboratory (JPL) for the European Space Agency (ESA) Planck mission. Each refrigerator has been designed to provide a total of ~ 1W of cooling power at two instrument interfaces: they directly cool the Planck Low Frequency Instrument (LFI) around 20K while providing a pre-cooling stage for a 4 K J-T mechanical refrigerator for the High Frequency Instrument (HFI). After sub-system level validation at JPL, the cryocoolers have been delivered to ESA in 2005. In this paper we present the results of the cryogenic qualification and test campaigns of the Nominal Unit on the flight model spacecraft performed at the CSL (Centre Spatial de Liege) facilities in 2008. Test results in terms of input power, cooling power, temperature, and temperature fluctuations over the flight allowable ranges for these interfaces are reported and analyzed with respect to mission requirements.

astro-ph.IM

Radio emission of extensive air shower at CODALEMA: Polarization of the radio emission along the v*B vector

Cosmic rays extensive air showers (EAS) are associated with transient radio emission, which could provide an efficient new detection method of high energy cosmic rays, combining a calorimetric measurement with a high duty cycle. The CODALEMA experiment, installed at the Radio Observatory in Nancay, France, is investigating this phenomenon in the 10^17 eV region. One challenging point is the understanding of the radio emission mechanism. A first observation indicating a linear relation between the electric field produced and the cross product of the shower axis with the geomagnetic field direction has been presented (B. Revenu, this conference). We will present here other strong evidences for this linear relationship, and some hints on its physical origin.

astro-ph.HE

Geomagnetic origin of the radio emission from cosmic ray induced air showers observed by CODALEMA

The new setup of the CODALEMA experiment installed at the Radio Observatory in Nancay, France, is described. It includes broadband active dipole antennas and an extended and upgraded particle detector array. The latter gives access to the air shower energy, allowing us to compute the efficiency of the radio array as a function of energy. We also observe a large asymmetry in counting rates between showers coming from the North and the South in spite of the symmetry of the detector. The observed asymmetry can be interpreted as a signature of the geomagnetic origin of the air shower radio emission. A simple linear dependence of the electric field with respect to vxB is used which reproduces the angular dependencies of the number of radio events and their electric polarity.

astro-ph.HE

Detection of the Cherenkov light diffused by Sea Water with the ULTRA Experiment

The study of Ultra High Energy Cosmic Rays represents one of the most challenging topic in the Cosmic Rays and in the Astroparticle Physics fields. The interaction of primary particles with atmospheric nuclei produces a huge Extensive Air Shower together with isotropic emission of UV fluorescence light and highly directional Cherenkov photons, that are reflected/diffused isotropically by the impact on the Earth's surface or on high optical depth clouds. For space-based observations, detecting the reflected Cherenkov signal in a delayed coincidence with the fluorescence light improves the accuracy of the shower reconstruction in space and in particular the measurement of the shower maximum, giving a strong signature for discriminating hadrons and neutrinos, and helping to estimate the primary chemical composition. Since the Earth's surface is mostly covered by water, the ULTRA (UV Light Transmission and Reflection in the Atmosphere)experiment has been designed to provide the diffusing properties of sea water, overcoming the lack of information in this specific field. A small EAS array, made up of 5 particle detectors, and an UV optical device, have been coupled to detect in coincidence both electromagnetic and UV components. The detector was in operation from May to December, 2005, in a small private harbor in Capo Granitola (Italy); the results of these measurements in terms of diffusion coefficient and threshold energy are presented here.

astro-ph

Results from the ULTRA experiment in the framework of the EUSO project

The detection of Cerenkov light from EAS in a delayed coincidence with fluorescence light gives a strong signature to discriminate protons and neutrinos in cosmic rays. For this purpose, the ULTRA experiment has been designed with 2 detectors: a small EAS array (ETscope) and an UV optical device including wide field (Belenos) and narrow field (UVscope) Cerenkov light detectors. The array measures the shower size and the arrival direction of the incoming EAS, while the UV devices, pointing both to zenith and nadir, are used to determine the amount of direct and diffused coincident Cerenkov light. This information, provided for different diffusing surfaces, will be used to verify the possibility of detecting from Space the Cerenkov light produced by UHECRs with the EUSO experiment, on board the ISS.

astro-ph

Experimental study of a liquid Xenon PET prototype module

A detector using liquid Xenon in the scintillation mode is studied for Positron Emission Tomography (PET). The specific design aims at taking full advantage of the liquid Xenon properties. It does feature a promising insensitive to any parallax effect. This work reports on the performances of the first LXe prototype module, equipped with a position sensitive PMT operating in the VUV range (178 nm).

physics.med-ph